N406UA
Service difficulty reports · 151
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N406UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N406UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010080202808Oxygen Gen · misinstalledO2 GENERATORS AT SEAT LOCATIONS 17DEF, 21DEF AND 20ABC FOUND WITH SHIPPING PINS INSTALLED. ALSO FWD ATT O2 GENERATOR FOUND WITH HOSE DISCONNECTED. R & R O2 GENERATORS CORRECTLY. THE FWD ATT MASK REPLACED ON NR C5767R.SDR UALA2010080202774Skin · corrodedCORROSION AT FWD PIT FR 26-27 STRINGER 42R-41R ON SKIN. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SKIN AND INSTALLED DOUBLER REPAIR.SDR UALA2010052101729Sliding Window · delaminatedFO-S SLIDING WINDOW HAS DELAMINATION AT BOTTOM EDGE. VISIBILITY IS NOT IMPAIRED. DELAMINATION MEASURED AT APPROX 5.25 X 3.25. EXCEEDS LIMIT IAW MM. ACCOMPLISHED F/O SLIDING WINDOW REPLACEMENT.SDR UALA2010033001068Diaphragm · damagedDOOR 1R ACCUMULATOR PRESSURE IS LOW. REPLACED DIAPHRAGM IN THE PERCUSSION MECHANISM. SERVICED BOTTLE TO PREVAILING LIMITS.SDR UALA2010032200949Panel · crackedRT WING NEAR ROOT SMALL PANEL BELOW SLAT IS DAMAGED, CRACKED. PANEL IS 621BB, OUT OF LIMITS FOR SRM. CRACK IS APPROX 6 INCHES, ACROSS ENTIRE PANEL. REPLACED DAMAGED PANEL AND INSPECTED AREA WITH NO DAMAGE FOUND.SDR UALA2010010400031Girt Bar · out of adjustUNABLE TO ARM DOOR 1R. CREW REPORTS: WHEN DOOR 1R IS ARMED, SLIDE MESSAGE ON ECAM DOOR PAGE DISPLAYS, THEN GOES AWAY. ADJUSTED GIRT BAR AND GIRT CURTAIN, REINSTALLED SLIDE.SDR UALA2010010400036Girt Bar · out of adjustUNABLE TO ARM DOOR 1R. WHEN DOOR 1R IS ARMED, SLIDE MESSAGE ON ECAM DOOR PAGE DISPLAYS, THEN GOES AWAY. ADJUSTED GIRT BAR AND GIRT CURTAIN, REINSTALLED SLIDE.SDR UALA2009121703906Fire Detector · faultyNR 1 ENG HAS HAD 3 OCCURENCES OF FIRE WARNING POST CK ON FLIGHT. INDICATION COMES AND GOES. ALL PARAMETERS NORMAL INCLUDING FUEL FLOW. SAMC TEXT: CREW REPORTS MALFUNCTION IS IN LOOP 'A'. REF TSM 26-12-00-810-803, NR1 FDU TESTS OK. RESISTANCE VALUES OF DET'S SDR UALA2009121403841Skin · dentedFOUND DENT ON FUSELAGE LT SIDE JUST AFT OF RADOME APPROX 4 O'CLOCK POSITION. MAJOR REPAIR ACCOMPLISHED: DENT FALLS WITHIN 'OUT OF NEARNESS' CRITERION, DUE TO PROXIMITY TO A FASTENER. DENT IS .5 INCH IN DIAMETER, WITH A DEPTH OF.023. DENT IS LOCATED 5 INS AFTSDR UALA2009102203295Power Supply · dischargedLEFT FWD EPSU BATTERY FAILING PTP TEST. REPLACED EPSU AND BATTERY AT DOOR 1 LEFT.SDR UALA2009090802820Slide · damagedLEFT OVERWING SLIDE PACK DAMAGED BEYOND LIMITS. REPLACED SLIDE.SDR UALA2009042101156Skin · corrodedFOUND CORROSION IN THE BELLY SKIN BELOW THE FWD-PIT DOOR. DETERIORATION COMPLETELY THRU SKIN. SKIN REPAIR IS COMPLETE, CLOSING UP. SEALED & PAINTED.SDR UALA2008123007051Skin · dentedDOOR 2L HAS DENT 16.0" AFT OF FWD EDGE AND 13.5" FROM BOTTOM. EVALUATED DENT & FOUND OUT OF LIMITS. CUT OUT DAMAGE. FABRICATED & INSTALLED EXTERNAL DOUBLER REPAIR. RESTORED THE PROTECTIVE COATING.SDR UALA2008122406992Sill · corrodedL2 DOOR SILL HAS CORROSION AT AFT GIRT FITTING. MAJOR REPAIR. INSTALLED ANGLE REPAIR.SDR UALA2008122406991Support · corrodedR2 DOOR SILL HAS CORROSION AT AFT GIRT SUPPORT BLOCK. MAJOR REPAIR. INSTALLED REPAIR ANGLE.SDR 2008UALA05539Power Supply · faultyEMERGENCY LIGHT SYS TEST FAULTS "UNIT EMER R". *S/D* REPLACED POWER SUPPLY, OP CHECKS OKAY.SDR 2008UALA01476Battery · failedDURING EMERGENCY LIGHT TEST R BATTERY FAULTED. BATTERY FAILURE. REPLACED R EMER LIGHT BATTERY. OPS CHECKED NORMALLY.SDR 2008UALA00696Actuator · weakOXYGEN MASK 6ABC FELL OUT. WEAK ACTUATOR. REPLACED DOOR ACTUATOR AND TESTED O2 SYSTEM, SYSTEM OPS CHECKS NORMAL AND DOOR REMAINS IN PLACE.SDR 2007UALA05274Battery · failedEMERGENCY LIGHT TEST FAILS LEFT FORWARD DOOR BATTERY. BATTERY FAULTY. REPLACED DOOR LIGHT BATTERY AT DOOR 1L.SDR 2007UALA04412Fluid · dischargedWHILE TAXIING LOST NOSE WHEEL STEERING, FOLLOWED BY HYD GREEN RSVR LOW LVL STATUS MESSAGE. ALL GREEN SYSTEM FLUID DUMPED ONTO RAMP FROM AIRCRAFT WHEEL WELL AREA. FOUND DAMAGED GREEN SYS HYD LINE IN AFT PIT UNDER FLOOR, RING LOCK PULLED APART. REPAIRED GREESDR 2007UALA04206Battery · faultyRIGHT SIDE MID CABIN EMERGENCY LIGHT BATTERY DISPLAYED FAULT. 10-26-07 FOUND FAULTY EMERGENCY LIGHT BATTERY. REPLACED EMERGENCY LIGHT BATTERYSDR 2007UALA03804Hydraulic System · leakingEVIDENCE OF HYD LEAK AFT FUSELAGE GREEN SYSTEM. LOST 1 US GAL IN 1.5 HRS.SDR 2007UALA02635Oxygen Mask · unwanted deployOXYGEN MASKS DEPLOYED 7DEF ON LANDING. BROKEN O2 LATCH AT ROW 7DEF. REPLACED O2 CONTAINER ASSY.SDR 2007UALA01245A/C Pack · overheatedCREW REPORTED BAD ODOR IN THE CABIN. NR 2 PACK OVERHEATED SO IT WAS SHUT DOWN, THUS DESCENDING TO FL300. CONTINUED TO DESTINATION. REPLACED NR 2 RAM AIR OUTLET ACT. OPS CHECKS GOOD. AND ALSO PACK CONTROLLER AS PRECAUTION. NO REPEATS SINCE 10/13.SDR 2007UALA01209Line · malfunctionedCREW REPORTS LOSS OF GREEN HYDRAULICS SYSTEM. ALTERNATE GEAR EXTENTION USED FOR LANDING. [06-22-07] FOUND A CRACK UNDERNEATH A CLAMP AREA ON THE HYDRAULIC LINE TO THE MAIN LANDING GEAR UPLOCK. REPLACED HYDRAULIC LINE AND REPLACED EDP AND CASE FILTER AS A SDR 2007UALA01163Power Supply · faultyEMERGENCY LIGHT TEST FAILED ON 3SVC CK. FAULTS INT LOADS EMERG L, EXT LOADS EMERG L, AND COMM EMERG L IN VIEW. SUPPLEMENTAL DATA UPDATE REPLACED POWER SUPPLY AND BATTERY. OP CHECKS GOOD.SDR 2007UALA00702Pump · failedGREEN HYDRAULIC PUMP FAILURE JUST AFTER DEPARTURE. REPLACED NR 1 ENGINE PUMP PRESSURE SWITCH. RAN ENGINE PRESSURE AND INDICATION NORMAL.SDR 2006UALA02296Slide · unserviceablePASSENGER DOOR 2L ESCAPE SLIDE RAFT RELEASE STRAP NOT ROUTED THROUGH GIRT BAR. RELEASE STRAP AND SURVIVAL KIT LANYARD NOT VELCROED TO EACH OTHER. REPLACED 2L SLIDE-RAFT.SDR 2006UALA02295Slide · unserviceablePASSENGER DOOR 2R ESCAPE SLIDE RAFT RELEASE STRAP NOT ROUTED THROUGH GIRT BAR. RELEASE STRAP AND SURVIVAL KIT LANYARD NOT VELCROED TO EACH OTHER, MOORING LINE LOOSE IN GIRT AND NOT ATTACHED TO GIRT BAR, ELECTRICAL HARNESS LOOSE (NOT SECURED UNDER VELCRO) AND SDR 2006UALA02294Slide · unserviceablePASSENGER DOOR 1L ESCAPE SLIDE RAFT RELEASE STRAP NOT ROUTED THROUGH GIRT BAR. RELEASE STRAP AND SURVIVAL KIT LANYARD NOT VELCROED TOGETHER, PARACHUTE PIN NOT SECURED WITH NYLON THREAD (IT IS SECURED WITH A LACING CORD WHICH LOOKS LIKE IT WILL NOT BREAK EASILSDR 2006UALA02131Landing Gear · malfunctionedFLIGHT DIVERTED DUE TO LANDING GEAR PROBLEMS. GEAR WAS MANUALLY EXTENDED. REPLACED LANDING GEAR CONTROL INTERFACE UNIT NR 1 AND 2. OPS CHECKED GOOD. ALSO REPLACED NORMAL LANDING GEAR CONTROL LEVER. ALL CHECKS NORMAL.SDR 2006UALA01719Bulb · inoperativeEMERGENCY ESCAPE PATH LIGHT INOP ON LAV-D DOOR 2L. RELAMPED BULBS, LIGHT OPS GOOD.SDR 2006UALA01703Unknown · unknownCREW REPORTS ALTERNATE LAW DISPLAYED WITH NO FLIGHT CONTROL FAULTS. REPLACED NR 2 ELAC AND ACCOMPLISHED TEST, TEST NORMAL.SDR 2006UALA01468Battery · faultyFOUND 1L EMERGENCY LIGHT BATTERY FAULT. REPLACED BATTERY, SYSTEM TESTS OK.SDR 2006UALA00785Lanyard · damagedFOUND LANYARD IS DAMAGED AT L2 DOOR SLIDE. REPLACED SLIDE/RAFT ASSY.SDR 2006UALA00627Compressor · stalledNR 1 ENG HAD A COMPRESSOR STALL DURING CLIMB AT APPROX 3000 FT AGL WITH A UPPER ECAM WARNING. UNDETERMINED CAUSE, TROUBLESHOOTING CHECKS RETURNED NO DEFECTS.SDR 2006UALA00426Blower · seizedBLOWER FAULT DISPLAYED ON UPPER ECAM SCREEN. BLOWER FAULT DISPLAYED ON UPPER ECAM SCREEN. MAINTENANCE CHECKED AND FOUND BLOWER FAN 20HQ SEIZED AND CIRCUIT BREAKER AD10 TRIPPED. REPLACED AEVC BLOWER FAN 20HQ (MR21211, 644-0089) PER MM 21-26-51. SYSTEM OP-CHSDR 2005UALA01203Aspirator · unserviceableTWO (2) DAMAGED ASPIRATORS.SDR 2005UALA00482Electrical Sys · unknownFLIGHT ATTENDANT SHOCKED WHILE HOLDING THE G1 AND G2 GALLEY COUNTER TOPS, DURING POWER TRANSFER FROM GROUND TO APU. INSPECTION AND VERIFICATION OF THE ELECTRICAL GROUNDING OF BOTH HOT GALLEY AND COLD GALLEY SECTIONS WERE ACCOMPLISHED IN ACCORDANCE WITH THE ASDR 2003UALA00954Structure · damagedLEFT ELEVATOR MR55501-006 HAD 2 AREAS OF WATER INGRESS FOUND DURING ACP OF COA 40535. ONE ON THE UPPER SURFACE 2.3 BY 1.4 INCH, 154 INCHES FROM THE I/B EDGE, AND 3.5 INCHES FROM THE T/E. ONE ON THE LWR SURFACE 2.9 BY 1.9 INCH, 139 INCHES FROM THE I/B EDGE ANSDR 2003UALA00953Structure · damagedRT ELEVATOR MR55500-006 HAD 4 AREAS OF WATER INGRESS FOUND DURING ACP OF COA 40535. UPPER SURFACE HAD AN AREA 2.6 BY 1.3 INCH LOCATED 160.5 INCHES FROM I/B EDGE, AND 3.5 INCHES FROM T/E LWR SURFACE HAD 3 AREAS, ONE 4.0 BY 1.5 INCH FROM 113 INCHES FROM I/B EDGSDR 2001UALA02437Bellows · blownCABIN ALTITUDE COULD NOT BE MAINTAINED BELOW 10,000 IN AUTO. PACK NR 2 WAS DEFERRED INOPERATIVE, PACK NR 1 WOULD NOT PRESSURIZE THE CABIN, FOUND BLOWN COOLING DUCT BELLOWS NR 1 PACK, REPLACED AND OPERATIONALLY CHECKED NORMAL. PACK NR 2 WAS LATER OPERATIONALLSDR 2001UALA01394Thermostat · failedNR 1 ENGINE BLEED FAULT DISPLAYED ON UPPER ECAM SCREEN. *S/D* REPLACED CONTROL THERMOSTAT AS FAULTED IN CENTRALIZED FAULT DISPLAY SYSTEM. IN ADDITION, THE HEAT EXCHANGER OUTLET TEMPERATURE SENSOR AND BLEED MANAGEMENT COMPUTER WERE REPLACED PRECAUTIONARY. SDR 2000UALA00697Coffeemaker · shortedELECTRICAL SMELL COMING FROM AFT GALLEY OVEN AREA. *S/D* COFFEEMAKER M42, P/N 11225-1 HAD AN INTERNAL ELECTRICAL FAILURE (WIRING MELTED) WHICH CAUSED AN ELECTRICAL SMELL IN THE AFT GALLEY. THIS COFFEEMAKER WAS REMOVED AND REPLACED. NO REPEAT A/C WRITE-UPS.SDR 2000UALA00266Tube · will not testAFT DOOR SLIDE/RAFT LOWER TUBE FAILED PROOF PRESSURE TEST. *S/D* FOUND THE LOWER TUBE TO HAVE A SEAM FAILURE AT THE TOP END CROSSOVER TUBE. SENT UNIT TO VENDOR FOR REPAIR.SDR 99UAL900147Pump · leakingINTERMITTENT GREEN HYD SYSTEM LOW ECAM WARNING. PRESSURE NORMAL AND NO FLUCTUATION. FOUND NR 1 ENGINE DRIVEN HYDRAULIC PUMP LEAKING. REPLACED PUMP PER MM29-11-51. LEAK AND OPS CHECKS GOOD.SDR 99ZZZX419Pan · crackedDURING THE FIRST HEAVY MAINTENANCE VISIT (HMU-1) VIRTUALLY 100 PERCENT OF THE COACH SEATS IN THE PASSENGER CABIN WERE FOUND TO HAVE SEAT PANS THAT WERE CRACKED AT THE FORWARD ATTACHMENT HOLES FOR THE SEAT PANS. THESE ARE RECARO 720 SERIES SEATS INSTALLED IN ASDR 97UAL900750Window · crackedUPON ARRIVAL, FOUND LOWER ECAM WARNING RELATED TO THE NR 3 CAPTAINS FIXED WINDOW 7DG1. INSPECTED AND FOUND THE NR 3 WINDOW CRACKED 7DG1 NP165313-1 OUT OF LIMITS REF AIRBUS MM 56-11-12-200-001. REPLACED NR 3 CAPTAINS FIXED WINDOW REF MM TASK 56-11-12-400-002.SDR 96UAL900368Battery Pack · dischargedAFT LEFT EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK.SDR 96UAL900162Power Supply · inoperativeEMERGENCY LIGHT TEST FAILED. REPLACED FWD EMERGENCY POWER SUPPLY UNIT.
Back to N406UA