N425UP

Service difficulty reports · 222

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N425UP' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR IPXA10562933Shear Web · crackedINSPECTION TYPE:C3, WHILE WORKING CUSTOMER CARD 909586 FOUND CRACK IN AFT SHEAR WEB AT BS 1684, RBL 4.4, WL 208. REPAIRED IAW ER 10-04698.Sep 22, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562912Shear Web · corrodedINSPECTION TYPE:C3, CORROSION ON SHEAR WEB AT BS 429, LBL 47, WL 208. REPAIRED IAW EO B757-5310-39684-A AND ATS ER 10-4514.Sep 20, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562911Shear Web · corrodedINSPECTION TYPE:C3, CORRROSION ON SHEAR WEB AT BS 429, LBL 47, WL 208. REPAIRED IAW EO B757-5310-39684-A AND ATS ER 10-4514.Sep 20, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562880Wedge · dentedINSPECTION TYPE:C3, NR 6 SLAT T/E WEDGE LOWER SURFACE HAS 2 EA OUT OF LIMIT DENTS 5.5" TO 6.5" FROM OTBD END AND 1.5" TO 4.5" FROM AFT END. REPAIRED IAW SRM 51-70-10-2R.Sep 18, 2010 · N425UP · Boeing 75724APF · Leading Edge DevicesSDR IPXA10562837Support · crackedINSPECTION TYPE:C3, 9G WALL SUPPORT CLIP BS 331 STR 1 IS CRACKED IN HALF FABRICATED AND REPLACED WALL SUPPORT CLIP IAW DWG 141N8210, SRM51-30-01-0G, SRM 51-40-02-0G, SRM 51-40-05-0G.Sep 18, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562695Floorbeam · corrodedINSPECTION TYPE:C3, MCB FLOOR PANEL SUPPORT COVER PLATE UPPER SURFACE CORRODED STA 1020, BL 0 TO LBL 25. R & R SUPPORT PLATE IAW SRM 51-40-02-0GSep 18, 2010 · N425UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10562641Floorboard · damagedINSPECTION TYPE:C3, MAIN CARGO COMPARTMENT FLOORBOARD HAS DAMAGED CORE AND INSERTS BS 1420 TO 1520 LBL 25 - 45. FABERICATED FLOOR PANEL IAW EO B757-5320-9692.Sep 17, 2010 · N425UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10562662Floor Panel · damagedINSPECTION TYPE:C3, DAMAGED FLOOR PANEL AT BS 820 TO BS 880, RBL 45 TO RBL 60. R & R FLOOR PANEL IAW EO NR B757-5320-9692-G.Sep 16, 2010 · N425UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10562642Floorboard · damagedINSPECTION TYPE:C3, DAMAGED FLOOR PANEL AT BS 1420 TO BS 1540, LBL 45 TO 60. FABRICATED FLOOR PANEL IAW EO B757-5320-9692.Sep 16, 2010 · N425UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10562792Seat Track · corrodedINSPECTION TYPE:C3, MAIN CARGO COMPARTMENT, CORROSION ON SEAT TRACK, BS 341 BL 0. FABRICATED AND INSTALLED NEW SEAT TRACK IAW SRM 53-00-52-1A, SRM 51-40-02-0G, SRM 51-40-06, SRM 51-40-05, SRM 51-40-08-0G.Sep 11, 2010 · N425UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10562593Shear Web · corrodedINSPECTION TYPE:C3, CORROSION ON UPPER SURFACE OF DOUBLER, ATTACHED TO LOWER SURFACE OF MCB SHEAR WEB AT BS 351 AND BS 363 LBL 11, WL 208. REMOVED, FABRICATED AND INSTALLED REPLACEMENT SPLICE PLATE IAW SRM 51-40-02.Sep 11, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562790Strap · damagedINSPECTION TYPE:C3, BS 333 S1-2L RIGID BARRIER TENSION STRAP HAS ELONGATED HOLE AT FWD ATTACH POINT. REPAIR IAW ER 10-4508.Sep 10, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562789Strap · damagedINSPECTION TYPE:C3, BS 333 S2-3R RIGID BARRIER TENSION STRAP HAS ELONGATED HOLES AT FWD ATTACH POINT. REPAIR PER ER 10-4508.Sep 10, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562788Strap · damagedINSPECTION TYPE:C3, BS 333 S1-2R RIGID BARRIER TENSION STRAP HAS ELONGATED HOLES AT FWD ATTACH POINT. REPAIR IAW ER 10-4508Sep 10, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562645Frame · damagedINSPECTION TYPE:C3, FRAME SCREW STRIKE BS 365, STR 14 LT. R & R FRAME SPLICE IAW SRM 51-40-02-0G.Sep 9, 2010 · N425UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10562921Shear Web · corrodedINSP TYPE:C3, INTERIOR FLOOR SHEAR WEB HAS CORROSION STA 342 TO 377, RBL 0 TO 25. REPAIRED IAW ATS ER 10-4572.Sep 7, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562917Shear Web · corrodedINSPECTION TYPE:C3, RBL 33, BS 1715 SHEAR WEB IS CORRODED. REPAIRED IAW ER 10-4469 DATED 9/29/10 AND EO B757-5310- 39931-A, DATED 9/30/10.Sep 7, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562914Shear Web · corrodedINSPECTION TYPE:C3, MCB SHEAR WEB FLOOR STRUCTURE IS CORRODED AT BS 349 LBL 59.5 WL 208. REPAIRED IAW ER 10-4514 AND EO B757-5310-39684-A.Sep 7, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562913Shear Web · corrodedINSPECTION TYPE:C3, MCB SHEAR WEB FLOOR STRUCTURE HAS CORROSION IN NUMEROUS AREAS FROM BS 338 - 440 LBL 47.25 TO LBL 50, WL 208. REPAIRED IAW EO B757-5310-39684-A AND ATS ER 10-4514.Sep 7, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562900Shear Web · corrodedINSPECTION TYPE:C3, FLOOR WEB SHEAR WEB HAT CHANNEL FLANGES HAS CORROSION BS 342 LBL 12-14. REPAIR IAW ER 10-4556 DATED 9/28/10.Sep 7, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562897Shear Web · corrodedINSPECTION TYPE:C3, LBL 22 TO LBL 29 BS 1716 SHEAR WEB IS CORRODED. REPAIRED IAW ER 10-4659 DATED 10-01-10.Sep 7, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562895Shear Web · corrodedINSPECTION TYPE:C3, LBL 22 TO LBL 29 BS 1716 SHEAR WEB IS CORRODED. REPAIRED IAW ER 10-4659 DATED 10-01-10.Sep 7, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562892Channel · corrodedINSPECTION TYPE:C3, FLOOR WEB SHEAR WEB HAT CHANNEL FLANGES HAS CORROSION BS 342, LBL 12-14. REPAIR IAW ATS ER 10-4556, DATED 9-28-10.Sep 7, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562884Floorbeam · corrodedINSPECTION TYPE:C3, LBL 25 TO BL 0 BS 1200 FLOORBEAM IS CORRODED. REPAIRED IAW ATS ER 10-4493, DATED 9-29-10.Sep 7, 2010 · N425UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10562883Floorbeam · corrodedINSPECTION TYPE:C3, LBL 53 TO LBL 48 BS 1200 FLOORBEAM IS CORRODED. REPAIRED IAW ATS ER 10-4493, DATED 9-29-10.Sep 7, 2010 · N425UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10562791Floorbeam · corrodedINSPECTION TYPE:C3, LBL 41, BS 1600 FLOORBEAM IS CORRODED. REPAIRED FLOORBEAM IAW SRM 51-10-02-G AND ER 10-4500Sep 7, 2010 · N425UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10562770Seat Track · corrodedINSPECTION TYPE:C3, LBL 25, BS 1180 TO 1200 SEAT TRACK FLANGE IS CORRODED AT NUTPLATES. REPAIRED IAW SRM 51-40-02-0G, EO B757-5340-20264-B.Sep 7, 2010 · N425UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10562769Seat Track · gougedINSPECTION TYPE:C3, RBL 45, BS 1272 SEAT TRACK IS GOUGED. REPAIRED IAW SRM 53-00-52-1A1, 51-40-02-0G, 51-40-05-0G.Sep 7, 2010 · N425UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10562751Floorbeam · corrodedINSPECTION TYPE:C3, LATERAL FLOORBEAM UPPER CHORD SURFACE IS CORRODED AT BS 310, LBL 10, WL 208. REPAIRED IAW ATS ER-10-4474.Sep 7, 2010 · N425UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10563168Floor Support · crackedINSPECTION TYPE:C3, BS 483, RBL 12, FLOOR SUPPORT IS CRACKED. REPLACED IAW DWG 284N1020, SRM 51-40-05, 51-40-02.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562916Seat Track · corrodedINSPECTION TYPE:C3, BS 600 TO 620, RBL 45 SEAT TRACK FLANGE HAS CORROSION AT NUTPLATE HOLES. REPAIRED IAW EO B757-5310-39911-A, DATED 9/29/10 AND ER 10-4557 DATED 9/28/10.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10562915Floor Support · damagedINSPECTION TYPE:C3, MECHANICAL DAMAGE TO FLOOR SUPPORT BETWEEN BS 310-324, RBL 13, WL 208. REPLACED SUPPORT IAW SRM 51-40-02-0G, SRM 51-40-05-0G, SRM 51-40-08-0G, MM 51-21-02-7, DWG 141N5140.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562908Seat Track · corrodedINSPECTION TYPE:C3, BS 620 TO 560 LBL 25 SEAT TRACK FLANGE CORRODED AT NUTPLATE HOLES. REPAIRED IAW SRM 53-00-52-2R-5.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10562904Floorbeam · corrodedINSPECTION TYPE:C3, BS 620, RBL 45 TO LBL 45 FLOORBEAM IS CORRODED. REPAIR IAW 10-4485.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10562898Shear Web · corrodedINSPECTION TYPE:C3, BS 460, LBL 65 SHEAR WEB CHORD IS CORRODED. REPAIR IAW ER 10-4506.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562891Floorbeam · corrodedINSPECTION TYPE:C3, BS879, RBL45 TO RBL 60 FLOORBEAM IS CORRODED. REPAIR IAW ATS ER 10-4496, DATED 9-30-10.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10562871Crease Beam · damagedINSPECTION TYPE:C3, MECHANICAL DAMAGE INBD CHORD, OTBD SURFACE BS 629 LBL 65 WL 208. R & R CREASE BEAM INBD CHORD IAW SRM 51-40-02.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Main, StructureSDR IPXA10562854Floor Support · damagedINSPECTION TYPE:C3, MECHANICAL DAMAGE TO FLOOR SUPPORT BETWEEN BS 299-310 RBL 13 WL 208. REMOVED, FABRICATED AND INSTALLED NEW FLOOR SUPPORT CHANNEL IAW SRM 51-40-02, SRM 51-20-01 AND DWG NR141N3140.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10562744Floorbeam · crackedINSPECTION TYPE:C3, BS 483, RBL 12 FLOOR SUPPORT IS CRACKED. REPLACED IAW DWG 284N1020, SRM 51-40-05, 51-40-02.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10562643Floorboard · damagedINSPECTION TYPE:C3, MAIN CARGO FLOORBOARD BS 1600-1680, LBL 45 TO LBL 65, MISSING INSERT AND MULTIPLE PUNCTURES. FABRICATED REPLACEMENT FLOOR BOARD IAW EO NR B757-5320-9692-G.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10562628Floorboard · damagedINSPECTION TYPE:C3, MAIN CARGO FLOORBOARD STA 1540-1600, BL0, RBL25, 4 DAMAGED INSERTS. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10562624Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL STA 900-1020 RBL 45-60 HAS MISSING INSERTS AT STA 1020. R & R FLOOR PANEL IAW EO B757-5320-9692-G.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10562622Floorboard · puncturedINSPECTION TYPE:C3, MAIN CARGO FLOORBOARD STA 1580-1600 RBL 45 TO RBL 65 DEBONDED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10562602Floor Panel · damagedINSPECTION TYPE:C3, FOUND FLOORBOARD STA 900-1020, LBL 45-65 LT HAS DAMAGED INSERT FWD OTBD EDGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G, EO NR B757-5100-33281-B.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10562600Floor Panel · puncturedINSPECTION TYPE:C3, MAIN CARGO FLOORBOARD PANEL BS 1200-1320, BL 0 TO LBL 25, 2 PUNCTURES IN THE UNDERSIDE. REPLACED FLOOR PANEL IAW EO NR B757-5320-9692-G AND EO NR B757-5100-33281-B.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10562592Floor Panel · puncturedINSPECTION TYPE:C3, MAIN CARGO FLOORBOARD BS 1320-1420, BL0-LBL 25, 2 PUNCTURES IN THE UNDERSIDE. REPLACED IAW EO B757-5320-9692-G, B757-5100-33281-B.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10562590Floor Panel · puncturedINSPECTION TYPE:C3, FOUND FLOOR PANEL STA 900-1020 RBL 25-45 HAS PUNCTURE DAMAGE UNDERSIDE OTBD AT STA 1000. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10562589Floorbeam · puncturedINSPECTION TYPE:C3, BS 900 LBL 25-45 FLOOR SUPPORT PUNCTURED. REMOVED, FABRICATED AND INSTALLED PLATE IAW SRM 51-40-02.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10562588Floor Panel · puncturedINSPECTION TYPE:C3, MAIN CARGO FLOORBOARD STA 1420-1540, LBL 25-45, 2 PUNCTURES ON THE UNDERSIDE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10562561Floor Panel · debondedINSPECTION TYPE:C3, MAIN CARGO FLOOR PANEL BS 1200-1320, BL0 TO RBL 25 DISBONDED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.Sep 6, 2010 · N425UP · Boeing 75724APF · Fuselage Floor Panel
Back to N425UP