N422UP
Service difficulty reports · 271
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N422UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N422UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA11568136Structure · dentedNR 2 SLAT DENTED 112" FROM OTBD END, 4.375" FROM T/E. REPAIRED IAW EO B757-5750-43597-A AND SRM 51-70-10.SDR IPXA11566765Skin · dentedLT OTBD MAIN FLAP UPPER SKIN DENTED ON PANEL. REPAIRED REF EO B757-5750-42266-D.SDR IPXA11566532Floor Panel · damagedMCD FWD FLOOR PANEL DAMAGED. FABRICATED FLOOR PANEL REF EO B757-5320-9692-G AND EO B757-5320-42596-A.SDR IPXA11566531Floor Panel · damagedMCD FLOOR PANEL DAMAGED. FABRICATED FLOOR PANEL REF EO B757-5320-9692-G AND EO B757-5320-42596A.SDR IPXA11566530Floor Panel · damagedMCD FLOOR PANEL 141N5410-19 DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-38342 AND B757-5320-9692.SDR IPXA11566529Floor Panel · damagedMCD FLOOR PANEL DAMAGED 141N5410-16. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-38342 AND B757-5320-9692.SDR IPXA11566528Floor Panel · damagedMCD FLOOR PANEL 141N5410-29 DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-38342 AND B757-5320-9692.SDR IPXA11566527Floor Panel · damagedMCD FLOOR PANEL 141N5410-20 DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-38342 AND B757-5320-9692.SDR IPXA11566526Floor Panel · delaminatedMCD FLOOR PANEL 141N5410-30 DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-38342 AND B757-5320-9692.SDR IPXA11566525Floor Panel · damagedMCD FLOOR PANEL 141N5410-15 DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-38342 AND EO B757-5320-9692.SDR IPXA11566519Floor Panel · damagedFLOOR PANEL AT POS 2 RT DAMAGED. FABRICATE NEW FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA11566518Floor Panel · damagedFLOOR PANEL AT POS 2 LT DAMAGED. FABRICATE NEW FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA11566517Floor Panel · damagedFLOOR PANEL AT POS 2 RT DAMAGED. FABRICATE NEW FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA11566516Floor Panel · damagedFLOOR PANEL AT POS 2 DAMAGED. FABRICATE NEW FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA10560747Skin · chafedINSPECTION TYPE:C3, GENERATED FOR RCD PURPOSES ONLY FOR REPLACEMENT OF PANEL PN 148N7308-2. ALL WORK ACCOMPLISHED ON CUSTOMER CARD NR 864609.SDR IPXA10560746Skin · chafedINSPECTION TYPE:C3, GENERATED FOR RCD PURPOSES ONLY FOR REPLACEMENT OF PANEL PN 148N7308-6. ALL WORK ACCOMPLISHED ON CUSTOMER CARD NR 864609.SDR IPXA10560702Skin · chafedINSPECTION TYPE:C3, WHILE INSPECTING FOR ADDITIONAL DAMAGE ON CARD 864609 FOUND BRACKET CHAFING IN INTERNAL SKIN BS 1800 10 INCHES ABOVE STR 17R. REPAIRED IAW ATS ER 10-3181.SDR IPXA10560701Skin · chafedINSPECTION TYPE:C3, WHILE INSPECTING FOR ADDITIONAL DAMAGE ON CARD 864610, FOUND BRACKET CHAFING ON INTERNAL SKIN, BS 1800, 10 INCHES ABOVE STR 17L. REPAIRED IAW ATS ER NR 10-3176.SDR IPXA10560556Floorbeam · corrodedINSPECTION TYPE:C3, MLB FLOORBEAM HAS EXFOLIATION CORROSION ON UPPER FLANGE, BS 879, LBL 20, WL 208. REPAIRED FLOORBEAM IAW ER 10-2912.SDR IPXA10560554Floorbeam · corrodedINSPECTION TYPE:C3 MLB FLOORBEAM HAS EXFOLIATION CORROSION ON UPPER FLANGE, BS 879, LBL 20, WL 208. REPAIRED FLOORBEAM IAW ER 10-2912.SDR IPXA0560627Skin · dentedINSPECTION TYPE:C3, FOUND DENT ON EXTERIOR SKIN AT BS 247, S26R INSTALLED REPAIR DOUBLER IAW SRM53-00-01-2R.SDR IPXA10560739Skin · chafedINSPECTION TYPE:C3, SKIN CHAFED ABOVE RT HORIZ STAB, COMMON TO STAB SEAL FROM BS 1829 TO 1872. REPAIRED IAW ATS ER10-3044.SDR IPXA10560738Skin · chafedINSPECTION TYPE:C3, SKIN CHAFED BELOW LT HORIZ STAB, COMMON TO STAB SEAL FROM BS 1798 TO 1870. REPAIRED IAW ATS ER10-3050.SDR IPXA10560737Skin · chafedINSPECTION TYPE:C3, SKIN CHAFED BELOW RT HORIZ STAB, COMMON TO STAB SEAL FROM BS 1798 TO 1870. REPAIRED IAW ATS ER10-3044.SDR IPXA0560633Skin · dentedINSPECTION TYPE:C3, WHILE WORKING CUSTOMER CARD NR 864594, STR REPAIR, CAUSED DENT IN SKIN AT BS 1682, STR 15R. REPAIRED SKIN IAW ER NR10-3026.SDR IPXA10560700Frame · damagedINSPECTION TYPE:C3, MAIN CARGO BAY FRAME INNER FLANGE HAS SCREW START AT BS 1580, STR 14L. REPAIRED IAW ATS ER NR 10-2996.SDR IPXA0560632Stringer · crackedINSPECTION TYPE:C3 CRACKED UPPER WEB OF STRINGER 15R AT BS 1681. REPAIRED STRINGER IAW ER NR 10-3026.SDR IPXA10560549Tension Tie · mismanufacturedINSPECTION TYPE:C3, 9G RIGID BARRIER CTR SECTION TENSION STRAP HAS DOUBLE HOLES, STR 1-2 LT. REPAIR IAW ATS ER NR 10-2902.SDR IPXA10560548Tension Tie · damagedINSPECTION TYPE:C3, 9G RIGID BARRIER CTR SECTION TENSION STRAP HAS DOUBLE HOLES, STR 1-2 RT. REPAIR IAW ATS ER 10-2902.SDR IPXA10560547Tension Tie · damagedINSPECTION TYPE:C3, 9G RIGID BARRIER CTR SECTION TENSION STRAP HAS DOUBLE HOLES, STR 2-3 LT. REPAIR IAW ATS ER NR 10-2902.SDR IPXA10560733Frame · gougedINSPECTION TYPE:C3, GOUGE IN FRAME AT BS 1620 AT STR 13-14 LT IS IN THE RADIUS AND CAN NOT BE CLEANED UP IAW THE SRM. REPAIRED IAW ATS ER 10-2946.SDR IPXA10560140Floor Panel · corrodedINSPECTION TYPE:C3, FWD CARGO BAY NR 3 FLOOR PANEL IS CORRODED ON THE UPPER SURFACE. REMOVED, FABRICATED, AND INSTALLED NR FLOOR PANEL IAW SRM 51-10-07-0G, SRM 53-00-53-1A, SRM 51-40-02-0G.SDR IPXA10560550Tension Tie · damagedINSPECTION TYPE:C3, 9G RIGID BARRIER CTR SECTION TENSION STRAP HAS DOUBLE HOLES, STR 2-3 RT. REPAIR IAW ATS ER 10-2902.SDR IPXA10560456Rib · corrodedINSPECTION TYPE:C3, T/E RIB AT LT WS 817.27 CORRODED AROUND AILERON BONDING STRAP ATTACH POINT. REPAIRED IAW ATS ER NR 10-2957.SDR IPXA10560603Seat Track · corrodedINSPECTION TYPE:C3 CORROSION ON INBD FLANGE OF SEAT TRACK AT FLOOR PANEL FASTENER HOLE B/S 713.5, RBL 59.5, WL 208. REPAIRED SEAT TRACK IAW SRM 53-00-52-2R 9, FIG 201.SDR IPXA10560552Cover Plate · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY, BS1048, LBL26, WL208 FASTENER HOLE CORRODED. R & R COVER PLATE IAW SRM 51-40-02.SDR IPXA10560535Floorbeam · corrodedINSPECTION TYPE:C3, FLOORBEAM UPPER SURFACE CORRODED AT FASTENER HOLES BS 1540, LBL 25 TO 45, WL 208. REPAIR FLOORBEAM IAW ER NR10-2918.SDR IPXA10560301Intercostal · gougedINSPECTION TYPE:C3, DAMAGED/GOUGED INTERCOSTAL UPPER CHORD, BS 483, RBL 52.5, WL 208. REMOVED, FABRICATED, INSTALLED CHORD IAW SRM.SDR IPXA10560113Floor Panel · damagedINSPECTION TYPE:C3, MAIN DECK FLOOR PANEL STA 1680-1720 LBL 62 - BL 0. DAMAGED ON INBD FWD CORNER. DAMAGE BEYOND REPAIRABLE LIMITS. FABRICATED REPLACEMENT PANEL.SDR IPXA10560112Floorboard · damagedINSPECTION TYPE:C3, MAIN DECK FLOORBOARD STA 1680-1720, RBL 62 TO BL 0 HAS NUMEROUS MISSING INSERTS. DAMAGE BEYOND REPAIRABLE LIMITS. FABRICATED REPLACEMENT FLOORBOARD.SDR IPXA10560082Floor Panel · brokenINSPECTION TYPE:C3, FLOORBOARD BROKEN AT BS 1460-RBL 45-60, WL 208. DAMAGE BEYOND REPAIRABLE LIMITS. FABRICATED REPLACEMENT PANEL.SDR IPXA10560081Floor Panel · puncturedINSPECTION TYPE:C3, FLOOR PANEL FROM BS 1420-1540, LBL 25-45, WL 208 HAS PUNCTURE ON LOWER SURFACE. DAMAGE BEYOND REPAIRABLE LIMITS. FABRICATED REPLACEMENT FLOOR PANEL.SDR IPXA10560080Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL FROM BS 1420-1540, LBL 45-60, WL 208 DAMAGED AT 2 INSERT LOCATIONS. DAMAGE BEYOND REPAIRABLE LIMITS. FABRICATED REPLACEMENT PANEL.SDR IPXA10560079Floor Panel · damagedINSPECTION TYPE:C3, MAIN CARGO BAY BS 1152, LBL 60, WL 208, FLOORBOARD INSERT MISSING, DAMAGE BEYOND REPAIRABLE LIMITS. FABRICATED REPLACEMENT FLOOR PANEL.SDR IPXA10560078Floor Panel · damagedINSPECTION TYPE:C3, MAIN CARGO BAY BS 1126, LBL 60, WL 208 FLOORBOARD INSERT MISSING, DAMAGE BEYOND REPAIRABLE LIMITS. FABRICATED REPLACEMENT FLOOR PANEL.SDR IPXA10560077Floor Panel · damagedINSPECTION TYPE:C3, MAIN CARGO BAY, BS 1120 LBL 10.5 WL 208 FLOORBOARD MISSING INSERT DAMAGE BEYOND REPAIRABLE LIMITS. FABRICATED REPLACEMENT FLOOR PANEL.SDR IPXA10560076Floor Panel · damagedINSPECTION TYPE:C3, MAIN CARGO BAY, BS 1045-LBL 26 WL 208 FLOOR BOARD INSERT MISSING, DAMAGE BEYOND REPAIRABLE LIMITS. FABRICATED REPLACEMENT PANEL.SDR IPXA10560075Floor Panel · damagedINSPECTION TYPE:C3, MAIN CARGO BAY, BS 1048, LBL 60, WL 208 FLOORBOARD INSERT DAMAGED. DAMAGE BEYOND REPAIRABLE LIMITS. FABRICATED REPLACEMENT PANEL.SDR IPXA0560631Crease Beam · corrodedINSPECTION TYPE:C3, MCB INBD CHORD OF CREASE BEAM HAS CORROSION ON UPPER SURFACE, BS 624 TO 635, LBL 63, WL 208. REPAIR CREASE BEAM IAW ER 10-2956.SDR IPXA0560629Frame · chafedINSPECTION TYPE:C3, FRAME CHAFED AT BS377.7 RT BETWEEN STRINGER 22R AND 23R. REPAIRING FRAME IAW ER 10-2942.
Back to N422UP