N402UP

Service difficulty reports · 329

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N402UP' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR IPXA1565336Floor Panel · delaminatedINSPECTION TYPE:C3, MCB FLOOR PANEL IS DELAMINATED. REPLACED FLOOR PANEL IAW EO B757-5320-9692G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1565335Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL BS 335-BS 440, RBL 25-RBL 45, WL 208 HAS SEVERAL AREAS OF EDGE DAMAGE. REPLACED FLOOR PANEL BS 335-440, RBL 25-45 IAW SRM 53-00-50-1A1 AND IAW EO B757-5320-9692-G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1565334Floor Panel · delaminatedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS EDGE DAMAGE AND DELAMINATION BS 1100-1200, LBL 45-60, WL 208 (MARKED). REPLACED FLOOR PANEL IAW SRM 53-00-50-1A1 AND EO B757-5320-9692-G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1565333Floor Panel · damagedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL BS 1320-1420 WL 208 HAS 2 MISSING INSERTS. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A1 AND EO B757-5320-9692-G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1565322Floor Panel · damagedINSPECTION TYPE:C3, FLOORBOARD BS 1020 TO BS 1054, RBL 26 TO RBL 45 HAS EDGE DAMAGE, LOOSE INSERTS. FABRICATED FLOORBOARD BS 1020 TO BS 1054, RBL 26 TO RBL 45 IAW EO NR B757-5320-9692-G, SRM 53-00-50-1A.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1565321Floor Panel · damagedINSPECTION TYPE:C3, FLOORBOARD BS 1020 TO BS 1054, RBL 46 TO RBL 61 HAS EDGE DAMAGE, AND LOOSE INSERTS. FABRICATED FLOORBOARD BS 1020 TO BS 1054, RBL 46 TO RBL 61 IAW SRM 53-00-50-1A, EO B757-5320-9692-G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1565320Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD BS 1100 TO BS 1200, RBL 26 TO RBL 45 HAS EDGE DAMAGE. FABRICATED FLOORBOARD BS 1100 TO BS 1200, RBL 26 TO RBL 45 IAW SRM 53-00-50-1A, EO NO B757-5320-9692.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1565319Floor Panel · damagedINSPECTION TYPE:C3, FLOORBOARD BS 1100 TO BS 1200, RBL 46 TO RBL 61 HAS EDGE DAMAGE, AND LOOSE INSERTS. FABRICATED FLOORBOARD BS 1100 TO 1200, RBL 46 TO RBL 61 IAW SRM 53-00-50-1A, EO B757-5320-9692.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1565318Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL BS 1055-1100, LBL 25-45, WL 208 HAS EDGE DAMAGE. FABRICATED FLOOR PANEL BS 1055-1100, LBL 25-45, WL 208 IAW SRM 53-00-50-1A, EO B757-5320-9692.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1565314Shear Web · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY AFT SHEAR WEB UPPER SURFACE IS CORRRODED AT BS 1680, RBL 2.5-16.5, WL 208, BLENDED CORROSION.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA1565313Shear Web · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY AFT SHEAR WEB UPPER SURFACE IS CORRODED AT BS 1681, LBL 40, WL 208, BLENDED CORROSION.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA1565312Shear Web · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY AFT SHEAR WEB UPPER SURFACE IS CORRODED AT BS 1715, LBL .5, WL 208, BLENDED CORROSION.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA1565311Shear Web · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY AFT SHEAR WEB UPPER SURFACE IS CORRODED AT BS 1714.5, RBL .5, WL 208, BLENDED CORROSION.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA1565310Shear Web · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY AFT SHEAR WEB UPPER SURFACE IS CORRODED AT BS 1715, RBL 36, WL 208. BLENDED CORROSION.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA1565309Shear Web · gougedINSPECTION TYPE:C3, MAIN CARGO BAY AFT SHEAR WEB UPPER SURFACE IS GOUGED AT BS 1682-1715 BL 0, WL 208. BLENDED GOUGE.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA1565308Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL 1100-1200, LBL 0-25, WL 208 HAS DAMAGE. FABRICATED NEW FLOOR BOARD.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1565307Floor Panel · crackedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 900-1200, LBL 45-60, WL 208 IS CRACKED. FABRICATED NEW FLOORBOARD.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1565306Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL, BS 1320-1420, RBL 0-25, WL208 IS DAMAGED FABRICATED NEW FLOORBOARD.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1565305Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL, BS 1200-1320, LBL 0-25, WL208 IS DAMAGED FABRICATED NEW FLOORBOARD.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1565304Floor Panel · crackedINSPECTION TYPE:C3, MCB FLOOR PANEL, BS 1540-1600, RBL 45-63, WL208 IS CRACKED. FABRICATED NEW FLOOR BOARDMar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA11565186Floorbeam · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY 1540 FLOORBEAM UPPER AFT FLANGE IS CORRODED AT LBL 37, WL 208. VALIDATED REPAIR IAW SRM 53-60-51-1A, FIG 1 AND 53-00-51-1A, FIG 101. REMOVED CORROSION L1.75" X 2.0"W X .002" D ORIGINAL THK .220", REMAINING THK .218" AT BS 15Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA11565185Floorbeam · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR SEAT TRACK FLANGE HAS CORROSION AT STA 719, LBL 1. VALIDATED REPAIR IAW SRM 53-00-51-1A-1. REMOVED CORROSION 15" W X 1.5"L ORIGINAL THK .220", REMOVED .022" REMAINING THK .198" AT BS 720, RBL 27 TO RBL 42 IAW 51-10-02Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA11565184Seat Track · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR SEAT TRACK FLANGE HAS CORROSION AT STA 719, LBL 1. VALIDATED REPAIR IAW SRM 53-00-52-1A-1, FIG 101 AND 53-30-52-01. REMOVED CORROSION 1" X 1.73" X .067" ORIGINAL THK .070+.02-.00", REMOVED .023" REMAINING THK .067" AMar 6, 2011 · N402UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA11565183Floorbeam · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY BS 1681 FLOORBEAM NUT PLATE STRAP IS CORRODED RBL 52, WL 207 ON FWD UPPER FLANGE LOWER SIDE. AFTER INVESTIGATION NO ALLOWABLE DAMAGE AVAILABLE IN SRM FOR NUT PLATE STRAP. REMOVED NUT PLATE STRAP AT BS 1681, RBL 52, WL 207 IMar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA11565182Floorbeam · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY BS 1540 FLOORBEAM UPPER AFT FLANGE IS CORRODED RBL 36.5 AND 40 WL 208. VALIDATED REPAIR IAW SRM 53-60-51-1A, FIG 1 AND 53-00-51-1A, FIG 101. REMOVED CORROSION L2.5" X 1.5" WX.002D ORIGINAL THICKNESS .220". REMAINING THICKNEMar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA1565827Support Bracket · damagedINSPECTION TYPE:C3, RT WING T/E - INBD MAIN FLAP - LOWER SURFACE - JUST INBD OF OTBD FLAP TRACK - FAIRING SUPPORT BRACKET HAS FRETTING DAMAGE. R & R BRACKET IAW ATS ER 11-01898.Mar 5, 2011 · N402UP · Boeing 75724APF · Trailing Edge FlapsSDR IPXA11566031Panel · gougedINSPECTION TYPE:C3, PANEL NR 666BR IS GOUGED ON INTERNAL SIDE (MARKED). REPAIRED IAW ATS ER 11-01823 DATED 4-8-11, EO B757-5750-42137, A DATED 4-11-11, DWG 113N3500, SRM 51-30-01, SRM 51-40-08.Mar 4, 2011 · N402UP · Boeing 75724APF · Trailing Edge FlapsSDR IPXA1565839Door Frame · damagedINSPECTION TYPE:C3, MAIN CARGO DOOR, MECHANICAL DAMAGE ON FRAME BS 529, WL 217, AND 222. REPAIRED FRAME IAW ER NR 11-01807 AND UPS EO B757-5230-42080-A.Mar 4, 2011 · N402UP · Boeing 75724APF · Fuselage Main, StructureSDR IPXA11565479Web · gougedINSPECTION TYPE:C3, VERTICAL WEB IS DENTED AND GOUGED IN THE MAIN E BAY 4.5" ABOVE THE DOOR LATCH PLATE AT BS 468, RBL 8, WL 157. REMOVED DAMAGED PART & FABRICATED REPLACEMENT & INSTALLED IAW SRM 51-40-2 & DWG NR 284N1038, REV BF.Mar 4, 2011 · N402UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11565476Door Frame · damagedINSPECTION TYPE:C3, MAIN CARGO DOOR, MECHANICAL DAMAGE ON FRAME BS 484, WL 217 AND 222. FABRICATED FRAME DOUBLER AND INSTALLED IAW SRM 52-30-02-1A, SRM 51-40-02-0G, DWG 65-25327, SRM 51-20-01-0G.Mar 4, 2011 · N402UP · Boeing 75724APF · Cargo/Baggage DoorsSDR IPXA1565339Bracket · crackedINSPECTION TYPE:C3, APU FIRE BOTTLE MOUNT BRACKET IS CRACKED. R & R BRACKET IAW SRM 51-40-02.Mar 4, 2011 · N402UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562279Gauge · malfunctionedAPPROX 30 MIN INTO FLIGHT, CREW NOTICED AN EXCEEDENCE OF 650 ON THE R EGT GAUGE. UNKOWN OF WHEN IT OCCURRED OR FOR HOW LONG. ENGINE OPERATES NORMALLY. NO OTHER ABNORMALITIES NOTED. IAW MM 72-00-00-6 AND MM 71-00-00-5, ALL REQUIRED CHECKS PERFORMED ON RT ENG Aug 25, 2010 · N402UP · Boeing 75724APF · Engine EGT/TIT Indicating SystemSDR IPXA10561556Floor Panel · damagedINSPECTION TYPE:C2, FLOOR PANEL IS DAMAGED ON INBD EDGE, BS 728, RBL 25, WL208. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.Jul 30, 2010 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561555Floor Panel · damagedINSPECTION TYPE:C2, FLOOR PANEL OTBD EDGE IS DAMAGED, B.S 777 LBL 45, WL 208 FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.Jul 30, 2010 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10561554Floor Panel · damagedINSPECTION TYPE:C2, FLOOR PANEL INBD LOWER EDGE IS DAMAGED, B/S 620 B/S 720, LBL 25, WL208. FABRICATED REPLACEMENT FLOOR PANEL IAW UPS EO B757-5320-9692.Jul 30, 2010 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560679Web · corrodedINSPECTION TYPE:SP, WHILE WORKING CARD 877002, FOUND CORROSION AT PREVIOUS BLEND ON SHEAR WEB AT BS 326, LBL 38, WL 208, LOWER SURFACE REPAIRED IAW EO B757-5310-38324-A.Jun 18, 2010 · N402UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560570Hinge · elongatedINSPECTION TYPE:SP, WHILE WORKING CUSTOMER ID 874010, FOUND MAIN CARGO DOOR FWD HINGE (DOOR SIDE), TO HAVE AN ELONGATED HOLE AT THE FWD LWR HOLE LOCATION. REPAIRED IAW ER NR 10-3018, DATED 16JUN2010.Jun 8, 2010 · N402UP · Boeing 75724APF · Fuselage, Door HingeSDR IPXA10560569Structure · damagedINSPECTION TYPE:SP, MAIN CARGO DOOR STRUCTURE, HAS AN OUT OF ROUND HOLE LOCATED 1ST HOLE AFT UPPER ROW AT NR 1 FWD HINGE SEGMENT. ATS ER NR 10-3018, DATED 16JUN2010.Jun 4, 2010 · N402UP · Boeing 75724APF · Cargo/Baggage DoorsSDR IPXA10560568Structure · damagedINSPECTION TYPE:SP, MAIN CARGO DOOR STRUCTURE HAS AN OUT OF ROUND HOLE LOCATED AT NR 8 HOLE UPPER ROW UNDER NR 10 HINGE SEGMENT. REPAIRED IAW ER NR 10-3018, DATED 16JUN2010.Jun 4, 2010 · N402UP · Boeing 75724APF · Cargo/Baggage DoorsSDR IPXA10560567Structure · damagedINSPECTION TYPE:SP, MAIN CARGO DOOR STRUCTURE HAS AN OUT OF ROUND HOLE LOCATED NR 9 HOLE UPPER ROW UNDER NR10 HINGE. REPAIRED IAW ER NR 10-3018, DATED 06-16-10.Jun 4, 2010 · N402UP · Boeing 75724APF · Cargo/Baggage DoorsSDR IPXA10560566Hinge · corrodedINSP TYPE:SP MAIN CARGO DOOR NR 7 HINGE SEGMENT LOWER HINGE ON DOOR SIDE 2ND HOLE ON TOP IS CORRODED. REPAIRED IAW ER NR 10-3018 DATED 16-JUN-2010.Jun 4, 2010 · N402UP · Boeing 75724APF · Fuselage, Door HingeSDR IPXA10560565Structure · damagedINSPECTION TYPE:SP, MAIN CARGO DOOR STRUCTURE, HAS AN OUT OF ROUND HOLE WITH FALSE POSITIVE INDICATION, LOCATED 3RD HOLE AFT UPPER ROLL AT NR 1 FWD HINGE SEGMENT. REPAIRED IAW ER 10-3018, DATED 16JUN2010.Jun 3, 2010 · N402UP · Boeing 75724APF · Cargo/Baggage DoorsSDR IPXA09555588Panel · damagedINSPECTION TYPE:C2 LOWER FUSELAGE AFT KEEL BEAM PANEL SUPPORT HAS 4 ELONGATED HOLES AT STA 1140 REPLACED KEEL BEAM PANEL SUPPORT (BAFFLE) IAW SRM 51-40-05-0G, SRM 51-40-06-0G.Apr 12, 2009 · N402UP · Boeing 75724APF · Fuselage Main, Plate/SkinSDR IPXA09555687Skin · misrepairedINSPECTION TYPE:C2 FOUND A FORWARD CARGO DOOR SKIN REPAIR THAT APPEARS TO MEET ALL THE REQUIREMENTS OF THE SRM 52-30-01-01-2R EXCEPT THE DOUBLER THICKNESS IS 0.080 INCH. REMOVED THE CURRENT REPAIR DOUBLER THAT DOES NOT MEET THE REQUIREMENTS OF THE SRM REPAIR Apr 10, 2009 · N402UP · Boeing 75724APF · Cargo/Baggage DoorsSDR IPXA09555686Carriage · chafedINSPECTION TYPE:C2 OUTBOARD MAIN FLAP NR 1 FLAP CARRIAGE FWD PANEL 666BR IS CHAFED ON INNER SURFACE. REMOVED CHAFING DAMAGE AND COMPLIED WITH ALL STEPS IN ER 09-2305 DATED 4-21-09 AND SRM 57-53-01-1-A1.Apr 10, 2009 · N402UP · Boeing 75724APF · Trailing Edge FlapsSDR IPXA09555685Floor Support · chafedINSPECTION TYPE:C2 FWD CARGO COMPARTMENT A/C MIX BAY FLOOR SUPPORT AT BS 845 LBL 17 WL 200 IS CHAFED. REMOVED SUPPORT, FABRICATED REPLACEMENT AND INSTALLED PER SRM 51-40-2.Apr 8, 2009 · N402UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA09555684Floor Support · chafedINSPECTION TYPE:C2 FWD CARGO COMPARTMENT A/C MIX BAY FLOOR SUPPORT AT BS 845 RBL 17 WL 200 IS CHAFED. REMOVED SUPPORT, FABRICATED AND INSTALLED REPLACEMENT SUPPORT PER SRM 51-40-02.Apr 8, 2009 · N402UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA09555595Skin · tornINSPECTION TYPE:C2 RT WING FIXED LE UPPER SURFACE IS TORN BETWEEN NR 7 AND NR 8 LE SLATS. REPAIRED RT WING FIXED LE UPPER SURFACE BETWEEN NR 7 AND NR 8 SLATS IAW STANDARD REPAIR MANUAL EO B757-5740-11855-D.Apr 8, 2009 · N402UP · Boeing 75724APF · Wing, Plate/SkinSDR IPXA09555594Wedge · dentedINSPECTION TYPE:C2 R/W OTBD AFT FLAP UPPER T/E WEDGE HAS A DENT 28 INCH OTBD OF INBD END (SRM 57-53-01-01 REFERS TO TREAT AS A HOLE OR PUNCTURE) AFT FLAP WAS REPAIRED PER SRM51-70-04.Apr 8, 2009 · N402UP · Boeing 75724APF · Trailing Edge FlapsSDR IPXA09555593Plate · crackedINSPECTION TYPE:C2 CRACKED WIGGLE PLATE STA 330.0 R/W. REPLACED PER B757-5750-5622-A.Apr 8, 2009 · N402UP · Boeing 75724APF · Wing Miscellaneous Structure
Back to N402UP