N421UP
Service difficulty reports · 311
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N421UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N421UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA10561216Floorboard · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL AT BS 1680-1720 RT SIDE HAS SEVERAL CORRODED INSERTS. FABRICATED NEW FLOOR PANELS IAW EO NR B757-5320-9692.SDR IPXA10561215Floorboard · delaminatedINSPECTION TYPE:C3, MAIN FLOOR PANEL AT BS 1680 - 1720 LT SIDE IS DELAMINATED ON INBD AND OTBD AFT CORNERS. FABRICATED NEW FLOOR PANEL IAW EO NR B757-5320-9692SDR IPXA10561065Panel · dentedINSPECTION TYPE:C2, LT FLOOR TO SIDEWALL SUPPORT PANEL IS DENTED BS 660, LBL 22.5, WL 154. R & R PANEL IAW SRM 51-40-02.SDR IPXA10560954Floor Panel · dentedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL AT BS 1420-1540, BL0 - LBL 25 HAS SEVERAL DENTS & GOUGES ON LWR SURFACE. REPLACED IAW EO B757-5320-9692-G, B757-5100-33281-A.SDR IPXA10560932Floor Panel · puncturedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL AT B/S 1600 THRU 1680 RBL 25 THRU RBL 45 HAS SEVERAL INSERTS THAT ARE CORRODED AND PULLING THROUGH. SEVERAL PUNCTURES ON LOWER SURFACE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10560930Floor Panel · dentedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL AT BS 1420 THRU 1540, BL 0 THRU RBL 25 HAS SEVERAL DENTS AND GOUGES ON LOWER SURFACE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO NR B757-5320-9692-G.SDR IPXA10560912Floor Panel · puncturedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL AT BS 1540 THRU 1600 LBL 25 THRU LBL 45 IS PUNCTURED ON LOWER SURFACE. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10560911Floor Panel · damagedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL AT BS 1320 THRU 1420 LBL 25 THRU LBL 45 HAS AN INSERT PULLING THROUGH AND SEVERAL DENTS AND GOUGES ON LOWER SURFACE. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10560910Floor Panel · damagedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL AT BS 1200 THRU 1320 LBL 45 THRU LBL 61 HAS EDGE DAMAGE AT INBD AFT CORNER. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10560899Floor Panel · damagedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL AT BS 1100 THRU 1200 BL 0 THRU LBL 25 HAS EDGE DAMAGE AT AFT OTBD CORNER. FABRICATED REPLACEMENT PANEL IAW B757-5320-9692-G.SDR IPXA10560898Floor Panel · damagedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL AT BS 1200 THRU 1320 BL 0 THRU LBL 25 HAS AN INSERT PULLING THROUGH. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10560897Floor Panel · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL AT BS 1540 THRU 1600 RBL 45 THRU RBL 61. HAS INSERTS THAT ARE CORRODED AND PULLING THROUGH. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10560896Floor Panel · dentedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL AT BS 1540 THRU 1600 RBL 25 THRU 45. HAS DENTS AND PUNCTURES ON INBD SIDE LOWER SURFACE. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10560895Floor Panel · gougedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL AT BS 1320 THRU 1420, LBL 45 THRU 61. HAS SEVERAL GOUGES AND DENTS ON LOWER SURFACE INBD EDGE, AND (1) ON UPPER SURFACE AFT EDGE. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10560894Floor Panel · damagedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL AT BS 1600 THRU 1680 BL 0 THRU 25. HAS SEVERAL INSERTS THAT ARE CORRODED AND PULLING THROUGH. AND PUNCTURES ON LOWER SURFACE. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10560893Floor Panel · gougedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL AT BS 1020 THRU 1060, BL 0 THRU LBL 25. IS GOUGED ON LOWER SURFACE. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10560892Floor Panel · gougedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL AT BS 1540 THRU 1600 BL 0 THRU LBL 25 IS GOUGED ON OTBD EDGE. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10560891Floor Panel · debondedINSPECTION TYPE:C3, 43 SECTION, FLOORBOARD AT STA 440 TO STA 480 LBL 45 TO LBL 61 INBD EDGE AND AFT CORNER DISBONDED. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10561283Seat Track · corrodedINSPECTION TYPE:C3, DUE TO MULTIPLE AREAS OF OUT OF LIMITS CORROSION SEAT TRACK FROM BS 440 TO 680, LBL 25 REQUIRES REPLACEMENT. REPAIR IAW SRM 53-00-52, REPAIR 5.SDR IPXA10561214Seat Track · corrodedINSPECTION TYPE:C3, DUE TO MULTIPLE AREAS OF OUT OF LIMITS CORROSION SEAT TRACK FROM BS 440-680 AT LBL 25 REQUIRES REPLACEMENT. REMOVED DAMAGED SEAT TRACK, FABRICATE REPLACEMENT SEAT TRACK & INSTALLED REPLACEMENT.SDR IPXA10561191Cover · crackedINSPECTION TYPE:C3, AFT ACTUATOR COVER IS CRACKED. REMOVED DAMAGE IAW ER 10-3410.SDR IPXA10561422Floorboard · debondedINSPECTION TYPE:C3, 43 SECTION, FLOORBOARD AT STA 620 TO720 LBL 45 TO LBL 61, INBD EDGE DEBONDED AND MISSING INSERT, AND BOARD BROKEN IN CTR. FABRICATED NEW FLOORBOARD IAW RO B757-5320-9692-G.SDR IPXA10561270Shear Web · corrodedINSPECTION TYPE:C3, 43 SECTION, CORROSION ON MULTIPLE AREAS (MARKED) ON SHEAR WEB AT STA 480 TO STA 560, LBL 45 TO LBL 61. BLENDED AND REFINISHED CORRODED AREAS IAW ATS ER 10-3343.SDR IPXA10561269Seat Track · corrodedINSPECTION TYPE:C3, 43 SECTION, CORROSION ON SEAT TRACK AT STA 615 BL 0 OTBD FLANGE. REPAIRED IAW ATS ER 10-3305, EO B757-5310-38871-A.SDR IPXA10561219Floorbeam · corrodedINSPECTION TYPE:C3, 43 SECTION CORROSION ON FLOORBEAM AT STA 620 LBL 0 TO LBL 45 UPPER FLANGE. REPAIRED IAW EO B757-5310-38819-A.SDR IPXA10561205Floorboard · debondedINSPECTION TYPE:C3, 43 SECTION FLOORBOARD AT STA 480 TO STA 560, LBL 45 TO LBL 61 INBD EDGE DISBONDED AND 2 INSERTS MISSING FROM FWD EDGE. MADE REPLACEMENT FLOOR PANEL USING OLD PANEL AS A TEMPLATE USING MATERIAL A402H LOT NR 921330 IAW EO NR B757-5320-9692.SDR IPXA10561126Floorbeam · corrodedINSPECTION TYPE:C3, 43 SECTION, CORROSION ON FLOORBEAM AT STA 440, RBL 20 UPPER AFT FLANGE. BLENDED AND REFINISHED IAW ATS ER 10-3290.SDR IPXA10561123Floorbeam · corrodedINSPECTION TYPE:C3, 43 SECTION, CORROSION ON FLOORBEAM AT STA 440, RBL 20 UPPER AFT FLANGE. REPAIRED IAW ER NR10-3290 DATED 12-JUL-10 AND EO B757-5310-38755, DATED 7/15/10.SDR IPXA10561041Floorboard · debondedINSPECTION TYPE:C3, 43 SECTION, FLOORBOARD AT STA 480 TO 560, RBL 25 TO RBL 45 INSERTS MISSING ALONG INBD & OTBD EDGE AND FWD INBD CORNER DISBONDED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO NR B757-5320-9692-G.SDR IPXA10560990Floorbeam · tornINSPECTION TYPE:C3, 43 SECTION, SUPPORT CHORD TORN AT STA484, RBL10. R & R UPPER SUPPORT CHORD BETWEEN BS480 TO 500 RBL10.SDR IPXA10560942Floor Panel · corrodedINSPECTION TYPE:C3, FWD CARGO NR 2 FLOOR PANEL HAS CORROSION ON UPPER SURFACE IN PANEL AREA. FABRICATED REPLACEMENT NR 2 FLOOR PANEL IAW SRM 51-40-05-OG, SRM 51-40-08-OG, SRM 51-20-01-OG.SDR IPXA10560941Floor Panel · corrodedINSPECTION TYPE:C3, FWD CARGO NR 4 FLOOR PANEL HAS CORROSION ON UPPER SURFACE. IN PANEL AREA. FABRICATED REPLACEMENT NR 4 FLOOR PANEL IAW SRM 51-40-02-OG, SRM 51-40-08-OG, SRM 51-20-01-OG.SDR IPXA10560940Floor Panel · corrodedINSPECTION TYPE:C3, FWD CARGO NR 2 FLOOR PANEL HAS CORROSION ON UPPER SURFACE IN PANEL AREA. FABRICATED REPLACEMENT NR2 FLOOR PANEL IAW SRM 51-40-08-OG, AND SRM 51-20-01-OG.SDR IPXA10560939Floor Panel · corrodedINSPECTION TYPE:C3, FWD CARGO NR 4 FLOOR PANEL HAS CORROSION ON UPPER SURFACE. IN PANEL AREA. FABRICATED REPLACEMENT NR 4 FLOOR PANEL IAW SRM 51-40-02-OG, SRM 51-40-08-OG, SRM 51-20-01-OG.SDR IPXA10560938Floor Panel · corrodedINSPECTION TYPE:C3, FWD CARGO NR 4 FLOOR PANEL HAS CORROSION ON UPPER SURFACE. IN PANEL AREA. FABRICATED REPLACEMENT NR 4 FLOOR PANEL IAW SRM 51-40-02-OG, SRM 51-40-08-OG, SRM 51-20-01-OG.SDR IPXA10560837Floor Panel · gougedINSPECTION TYPE:C3, 43 SECTION, FLOORBOARD AT STA 560-STA 620, RBL 25-RBL 45, INBD LOWER EDGE IS GOUGED IN 2 PLACES. PANEL FABRICATED IAW EO B757-5320-9692-G.SDR IPXA10560836Floor Panel · debondedINSPECTION TYPE:C3, 43 SECTION, FLOORBOARD AT STA 480-STA 560 LBL 0-LBL 25 INBD EDGE DEBONDED & MISSING INSERTS. PANEL REPLACED IAW EO B757-5320-9692-G.SDR IPXA10560835Floor Panel · debondedINSPECTION TYPE:C3, 43 SECTION, FLOORBOARD AT STA 440-STA 480 LBL 45-LBL 61 INBD EDGE AND AFT CORNER DEBONDED. FABRICATED REPLACEMENT PANEL IAW B757-5320-9692-G.SDR IPXA10560829Floor Panel · gougedINSPECTION TYPE:C3, 43 SECTION, FLOORBOARD AT STA 480-560 RBL45 TO RBL61 INBD EDGE MISSING INSERTS AND HAS MULTIPLE GOUGES ON INBD LOWER SURFACE FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5350-9692-G.SDR IPXA10560828Floor Panel · debondedINSPECTION TYPE:C3, 43 SECTION, FLOORBOARD AT STA 560-STA 620, LBL 25-LBL 45 OTBD AFT EDGE DEBONDED. FABRICATED REPLACEMENT FLOOR PANEL IAW B757-5320-9692-G.SDR IPXA10560827Floor Panel · debondedINSPECTION TYPE:C3, 43 SECTION, FLOORBOARD AT STA 560-STA620 LBL61 INBD EDGE DEBONDED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10560825Floorboard · corrodedINSPECTION TYPE:C3, WHILE WORKING CARD NR 867293 FOUND SEVERAL FLOORBOARD INSERTS TO BE CORRODED, PANEL LOCATION BS 339-440, LBL 25.5 THRU 44 LBL. COMPLIED WITH EO NR B757-5320-9692-G DUE TO DAMAGE FOUND OUT OF LIMITS.SDR IPXA10560816Seat Track · corrodedINSPECTION TYPE:C3, WHILE WORKING CUSTOMER CARD NR 867379, FOUND CORROSION AT SEAT TRACK LBL 25 OTBD FLANGE NUT PLATE LOCATIONS EXTENDED TO INCLUDE BS 606-619, WL 208. REPLACED SEAT TRACK ON CUST CARD NR 867481.SDR IPXA10560815Seat Track · corrodedINSPECTION TYPE:C3, 43 SECTION, CORROSION ON SEAT TRACK AT STA 580 TO STA 604 LBL 25 OTBD FLANGE. REPLACED SEAT TRACK ON CUST CARD NR 867481.SDR IPXA10560814Seat Track · corrodedINSPECTION TYPE:C3 43 SECTION, CORROSION ON SEAT TRACK AT STA 440 LBL 25 OTBD FLANGE. REPLACED SEAT TRACK ON CUST CARD NR867481.SDR IPXA10561345Beam · corrodedINSPECTION TYPE:C3, 44 SECTION, CORRODED NUTPLATES ON LONGITUDINAL BEAM FROM STA 1020 TO 1040 LBL 45 OTBD FLANGE. BLENDED AND RE-FINISHED IAW ATS ER 10-3298.SDR IPXA10561315Frame · dentedINSPECTION TYPE:C3, DENT ON BS 840 FRAME BETWEEN STR 24L & STR 25L, LBL 38 IN FWD CARGO BAY. INSTALLED REPAIR DOUBLER ON FRAME IAW SRM 53-00-07-2R-5 AND INSTALLED STRUCTURAL SHIM COMMON TO DOUBLER AND SHEAR TIE IAW EO B757-5310-38868-A.SDR IPXA10561293Floorbeam · corrodedINSPECTION TYPE:C3, 44 SECTION , CORRODED NUT PLATES ON FLOORBEAM AT STA 1100 LBL 0 TO LBL 25. REPAIRED IAW EO B757-5310-38903-A.SDR IPXA10561285Floor Support · corrodedINSPECTION TYPE:C3, 44 SECTION, CORRODED NUT PLATES ON LONGITUDINAL BEAM AT STA 900 TO 920, RBL 45 OTBD FLANGE. REPAIRED IAW EO B757-5310-38872-A.SDR IPXA10561284Frame · dentedINSPECTION TYPE:C3, FWD CARGO COMPARTMENT BS 820, STR 24L, LBL 39 FRAME DENTED. REPAIRED IAW ATS ER 10-3279 FOR MINOR SHIM DEVIATION TO SRM REPAIR. AND B757-5310-38877-A.
Back to N421UP