N36272
Service difficulty reports · 55
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N36272' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N36272' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026101520371Battery Pack · no testEMERGENCY LIGHT BATTERY PACK AT M1672 FAILED A CAPACITY CHECK. REMOVED & REPLACED BATTERY PACK IAW AMM 33-51-06-960-805, OPS CHKD GOOD.SDR CALA2026101520370Battery Pack · no testEMERGENCY LIGHT BATTERY PACK AT M1694 FAILED A CAPACITY CHECK. REMOVED AND REPLACED BATTERY PACK IAW AMM 33-51-06-960-805, OPS CHKD GOODSDR CALA2026080318219Shutoff Valve · faultedBURNING ODOR ON TO LT DUCT PRESS 85. RT DUCT PRESS 45, PERFORMED WALK AROUND, NO EXTERNAL FINDINGS NOTED. C/W TASK 05-51-26-800-801-C1 CONDITIONAL INSPECTIONS FOR SMOKE IN CABIN. FOUND NO FURTHER INDICATIONS OF BURNING ODOR. CONTINUED TO TROUBLESHOOTING LT DSDR CALA2026071617845Sign · inoperativeRIGHT AFT OVERWING LOWER EMERGENCY SIGN LIGHTS ARE INOP. EMERGENCY LIGHTS - OPERATIONAL CHECK EMERGENCY LIGHTS OPERATIONAL CHECK - REPLACED EXIT SIGN ASSY AT RIGHT OVERWING DOOR. REF AMM 33-51-01-960-802. OPS CHECK GOOD.SDR CALA2026050415926Unknown · odorBURNING ODOR REPORTED BY FA AFTER TOUCHDOWN. LOCATED IN AFT GALLEY. CREW REPORTS ODOR FROM AFT GALLEY NO SMOKE. DISAPATED AFTER LANDING. OVENS IN AFT GALLEY NEVER USED INFLIGHT. BREAKERS IN AFT GALLEY NONE FOUND OPEN. NO ODOR DURING START OF TROUBLESHOOTING ASDR CALA2026031614596None · noneBIRD STRIKE CAPT WINDSCREEN, INSPECTED CRAFT FOR DAMAGE, NO DAMAGE TO REPORT, CLEANED BIRD DEBRIS AND BLOOD FROM WINDSHEILD, RADOME AND CROWN CLOSEST TO CAPT WINDSHEILD REF AMM 05-51-18-210-801.SDR CALA2026012813419Battery Pack · faultedEMERGENCY LIGHT AFT OF AFT EMERGENCY EXIT ON RT SIDE AND LIGHT AFT OF RT WING ON FUSALAGE. RELAMP EMERGENCY LIGHT OF AFT EMERGENCY EXIT ON RH SIDE AND LIGHT AFT OF RH WING TO FUSELAGE IAW AMM 33-51-03 NOT WORK AT THIS TIME. AFTER TROUBLESHOOTING PER WDM 33-51-SDR CALA2025110310834Unknown · odorON TAKE OFF ROLL ABOVE 100KT, SMELLED STRONG OIL ODOR WITH HYD LEVELS WELL BLOW 100% AFT FLAP UP PERFORMED SMOKE/ODOR INSPECTION IAW AMM TASK 05-51-26-800-801-C1 UP TO STEP C SUBSTEPS (2)(E)(4) WITH APU RUNNING. NO ODOR NOTED. CONTINUED AMM TASK 05-51-26-80SDR CALA2025102710584Regulator · faultedCHIME QAR ALERTING RIGHT *DUCT PRESSURE < 29*. RT SIDE HAS BEEN RUNNING 10+ PSI LOWER THAN LT SIDE DURING HIGH N1 (5TH STAGE) OPS FOR A FEW LEGS NOW. PERFORMED ENG BLEED AIR SYS HEALTH CHK ON ENG NR 2 IAW AMM TASK 36-11-00-700-801, & FOUND PC LESS THAN 20 PSDR CALA2025041703939Window Frame · crackedREF EA 5310-08195 REV B OP 004 STEP 26 - CRACK FOUND ON 3RD LOWER FASTENER HOLE AT RT WINDOW FRAME #3 AFTER REAM UP TO PRE COLD WORK DIMENSION (0.300"). ACCOMPLISHED CATEGORY B REPAIR AT RH SIDE NR 3 WINDOW FRAME E-F POST AS PER EC/RA 5310-08554 PART 1. PERSDR CALA2025041703938Skin · crackedEXTERNAL POWER RECEPTACLE SHOW SMALL CRACK AROUND A RIVET ON THE AFT DOUBLER OF THE PERIMETER ABOUT HALF WAY DOWN. ACCOMPLISHED ELECTRICAL GROUND POWER RECEPTACLE SURROUND DOUBLER REPAIR IN REF TO EC/RA 5310-08556.SDR CALA2025041503856Window Frame · crackedFOR SDR TRACKING PURPOSES. REF EA 5310-08195 OP 003 LH SIDE NO. 3 WINDOW FRAME POST PERMANENT REPAIR. (REF AAR N/R 9960183) REFERENCE EA 5310-08195 REV B OP 003 SEQ#1205. PERMANENT REPAIR ACCOMPLISHED AS PER ROUTINE CARD SEQ NO. 1205 (EA 5310-08195 REV B SDR CALA2025041403771Skin · crackedCRACK FOUND AT LEFT HORIZONTAL STABILIZER LOWER SKIN AT STAB. STA 157.10, 32" FROM FRONT SPAR , I/B ROW.CRACK LENGTH : 0.406". INSTALLED, INSPECTED, AND SUBMITTED SSFR. NO CRACK NOTED DURING C-SCAN INSPECTION. REMOVED AND REPLACED PER SRM 55-10-01-2R-11 REPSDR CALA2024121003052Retainer · damagedEXIT ROW COVER LOOSE AT 21ABC NEEDS COVER ASSY RETAINER HARDWARE REF IPC 52-22-51-28 DETAIL N FLAGGED AS SDR. ON SHEET 7 ITEM (-430) PLUS HARDWARE.SDR CALA2024121003051Cover · brokenEXIT ROW COVER MISSING AT 21DEF NEEDS RETAINER AND HARDWARE FOR COVER STUD. REF IPC 52-22-51-28 NEW COVER IS LOCATED ON SEAT BOTTOM OF SEAT 21F. EXIT HANDLE AND OUTER COVER HAS BEEN DISASSEMBLED TO GAIN ACCESS FLAGGED AS SDR ITEM 430 (00-0593-3-1637). TO INNERSDR CALA2024112902979Battery Pack · no testEMERGENCY LIGHTS ON SEAT ROWS 7-14 ABC DO NOT COME ON. SUPPORT TASK NSA EMX NR 00158 REMOVED THE BATTERY FROM BATTERY CHARGER AND INSTALLED SERVICEABLE BATTERY PACK IAW B737 AMM 33-51-06-360-805. OPERATION CHECK GOOD IAW B737-800 AMM 33-51-00-720-801. DATA WASSDR CALA2024112902978Battery Pack · no testVARIOUS EMERGENCY LIGHTS OUT (NOT ON) THROUGHOUT THE CABIN SUPPORT TASK NSA EMX NR 00157 EMERGENCY LIGHT BATTERY M02267 FAILED TO CHARGE/BATTERY PACK REPLACEDSDR CALA2024111102815Seat Track · damaged-F.S. 540 L/H I/B SEAT TRACK HAS WEAR DAMAGE MARKED W/TAPE. SUPPORT TASK NSA EMX N/R 00101SDR CALA2023100302928Fitting · crackedB737-57-4-1262 SHEAR FITTING AT STATION 540 AND RBL 6.14 IS CRACKED SUPPORT TASK NSA EMX NR 00070 REMOVED AND REPLACED SHEAR FITTING AT STATION 540 AND RBL 6.14 INSPECTED IAW SRM 51-40-02 AND BAC DWG 111A2000 REV ORIGINALSDR CALA2023100302927Fitting · crackedB737-57-4-1262 SHEAR FITTING AT STATION 540 AND RBL 32.40 IS CRACKED SUPPORT TASK NSA EMX N/R 00072 REMOVED AND REPLACED SHEAR FITTING AT STATION 540 AND RBL 32.40 N/R 5429202, AND INSPECTED IAW B737-800 SRM 51-40-02 AND BAC DWG 111A2000 REV ORIGINAL.SDR CALA2023100302926Fitting · crackedB737-57-4-1262 SHEAR FITTING AT STATION 540 AND RBL 15.04 IS CRACKED SUPPORT TASK NSA EMX N/R 00071 REMOVED AND REPLACED SHEAR FITTING AT STATION 540 AND RBL 15.04 N/R 5429168, , AND INSPECTED IAW SRM 51-40-02 AND BACDWG 111A2000 REV ORIGINAL.SDR CALA2023100302925Fitting · crackedB737-57-4-1262 SHEAR FITTING AT STATION 540 AND LBL 6.14 IS CRACKED SUPPORT TASK NSA EMX NR 00069 REMOVED AND REPLACED SHEAR FITTING AT STATION 540 AND LBL 6.14 N/R 5429161, IAW B737-800 SRM 51-40-02 AND BAC DWG 111A2000 REV ORIG.SDR CALA2023081802570Unknown · unknownBLEED TRIP OFF LIGHT COMES ON DURING TAKEOFF LIGHT NO. 1 BLEED TRIP OFF DURING T/O. HAPPENED TWICE AT HIGH N1 ABOVE 90 PERCENT. CREW REPORTS BOTH ENGINE BLEEDS WERE CLOSED FOR HOT TAKEOFF -APU BLEED WAS ON ONLY. #1 ENGINE BLEED PRSOV LOCKED CLOSED IN REFERENCESDR CALA2023062301979Aoa · out of rangePER CREW CAPTAINS SPD LIMIT FLAG AFTER ROTATION, CA AND FO SPEEDS MATCHED ENTIRE FLIGHT SEE IMAGES. FOUND CAPT AOA SENSOR OUT OF RANGE. REPLACED CAPT AOA. OPS TEST GOOD USING ALTERNATE METHOD. REF AMM 34-21-08 AND 34-21-05-730-801. PARTS USED: 29-3412-9-0001,SDR CALA2023062301978Aoa · out of rangePER CREW CAPTAINS SPD LIMIT FLAG AFTER ROTATION, CA AND FO SPEEDS MATCHED ENTIRE FLIGHT SEE IMAGES. FOUND CAPT AOA SENSOR OUT OF RANGE. REPLACED CAPT AOA. OPS TEST GOOD USING ALTERNATE METHOD. REF AMM 34-21-08 AND 34-21-05-730-801. PARTS USED: 29-3412-9-0001,SDR CALA2023062101960Lever · warning lightUNSAFE GEAR INDICATION DURING GEAR EXTENSION FOLLOWED GEAR DISAG REE QRH. ISSUE RESOLVED NO FAULTS ON PSEU BITE, GEAR LEVER FORCE WITHIN LIMITS PER TASK 32-30 TASK 816. CLEANED GEAR LEVER PRECAUTIONARY. CAN NOT DUPLICATE. ADD FAULT:32SDR CALA2023030300622Sensor · noneLE FLAP TRANSIT LIGHT ILLUMINATED OVERHEAD SLAT 1 LIGHT OFF REQUEST MEL 2704K.#1 SLAT INDICATION PROBLEM. LEADING EDGE FLAP INDICATIONS NORMAL, APPLYING MEL 2704K FOR #1 TRUE. WOULD BITE CHECK FSEU TO CONFIRM FULL EXTEND/RETRACT COMPARE RESISTANCE VALUES WITH SDR CALA2022081602064Skin · damagedNO DOCUMENTS FOUND DURING THE AAI RECORD REVIEW AND INSPECTION FOR THE FUSELAGE EXTERNAL REPAIR DOUBLER AT APROX STATION 1060, STR 15R-18R, CUSTOMER REQUEST (UAL QC) (REF AAR NR 99940419) COMPLIED WITH EA NO. 22195, REV P2 AND EC/RA 5331-C2929 (WORK AC COMPLISSDR CALA2022081202058Doubler · noneNO DOCUMENTS FOUND DURING THE AAI RECORD REVIEW AND INSPECTION FOR THE FUSELAGE EXTERNAL REPAIR DOUBLER AT APROX STATION 1060, S TR 15R-18R, CUSTOMER REQUEST (UAL QC) (REF AAR NR 99940419) COMPLIED WITH EA NO. 22195, REV P2 AND EC/RA 5331-C2929 (WORK AC COMPLISDR CALA2022081002014Battery Pack · inoperativeBATTERY PACKS M1673, M1694 AND M1695 INOP (REF. AAR NR 99937908) .SDR CALA2022080501963Pressure Web · crackedCENTER WING FWD L/H SIDE VERTICAL PRESSURE WEB CRACK. (REF AAR RFD NR 99938172). BY AAR RFD TECH V920656 AND AAR QC A-69 V895387. REPAIRED CRACK ON L/H CENTER WING VERTICAL PRESSURE WEB IAW B737 SRM 57-10-10-2R-3 ALT 2 THIS IS A CATAGORY B REPAIR, REINSPECT RESDR CALA2022080301954Spar · crackedREF LPS 3909955, 3910260, AND 3906367, 3 TEMPORARY REPAIRS ON THE WCS REAR SPAR ASSEMBLY VERTICAL PRESSURE WEB REQUIRE REPLACEMENT BETWEEN RBL 27 AND RBL 43. PERMANENT REPAIR IAW SRM 57-10-10-2R-3 ALTERNATIVE 3. THIS IS A LFEC INSPECTION PER TABLE 206 DUE IN 5SDR CALA2019061400938Lamp · inoperativeR2 DOOR EXTERIOR EMERGENCY LIGHT INOP. RE-LAMPED LIGHT REF MM 33-54-01. OPS CK OK.SDR CALA2018102902220Pump · low pressureENG 2 LOW PRESSURE LIGHT LIGHT ON NUMBER 2 ENGINE HYD LOW PRESSURE LIGHT ILLUMINATED IN FLIGHT REMOVED NR 2 ENGINE DRIVEN PUMP IAW AMM29-11-11-000-801-001 UP TO STEP 10 INSTALLED EDP PER AMM 29-11-11-400-801-001 STEPS A1 THRU F7 ACCP EDP INST TEST FROM STEP G,SDR CALA2017081402699Lens · missingSMALL EMERGENCY SIGN AT ROW 21A MISSING. INSTALLED A NEW LENS.SDR CALA2017030500542Lens · brokenROW 28ABC EMERGENCY EXIT PATH LIGHT LENS BROKEN. REPLACED LENS COVERSDR CALA2017030400526Lamp · inoperativeEMERGENCY EXIT LIGHT INOPERATIVE. OVERHEAD BIN BULLNOSE BETWEEN ROWS 3EF AND 4EF. REPLACED THE LAMPS. OPS CHECKED GOOD.SDR CALA2015101900857Heater · unserviceableFLIGHT ATTENDANT REPORTED BURNING RUBBER SMELL & HOT FLOOR IN AFT CABIN. COFFEE POTS WERE HOT. PERFORMED TASK 05-51-26-800-801C1 STEP 1 C D THROUGH H & STEP 2A & B. CHECKED AFT DOOR AREA HEATER OPERATIONS CHECKED IAW TASK 21-45-00700- 802, NO HEAT. FOUND HSDR CALA2015100800833Controller · failedON TAXI OUT PRESSURIZATION AUTO FAIL LIGHT & ALT LIGHT ILLUMINATED, GATE RETURN. TROUBLE SHOT & FOUND CONTROLLER INOPERATIVE. R & R CONTROLLER IAW MM 21-31-01-401. OPERATIONS CHECKED GOOD AT THIS TIME. WIRING CHECKS DONE ON NR 4922229.SDR CALA2015091400757Pump · leakingEXTEND FLAPS ON APPROACH, FLAPS STOPPED AT HALFWAY TO POSITION 1 & WOULD NOT MOVE UP OR DOWN. LE TRANSIT LIGHT ON, ALTERNATE EXTEND TO POSITION 15, NORMAL NO ASYMMETRY ENCOUNTERED. TROUBLE SHOT E FLAPS IAW FIM 27-51-00-810-836, FOUND B HYD EDP LEAKING & QTYSDR CALA2015030900152Battery Pack · dischargedAFT CABIN AFT LT EMER LIGHTS INOPERATIVE. R & R AFT CABIN EMER EXIT LIGHT BATTERY PACK AT STATION 952, PN AD-D717-01-100 IAW AMM 33-51-06. OPERATIONS CHECKED GOOD IAW AMM 33-51-00.SDR CALA2015030900150Light · inoperativeSUPPORT TASK G7 FWD PATH LIGHT INOPERATIVE. R & R FWD PATH LIGHT ASSEMBLY IAW AMM 33-51-0 0. OPERATIONS CHECKED GOOD. PN S479W230-7, STATION 365.55, SN NONE.SDR CALA2015030900149Light · inoperativeSUPPORT TASK G7 AFT PATH LIGHT INOPERATIVE. R & R AFT PATH LIGHT ASSEMBLY IAW AMM 33-51-0 0. OPERATIONS CHECKED GOOD. PN S479W230-7 STATION 365.5 5 SN NONE.SDR CALA2015030900151Battery Pack · dischargedSUPPORT TASK FWD ENTRY EMER LIGHTS INOPERATIVE. R & R FWD ENTRY EMER BATTERY PACK IAW AMM 33-51-00. OPERATIONS CHECKED GOOD.SDR CALA2015030900146Seat Track · damagedDEFECT NOTED WHILE PERFORMING HFEC INSPECTION OF FASTENER HOLE AT STATION 727B, RBL 45.50 OTBD FLANGE AFT HOLE. RECEIVED ECRA 5320-02418 REV ORIGINAL FOR REPAIR OF FASTENER HOLE AT 727B, RBL45.50 OTBD FLANGE AFT HOLE. ALL WORK ACCOMPLISHED IAW ECRA 5320-0241SDR CALA2014092901289Transmitter · failedON FINAL FLAPS STOPPED WORKING 0+1 DEGREE FLAPS. ACCOMPLISHED CHECKLIST. R & R FLAT POSITION TRANSMITTER RT IAW AMM 27-5 8-01-000-801 & 27-58-01-400-801. PERFORMED LAND VERIFY AMM 22-11- 00-700-801. ALL TESTS PASSED. IAW 7729885 FOR AUTO THROTTLES NO AUTOSDR CALA2013102800782Skin · crackedLT HORIZONTAL STAB LOWER SKIN AREA STATION 138.70 & ABOUT 10 INCHES FROM REAR SPAR, CRACK INDICATION NOTED WITH C SCAN. CRACK SIZE IS ABOUT 1/2 INCH LONG IAW EA 5510-01843 REV C OP 1 LT HORIZONTAL STAB LOWER SKIN AT STATION 138.70 HAS BEEN REPAIRED IAW SRM 55SDR CALA2011061400436Skin · crackedPER EA 5510-01843, PERFORMED C-SCAN INSPECTION ON LT HORIZONTAL STAB, FOUND CRACK INDICATION AT STA 129.5 17" AFT OF FRONT SPAR 1.0" LONG. CORRECTED TO READ AIRCRAFT 272 REPAIRED LT LOUVER HORIZONTAL STAB PER ECRA 5510-02181.SDR CALA2011052300379Fan · failedFA'S REPORTED STRONG SMELL OF ELECTRICAL SMOKE ENTIRE AIRCRAFT AND SLIGHT FOG BY DIVIDER. TURNED ON STERIL LIGHT, BUSS TRANSFE R OFF GALLEY SWITCH OFF AND RECIRC FAN OFF. SMOKE AND FUMES DISSIPATED. T/S AS PER AMM 21-00-00-810-806 AND 05-21-26-200-801C2. SDR CALA2010041200135Power Supply · inoperativeFOUND BOTH FWD AND AFT OVERWING HATCH EMERGENCY EXIT LIGHTS ON RIGHT SIDE INOP. REMOVED AND REPLACED POWER SUPPLY FOR RT OVERWING HATCHES EMERGENCY LIGHTS IAW AMM 33-51-06. ALSO REPLACED BATTERY PACK FOR POWER SUPPLY. OPS CHECK GOOD, OK TO CONTINUE.