What was found
CORROSION ON LOWER SILL LOCATED BETWEEN FRAME 66 TO FRAME 68 AT STR. 23L AT AFT GALLEY AREA, L=1", W=0.500", D=0.003". REPLACED LOWER SILL LEFT SIDE LOCATED BETWEEN FRAME 66 TO FRAME 68 AT LEVEL STR 23L AT AFT GALLEY AREA IAW STEP 51-72-11 AND DWG D53480505. MEASURES AFTER REWORK ARE L=1.747", W=1.043", D=0.048".