What was found
CORROSION ON FLOOR SUPPORT -Y1225 BETWEEN FRAME 66+5 TO FRAME 67+17 AT AFT GALLEY AREA. REPLACED FLOOR SUPPORT -Y1225 BETWEEN FRAME 66+5 TO FRAME 67+17 AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472780.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR SUPPORT -Y1225 BETWEEN FRAME 66+5 TO FRAME 67+17 AT AFT GALLEY AREA. REPLACED FLOOR SUPPORT -Y1225 BETWEEN FRAME 66+5 TO FRAME 67+17 AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472780.