N362NW
Service difficulty reports · 220
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N362NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N362NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2016040602744Floor Support · corrodedCORROSION ON LOWER SILL BETWEEN FRAME 66 TO FRAME 68 AT LEVEL STR 23L AT AFT GALLEY AREA. REPLACED LOWER SILL LOCATED BETWEEN FRAME 68 AT LEVEL STR 23L AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53480076.SDR DALA2016040602743Floor Support · corrodedCORROSION ON LOWER SILL BETWEEN FRAME 66 TO FRAME 68 AT LEVEL STR 23R AT AFT GALLEY AREA. REPLACED LOWER SILL BETWEEN FRAME 66 TO FRAME 68 AT LEVEL STR 23R AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53480505.SDR DALA2016040602742Profile · crackedCRACK LT LOAD TRANSMITTING PROFILE ON INTERNAL STRUCTURE EMERGENCY EXIT DOOR 834 IN PASSENGER CABIN. REPLACED TRANSMITTING PROFILE ON INTERNAL STRUCTURE EMERGENCY EXIT DOOR 834 IN PASSENGER CABIN IAW SRM 51-72-11 AND DWG D52279036.SDR DALA2016040602741Profile · crackedCRACK RT LOAD TRANSMITTING PROFILE ON INTERNAL STRUCTURE EMERGENCY EXIT DOOR 843 IN PASSENGER CABIN. REPLACED RT LOAD TRANSMITTING PROFILE ON INTERNAL STRUCTURE EMERGENCY EXIT DOOR 843 IN PASSENGER CABIN IAW SRM 51-72-11 AND DWGS, D52279040, D52279010.SDR DALA2016040602740Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y1292 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 24. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53110920.SDR DALA2016112509233Lug · corrodedCORROSION FOUND ON LT ELEVATOR HINGE ARM FITTING5 LUG BORES. REPAIRED IAW ER/A.SDR DALA2016040402630Profile · crackedCRACK LT LOAD TRANSMITTING PROFILE ON INTERNAL STRUCTURE EMERGENCY EXIT DOOR 843 IN PASSENGER CABIN. REPLACED LOAD TRANSMITTING PROFILE ON INTERNAL STRUCTURE EMERGENCY EXIT DOOR 843 IN PASSENGER CABIN IAW SRM 51-72-11 AND DWG D52279040, D52279010.SDR DALA2016033002537Floor Support · corrodedCORROSION ON FLOOR SUPPORT +1225 BETWEEN FRAME 66+5" TO FRAME 67+17" AT AFT GALLEY AREA. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472815.SDR DALA2016033002536Seat Track · corrodedCORROSION ON SEAT TRACK +Y765 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 24. REPLACED SEAT TRACK IAW SRM 51-72-11 AND DWG D53110920.SDR DALA2016033002535Floor Support · corrodedCORROSION ON FLOOR SUPPORT +254 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 24. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53110920.SDR DALA2016032902531Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y1162 BETWEEN FRAME 67+17 TO FRAME 69+4 AT AFT GALLEY AREA. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472780.SDR DALA2016032902530Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y1162 BETWEEN FR 67+17 TO FR 69+4 AT AFT GALLEY AREA. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472780.SDR DALA2016032902529Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y1225 BETWEEN FRAME 66+5 TO FRAME 67+17 AT AFT GALLEY AREA. REPLACED FLOOR SUPPORT -Y1225 BETWEEN FRAME 66+5 TO FRAME 67+17 AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472780.SDR DALA2016032902528Fitting · corrodedCORROSION ON CORNER FITTING FRAME 68 AT AFT GALLEY AREA ON STR 23L MEASURE. REPLACED CORNER FITTING LOCATED FRAME 68 AT AFT GALLEY AREA ON STR 23L IAW SRM 51-72-11 AND DWG D53480505.SDR DALA2016032902527Fitting · corrodedCORROSION ON CORNER FITTING FRAME 66 AT AFT GALLEY AREA AND STRINGER 23L. REPLACED CORNER FITTING FRAME 66 AT AFT GALLEY AREA AND STR 23L IAW SRM A320 51-72-11 AND DWG D53480505.SDR DALA2016032902526Dummy Rail · corrodedCORROSION ON RAIL DUMMY -Y189 AT FWD GALLEY AREA BETWEEN FRAME 20 TO FRAME 24. REPLACED FLOORBEAM RAIL DUMMY -Y189 AT FWD GALLEY AREA BETWEEN FRAME 20 TO FRAME 24 IAW SRM 51-42-11 AND DWG D53111406.SDR DALA2016032902533Floor Support · corrodedCORROSION ON FLOOR SUPPORT -464.8 BETWEEM FRAME 64 TO FRAME 65+10" AT AFT GALLEY AREA. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472816.SDR DALA2016032902532Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y464.8 BETWEEN FRAME 65+10" TO FRAME 70 AT AFT GALLEY AREA. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472800.SDR DALA2016032902525Floor Support · corrodedCORROSION ON FLOORBEAM -Y254 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 24. REPLACED FLOORBEAM STRUCTURE -Y254 FWD GALLEY AREA FRAME 12 TO FRAME 24 IAW SRM 51-72-11 AND DWG NR D53110920.SDR DALA2016032602445Dummy Rail · corrodedCORROSION ON RAIL DUMMY -Y1379.5 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 16. REPLACED RAIL DUMMY -Y1379.5 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 16 IAW SRM 51-72-11 AND DWG D53112831.SDR DALA2016032502326Floor Support · corrodedCORROSION ON FLOOR SUPPORT +254 BETWEEN FRAMES 64 TO 66 IN AFT GALLEY. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472800.SDR DALA2016032502325Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y765 BETWEEN FRAMES 66+5 TO 70 IN AFT GALLEY. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472800.SDR DALA2016032502323Floor Support · corrodedCORROSION ON FLOOR SUPPORT 1500 BETWEEN FRAMES 65 TO 66 IN AFT GALLEY AREA. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND IAW DWG D53474250.SDR DALA2016032502322Stringer · corrodedCORROSION ON WEB FRAME 20 AT FWD GALLEY AREA ON STR 23R. REPLACED WEB LOCATED FRAME 20 AT FWD GALLEY AREA ON STR 23R IAW SRM 51-72-11 AND DWG NR D53112784.SDR DALA2016032502320Fitting · corrodedCORROSION ON CENTER FITTING IN AFT GALLEY AREA ON STRINGER 23R BETWEEN FRAMES 66 TO 68. REPLACED THE FITTING .SDR DALA2016032202314Dummy Rail · corrodedCORROSION ON DUMMY RAIL 503.2 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 16. REPLACED DUMMY RAIL IAW SRM 51-42-11 AND DWG D53112758, D53110984, D53112825.SDR DALA2015122207697Power Supply · malfunctionedOVERWING AISLE AND DOOR EMERGENCY LIGHTS REMAIN ON WHEN EMERGENCY LIGHT SWITCH IN COCKPIT IS IN THE OFF POSITION, RESEATED PIN D AT EPSU.SDR DALA2016012800700Stringer · corrodedCORROSION ON STR 43L BETWEEN FRAMES 56-57, CORROSION OUT OF LIMITS. REPLACED DAMAGED SECTION OF THE STRINGER IAW SRM 53-00-13, FIG 201.SDR DALA2016012800693Stringer · corrodedCORROSION ON STR 42L BETWEEN FRAMES 56-57, CORROSION FOUND TO BE OUT OF LIMITS. REPLACED DAMAGED SECTION OF THE STRINGER IAW SRM 53-00-13, FIG 201.SDR DALA2015052703483Connector · unsecureEMERGENCY LIGHT AT MAIN CABIN SEAT ROWS 3 AND 23 INOPERATIVE. TROUBLESHOT AND FOUND LOOSE CONNECTION, SECURED CONNECTORS AT SEAT ROWS 2 AND 23. TESTS WERE NORMAL.SDR DALA2015010200006Light · damagedF/A REPORTED EMERGENCY LIGHT DAMAGED. REPAIRED THE EMERGENCY LIGHT AND FUNCTIONAL CHECKED NORMAL.SDR DALA1601583262Doubler · corrodedFUSELAGE AFT LAV SERVICE DOOR CUTOUT REINFORCING DOUBLER CORRODED, REPAIRED IAW ER/A 525852-14, LOG 1436046.SDR DALA14033253262Structure · corrodedCORROSION AT FWD LOWER CORNER OF AFT LAVATORY SERVICE PAN, INSIDE AFT CARGO BIN AFT BULKHEAD. REPAIRED IAW ERA 525852-14, REV ORIG COMPLIED WITH PERMANENT REPAIR SECTION II OF AFT LAV SERVICE PAN DOUBLER AND STRINGER 38R IAW ERA 525852-14, REV B. SERVICE CHESDR DALA14014023262Battery Pack · no testDURING NON-ROUTINE CHECK, FOUND AFT LEFT EPSU BATTERY FAILS ON EMERGENCY LIGHT TEST. MAINTENANCE REPLACED BATTERY AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA14003973262Light · inoperativeDURING INSPECTION, FOUND EMERGENCY LIGHT AT SEAT 23ABC INOPERATIVE. MAINTENANCE REPLACED LIGHT ASSY, BR8164-013 AT SEAT AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA13049703262Power Supply · failedCIDS FAILED LEFT EMERGENCY POWER SUPPLY. REPLACED LT EPSU IAW AMM 33-51. CHECKED GOOD.SDR DALA13015623262Battery Pack · inoperativeDURING NON-ROUTINE CHECK, FOUND LT EMERGENCY LIGHT BATTERY FAULT. MX REPLACED LT EMERGENCY LIGHT BATTERY PACK AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA1169743262Wire Harness · disconnectedDURING NON ROUTINE CHECK, FOUND THE EMERGENCY EXIT PATH LIGHT AT SEAT 3B INOPERATIVE. MAINTENANCE RECONNECTED HARNESS AT LIGHT ASSEMBLY AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1164253262Light · looseDURING NON ROUTINE CHECK, FOUND EMERGENCY FLOOR PATH LIGHT AT AFT LEFT LAV INOPERATIVE. MAINTENANCE RE-SECURED LOOSE ASSEMBLY AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1141663262Light · inoperativeDURING A NON ROUTINE CHECK, FOUND THE LEFT EMERGENCY OVERWING EXIT LIGHT INOPERATIVE. MAINTENANCE REPLACED LIGHT ASSEMBLY AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1013593262Door Frame · damagedDURING M-CHECK FOUND RT OVERWING EXIT SURROUND HOLE NR 7 TO BE .3125" DIAMETER. REPAIRED IAW SRM 51-73-12 AND ERA 482883-14AD.SDR DALA1012963262Skin · damagedDURING M-CHECK, FOUND LIGHTNING STRIKE DAMAGE TO FUSELAGE SKIN AT FR47 BUTT JOINT 2 INCHES BELOW S10R. REPAIRED IAW SRM 53-00-11 FIG 216, SRM 53-00-11, SRM 51-42-11.SDR DALA1013173262Shear Web · corrodedDURING M-CHECK, FOUND CORROSION ON SHEAR WEB AT FR28 BETWEEN S42R & S43R. REPAIRED IAW SRM 51-42-11.SDR DALA1013163262Lug · corrodedDURING M-CHECK FOUND CORROSION ON CLEAT AT FR32 S40R-S42R. REPAIRED IAW SRM 51-44-11, SRM 51-42-11.SDR DALA1013153262Shear Web · corrodedDURING M-CHECK FOUND CORROSION ON FR28 SHEAR WEB BETWEEN S41R & S42R. REPAIRED IAW SRM 51-44-11, SRM 51-42-11.SDR DALA1012853262Shear Tie · corrodedDURING M-CHECK FOUND CORROSION ON FRAME CLEAT AT FR33 S40R-S42R. REPAIRED IAW SRM 51-44-11, SRM 51-42-11.SDR DALA1012843262Shear Tie · corrodedDURING M-CHECK FOUND CORROSION ON FRAME CLEAT AT FR31 S40R-S42R. REPAIRED IAW SRM 51-44-11, SRM 51-42-11.SDR DALA1012733262Support Angle · crackedDURING M-CHECK, FOUND CRACK IN SUPPORT ANGLE AT FR42 S42R. REPAIRED IAW SRM 51-42-11.SDR DALA1012693262Floor Support · corrodedDURING M-CHECK FOUND CORROSION ON FLOOR SUPPORT BEAM AT +Y765 FR64-FR66. REPAIRED IAW SRM 51-42-11, SRM 51-44-11.SDR DALA1012313262Sill · corrodedDURING M-CHECK FOUND CORROSION ON AFT RT DOOR MID SHAPE SILL. REPAIRED IAW SRM 51-42-11.
Back to N362NW