N355NB
Service difficulty reports · 144
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N355NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N355NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2019120106967Floor Support · corrodedCORROSION LEVEL: 2. CORROSION FLOOR BEAM +Y765 AND BTW FR66 TO FR70 AT AFT GALLEY AREA (SSI:534147). REPLACED FLOOR BEAM +Y765 AND BTW FR 66 TO FR 70 AT AFT GALLEY AREA AS PER SRM A319 51-42-11,51-72-11 AND DRAWING #D534-72000 D534- 74250 ISSUE T MEASURE OF COSDR DALA2019120106966Fitting · crackedCRACK INDICATION ON INTERCOSTAL FITTING IN OPEN FASTENER HOLE AT LEVEL OF DOOR STOP #7 R/H FR16 AT FWD GALLEY AREA (1 EA). REPLACED INTERCOSTAL FITTING LOC AT LEVEL DOOR STOP 7 RH BTW FR 15 TO FR 16 AS PER A319 SRM 51-72-11 AND DRAWING D531-12300.SDR DALA2019100405711Light · malfunctionedAT APPROX 27000 FT F/A REPORTED EMERGENCY LIGHTS CAME ON AND WENT OFF AFTER A SHORT WHILE EMER EXIT LIGHT SWITCH IN ARM POSITION. EMERGENCY CHECK LIGHT OPS CHECK SHOWS NO FAULTS COULD NOT DUPLICATE ANY ISSUES OK FOR SVC.SDR DALA2019080504603Support Ring · crackedNR 2 ENG SUPPORT RING FOUND CRACKED AT 11-12 O-CLOCK POSITION. CLOSED PER ERA 580224-14 SECTION 3 STEP 4. DAMAGE ALLOWED PER AMM 72-54-00-210-002-A INSPECTION OF THE TURBINE CASE, STEP 4A. REVISE LOGPAGE 5501542 TO REMOVE THE PARTS REPLACEMENT REQUIREMENT WITHSDR DALA2018060803912Lens · missingLT OVERWING EXIT SIGN IDENTIFIER MISSING, INSTALLED LT OVERWING DOOR LOWER EXIT IDENTIFIER LENS.SDR DALA2018011700269Box Beam · crackedLEFT BOX BEAM CRACKED IN PRESSURE PLATE LAYER, REPAIRED IAW AMDS 5310-01450-02.SDR DALA2018011700268Box Beam · crackedLEFT BOX BEAM FLANGE FIRST HOLE CRACKED IN FLANGE LAYER. REPAIRED IAWAMDS 5310-01450-02, .SB A320-53-1251 REV 1SDR DALA2018011700267Box Beam · crackedRIGHT BOX BEAM PRESSURE PLATE CRACKED. REPAIRED IAW AMDS 5310-01450-02. IAW SB A320-53-1251, REV 1.SDR DALA2018011700266Box Beam · crackedRIGHT BOX BEAM FLANGE HOLE NUMBER 1 CRACKED IN FLANGE LAYER, REPAIRED IAW AMDS 5310-01450-02. IAW SB A320-53-1251 REV 1SDR DALA2017031402019Connector · unsecureEMERGENCY EXIT OVER THE WING SIGN INOPERATIVE, FOUND CONNECTOR LOOSE INSIDE THE HOUSING. SECURED THE CONNECTOR.SDR DALA2018080304855Doubler · damagedFWD ATG4 ANTENNA DOUBLER FOUND OVER SIZED HOLES IN STRINGERS 41L - 42L BETWEEN FRAMES 29-30 TO BE TRUE AND ROUND AT .200 - .201, DWG 19110, REPAIRED IAW ER/A 553652-14, REV ORIGINALSDR DALA2016012000507Floor Panel · damagedAFT CABIN FLOOR PANEL 261DF IS DAMAGED. REPLACED FLOOR PANEL 261DF WITH NEW PANEL IAW SRM 57-72-00.SDR DALA2016012000506Floor Panel · corrodedAFT CABIN FLOOR PANEL 261FF HAS CORROSION. REPLACED PANEL IAW SRM 51-72-11.SDR DALA2014102005658Wire Harness · inoperativeSEAT MOUNTED EMERGENCY LIGHT INOPERATIVE AT SEAT 4C. INSTALLED NEW LIGHT HARNESS, CONNECTOR AND SOCKETS AT SEAT 4C. OPS CHECKED OK. OK FOR SERVICE.SDR DALA14028223155Wire · missingOVERWING EMERGENCY EXIT HANDLE LIGHT INOPERATIVE RT SIDE. T/S AND FOUND WIRES TO THE LED BULB REMOVED. CONNECTED WIRE TO PROPER POSITION IAW AWM 33-51-00. LIGHT WORKS NORMALLY. OK FOR SERVICE.SDR DALA14018733155Shear Plate · corrodedCORROSION ON SHEAR PLATE FRAMES 69 - 70. REPLACED SHEAR PLATE IAW SRM 51-72-11 AND DWG D53474180.SDR DALA14018723155Shear Plate · corrodedCORROSION ON SHEAR PLATE LOCATED AT FRAMES 69 - 70, REPLACED SHEAR PLATE IAW SRM 51-72-11 AND DWG D53474180.SDR DALA14018303155Floor Support · corrodedCORROSION ON FLOOR SUPPORT BETWEEN FRAMES 18-20 -Y254. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53111462.SDR DALA14017343155Fitting · corrodedCORROSION ON CENTER FITTING IN CUTOUT OF L2 DOOR BETWEEN FRAMES 66 & 68 S23L. REPLACED CENTER FITTING IAW SRM 51-72-11 AND DWG D53480009 SSI 534136.SDR DALA14017063155Web · corrodedCORROSION ON WEB AT FRAME 71 BETWEEN STRINGERS 27 - 32R ACCESS DOOR 312AR CUTOUT. REPLACED WEB IAW SRM 51-72-11 AND DWG D53571510.SDR DALA14017043155Sill · corrodedCORROSION ON AFT PAX CABIN LOWER SILL LOCATED CUT OUT OF L2 DOOR FRAME 66 - 68. REPLACED LOWER SILL IAW SRM 51-72-11 AND DWG D53480505.SDR DALA14017033155Skin · corrodedCORROSION ON WING TOP SKIN BETWEEN RIBS 19 & 20. REWORKED AND FOUND WITHIN LIMITS IAW SRM 57-21-11.SDR DALA14017023155Floorbeam · corrodedCORROSION ON AFT PAX CABIN FLOORBEAM Y1292 FRAME 66. REPLACED FLOORBEAM IAW SRM A319 51-72-11 AND DWG D53472815.SDR DALA14017013155Floor Support · corrodedCORROSION ON AFT PAX CABIN FLOOR SUPPORT Y1162 BETWEEN FRAMES 68-69. REPLACED FLOOR SUPPORT IAW SRM A319 51-72-11 AND DWG D53472780.SDR DALA14017003155Floorbeam · corrodedCORROSION ON AFT PAX CABIN FLOORBEAM BETWEEN Y1292 - Y1162, FRAME 67. REPLACED FLOORBEAM IAW SRM 51-72-11 AND DWG D53472780.SDR DALA14016983155Floor Support · corrodedCORROSION FOUND ON FLOOR SUPPORT -Y765 FRAMES 64 - 66. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472816.SDR DALA14016973155Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y765 FRAMES 66 - 70. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472780.SDR DALA14016963155Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y1292 FRAMES 64 - 66. REPLACED FLOOR SUPPORT IAW SRM A319 51-72-11 AND DWG D53472816.SDR DALA14016953155Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y1162 FRAME 68 - 69. REPLACED FLOOR SUPPORT IAW SRM AND DWG D53472780.SDR DALA14016943155Fitting · corrodedCORROSION ON CENTER FITTING AT R1 DOOR LOWER SILL AREA. REPLACED CENTER FITTING IAW SRM 51-72-11 AND DWG D5311209.SDR DALA14016933155Fitting · corrodedCORROSION ON CENTER FITTING AT L1 DOOR LOWER SILL AREA. REPLACED CENTER FITTING IAW SRM 51-72-11 AND DWG D53112109.SDR DALA14016923155Floor Support · corrodedCORROSION ON FLOOR SUPPORT BETWEEN FRAMES 20 AND 23, Y254. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53112816.SDR DALA14016063155Floor Support · corrodedCORROSION ON AFT PAX CABIN FLOOR SUPPORT LOCATED Y765 BETWEEN FRAMES 66+5"- 68. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472780.SDR DALA14015363155Dummy Rail · corrodedCORROSION ON DUMMY RAIL, AT FRAME 16, Y503. REPLACED DUMMY RAIL IAW SRM 51-72-11 AND DWGS D53112639, AND D53112825.SDR DALA14015353155Floorbeam · corrodedCORROSION ON FLOORBEAM FRAME 16, LEVEL Y765. REWORKED IAW SRM 51-74-00. FOUND WITHIN LIMITS IAW SRM 53-11-15, PARA 4.B, FIG 106 AND APPLIED PROTECTIVE TREATMENT IAW SRM 51-21-11 AND SRM 51-23-11.SDR DALA14015343155Floor Support · corrodedCORROSION ON FLOOR SUPPORT BETWEEN FRAMES 20 AND 21 Y-189. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D531 11406.SDR DALA14022753155Skin · dentedDENT ON EXTERNAL FUSELAGE SKIN LOCATED BETWEEN FR 16 TO FR 17 AND 7.5" BELOW SCUFF PLATE AREA LT SIDE. EVALUATED DENT ON EXT FUSELAGE SKIN LOCATED BETWEEN FR 16-FR 17 AND 7.5" BELOW SCUFF PLATE AREA LT SIDE AND FOUND WITHIN LIMITS IAW SRM 53-11-11, TABLE 101SDR DALA14015053155Floor Support · corrodedCORROSION ON FLOOR SUPPORT BETWEEN FRAMES 18 AND 20 Y1292. REWORKED IAW SRM 51-74-00 AND FOUND WITHIN LIMITS IAW SRM 51-11-15, PARAGRAPH 4E, FIG 107, PAGE 121. APPLIED PROTECTIVE TREATMENT IAW SRM 51-21-11 AND SRM 51-23-11.SDR DALA13052063155Connector · damagedEMERGENCY LIGHT AT 14C WIRE CONNECTOR DAMAGE. R & R 14C EMERGENCY LIGHT WIRE HARNESS IAW ESPM 20-33-20. OPS CK GOOD. OK FOR SERVICE.SDR DALA13035913155Power Supply · inoperativeOVERWING EMERGENCY LIGHTS INOPERATIVE. REPLACED POWER SUPPLY IAW AMM 33-50-00.SDR DALA1155863155Door · gougedCATERING REPORTED GOUGE AT DOOR 2L DENT LOCATED APPROX 31" AFT OF DOOR 2L, 16" ABOVE BOTTOM OF DOOR. CUT OUT DAMAGE 1 1/16" HOLE 430466. HFEC AROUND DAMAGE CUT OUT PER A-319 NTM 51-10-08 NO CRACKS INDICATED INSTALLED DOUBLER IAW SRM 53-41-11 430466 REPAIR SDR DALA1155053155Wire Harness · defectiveDURING NON ROUTINE CHECK, FOUND EMERGENCY LIGHT AT SEAT 5C INOPERATIVE. MAINTENANCE REPLACED LONG WIRE HARNESS UNDER SEAT AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1021503155Connector · unsecureDURING EMERGENCY LIGHT TEST FOUND ROW 11 ESCAPE PATH LIGHT INOP, SECURED WIRE CONNECTOR AND TESTED OK.SDR NWAA081323155Epsu · dischargedTHE EMERGENCY PATHWAY LIGHTS FLASHING AFTER LANDING AND ALL THE WAY TO THE GATE. REPLACED EPSU 11WL, TESTS GOOD.
Back to N355NB