N337NB
Service difficulty reports · 236
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N337NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N337NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2019041702504Floor Support · corrodedCORROSION FLOOR BEAM -Y1162 LOC FROM FR 68 TO FR 69 AT AFT GALLEY AREA. REPLACED FLOOR BEAM -Y1162 LOCATED FROM FR68 TO FR69 AT AFT GALLEY AREA AS PER A319 SRM 51-72-11 AND DRAWING D53472780, ISSUE "D" RELEASE DATE:26-APR-18, D53474180.SDR DALA2019041702503Fitting · corrodedCORROSION CENTER FITTING FROM FR 16 TO FR 20 AT LEVEL STR 23L AT FWD GALLEY AREA (1 EA). REPLACED CENTER FITTING LOCATED FROM FR 16 TO FR 20 AT LEVEL STR 23L AT FWD GALLEY AREA AS PER A319 SRM 51-72-11 AND DRAWING D53112109SDR DALA2019041652466Seat Track · corrodedCORROSION SEAT TRACK +Y765 LOC.FR12 TO FR24 FWD GALLEY AREA (1 EA). REPLACED SEAT TRACK +Y765 LOC. FR.12 TO FR.24 FWD GALLEY AREA AS PER A319 51-72-11 DWG D53110920 (SHEET 1) ISSUE D RELEASE DATE 07-DEC-99.SDR DALA2019041652465Floor Support · corrodedCORROSION FLOOR BEAM +Y1162 LOC.FR68 TO FR69 AT AFT GALLEY AREA (1 EA). REPLACED FLOOR BEAM AND FASTENERS +Y1162 LOC. FR.68 TO FR.69 AT AFT GALLEY AREA AS PER SRM A319 51-72-11 AND DRAWING D53472780.SDR DALA2019041602469Floor Support · corrodedCORROSION FLOOR BEAM LOC.FR66 TO FR68 L/H SIDE AT LEVEL + Y1292 AT AFT GALLEY AREA (1 EA). REPLACED FLOOR BEAM AND FASTENERS LOC. FR.66 TO FR.68 L/H SIDE AT LEVEL +Y1292 AFT GALLEY AREA AS PER SRM A319 51-72-11 AND 51-42-11.SDR DALA2019041502468Floor Support · corrodedCORROSION FLOOR BEAM +Y1292 LOC.FR64 TO FR66 AT AFT GALLEY AREA (1 EA). REPLACED FLOOR BEAM AND FASTENERS LOC. ON +Y1292 FR.64 TO FR.66 AT AFT GALLEY AREA AS PER SRM A319 51-72-11 AND 51-42-11.SDR DALA2019041632463Floor Support · corrodedCORROSION CENTER FITTING LOC FROM FRAME 66 TO FRAME 68 AT LEVEL STR 23 R AT AFT GALLEY AREA (1 EA). REPLACED CENTER FITTING LOC FROM FR 66 TO FR 68 AT LEVEL STR 23K AT AFT GALLEY AREA ASPER A319 SRM 51-72-11 AND DRAWING #D53480508.SDR DALA2019041302461Floor Support · corrodedCORROSION FLOOR BEAM +Y254 LOC.FR12 TO FR24 FWD GALLEY AREA (1 EA). REPLACED FLOOR BEAM +Y254 LOC. FR 12 TO FR 24 FWD GALLEY AREA AS PER A319 SRM 51-72-11 AND DRAWINGS D53112816 RELEASE DATE 08-JAN-97, D53110920 RELEASE DATE 07-DEC-99 AND D53110984.SDR DALA2019041522460Floor Support · corrodedCORROSION FLOOR BEAM -Y765 FROM FR 12 TO FR 24 FWD GALLEY AREA ( 1 EA). REPLACED FLOOR BEAM -Y765 FROM 12 TO FR 24 FWD GALLEY AREA (1E/A ) AS PER A319 SRM 51-72-11 AND DWG D53112812.SDR DALA2019041102386Floor Support · corrodedCORROSION FLOOR BEAM +Y512 LOC FROM FR 67 TO FR 70 AT AFT GALLEY AREA. REPLACED FLOOR BEAM +Y512 LOC FROM FR 67 TO FR 70 AT AFT GALLEY AREA AS PER A319 SRM 51-72-11 AND DWG #53472780.SDR DALA2019041102383Floor Support · corrodedCORROSION FLOOR BEAM -Y1292 FROM FR 12 TO FR 24 FWD GALLEY AREA. REPLACED FLOOR BEAM -Y1292 FROM FR 12 TO FR 24 FWD GALLEY AREA.SDR DALA2019040902323Floor Support · corrodedCORROSION FLOOR BEAM -Y189 LOC. FR20 TO FR24 IN PASSENGER CABIN (1 E A). REPLACED FLOOR BEAM AND FASTENERS -Y189 LOC. BTW FR20 TO FR24 IN PASSENGER CABIN ASPER SRM A319 51-72-11 AND DRAWING #D5311406.SDR DALA2019040872293Floor Support · corrodedCORROSION ON FLOOR BEAM +Y1292 LOC. FR12 TO FR24 FWD GALLEY AREA ( 1 EA). EVALUATED FLOOR BEAM +Y1292 LOC FR 12 TO FR 24 FWD GALLEY AREA AND FOUND WITHIN LIMITS AS PER A319 SRM 53-00-15-101 STEP 2, F1601 SHEET 1 MEASUREMENT OF REWORKED AREA P1:L=2.237" W=0.368SDR DALA2019040752266Lens · damagedF/A REPORTS 2B & 3B FWD LWR EMERGENCY LIGHTS LENS PUSHED IN, REPOSITIONED ROW 2 LIGHT INTO PROPER POSITION & REPLACED BROKEN LIGHT ASSY @ ROW 3SDR DALA2017060904615Box Beam · crackedRIGHT SIDE BOX BEAM FLANGE AT FR43 WHEEL WELL LOCATION 3RD HOLE FORWARD FROM AFT 1/4" HOLE CRACKED. SEE NR FOR ADDITIONAL INFORMATION 030-0001:5310-01450-01/001 00142 REPAIR COMPLETE PER 5310-0145-02 IN ACCORDANCE WITH SB A320-53-1251 REV 1.SDR DALA2016102507548Battery Pack · no testEMERGENCY LIGHT TEST, EPSU L FWD FAULTED, R & R EPSU BATTERY PACKSDR DALA2016071405310Battery Pack · inoperativeFWD EPSU BATTERY FAULTED. REPLACED THE BATTERY.SDR DALA2016010500079Wire · damagedEMERGENCY LIGHT AT ROW 6 INOPERATIVE, REPAIRED WIRE.SDR DALA2015051603296Battery Pack · inoperativeFOUND ON CIDS, EPCU EMERGENCY BATTERY AFT LIGHT, REPLACED BATTERY, 13WL.SDR DALA2015040502664Track · dirtyDOOR 3L SLIDE UNARMED IN FLIGHT LEVER WILL NOT STAY IN PLACE. FOUND A PLASTIC PLATE COVERING THE LT SIDE TRACK OF BOTTOM DOOR LATCH. CLEAN TRACK.SDR DALA2014101605570Connector · damagedSEAT MOUNTED EMERGENCY LIGHTS INOPERATIVE. INSTALLED NEW CONNECTORS AND SOCKETS . OPS CHECKED OK. OK FOR SERVICE.SDR DALA13042043137Connector · malfunctionedEMERGENCY LIGHT TEST BUTTON ON CIDS PANEL INOP. RESET RIBBON CONNECTOR ON F/A PANEL. EMERGENCY LIGHTS TEST OK.SDR DALA13041353137Lug · gougedFWD CARGO DOOR LOCK FITTING NR 2 FWD LUG GOUGED. REMOVED DAMAGE IAW SRM 51-73-00. CHECKED LIMITS, FWD LUG REMAINING THICKNESS 0.492" & AFT LUG REMAINING THICKNESS 0.486" WITHIN LIMITS IAW SRM 53-26-00, FIG 101. PERFORMED DVI, NO OTHER DAMAGED FOUND IAW SRM SDR DALA13041343137Lug · gougedFWD CARGO DOOR LOCK FITTING NR 3 FWD LUG GOUGED. REMOVED DAMAGE IAW SRM 51-73-00. CHECKED LIMITS, O/D OF LUG REMAINING THICKNESS OF 0.480" FWD FACE OF LUG REMAINING THICKNESS OF 0.635" WITHIN LIMITS IAW SRM 53-26-00, FIG 101. PERFORMED DVI, NO OTHER DAMAGE SDR DALA13039523137Sill · corrodedAFT CARGO COMPARTMENT LOWER ENTRANCE BETWEEN FR56 TO FR59 UPPER SURFACE DOOR SILL HAS CORROSION. REMOVED CORROSION IAW SRM 51-73-00. PERFORMED DVI OF REWORKED AREA IAW NTM 51-10-01 NO DEFECTS NOTED. HFEC REWORKED WORKED IAW NTM 51-10-08. NO DEFECTS NOTED. SDR DALA13039183137Stringer · corrodedAFT CARGO COMPT BILGE AREA BETWEEN FR59 TO 60, S43L, STRINGER AND RIVETS BUCKTAIL HAS CORROSION.SDR DALA13038803137Floor Panel · damagedAFT CARGO FLOOR PANEL 162EF HAS MULTIPLE DENTS & SCRATCHES. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038793137Floor Panel · damagedAFT CARGO FLOOR PANEL 151DE HAS MULTIPLE DENTS & CRACKED. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038783137Floor Panel · damagedAFT CARGO FLOOR PANEL 162BF HAS MULTIPLE DENTS & PUNCTURED. FABRICATED FLOOR PANEL IAW SRM 53-02-00 FIG 209, DWG 3D25-40532 AND INSTALLED.SDR DALA13038773137Floor Panel · damagedAFT CARGO FLOOR PANEL 151FE HAS MULTIPLE DENTS & PUNCTURED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209, DWG 3D25-40532 AND INSTALLED.SDR DALA13038763137Floor Panel · damagedAFT CARGO FLOOR PANEL 151TG HAS MULTIPLE DENTS & PUNCTURED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209, DWG 3D25-40532 AND INSTALLED.SDR DALA13038753137Floor Panel · crackedAFT CARGO FLOOR PANEL 162CF CRACKED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209, DWG 3D25-40532 AND INSTALLED.SDR DALA13038743137Floor Panel · crackedAFT CARGO FLOOR PANEL 161BF CRACKED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209, DWG 3D25-40532 AND INSTALLED.SDR DALA13038733137Floor Panel · damagedAFT CARGO FLOOR PANEL 152TG DAMAGED. FABRICATED IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532 AND INSTALLED.SDR DALA13038723137Floor Panel · dentedAFT CARGO FLOOR PANEL 162FF HAS MULTIPLE DENTS. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532. INSTALLED.SDR DALA13038713137Floor Panel · dentedAFT CARGO FLOOR PANEL 151AE HAS PREVIOUS REPAIR & MULTIPLE DENTS. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532. INSTALLED.SDR DALA13038703137Floor Panel · dentedAFT CARGO FLOOR PANEL 161CF HAS PREVIOUS REPAIR & MULTIPLE DENTS. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532. INSTALLED.SDR DALA13038693137Floor Panel · dentedAFT CARGO FLOOR PANEL 152UG HAS PREVIOUS REPAIR & MULTIPLE DENTS. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25 40532. INSTALLED.SDR DALA13038683137Floor Panel · damagedAFT CARGO FLOOR PANEL 161EF HAS PREVIOUS REPAIRS & MULTIPLE DENTS. FLOOR PANEL FABRICATED SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038673137Floor Panel · damagedAFT CARGO FLOOR PANEL 161FF HAS PREVIOUS REPAIR & MULTIPLE DENTS. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038663137Floor Panel · damagedFWD CARGO FLOOR PANEL 131CF HAS PREVIOUS REPAIR & MULTIPLE DENTS & CRACKED. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038653137Floor Panel · damagedFWD CARGO FLOOR PANEL 131BF HAS 3EA PREVIOUS REPAIR & MULTIPLE DENTS. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038643137Floor Panel · dentedAFT CARGO FLOOR PANEL 151BE HAS PREVIOUS REPAIRS, MULTIPLE DENTS & CRACKED. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038633137Floor Panel · dentedAFT CARGO FLOOR PANEL 151VG HAS PREVIOUS REPAIRS & MULTIPLE DENTS. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038623137Floor Panel · damagedAFT CARGO FLOOR PANEL 151GE HAS MULTIPLE DENTS & PUNCTURED. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038613137Floor Panel · damagedAFT CARGO FLOOR PANEL 151HE HAS PREVIOUS REPAIR & DAMAGED. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038233137Blanking Plate · corrodedR2 DOOR AFT BLANKING PLATE CORRODED. 2.0 X 0.50". BLANKING PLATE INSTALLED.SDR DALA13038223137Skin · dentedDENT IN FUSELAGE SKIN ON FR 13 S22-23L. DENT FOUND TO BE OUT OF NEARNESS B=0.200" LESS THAN 0.590 IAW SRM 53-11-11, FIG 105. CUT OUT DAMAGED AREA IAW SRM 53-00-11. HFEC IAW NTM 51-10-08, PT6, NO DEFECTS NOTED. FABRICATED AND INSTALLED FILLER, DOUBLER IASDR DALA13038213137Web · corrodedFWD UTILITY AREA FR16, Y-1732 FLOOR WEB CORRODED. REMOVED CORROSION IAW SRM 51-74-00. NO ALLOWABLE DAMAGE LIMITS FOUND IN SRM 53-11-14. R & R FLOOR WEB IAW SRM 51-42-11 & DWG D53112570.SDR DALA13038183137Floor Panel · corrodedAFT CARGO FLOOR PANEL 152YG, HAS SIX FASTENER HOLES & TWELVE FASTENERS CORRODED. REPLACED FLOOR PANEL SCREWS.
Back to N337NB