N422UP
Service difficulty reports · 271
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N422UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N422UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA0560616Stop Pin · gougedINSPECTION TYPE:C3, MCB CARGO DOOR CUTOUT STRUCTURE, UPPER STOP PIN FTG AT BS480 IS GOUGED. R & R STOP PIN IAW SRM 51-40-02-0G.SDR IPXA0560615Stop Pin · gougedINSPECTION TYPE:C3, MCD CARGO DOOR CUTOUT STRUCTURE, UPPER STOP PIN FTG AT BS 620 IS GOUGED. R & R GOUGED STOP PIN SRM51-40-02 0G.SDR IPXA10560564Floorbeam · corrodedINSPECTION TYPE:C3, MCB FLOOR SUPPORT HAS CORROSION ON UPPER SURFACE BS 900 LBL 5-20, WL 208. R & R PLATE IAW SRM 51-40-02.SDR IPXA10560562Floorbeam · corrodedINSPECTION TYPE:C3, MCB FLOOR SUPPORT HAS CORROSION ON UPPER SURFACE BS 900, LBL 5-20, WL 208. R & R PLATE IAW SRM 51-40-02.SDR IPXA10560442Web · corrodedINSPECTION TYPE:C3, CORROSION ON CABIN FLOOR SHEAR WEB STA 1681 RBL 29 TO RBL 38. REMOVED DAMAGE AT DECK PLATE FABRICATED DOUBLER AND FILLER FROM 2024-T3 AND INSTALLED IAW NR 10-2949.SDR IPXA10560438Seat Track · corrodedINSPECTION TYPE:C3 SEAT TRACK CORRODED ON INBD AND OTBD FLANGE NUMEROUS AREAS AT BS 341-425, RBL 45, WL 208. REMOVAL FABRICATED AND INSTALLED SEAT TRACK IAW SRM 51-40-02-0G, SRM 51-40-02-0G, SRM 51-24-03-01.SDR IPXA10560334Sill · corrodedINSPECTION TYPE:C3, CORROSION ON MOP SILL ANGLE UPPER SURFACE STA 1673, RBL 62, WL 208. CORROSION REMOVAL BEYOND ACCEPTABLE LIMITS. FABRICATED AND REPLACED ANGLE IAW SRM.SDR IPXA10560085Intercostal · dentedINSPECTION TYPE:C3, MCB INTERCOSTAL DENTED ON UPPER SURFACE AT BS 483 LBL38 WL 208. DENT BEYOND REPAIRABLE LIMITS. FABRICATED AND INSTALLED REPLACEMENT PER SRM 53-30-51SDR IPXA10560074Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL FROM STA 1200 TO 1320 LBL 24-LBL 45 INBD AFT EDGE HAS INSERT TORN OUT. DAMAGE BEYOND REPAIRABLE LIMITS. FABRICATED REPLACEMENT PANEL.SDR IPXA10560073Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL FROM STA 1200 TO 1320 LBL 10 TO LBL 24 FWD EDGE HAS INSERT TORN OUT. DAMAGE BEYOND REPAIRABLE LIMITS. FABRICATED REPLACEMENT FLOOR PANEL.SDR IPXA10560072Floor Panel · delaminatedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS DELAMINATION AND EDGE DAMAGE BS 879-900 LBL 45-60 WL 208. DAMAGE BEYOND REPAIRABLE LIMITS. FABRICATED REPLACEMENT PANEL.SDR IPXA10560071Floor Panel · delaminatedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS DELAMINATION ON LOWER SURFACE BS 720-BS 820 LBL 25-45 WL 208. DAMAGE BEYOND REPAIRABLE LIMITS. FABRICATED REPLACEMENT PANEL.SDR IPXA10560070Floor Panel · brokenINSPECTION TYPE:C3, MCB FLOOR PANEL BROKEN AT 2 EA INSERT LOCATIONS, BS 720-820 LBL 45-60 WL 208. DAMAGE BEYOND REPAIRABLE LIMITS. FABRICATED REPLACEMENT PANEL.SDR IPXA10560069Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS EDGE DAMAGE, BS 620 TO BS 720, LBL 25 TO LBL 45, WL 208. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A FIG 101, UPS EO NO B757-5320-9692-G.SDR IPXA10560068Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS EDGE DAMAGE BS 560-BS 620, LBL 26-LBL 44, WL 208. DAMAGE BEYOND REPAIRABLE LIMITS. FABRICATED REPLACEMENT PANEL.SDR IPXA10560749Frame · gougedINSPECTION TYPE:C3, MAIN CARGO BAY FRAME INNER FLANGE HAS A SCREW GOUGE BS 1500, STR 15R. REPAIR IAW SRM 53-00-07 AND ER NR10-2964.SDR IPXA10560748Frame · gougedINSPECTION TYPE:C3, MAIN CARGO BAY FRAME INNER FLANGE HAS A SCREW GOUGE BS 1340 STR 15R. REPAIR IAW SRM 53-00-07 AND ER NR10-2964.SDR IPXA10560745Bullnose · chafedINSPECTION TYPE:C3, RT WING OTBD FWD FLAP BULL NOSE IS CHAFED AT INBD END, APPROX 6 INCHES LONG. REPAIREDIAW ATS ER 10-2927.SDR IPXA10560734Skin · gougedINSPECTION TYPE:C3, RT WING OTBD L/E BELL NOSE SKIN IS GOUGED AT OTBD SIDE OF OTBD TRACK CARRIDGE, APROX 5 INCHES LONG. REMOVED L/E PANEL. RECEIVED NEW L/E PANEL ALODINED AND PRIMED INSTALLED IAW 57-53-0-1A1, SRM51-40-08-0G, SRM 51-40-05-0G.SDR IPXA10560732Frame · damagedINSPECTION TYPE:C3, SCREW DAMAGE ON INBD SURFACE OF FRAME STA 480 AT STR 5R AND 15R. REPAIRED IAW ATS ER 10-2928.SDR IPXA10560731Frame · damagedINSPECTION TYPE:C3, SCREW DAMAGE ON INBD SURFACE OF FRAME STA 780 AT STR 5R AND 15R. REPAIRED PER ATS ER 10-2928.SDR IPXA10560730Frame · damagedINSPECTION TYPE:C3, SCREW DAMAGE ON INBD SURFACE OF FRAME STA 540 AT STR 5R. REPAIR IAW ATS ER 10-2928.SDR IPXA10560715Bullnose · chafedINSPECTION TYPE:C3 LT WING OTBD MAIN FLAP INBD BULLNOSE IS CHAFED. REPAIRED FLAP NOSE SKIN IAW ER 10-2935.SDR IPXA10560699Frame · damagedINSPECTION TYPE:C3, SCREW DAMAGE ON INBD SURFACE OF FRAME STA 860 AT STR 5L AND 15L. REPAIRED IAW ATS ER NR 10-2966, DATED 17 JUNE 2010.SDR IPXA0560628Frame · gougedINSPECTION TYPE:C3, MAIN CARGO BAY FRAME INNER FLANGE IS GOUGED BS1681, STR15L. REPAIR FRAME IAW ER 10-2962.SDR IPXA0560617Frame · gougedINSPECTION TYPE:C3, MAIN CARGO BAY FRAME INNER FLANGE HAS A SCREW GOUGE, BS 1220 STR 15L. REPAIR IAW ATS ER 10-2937.SDR IPXA10560505Frame · gougedINSPECTION TYPE:C3, FRAME AT BS 1060 BETWEEN STR 15L-16L HAS SCREW START. REMOVED DAMAGE AND TAPERED AREA IAW B757-53-10-38-185-A.SDR IPXA10560504Skin · gougedINSPECTION TYPE:C3, RT. WING OTBD L/E BULL NOSE SKIN IS GOUGED AT OTBD SIDE OF OTBD TRACK CARRIAGE APROX 5 INCHES LONG. REMOVED L/E PANEL. RECEIVED NEW L/E PANEL ALODINED AND PRIMED INSTALLED IAW 57-53-0-1A1, SRM 51-40-08-0G, SRM 51-40-05-0G.SDR IPXA10560439Frame · gougedINSPECTION TYPE:C3, FRAME AT BS 1140 BETWEEN STR 15R TO STR 16R HAS SCREW START GOUGE FOUND TO BE OUT OF LIMITS. BLENDED AREA AND TAPERED IAW EO B757-5310-38191-A.SDR IPXA10560153Web · gougedINSPECTION TYPE:C3, MAIN CARGO DOOR WEB IS GOUGED 17 INCHES FROM FWD END AND 5.5 INCHES FROM LOWER END. REMOVAL, RECEIVED AND HEAT TREATED PANEL. INSTALLED IAW SRM 51-40-05-0G, AMM 51-20-04-7.SDR IPXA10560744Frame · gougedINSPECTION TYPE:C3, FUSELAGE UPPER LOBE BS 440 APPROX STR 10 LT - GOUGE IN FRAME INBD FACE. REPAIRED IAW ATS ER 10-2930.SDR IPXA10560743Frame · gougedINSPECTION TYPE:C3, FUSELAGE UPPER LOBE BSTA 440 APPROX STR 11 LT - GOUGE IN FRAME INBD FACE. REPAIR IAW ATS ER 10-2930.SDR IPXA10560742Frame · gougedINSPECTION TYPE:C3, FUSELAGE UPPER LOBE BS 440 APPROX STR 12 LT - GOUGE IN FRAME INBD FACE. REPAIR IAW ATS ER 10-2930.SDR IPXA10560729Frame · gougedINSPECTION TYPE:C3, FUSELAGE UPPER LOBE BSTA 440 APPROX STR 8 RT - GOUGE IN FRAME INNER FACE. REPAIR IAW ATS ER 10-2928.SDR IPXA10560728Frame · gougedINSPECTION TYPE:C3, FUSELAGE UPPER LOBE BSTA 440 APPROX STR 7 RT - GOUGE IN FRAME INNER FACE. REPAIRED IAW ATS ER 10-2928.SDR IPXA10560727Frame · gougedINSPECTION TYPE:C3, FUSELAGE UPPER LOBE BSTA 440 APPROX STR 15 RT - GOUGE IN FRAME INNER FACE. REPAIRED IAW ATS ER 10-2928.SDR IPXA10560726Frame · gougedINSPECTION TYPE:C3, FUSELAGE UPPER LOBE BS 220 APPROX STR 6 RT - GOUGE IN FRAME INNER FACE. REPAIRED IAW ATS ER 10-2928.SDR IPXA10560725Frame · gougedINSPECTION TYPE:C3, FUSELAGE UPPER LOBE BS 440 APPROX STR 11 RT - GOUGE IN FRAME INNER FACE. REPAIR IAW ATS ER 10-2928.SDR IPXA10560714Frame · gougedINSPECTION TYPE:C3, FUSELAGE UPPER LOBE B, STA 440 APPROX STR 15 LT - GOUGE IN FRAME INBD FACE. REPAIR IAW ER 10-2911.SDR IPXA10560713Floor Panel · damagedINSPECTION TYPE:C3, FLOOR BOARD AT BS 345-440 BL 0-RBL 25 IS DAMAGED ON LWR SURFACE. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692.SDR IPXA10560680Frame · gougedINSPECTION TYPE:C3 MAIN CARGO BAY FRAME INNER FLANGE HAS A SCREW GOUGE BS 440, STR 5-6L. REPAIRED IAW ATS ER NR 10-2929.SDR IPXA0560630Frame · gougedINSPECTION TYPE:C3, FUSELAGE UPPER LOBE BSTA 365 APPROX STR 15 LT - GOUGE IN FRAME INBD FACE. REPAIRED FRAME WEB IAW ER 10-2925.SDR IPXA0560626Seat Track · corrodedINSPECTION TYPE:C3, SEAT TRACK IS CORRODED AND CRACKED AT BS 341 RBL 1 WL 208. R & R CORRODED SEAT TRACK IAW SRM51-40-02-0G.SDR IPXA0560621Seat Track · corrodedINSPECTION TYPE:C3, SEAT TRACK IS CORRODED AND CRACKED AT BS 341, RBL1, WL208. R & R CORRODED SEAT TRACK IAW SRM 51-40-02-0G.SDR IPXA10560594Frame · gougedINSPECTION TYPE:C3, FUSELAGE UPPER LOBE B, STA 440 APPROX STR 15 LT - GOUGE IN FRAME INBD FACE. REPAIR IAW ATS ER NR 10-2911.SDR IPXA10560578Seat Track · corrodedINSPECTION TYPE:C3, SEAT TRACK IS CORRODED AT BS 380, LBL 24, WL 208. CORROSION CLEAN UP BEYOND ACCEPTABLE LIMITS. REPAIRED SEAT IAW E.O.SDR IPXA10560551Floorbeam · corrodedINSPECTION TYPE:C3, FLOOR PANEL SUPPORT IS CORRODED AT BS 397, RBL 22, WL 208. R & R SUPPORT IAW SRM 51-40-02.SDR IPXA10560508Floorbeam · corrodedINSPECTION TYPE:C3, FLOORBEAM UPPER CHORD IS CORRODED AT BS 310, LBL 58, WL 208. REPAIR FLOORBEAM IAW ATS ER NR 10-2868.SDR IPXA10560507Floorbeam · corrodedINSPECTION TYPE:C3, FLOORBEAM UPPER CHORD IS CORRODED AT FASTENER HOLES COMMON TO FLOOR BOARD PANEL HOLES, BS 310, RBL 7 TO LBL 17, WL 208. REPAIRED FLOORBEAM IAW ATS ER NR 10-2868.SDR IPXA10560422Shear Web · corrodedINSPECTION TYPE:C3, FLOOR SHEAR WEB IS CORRODED IN SEVERAL AREAS FROM BS 341-418 BETWEEN RBL 25 AND RBL 45, WL 208. CORROSION REMOVAL BEYOND ALLOWABLE LIMITS. FABRICATED AND INSTALLED REPLACEMENT WEB IAW SRM.