N418UP
Service difficulty reports · 239
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N418UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N418UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA09555202Floor Panel · puncturedINSPECTION TYPE:C3 FLOOR PANEL BS 1100-1200 LBL 24-45 WL 208 IS PUNCTURED. PANEL WAS REPLACED PER EO B757-5320-9692F.SDR IPXA09555507Floorbeam · corrodedINSPECTION TYPE:C3 FLOORBEAM AT BS 1200, LBL 33 CORRODED. REPAIRED PER ATS ER 09-0279-A.SDR IPXA09555470Shear Web · corrodedINSPECTION TYPE:C3 CORROSION ON SHEAR WEB IN SEVERAL AREAS BS 389-BS 414 RBL 48 WL 208. REMOVED CORROSION, NDT, REPLACED FASTENERS, ALODINE, PRIMED, CPC IAW EO B757-5310-33056-A.SDR IPXA09555468Strap · corrodedINSPECTION TYPE:C3 APU CUTOUT AFT STRAP P/N 148N3138-8000 IS CORRODED BS 1824 STR 3R-6R. REPAIRED PER ATS ER 09-2077 DATED 08APR09.SDR IPXA09555404Shear Web · corrodedINSPECTION TYPE:C3 CORROSION ON SHEAR WEB UNDER MOP SILL AT SEVERAL AREAS BS 1701 LBL 13 AND LBL 33 WL 208. REMOVED CORROSION, NDT, ALODINE & PRIMED IAW EO B757-5310-33021-A.SDR IPXA09555403Shear Web · corrodedINSPECTION TYPE:C3 CORROSION ON SHEAR WEB UNDER MOP SILL AT SEVERAL AREAS BS 1711. REMOVED CORROSION, NDT, ALODINED & PRIMED IAW EO B757-5310-33021-A.SDR IPXA09555402Shear Web · corrodedINSPECTION TYPE:C3 CORROSION ON SHEAR WEB UNDER MOP SILL AT SEVERAL AREAS BS 1695 RBL14 WL 208. REMOVED CORROSION, INSP, NDT, ALODINE & PRIMED IAW EO B757-5310-33021- A.SDR IPXA09555315Floorbeam · corrodedINSPECTION TYPE:C3 FLOORBEAM AT BS 1320, LBL 33 IS CORRODED BEYOND LIMITS. REMOVED CORROSION FROM TOP OF FLOORBEAM AT BS 1320 LBL 33 AND REPAIRED AS PER EO B757-5310-32963-A.SDR IPXA09555314Bracket · damagedINSPECTION TYPE:C3 RT WING LOWER T/E PANEL TRUNNION FAIRING HAS 2 FASTENERS LOOSE ON THE I/B EDGE. REMOVED, FABRICATED AND INSTALLED REPLACEMENT BRACKET PER SRM 51-40-02.SDR IPXA09555312Floor Panel · damagedINSPECTION TYPE:C3 FLOOR PANEL JUST INSIDE ENTRY DOOR HAS SEVERAL FASTENERS INSERTS DAMAGED AND PULLED THROUGH, ALSO SEVERAL INSERTS CORRODED ON LOWER SURFACE. PANEL WAS REPLACED IAW SRM 53-00-50-2R1.SDR IPXA09555206Floor Panel · damagedINSPECTION TYPE:C3 FLOOR PANEL BS 1040 RBL 35 WL 208 PUNCTURED LOWER SURFACE AND DELAMINATED CORNER. PANEL WAS REPLACED IAW EO B757-5320-9692-F.SDR IPXA09555205Floor Panel · delaminatedINSPECTION TYPE:C3 FLOOR PANEL BS 1020 LBL 30 WL 208 HAS CORE DAMAGE AND DELAMINATION AT FWD CORNER. PANEL WAS REPLACED IAW B757-5320-9692F.SDR IPXA09555526Shear Web · corrodedINSPECTION TYPE:C3 CORROSION ON FLOOR WEB BETWEEN FRAME 324 TO 333.45 LBL 25 TO LBL 45 WL 208. REMOVED CORROSION, NDT, ALODINE AND PRIMED PER EO B757-5310-33062A.SDR IPXA09555525Floorbeam · corrodedINSPECTION TYPE:C3 FLOORBEAM SUPPORT AT STA 560 LBL 16 AREA OF CORROSION. REMOVED CORROSION, FABRICATED DOUBLER ANGLE, ALODINE, PRIMED AND INSTALLED IAW EO B757-5330-33011A.SDR IPXA09555524Frame · gougedINSPECTION TYPE:C3 BS 365 FRAME HAS ONE GOUGE AT STR 15L. DRILLED OUT DAMAGE ON FRAME TO .193 INCH DIAMETER HOLE AND INSTALLED RIVET.SDR IPXA09555484Shear Web · corrodedINSPECTION TYPE:C3 CORROSION ON FLOOR WEB BETWEEN FRAME 324 TO 333.45 LBL 25 TO LBL 45 WL 208. REMOVED CORROSION, NDT, ALODINE AND PRIMED PER EO B757-5310-33062-A.SDR IPXA09555466Doubler · chafedINSPECTION TYPE:C3 REPAIR SEQUENCE 418-F1-05 REPAIR DOUBLER IS CHAFED AND GROOVED BS 1859-1871 STR 14R. REPAIRED PER ATS ER 09-2080 DATED 08APR09.SDR IPXA09555448Crease Beam · corrodedINSPECTION TYPE:C3 CREASE BEAM INNER CHORD CORRODED AT STA 655 LBL 64. REMOVED CORROSION, NDT, ALODINE & PRIMED IAW EO B757-5310-33042A.SDR IPXA09555447Support · corrodedINSPECTION TYPE:C3 FLOORBEAM SUPPORT AT STA 560 LBL 16 AREA OF CORROSION. REMOVED CORROSION, FABRICATED DOUBLER ANGLE, ALODINE, PRIMED & INSTALLED IAW EO B757-5330-33011A.SDR IPXA09555446Support · corrodedINSPECTION TYPE:C3 FLOORBEAM SUPPORT AT STA 560 LBL 37 AREA OF CORROSION. REMOVED CORROSION, FILLED AREA, ALODINED & PRIMED IAW EO B757-5330-330 11A.SDR IPXA09555445Frame · damagedINSPECTION TYPE:C3 BS 395 FRAME STR 12-13L HAS 2 AREAS WITH SCREW DAMAGE. REPAIRED PER ATS ER 09-2074 DATED 06APR09.SDR IPXA09555401Floor Support · corrodedINSPECTION TYPE:C3 CORROSION ON FLOORBOARD SUPPORT LBL 65 FROM STA 324 TO 297 WL 208. REMOVED & REPLACED FLOORBOARD SUPPORT IAW SRM 51-40-02.SDR IPXA09555400Support · corrodedINSPECTION TYPE:C3 FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT CORRODED BS 766-845 RT SIDE. BLENDED OUT CORROSION PER ATS ER 09-2165 DATED 02APR09.SDR IPXA09555360Support · corrodedINSPECTION TYPE:C3 FLOORBEAM SUPPORT AT STA 620 LBL 35 AREA OF CORROSION. SUPPORT WAS REPAIRED PER ATS ENGINEERING REPAIR 09-2083.SDR IPXA09555311Seat Track · corrodedINSPECTION TYPE:C3 CORROSION ON SEAT TRACK O/B FLANGE UPPER AND LOWER SURFACES BS 1602 - BS 1610 LBL 46 WL 208. SEAT TRACK SECTION WAS REPLACED IAW SRM 51-40-02.SDR IPXA09555310Seat Track · corrodedINSPECTION TYPE:C3 CORROSION ON SEAT TRACK I/B FLANGE BS 1167 - BS 1198 LBL 45 WL 208. CORROSION REMOVAL BLENDED OUT OF LIMITS. REMOVED AND REPLACED SEAT TRACK IAW SRM 51-40-02-0G, 51-40-08-0G, DWG 146N5218-1.SDR IPXA09555309Seat Track · corrodedINSPECTION TYPE:C3 CORROSION ON SEAT TRACK O/B FLANGE BS 1182 LBL 26 WL 208. FOUND 100 PERCENT MATERIAL LOSS. REMOVED AND REPLACED SEAT TRACK BS 1180-1320 IAW SRM 51-40-02-0G, DWG 146N5218-1, SRM 51-40-08-0G.SDR IPXA09555307Floorbeam · corrodedINSPECTION TYPE:C3 CORROSION ON FLOORBEAM BS 1600 LBL 48 - LBL 57 WL 208. FLOORBEAM WAS REPAIRED PER ATS ENGINEERING 09-2088 DATED 3-30-09.SDR IPXA09555306Floor Panel · debondedINSPECTION TYPE:C3 FLOOR PANEL BETWEEN 480 TO 560 AND LBL 45.5 TO 62 FWD I/B CORNER IS DISBONDED AND I/B EDGE IS DISBONDED. PANEL WAS REPLACED IAW SRM 53-00-50-2R1.SDR IPXA09555305Support · corrodedINSPECTION TYPE:C3 FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT CORRODED BS 646-766 RT SIDE. REMOVED AND REPLACED SUPPORT PER SRM 51-40-02.SDR IPXA09555304Floorbeam · gougedINSPECTION TYPE:C3 FWD CARGO BAY FLOORBEAM GOUGED AT BS 577.5 RBL 15 WL 156.5. REMOVED AND REPLACED FLOOR SUPPORT AT BS 577.5 RBL 15 WL 156.5.SDR IPXA09555261Sill · gougedINSPECTION TYPE:C3 FCB DOOR CUTOUT SILL IS GOUGED BS 563 RBL 20 WL 156. REMOVED AND REPLACED SILL PER SRM 51-40-02.SDR IPXA09555211Angle · crackedINSPECTION TYPE:C3 L-ANGLE IS CRACKED AT BS 1064 W/L 145 LBL 59 COMMON TO LANDING GEAR DOOR SENSOR. REMOVED AND REPLACED CRACKED ANGLE IAW SRM 51-40-02-06 AND SRM 51-40-05-06.SDR IPXA09555210Floor Panel · damagedINSPECTION TYPE:C3 FLOOR PANEL BETWEEN STA 560 TO 620, RBL 0 TO 24.5, I/B SIDE FASTENER HOLE BLOWN OUT. PANEL WAS REPLACED PER EO B757-5320-9692.SDR IPXA09555209Floor Panel · damagedINSPECTION TYPE:C3 FLOOR PANEL BETWEEN STA 480 TO 560, RBL 45.5 TO 62, FWD END FASTENER HOLE BLOWN OUT. PANEL WAS REPLACED IAW EO B757-5320-9692F.SDR IPXA09555208Floor Panel · damagedINSPECTION TYPE:C3 FLOOR PANEL BETWEEN STA 480 TO 560, RBL 24.5 TO 45.5, O/B SIDE FASTENER HOLE BLOWN OUT. PANEL WAS REPLACED PER EO B757-5320-9692.SDR IPXA09555207Floor Panel · brokenINSPECTION TYPE:C3 FLOOR PANEL BROKEN BS 1300 RBL 46-RBL 60.5 WL 208. PANEL WAS REPLACED IAW EO B757-5320-9692 F.SDR IPXA09555204Floor Panel · debondedINSPECTION TYPE:C3 FLOOR PANEL BETWEEN 620 TO 720 AND LBL 45.5 TO 62 I/B EDGE IS DISBONDED. REPAIRED PER EO B757-5320-9692-F.SDR IPXA09555444Frame · gougedINSPECTION TYPE:C3 BS 395 STR 16L-7L FRAME HAS NINE SCREW GOUGES. REPAIRED PER ATS ER 09-2074 DATED 06APR09.SDR IPXA09555303Floor Support · corrodedINSPECTION TYPE:C3 CORROSION ON FLOOR SUPPORT AT BS 1055 RBL 0-25 WL 208. FLOOR SUPPORT WAS REPLACED IAW SRM 51-40-02-0G.SDR IPXA09555302Floor Support · corrodedINSPECTION TYPE:C3 CORROSION ON FLOOR SUPPORT AT BS 1055, BL 0 LBL 25 WL 208. FLOOR SUPPORT WAS REPLACED IAW SRM 51-40-02-0G.SDR IPXA09555246Frame · damagedINSPECTION TYPE:C3 FRAME DAMAGED ON I/B FLANGE BS 1300 LBL 69 WL 222.5. REPAIRED PER B757-5310-19952-C.SDR IPXA09555245Frame · damagedINSPECTION TYPE:C3 FRAME DAMAGED ON I/B FLANGE BS 1260 LBL 69 WL 222.5. REPAIRED PER B757-5310-19952-C.SDR IPXA09555244Frame · damagedINSPECTION TYPE:C3 FRAME DAMAGE ON I/B FLANGE BS 1220 LBL 69 WL 222.5. REPAIRED PER B757-5310-19952-C.SDR IPXA09555242Frame · damagedINSPECTION TYPE:C3 FRAME DAMAGED ON I/B FLANGE BS 1220 RBL 69 WL 222.5. REPAIRED PER B757-5310-19952-C.SDR IPXA09555241Frame · damagedINSPECTION TYPE:C3 FRAME DAMAGED ON I/B FLANGE BS 1260 RBL 69 WL 222.5. REPAIRED PER B757-5310-19952-C.SDR IPXA09555239Frame · damagedINSPECTION TYPE:C3 FRAME DAMAGED ON I/B FLANGE BS 1300 RBL 69 WL 222.5. REPAIRED PER B757-5310-19952-C.SDR IPXA09555238Frame · damagedINSPECTION TYPE:C3 FRAME DAMAGED ON I/B FLANGE BS 1340 RBL 69 WL 222.5. REPAIRED PER B757-5310-19952-C.SDR IPXA09555237Frame · damagedINSPECTION TYPE:C3 FRAME DAMAGED ON I/B FLANGE BS 1460 RBL 69 WL 222.5. REPAIRED PER B757-5310-19952-C.SDR IPXA09555236Frame · damagedINSPECTION TYPE:C3 FRAME DAMAGED ON I/B FLANGE BS 1500 RBL 69 WL 222.5. REPAIRED PER B757-5310-19952-C.
Back to N418UP