N361HA
Service difficulty reports · 65
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N361HA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N361HA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2026023063489Switch · brokenEVAC COMMAND SWITCH BROKEN. GROUNDED - YES. REPLACED SWITCH PER ESPM 20-45-21-01. OPS CHECK PER AMM 23-73-710-804-A. OPS CHECK GOOD.SDR ASAA2025102961510Light · malfunctionedEMERGENCY EXIT LIGHTS REMAINED ILLUMINATED FOR DURATION OF FLIGHT EVEN AFTER CYCLING EMER EXIT LIGHT SWITCH. GROUNDED - YES. PERFORMED OPS CHECK PER AMM 33-50-00-001. OPS CHECK GOOD. NO DEFECTS NOTED. OK FOR SVC.SDR HALA20250611175Bleed Valve · faultedETOPS - BTB DUE TO ECAM AIR ENG 2 BLEED FAULT. 3 RESET ATTEMPTS PER MX GUIDANCE UNSUCCESSFUL. REMOVED AND REPLACED ENG #2 PRESSURE REGULATOR VALVE PER AMM 36-11-52. CONIDITION SAME. FOUND MUSCLE LINE PN: FK18785 CRACKED. REMOVED AND REPLACED LINE NO FAULTS NOTSDR HALA20250606164Rod · damagedETOPS - FOUND #2 ENG OUTBOARD TR HOLD OPEN ROD LEVER DAMAGE. REPLACED #2 ENG OUTBOARD TR HOLD OPEN ROD. OPS CHECK OK. OK FOR SERVICE. PER AMM 78-36-41 P/N A3335-13SDR HALA20250530155Wire · exposedETOPS - 4R JUMPSEAT INTERPHONE CORD HAS EXPOSED WIRE. REMOVED AND REPLACED HANDSET AND CRADLE ASSEMLY PER AMM 23-73-44. OPS CHECK NORMAL. OK FOR SV.SDR HALA20250430117Unknown · odorATB - EXPERIENCED FUMES EVENT ON TAXI OUT AND TROUGH 12,000'. ODOR WAS INTERMITTENT, LASTED 30 MINUTES. INTENSIFIED DURING CLIMB TO 16000'. PERFORMED PACK 1 AND PACK 2 BURN. NO DEFECTS OR ODOR NOTED. GROUND RUN WITH NO DEFECTS OR ODOR NOTED. OK FOR SVC. ( RESDR HALA20250403097Pump · faultedETOPS - APU AFT FUEL PUMP FAULT ON ECAM PAGE. REMOVED AND REPLACED APU AFT FUEL PUMP PER AMM 28-22-52. OPS CHECK AND LEAK CHECK OKAY. OKAY FOR SERVICE.SDR HALA20250331093Valve · faultedATB - ECAM AIR ABNORM BLEED CONFIG. ENG 1 BLEED OFF CAME ON EVERY 2 MINUTES. REMOVED AND REPLACED #1 ENGINE PRV PER AMM 36-11-52. OPS AND LEAK CHECK GOOD AFTER ENGINE ILD RUN. OK FOR SVC.SDR HALA20250217061Bleed Valve · faultedATB - ECAM AIR ENGINE 1AND 2 BLEED FAULT ILLUMINATED CLIMBING. PER TSM 36-11-00-810-856-A , PFR ONLY SHOWS PRV E1-400 1HA ISOL 7HA1 SENSE LINE FAULT FOLLOWED TSM 36-11-81-810-908-A PER STEP 4.A.2 A REPLACED BLEED VALVE PER AMM 36-11-52 OPS AND LEAK CHECK OK RASDR HALA20250207053Generator · faultedETOPS - ELEC GEN 2 FAULT, RESET DID NOT WORK, GEN #2 OFF. 5 MINS LATER ELEC - IDG#1 LO PR IDG 2 TO OFF PER PROCEDURE. REMOVED AND REPLACED #2 I.D.G. PER AMM 24-21-51. LEAK CHECK OPS CHECK GOOD. OK FOR SVC.SDR HALA20250203045Cargo Load Sys · inoperativeETOPS - DURING PDSC FWD CARGO LOADING SYSTEM INOP. FOUND INTERNAL FAIL ON FWD CARGO LOADING SYS OUTSIDE CONTROL PANEL. REMOVED AND REPLACED PER AMM 25-51-74-000-805-A. OPS CHECK GOOD.SDR HALA20250102003Fuel Filter · cloggedETOPS - ENG 1 FUEL FILTER CLOG. REPLACED DETICATED ALTERNATOR STATOR PER AMM 73-21-51-420-056-A. REMOVED/ REPLACED PCU AT #1 ENG AMM 73-21-35. OPS CHECK GOOD. NO FAULT NOTED. PERFORMED HPR NO FAULTS NOTED. OK FOR SVCSDR HALA20241230388Fadec · faultedETOPS - ENG 1 FADEC SYS FAULT. PERFORMED TSM 75-33-00-810-801A. TORQUE MOTOR OF VSV CHANNEL A CONTROLLER FOUND WITHIN LIMITS. VSV CONTROLLER B CHANNEL FOUND OVER LIMIT. PERFORMED TSM 73-21-89-810-810-A DUE TO PFR 732151, MULTIPLE FAULTS SHOWN. R & R NR 1 EECSDR HALA20241230387Fuel Filter · cloggedETOPS - ENG 1 FUEL FILTER CLOG OK TO CONTINUE PER MOC. REMOVED AND REPLACED ENGINE #1 FUEL FILTER ELEMENT PER AMM# 73-11-41.OPS CHECK GOOD .SECURITY CHECK GOOD .OK FOR SERVICE.SDR HALA20241216371Wheel · vibrationTAKEOFF ROLL STOPPED AT 110KTS DUE TO EXCESSIVE VIBRATIONS. STARTED IN NOSE WHEEL AT 90 KTS AND GOT WORSE AT 100 AND 110. BTB. REMOVED AND REPLACED LH/RH NLG WHEEL AND TIRE ASSY PER AMM 32-41-12. SPIN/SECURITY CHECK GOOD. OK FOR SVC.SDR HALA20241211357Hydraulic Line · chafedETOPS - FOUND #1 ENG GREEN EDP PRESSURE AND SUCTION HYD TUBES CHAFFING. SUCTION HYD TUBE DAMAGED AND STATICALLY LEAKING. AWAITING RESOLUTION.SDR HALA20240830246Bleed Air Sys · faultedATB - IMMEDIATELY AFTER ECAM FOR ENG #1 BLEED FAULT, F/A & PAX REPORTED STRONG ODOR OF BURN. REPLACED PRESSURE REGULATING VALVE PER AMM 36-11-52. PERFORMED OPS AND LEAK CHECK OF #1 ENGINE PRV. PERFORMED ENGINE IDLE RUN OF EACH ENGINE SEPERATELY. RAN EACH PACKSDR HALA20231113245Unknown · unknownDIV - IN CRZ 2 HRS INTO FLT FA REPORTED ELECTRICAL "HOT" SMELL AT ROW 1 & 2 ACFT LEFT. FO NOTED SAME BUT AT ROW 2 ACFT RIGHT IFE & GALLEY ELECTRIC EQUIPMENT TURNED OFF PER MOC. OVHD BINS INSPECTED. [CONT FROM LP# 965730/2] NOTING STRONG DIRTY SMELL EMANATING SDR 2023FA0000517Seat Track · corrodedHAWAIIAN AIRLINES N361HA CURRENTLY IN SIAEC FOR MAINTENANCE. ROUTINE INSPECTION FOR TASKCARD 330-53-HWI-13 FOUND SEAT TRACK CORROSION ON LH, Y1959, FR53.2-54. THE SEAT TRACK WAS REPLACED AS PER SRM.SDR 2023FA0000516Seat Track · corrodedHAWAIIAN AIRLINES N361HA CURRENTLY IN SIAEC FOR MAINTENANCE. ROUTINE INSPECTION FOR TASKCARD 330-53-HWI-13 FOUND SEAT TRACK CORROSION ON LH, Y1959, FR53.2-54. THE SEAT TRACK WAS REPLACED AS PER SRM.SDR 2023FA0000515Seat Track · corrodedHAWAIIAN AIRLINES N361HA CURRENTLY IN SIAEC FOR MAINTENANCE. ROUTINE INSPECTION FOR TASKCARD 330-53-HWI-14 FOUND SEAT TRACK CORROSION ON RH, Y-1959, FR40-47. THE SEAT TRACK WAS REPLACED AS PER SRM.SDR 2023FA0000514Seat Track · corrodedHAWAIIAN AIRLINES N361HA CURRENTLY IN SIAEC FOR MAINTENANCE. ROUTINE INSPECTION FOR TASKCARD 330-53-HWI-13 FOUND SEAT TRACK CORROSION ON RH, Y-1959, FR47-53.2. THE SEAT TRACK WAS REPLACED AS PER SRM.SDR 2023FA0000513Seat Track · corrodedHAWAIIAN AIRLINES N361HA CURRENTLY IN SIAEC FOR MAINTENANCE. ROUTINE INSPECTION FOR TASKCARD 330-53-HWI-13 FOUND SEAT TRACK CORROSION ON RH, Y-450, FR47-53.2. THE SEAT TRACK WAS REPLACED AS PER SRM.SDR HALA2023062000130Unknown · unknownETOPS - AFTER LANDING APU FAULT AUTO SHUTDOWN, TRIED 2 MORE TIMES NO START, SAME FAULT. REMOVED AND REPLACED APU STARTER - MOTOR. OPS CHECK, LEAK CHECK GOOD WORK PERFORMED IAW AMM 49-42-51-000-801-A OK TO RETURN TO SERVICESDR HALA2023052600114Unknown · unknownETOPS - FOUND #1 ENG, GREEN HYD. PUMP LEAKING. REMOVED AND REPLACED #1 ENG, GREEN HYD. PUMP PER AMM 29-11-51. LEAK CHECK GOOD. OK FOR SVC.SDR HALA2023051500108Blade · faultyETOPS - LEFT ENGINE FAN BLADE #15 HAS DAMAGE ON CONCAVE SIDE 135MM FROM L/E AND 215 MM FROM TIP. 142% DEFELCTION. REF T/C A2020-06-16-PART01. REPLACED #15 FAN BLADE ON #1 ENG PER TASK CARD 330-723100R7-1-1.SDR HALA2023050500102Idg · faultyETOPS - ELEC IDG 1 OIL LO PR PER ECAM IDG1 SELECTED OFF. FOUND METAL SHAVINGS IN IDG OIL REMOVED AND REPLACED IDG PER AMM 24-21-51 OPS CHK LEAK CHECK GOOD. OK FOR SVCSDR HALA2023012300012Fire Loop · faultedETOPS - APU FIRE LOOP B FAULT. REMOVED & REPLACED APU FIRE LOOP B PER A330 AMM 26-13-15. TEST OK.SDR HALA2022110700338Light · detachedSHIP 361 FLOOR PATH LIGHTING STRIP NEAR FWD GALLEY CHILLER DOOR DETACHED FROM FLOOR. CORRECTIVE ACTION: REPLACED FWD GALLEY GLOW STRIP DAMAGED PORTION. (9763381)SDR HALA2022090600256None · noneCREW REPORTED ON APPROACH THAT THEY HAVE GREEN HYD SYS FAILURE, DECLARING EMERGENCY. ECAM G SYS LEAK QUANTITY IN YELLOW BAND. FOUND #1 ENGINE GREEN SYSTEM PRESSURE AND SUCTION LINES CHAFED. REMOVED AND REPLACED BOTH LINES PER AMM 29-11-49-400-809-A. OPS CHECK SDR HALA2022040600085None · noneETOPS - ECAM APU GEN FAULT AFTER APU START UP ON PDC // TROUBLESHOT PER TSM 24-20-51-810-804-A. NEED TO REPLACE GLC-APU (3XS). CJC 1865671 05APR22 REMOVED AND REPLACED APU GENERATOR LINE CONTACTOR (3XS) PER AMM 24-23-55. OPS CHECK PENDING. 1932291 05APR22. PSDR HALA2022011800025Light · abnormalSHIP 361 EXIT SIGN NOT ILLUMINATED AT 3R AND 4R DOOR. CORRECTIVE ACTION: OPERATIONAL TEST AND OK. (8452563)SDR HALA2021121600189Valve · inoperativeETOPS - LINE SERVICE REPORTED UNABLE TO PUMP FUEL // FCMC FAULTING L OUTER TANK INLET VALVE FAILED OPEN. (500QU1). REMOVED AND REPLACED L OUTER TANK FUEL INLET VALVE ACTUATOR PER AMM 28-25-57. OPS AND SECURITY CHECK GOOD. NO FAULTS NOTED. OK FOR SVC. SDR HALA2021112300210None · noneSHIP 361 FWD GALLEY PHOTOLUMINESCENT LIGHTING STRIP IS DETACHED. CORRECTIVE ACTION: REATTACHED FWD GALLEY PHOTOLUMINESCENT LIGHTING STRIP. (7744650)SDR HALA2021101300171None · noneSHIP 361 - ATO - DUE TO WRONG INDICATION ON FMA. ECAM 'NAV R CAPT STATIC FAULT'. MAX IAS AT ABORT LESS THAN 70 KTS. CORRECTIVE ACTION: NO CURRENT FAULT. LAST LEG 'NAV R CAPT STATIC FAULT'. PERFORMED LAND CAT 3 CAPABILITY TEST. INSPECTED STATIC PORT. NO DEFECTSSDR HALA2021100400149None · noneSHIP 361 3R EXIT PLACARD BY SEAT POCKET CAME OFF. CORRECTIVE ACTION: RESECURED 3R EXIT PLACARD LENS. (4492052)SDR HALA2021092000120Exciter · faultedETOPS - ON LANDING - APU AUTOSHUTDOWN APU FAULT APU INOP -3 START ATTEMPTS // TROUBLESHOT PER A330 TSM 49-41-00-810-812-A.CMM FAULTS IGNITION. EXCITER AND IGNITERS. R/R IGNITION EXCITER PER A330 AMM 49-41- 38. CHANGED IGNITERS PER A330 AMM 49-41-38. ASDR HALA2021091300132Panel · damagedSHIP 361 621GB PANEL (F57450561009) WITH AN AREA OF DAMAGE THAT EXCEEDS THE REPAIRABLE DAMAGE LIMITS. CORRECTIVE ACTION: REPAIR PANEL REF PRI 593971-14 AND ERA 593971-14. (1945680)SDR HALA2021090800131Transducer · corrodedNR 2 ENGINE FWD AND AFT FIRE BOTTLE PRESSURE TRANSDUCERS CORRODED TO THE POINT OF FAILURE. CORRECTIVE ACTION: REMOVED AND REPLACED FIRE BOTTLES REF A330 AMM 26-21-41. (1940288)SDR HALA2021090700128Actuator · not reportedSHIP 361 REPLACE L WING SLAT OTBD ROTARY ACTUATOR PER AA 2781-01050-04A THIS IS AN RII PROCEDURE REFER TO TOPP 40-30-05. REPLACEMENT OF GEARED ROTARY ACTUATOR IS REQUIRED PRIOR TO FURTHER FLIGHT. AD 2019-19-06. CORRECTIVE ACTION: SCEPTRE LOG PAGE ENTERED FOR SSDR HALA2021060400086Unknown · odorSHIP 361 DURING INITIAL CLIMBOUT NOTICED STRONG DIRTY SOCK ODOR COMING FROM A/C VENTS IN COCKPIT. NO VISIBLE SMOKE. CABIN DID NOT NOTICE ODOR. CORRECTIVE ACTION: RAN APU. CHECKED APU COMPARTMENT, INLET AND EXHAUST. NO LEAKS AND APU OIL LEVEL OK. OBSERVED HIGH SDR HALA2021031000048Reflector · unsecureSHIP 361 F/C FLOOR GALLEY FLOOR REFLECTOR STRIP IN FWD GALLEY IN FRONT OF CARTS NEED TO BE SECURED. CORRECTIVE ACTION: SECURED F/C FLOOR GALLEY FLOOR REFLECTOR STRIP. (6779189)SDR HALA2021030500035Slide · low pressureSHIP 361 CHECK SLIDE PRESSURE FOR 1 R DOOR ON FAP. CORRECTIVE ACTION: REMOVED AND REPLACED 1R SLIDE. (6779131)SDR HALA2021022200020Light · detachedSHIP 0361 EELS LIGHT STRIP IN THE FWD GALLEY IS COMING OFF OF FLOOR. CORRECTIVE ACTION: RE-SECURED EELS LIGHT STRIP. (7272283)SDR HALA202006210126Cover · damagedOPEN - POSSIBLE DAMAGE AFT CARGO DOOR ACCESS COVER PANEL. 822BR. REPAIR IN WORK.SDR HALA2020030900055Cids · malfunctionedEXIT SIGN PLACARD ABOVE DOOR 3R STAYS ON. // RESET CIDS ALL LIGHTS AT 3R DOOR OPS NORMAL. OK FOR SVC.SDR HALA2019101600417Gcu · malfunctionedETOPS SIGNIFICANT SYSTEM - POWER TRANSFER HARSH/ABRUPT WHEN GEN #2 COMES ON/OFFLINE. IE, WHEN ENG 2 IS STARTED AND SHUTS OFF. // INFO NOTED. REMOVED AND REPLACED #2 GCU PER AMM 24-22-34. BITE TEST PASS. RAN #2 ENGINE. NO DEFECTS NOTED. OK FOR SVC.SDR HALA2019100210153Door Seal · cutRETURNED TO DEPARTURE DUE TO CABIN PRESSURE ECAM AND RED MASTER WARNING LIGHT APPEARED, CLIMBING THROUGH FL 380. CABIN ALTITUDE WAS 10,000 AND CLIMBING WITH BOTH OUTFLOW VALVE CLOSED. DESCENDED TO 10,000. FOUND THE AFT CARGO DOOR SEAL HAD A CUT ON THE OUTSIDESDR HALA2019093000390Door Seal · cutATB: CAB PRES ECAM AND RED MASTER WARNING LIGHT APPEARED CLIMBING THROUGH FL380. CABIN ALTITUDE WAS 10000 AND CLIMBING WITH BOTH OUTFLOW VALVES CLOSED. DESCENDED TO 10000. // FOUND AFT CARGO DOOR SEAL HAD A CUT ON THE OUTSIDE. UPON PRESSURIZATION, REVEALED AIRSDR HALA201908098385Gcu · faultyETOPS - #2 GEN FAIL ON DECENT UNABLE TO RESET // REMOVED AND REPLACED GCU (1XU2) PER AMM 24-22-34 OK FOR SVC UNIT, GCU-GENER OFF 30-2420-9-0002 15691 ON 33-2423-9-0007 08055