N355NW
Service difficulty reports · 185
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N355NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N355NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2021031801532Floor Support · corrodedSHIP 3255 CORROSION FLOOR BEAM -Y1292 LOCATED BTW FR 12 TO FR 24 AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-42-11, 51-72-11. (1757390)SDR DALA2020123104351Psu · no testRT FWD ENTRY DOOR PSU PANEL FAILED TO OPEN ON OXY MASK TEST. CORRECTIVE ACTION: FOUND PSU OXY PANEL MOUNTING SCREWS MISSING. REPLACED SCREWS. TEST OK.SDR DALA2020123104350Psu · no testDURING TEST PSU AT SEAT 32R FAILED TO OPEN. CORRECTIVE ACTION: REPACKED PSU AND PERFORMED SECOND TEST. OPERATIONS CHECK GOOD.SDR DALA2020123004345Psu · no testROW 32RH SIDE PSU PANEL FAILED TO OPEN ON OXY MASK TEST. CORRECTIVE ACTION: ON SECOND TEST PSU PANEL PASSED TEST. OK FOR SERVICE.SDR DALA2020123004344Psu · no testROW 1LH PSU PANEL FAILED TO OPEN ON OXY MASK TEST. CORRECTIVE ACTION: REPACKED PSU. OPERATIONS CHECK GOOD.SDR DALA2020100503279Pressure Deck · crackedRIGHT SIDE FR 35/36 PRESSURE FLOOR PANEL HOLE NR 6 & 7 HAVE HFEC CRACK INDICATIONS. CORRECTIVE ACTION: REPAIRED PER AMDS NR 5311-01171-04B.SDR DALA2019071204192Light · inoperativeLT AFT OVERWING EXIT DOOR PULL HANDLE LIGHT INOP, RELAMPED LT AFT OVERWING EXIT DOOR PULL HANDLE LIGHT.SDR DALA2019061293529Housing · brokenEMERGENCY LIGHT HOUSING BROKEN AT SEAT 12D, REPLACED HOUSINGSDR DALA2019040752279Housing · detachedSEAT 16 DEF EMERGENCY LIGHT HOUSING NOT INSTALLED UNDER SEAT, REPLACED HOUSING ASSEMBLYSDR DALA2019021300948Light · unsecureEMERGENCY LIGHT IN AISLE SEAT 28D LOOSE AND HANGING BY WIRES.SDR DALA2018122407381Light · unsecure(LP# 3993482) SEAT 18D MOUNTED EMERGENCY LIGHT KEEPS FALLING OFF. RESECURED. OPERATION CHECKS OKAY.SDR DALA2018091005535Light · brokenEMERGENCY LIGHT BROKEN 28D. RESECURED LIGHT.SDR DALA2018022001026Housing · damaged11DEF EMERGENCY LIGHT HOUSING DAMAGED, REPLACED THE LIGHT.SDR DALA2017090706751Power Supply · no testFWD EPSU FAILED EMERGENCY LIGHT TEST, REPLACED FWD EPSU.SDR DALA2021041202115Door Frame · crackedSHIP 3255 CRACK INDICATIONS ON FR16L AT HOLES #7, #8, #A, AND #B ABOVE DOOR STOP 7. CORRECTIVE ACTION: REPAIRED PER ER/A 554956-14AD REV.A. (0066446)SDR DALA2019030701526Frame · crackedCRACK INDICATION ON FRAME 16 JOOGLE AREA IN OPEN HOLE NR 5 RIGHT SIDE CRACK DIRECTION: 3 O'CLOCK APPROX AND HOLE NR 6 ABOVE NR 7 DOOR STOP FITTING AT FWD GALLEY AREA; REPLACE DOOR FRAME FR16RH PER PRI 554957-14AD REV 0, REV 1, REV 2 AND ER/A 554957-14AD REV C SDR DALA2017031802182Skin · dentedDENT SKIN BTW FR 80 AND FR 81 STR 1R TO STR 2R AT RUDDER AREA ON UPPER FUSELAGE.SDR DALA2017031802181Skin · dentedDENT SKIN AT FR 79 BTW STR 4L AND STR 5L APPROX ON UPPER FUSELAGE, PERMANENT REPAIR ON THIS AREA AS PER SRM 53-51-11 FIG 20102 PAG 8.SDR DALA2017011000267Wire Harness · disconnectedSEAT EMERGENCY LIGHT INOPERATIVE ROWS 12 AND 19, RECONNECTED AND SECURED HARNESSSDR DALA2016121809960Wire · looseEMERGENCY LIGHT AT SEAT ROW 14 INOPERATIVE, FOUND LOOSE WIRE AT SEAT SPLICE. REPLACED SPLICE.SDR DALA2019030101322Box Beam · crackedCRACK FOUND IN ONE OPEN HOLE OF FUSELAGE CENTER BOX BEAM AT FR43 AND Y1650. FOUND DURING ACCOMPLISHMENT OF NTM 51-10-01-PB 6, PERFORMED TIME LIMITED REPAIR ON FLOOR STRUCTURE SIDE BOX BEAM UPPER FLANGE AT FR 43 LT SIDE ON CENTER WING BOX AS PER PRI N.535313-14SDR DALA2015050303101Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON LOWER SILL AT AFT GALLEY AREA FROM FRAME 66 TO FRAME 68 AND STR 23R, L=1", W=0.50", D=0.003". REPLACED LOWER SILL AT AFT GALLEY AREA FROM FR 66 TO FR 68 AND STR 23R IAW SRM 51-72-11 AND DWG D53480505.SDR DALA2015050303100Skin · corrodedDURING INSPECTION, FOUND CORROSION ON DOUBLER SKIN IN FWD CARGO COMPARTMENT FROM FRAME 27 TO FRAME 28 ON STR 43R L=1.110", W=0.210", D=0.001. REPLACED DOUBLER SKIN IN FWD CARGO COMPARTMENT FROM FRAME 27 TO FRAME 28 ON STR 43R IAW SRM 51-42-11 AND DWG D532315SDR DALA2015050203097Stringer · corrodedDURING INSPECTION, FOUND CORROSION ON STR 41R IN AFT CARGO COMPARTMENT BETWEEN FRAME 58+12" TO FRAME 59+3.5", L=6", W=1.5", D=0.004". MEASURES APPROXIMATELY SSI 534107. REWORKED AREA MECHANICALLY IAW SRM 51-74-00. EVALUATED REWORKED AREA ON STRINGER 41R ISDR DALA2015050203096Web · corrodedDURING INSPECTION, FOUND CORROSION ON WEB FRAME 16 AT FWD GALLEY AREA AND STRINGER 23R L=1.640"; W=0.875"; D=0.002". REPLACED WEB FRAME 12 TO 16 AT FWD GALLEY AREA AND STR 23R IAW SRM 51-72-11 AND DWG NR D53112570.SDR DALA2015050103036Coupling · corrodedCORROSION ON COUPLING IN FWD CARGO COMPARTMENT FROM FRAMES 27 TO 28 ON STRINGER 43R. REPLACED THE COUPLING IAW SRM 51-72-11 AND DWG D53231598.SDR DALA2015043003035Floor Panel · delaminatedDELAMINATED FLOOR PANEL 262EF AT AFT GALLEY AREA. REPLACED THE FLOOR PANEL IAW 53-02-00, PAR 8.H, FIG 209.SDR DALA2015043003034Floor Panel · delaminatedDELAMINATED FLOOR PANEL 221DF AT FWD GALLEY AREA. REPLACED THE FLOOR PANEL IAW 53-12-00, FIG 206.SDR DALA2015043003033Floor Panel · delaminatedDELAMINATED FLOOR PANEL 262BG AT AFT GALLEY AREA. REPLACED FLOOR PANEL IAW 53-02-00, PAR 8.H, FIG 209.SDR DALA2015043003011Floor Panel · delaminatedDELAMINATED FLOOR PANEL 222EF AT FWD GALLEY AREA. REPLACED THE FLOOR PANEL IAW SRM 53-12-00, FIG 101, DIAGRAM 101.SDR DALA2015043003010Floor Panel · corrodedCORROSION ON FLOOR PANEL 221FF AT FWD GALLEY AREA, REPLACED THE FLOOR PANEL IAW AMM 53-42-12.SDR DALA2015042903004Structure · corrodedCORROSION ON LOWER SILL LOCATED BETWEEN FRAME 66 TO FRAME 68 AT STR. 23L AT AFT GALLEY AREA, L=1", W=0.500", D=0.003". REPLACED LOWER SILL LEFT SIDE LOCATED BETWEEN FRAME 66 TO FRAME 68 AT LEVEL STR 23L AT AFT GALLEY AREA IAW STEP 51-72-11 AND DWG D53480505.SDR DALA2016112209100Access Panel · corrodedCORROSION ON ACCESS PANEL 540KB COUNTERSINK HOLES LT WING. REPLACED THE ACCESS PANEL .SDR DALA2015042602983Floor Panel · corrodedCORROSION ON FLOOR PANEL 262FF AT AFT GALLEY AREA. REPLACED THE FLOOR PANEL IAW AMM 53-42-12-400-002-A .SDR DALA2015042602982Stringer · corrodedCORROSION ON STRINGER 43L IN AFT CARGO BAY FRAME 56+11. REPLACED THE STRINGER IAW SRM 51-72-11 AND DWG D53470345.SDR DALA2015042602981Stringer · corrodedCORROSION ON STRINGER 42L IN AFT CARGO BAY BETWEEN FRAMES 56+10 TO 58+9. REPLACED THE STRINGER IAW SRM 51-72-11 AND DWG D53470345.SDR DALA2015042602980Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y1162 BETWEEN FRAMES 67+15 TO 69. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472800.SDR DALA2015042602979Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y1292 BETWEEN FRAMES 64 TO 66+5. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472815.SDR DALA2015042602942Structure · corrodedDURING INSPECTION, FOUND CORROSION ON UNDERFLOOR STRUCTURE SECTION-CONNECTION AT STR 29L AND AT FRAME 67 AT AFT GALLEY AREA, L=3", W=0.200", D=0.003". SSI 534144. REPLACED SECTION-CONNECTION LOCATED ON UNDERFLOOR STRUCTURE AT STR 29L AND AT FRAME 67 AFT GALLSDR DALA2015042502933Web · corrodedDURING INSPECTION, FOUND CORROSION ON WEB FRAME 20 AT FWD GALLEY AREA AND STR 23R L=1.860", W=0.860", D=0.002". SSI 531189. REPLACED WEB, LOCATED BETWEEN FR 20 TO FR 24 AT LEVEL OF STR 23R FWD GALLEY AREA IAW SRM 51-72-11 AND DWG N.D53112783 AND DWG N, DSDR DALA2015042502932Skin · dentedDURING INSPECTION, FOUND DENT ON EXTERNAL SKIN AT LOWER FUSELAGE ON FRAME 69+9" BETWEEN STRINGER 19L TO STR 20L. PERFORMED PERMANENT REPAIR ON EXTERNAL SKIN AT LOWER FUSELAGE AT FR 69+9" BETWEEN STR 19L TO STR 20L IAW SRM 53-41-11 PARA 5.M, FIG 215.SDR DALA2015042502931Shear Tie · corrodedDURING INSPECTION, FOUND CORROSION ON CLEAT IN FWD CARGO COMPARTMENT ON FRAME 32 BETWEEN STR 40R TO STRINGER 41R L=1.115", W=0.310", D=0.001". SSI 532180. REPLACED CLEAT AND FASTENERS LOCATED IN FWD CARGO COMPARTMENT ON FR 32 BETWEEN STR 40R TO STR 41R IAW SDR DALA2015042502930Fitting · corrodedDURING INSPECTION, FOUND CORROSION ON CENTER FITTING AT FWD GALLEY AREA FROM FRAME 16 TO FRAME 20 AND STRINGER 23L L=0.325", W=0.150", D=0.002". SSI 531189, REPLACED CENTER FITTING AND FASTENER LOCATED AT FWD GALLEY AREA FROM FR 16 TO FR 20 AND STR 23L IAW SDR DALA2015042502929Seat Track · corrodedDURING INSPECTION, FOUND CORROSION ON SEAT TRACK +Y1292, FRAME 47 TO 64 EVALUATED AND FOUND OUT LIMITS ON JOB CAR 2500-203 2-DE IN PASSENGER CABIN. REPLACED SEAT TRACK Y1292 FR 47 TO FR 64 IAW SRM 51-72-11 AND DWG: D53472000.SDR DALA2015042502928Dummy Rail · corrodedDURING INSPECTION, FOUND CORROSION ON RAIL DUMMY Y503.2 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 16 L=1.278", W=0.870", D=0.002". SSI 531189. REPLACED RAIL DUMMY Y503.2 LOCATED BETWEEN FR 12 TO FR 16 FWD GALLEY AREA IAW SRM 51-72-11 AND DWG N, D53112825 ANSDR DALA2015042502927Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM +Y512 BETWEEN FR 64 TO FR 67+10" AT AFT GALLEY AREA L=2", W=1", D=0.004". SSI 534147. REPLACED FLOORBEAM +Y512 BETWEE FR 64 TO FR 67+10" AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472815.SDR DALA2015042302901Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y1292 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 24, L=0.178", W=0.055", D=0.001". SSI 531189. REPLACED FLOORBEAM -Y1292 LOCATED BETWEEN FR 12 TO FR 24 SRM 51-72-11 AND DWS D53112812, D53110984 , D5311SDR DALA2015042302900Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y81 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 16, L=0.381", W=0.160", D=0.001". SSI 531189. REPLACED FLOORBEAM -Y81 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 16 AND FASTENERS IAW SRM 51-72-11 AND DWG D5311SDR DALA2015042302899Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y765 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 24, L=1.375", W=0.810", D=0.002". SSI 531189. REPLACED FLOORBEAM -Y765 LOCATED AT FWD GALLEY AREA FROM FR 12 TO FR 24 IAW SRM 51-72-11 AND DWG D53110422.SDR DALA2015042302898Seat Track · corrodedDURING INSPECTION, FOUND CORROSION ON SEAT TRACK -Y765, FRAME 47 TO 64 EVALUATED AND FOUND LIMITS ON JC 2500- 2032-DE IN PASSENGER CABIN. P1, FR 49=3.785", W=0.350", D=0.063", P2 FR.53+12", L=2.603", W=0.348", D=0.043, "P3 FR .62+10", L=4.100", W=0.350", D=0.