N412UP
Service difficulty reports · 248
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N412UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N412UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA201407023480Floor Panel · crushedINSPECTION TYPE:CP16, FLOOR PANEL 241XBF CORNER IS CRUSHED. FABRICATED NEW FLOOR PANEL IAW SREO B757-53 20-9692-H.SDR IPXA201407023479Floor Panel · damagedINSPECTION TYPE:CP16, FLOOR PANEL 241XDF HAS CORE DAMAGE. FABRICATED NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2014070783501Transition Panel · corrodedINSPECTION CP16, AFT LOWER CARGO BAY BS 1440, RBL 22, TRANSITION PANEL CORRODED. REMOVED CORROSION IAW SRM 51-10-02-06. R & R RT TRANSITION PANEL IAW SRM 51-40-02-0G.SDR IPXA2013123001167Skin · dentedFUSELAGE SKIN DAMAGED AT BS 560, STR 20L. REPAIRED IAW EO B757-5330-53009-A.SDR IPXA2574673Duct · disconnectedAT FL250 CABIN ALTITUDE EICAS MESSAGE CAME ON, CABIN PRESSURE WAS 10200 CABIN ALTITUDE LIGHT EXTINGUISHED AT AROUND FL200 EMERGENCY DECLARED. FOUND RT CABIN AIR SUPPLY CHECK VALVE DUCT NOT CONNECTED, RED DUCT, ADJUSTED AND RECONNECTED DUCT. PERFORMED SINGLE SDR IPXA2574627Frame · dentedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT, BS 520, FRAME IS DENTED, AND GOUGED BETWEEN STR 16R AND 17R. REPAIR FRAME IAW EA 120866, AND EO B757-5310-48019-A.SDR IPXA2574587Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 232XDF IS DAMAGED. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574586Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 231XJF IS DAMAGED. FABRICATE FLOOR PANEL IAW EO B757-5230-9692-H.SDR IPXA2574585Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 232XNF DAMAGED AT BOTH EDGES. FABRICATED MAIN CARGO FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574570Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 251XFF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574569Seat Track · damagedINSPECTION TYPE: C, SEAT TRACK BS 694 LBL 0, TOP OF TRACK GOUGED. COMPLETED SEAT TRACK REPAIR IAW SRM 53-00-52-2R7.SDR IPXA12574514Floor Panel · mismanufacturedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 252XFF MISMANUFACTURED. FABRICATED FLOOR PANEL IAW EO B757-5320- 9692-HSDR IPXA2574485Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOORBOARD 231XVF DELAMINATED EDGE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574605Seat Track · corrodedINSPECTION TYPE: C, SEAT TRACK BS 1681 BL 0 HAS CORROSION. REPAIRED SEAT TRACK IAW EA 120911 AND EO B757-5310-48028-A.SDR IPXA2574475Floorboard · delaminatedINSPECTION TYPE:C, MAIN CARGO COMPARTMENT FLOORBOARD 231XFF DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574428Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 252XLF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574427Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 232XEF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574426Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 232XFF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574408Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 251XNF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574391Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 251XCF DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574390Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 232XDF DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574389Floorboard · damagedINSPECTION TYPE:C, MAIN CARGO FLOORBOARD 251XFF DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574387Floor Panel · damagedINSPECTION TYPE:C, FLOOR PANEL 231XHF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574385Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 231XGF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574364Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 242XKF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574348Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 251XPF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574339Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 231XMF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574544Floor Panel · damagedINSPECTION TYPE:C, FLOOR PANEL 252XTF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574473Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOORBOARD 231XEF INSERT BROKEN & DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574386Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 252XQF DAMAGED. FABRICATED NEW FLOOR PANEL 252XQF IAW EO B757-5320-9692-H.SDR IPXA2574380Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 252XFF HAS EDGE DAMAGE IN CORNER. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574379Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 252XHF DELAMINATED IN CORNER. FABRICATED FLOORBOARD IAW EO B757-5320-9692- H.SDR IPXA2574378Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 251XEF HAS TWO INSERTS DAMAGED. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574377Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 232XRF HAS DAMAGED INSERTS. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574376Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 252XEF HAS DELAMINATION IN CORNER. FABRICATION FLOORBOARD IAW EO B757-5320-9692.SDR IPXA2574375Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO BAY, FLOORBOARD 232XGF HAS TWO INSERTS BROKEN. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574367Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 251XJF DAMAGED. FABRICATED NEW FLOOR PANEL AW EO B757-5320-9692-H.SDR IPXA2574366Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 251XAF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574365Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 252XJF DAMAGED. FABRICAED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574351Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 251XLF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574350Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 252XKF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574349Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 252XPF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574347Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 251XGF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574333Floor Panel · damagedINSPECTION TYPE:C, FLOOR PANEL 251XKF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574332Floor Panel · damagedINSPECTION TYPE:C, FLOOR PANEL 251XBF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574331Floor Panel · damagedINSPECTION TYPE:C, FLOOR PANEL 252XNF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574629Floor Panel · gougedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 251XRF HAS SEVERAL GOUGES, DAMAGE TO THE TOP AND BOTTOM SIDE OF PANEL, AND CORRODED FASTENER INSERTS. FABRICATED MAIN CARGO FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574529Floor Support · corrodedINSPECTION TYPE:C, COCKPIT UPPER LEVEL FLOOR STRUCTURE INTERCOSTAL CORRODED, STA 297 -310.5, LBL 60. REMOVED CORROSION ORIGINAL THICKNESS .050 LOSS .007 WITH .043 REMAINING IS OUT OF LIMITS IAW SRM 53-10-15-1A-1. FABRICATED NEW INTERCOSTAL IAW GMM 09-10 AND SDR IPXA2574477Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOORBOARD 252XUF DELAMINATED FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574476Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOORBOARD 251XQF DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.
Back to N412UP