N428UP
Service difficulty reports · 163
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N428UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N428UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2021071571722Seal · leakingINSPECTION TYPE:N/APRESSURIZATION LEAK - MAIN CABIN ENTRY DOOR - LOUD "WHISTLE" APPROX 7.0 - 8.3 PSI.PERF T/S IAW FIM 52-FAULT CODE DIAGRAM FIG 2 REV 127.00. FOUND NO DAMAGES AT DOOR SEALS OR DOOR FRAMES. EXCESSIVE CABIN PRESSURE LEAKAGE TEST PERF IAW AMM 05-5SDR IPXA2020062977044Fitting · corrodedINSPECTION TYPE:SEG, NR 2 PYLON I/B DRAG LINK FITTING HAS CORROSION IN UPPER MOUNT HOLES. REPLACED FITTINGSDR IPXA2020062977043Fitting · corrodedINSPECTION TYPE:SEG, NR 2 OB PYLON DRAG FITTING HAS CORROSION IN MOUNT HOLES. REPLACED FITTINGSDR IPXA2020060856197Floor Panel · damagedINSPECTION TYPE:SEG MCD FLOOR PANEL 232XWF DAMAGED. FABBED NEW FLOOR PANEL FROM 5024N400001SS-5 BATCH 354653 PER SREO B757-5320-9692-K.SDR IPXA2020060856196Floor Panel · damagedINSPECTION TYPE:SEG MCD FLOOR PANEL 232XFF. FABBED PANEL 232XFF FROM 5024N40001-G BATCH# 3346253 PER SREO B757-5320-9692-K.SDR IPXA2020042454602Adc · failedINSPECTION TYPE:N/A** EMERGENCY DECLARED ** LANDED WITHOUT INCIDENT ** ON ROTATION ON TAKE OFF OUT OF LAN THE LEFT CAPT FLT INSTRUMENTS AND AIRSPEED INDICATIONS ERRONOUS FO WAS PILOT FLYING RECIEVED OVERSPEED AND WINSHEASR WARNINGS AND AIRSPEED WENT TO THE TOPSDR IPXA2019090346277Cooling Fan · malfunctionedINSPECTION TYPE:N/A EQUIP COOLING OVHT WHILE ALREADY IN ALT ON THE TAXI IN WITH SMELL OF SMOKE. INTERCHANGED EQPT CLG FANS B10 AND B11 IAW AMM 21-58-06 PAGE BLOCK 401. REV 04/15/19. FAN #1 S/N NOW 1189 FAN #2 S/N NOW 1738. CONTINUED LP 230492 ITEM 2. A/C OK FOSDR IPXA2019071644527Engine · shutdownINSPECTION TYPE:N/A DURING TAXI ONTO RNWY 22 AT STN, #1 (LEFT SIDE ) ENG EXPERIENCED AN UNCOMMANDED SHUT DOWN.TEST 15, FUEL CONTROL TEST C/W IAW AMM 71-00-00-735-328-O00, NO FAULTS NOTED.SDR IPXA2019051542130A/C Pack · odorINSPECTION TYPE:N/A STRONG ODOR FROM PACK OPS BOTH ENGINES AND APU. R PACK DEFERRED IAW MEL 21-51-1. ITEM DEFERRED TO M669993. PLACARD INSTALLED. REF. TO FIM 21-00-01 PB 301 REV 123.00 AND AMM 21-51-00 REV. 123.01. **SUPPLEMENTAL SDR**A/C NOT EQUIPPED WITH RESDR IPXA2019051342088Strap · brokenINSPECTION TYPE:SDR RETAINING STRAPS FOR FIRST AID KIT NOT HOLDING THE KIT IN PLACE. BRACKET ASSY REPLACED IAW IPC 25-64-51-20 ITEM 015 REV 120.01 AND AMM 25-60-00 REV 123.01.SDR IPXA20190401440Exchanger · failedINSPECTION TYPE:N/ATHE RIGHT PACK HAS A STRONG OIL SMELL. OPERATES NORMALLY. DUE TO LATE ARRIVAL OF SPARE PARTS NO SUFFICIENT GND. TIME. ITEM DEFFERED, IAW MEL 21-51-1 REV 73. PLACARD INSTALLED. ** SUPPLEMENTAL SDR **SECONDARY HEAT EXCHANGER REPLACED IAW AMM 2SDR IPXA2019012538304A/C Pack · contaminatedINSPECTION TYPE:N/A BOTH AIR CONDITIONING PACKS HAVE A BAD ODOR. FOUND DEICING FLUID IN INTAKE OF BOTH AIR CONDITIONS. CLEANED BOTH AREA AND RUN PACKS FOR APPROX 1.0 HOURS IAW AMM 21-00-00-862-001. ALL OPS NORMAL. NO EVIDENCE OF SMELL.SDR IPXA2018120766655Control Lever · bindingDUE TO FLAP DISAGREE IAW FIM 27-51-00-815-808, FOUND FLAP CONTROL LEVER BINDING AT THE ZERO POSITION. LUBRICATED THE FLAP HANDLE IAW FIM 27-51-00/101. IAW AMM 27-51-00-715-001. OPS CHECKED GOOD.SDR IPXA2018060830409Sensor · out of adjustLEFT FWD DOOR EICAS ILLUMINATED IN FLIGHT, AT CRUISE ALTITUDE. THE DOOR WAS CLOSED. TWO FASTENERS WERE REPLACED IAW SRM 51-40-02-06, REV 102.00. ADJUSTMENT OF THE SENSOR WAS PERFORMED IAW MM 52-71-00-501. TESTED GOOD.SDR IPXA2018053030162Floor Panel · damagedINSPECTION TYPE:SEG2, MCD FLOOR PANEL 231XJF HAS DAMAGE. FABBED PNL 231XJF FROM A402H-48X144 BATCH 3119029 AND STEP CUT PER SREO B757-5320-9692-KSDR IPXA201805239903Floor Panel · damagedMAIN CARGO BAY FLOOR PANEL 241XDF WAS DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017122724833Charger · inoperativeFOUND EMERGENCY LIGHT NOT WORKING. BATTERY CHARGER REPLACED IAW AMM 33-51-07-022-020, AND AMM 33-51-07-862-054, REV 120.01. BATTERY REPLACED AS WELL IAW AMM 33-51-07-902-001, REV 120.01.SDR IPXA2016091808362Unknown · odorBOTH CREW MEMBERS OBSERVE OIL AND FUMES ORDER FROM AIR VENTS, PACKS RESULTING IN SORE THROATS AND HEADACHES DURING ALL PHASES OF FLIGHT. CHECKED SYS IAW K173513 ALERT. ALL OPS NORMAL. NO OIL AND FUMES NOTED.SDR IPXA2016061504671Pseu · faultyBLOCK TURN BACK DUE TO INTERMITTENT ILLUMINATION OF FWD ENTRY DOOR EICAS WITH FWD ENTRY DOOR FULLY CLOSED AND ALL CAUTIONS, ILLUMINATED LIGHTS EXTINGUISHED. R & R THE PSEU IAW AMM 32-09-04, OPS CHECK GOOD.SDR IPXA2014051682953Floor Support · dentedDURING SG12 INSPECTION, AFT CARGO BAY BS 1458 FLOOR SUPPORT IS DENTED. REMOVED FLOOR SUPPORT FROM BS 1450-1500 IAW SRM 51-40-02-0G. LOCATED DRILLED IAW SRM 51-40-02-06.4.SDR IPXA2014051482941Floor Support · dentedDURING SG12 INSPECTION, AFT CARGO FLOOR SUPPORT BS 1290 DENTED. FOUND OUT OF LIMIT IAW SRM 53-00-53-1A-1. CUTOUT DAMAGED SECTION OF FLOOR SUPPORT FROM BS 1288-1291 IAW SRM 53-00-53-2R-1 DETAIL IV. HFEC INSPECTED CUTOUT IAW NDTM PT6 51-00-19, NO CRACK INDICSDR IPXA3579506Power Supply · inoperativeINSPECTION TYPE: ASE, EMERGENCY LIGHTS DO NOT STAY ON WHEN SWITCH IS PLACED IN ON POSITION. LIGHTS FLICKER FOR ONE SECOND AND GOES OFF. REMOVED POWER SUPPLY IAW 33-51-07-022-020 INSTALLED POWER SUPPLY IAW 33-51-02-862-054 OPS & FUNCTIONAL TEST CHECKED GOOD ISDR IPXA2576352Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL POS 13L DAMAGED. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA12575156Window · inoperativeR2 WINDOW CRANK RATCHETS AND WILL NOT OPERATE WINDOW. REPLACED R2 WINDOW OPERATING MECHANISM IAW MM 56-11-04-404-013.SDR IPXA12573797Frame · dentedINSPECTION TYPE: C11 FWD CARGO BAY FRAME DENTED AT BS 820 S23-24L. REPAIRED IAW SRM 53-00-07, 2R 5, FIG 201, DETAIL 3.SDR IPXA12573795Frame · dentedINSPECTION TYPE: C11, FWD CARGO BAY FRAME DENTED AT BS 820, S24-25R. REPAIRED IAW SRM 53-00-07, 2R 5, FIG 201, DETAIL 3.SDR IPXA12573802Frame · dentedINSPECTION TYPE: C11, FWD CARGO BAY FRAME DENTED AT BS 780, S23 - 24L. REPAIRED IAW SRM 53-00-07 2R 5, FIG 201, DETAIL 1.SDR IPXA12573801Frame · dentedINSPECTION TYPE: C11, FWD CARGO BAY LT SIDE FRAME DENTED AT BS 680 S23 - 24L. REPAIRED IAW SRM 53-00-07, 2R 5, FIG 201, DETAIL 2.SDR IPXA12573800Frame · dentedINSPECTION TYPE: C11 FWD CARGO BAY FRAME DENTED AT BS 800 S24-25L. REPAIRED IAW SRM 53-00-07 2R 5, FIG 201, DETAIL 1.SDR IPXA12573799Frame · dentedINSPECTION TYPE: C11, FWD CARGO BAY FRAME DENTED AT BS 760, S24-25L. REPAIRED IAW SRM 53-00-07 2R 5, FIG 201, DETAIL 1.SDR IPXA12573798Frame · dentedINSPECTION TYPE: C11, FWD CARGO BAY FRAME DENTED AT BS 700 S23-24L. REPAIRED IAW SRM 53-00-07 2R 5, FIG 201, DETAIL 1.SDR IPXA12573796Frame · dentedINSPECTION TYPE: C11, FWD CARGO BAY FRAME DENTED AT BS 700, S24-25R. REPAIRED IAW SRM 53-00-07, 2R 5 FIG 201, DETAIL 3.SDR IPXA10560559Web · crackedINSP TYPE:C2, WEB FROM BS 395-418 CRACKED LBL 45, WL 208-201. REPLACED IAW DWG 141N5150, SRM 53-00-51-1A.SDR IPXA10560597Floor Panel · puncturedINSPECTION TYPE:C2, WHILE WORKING NRC 862022 FOUND FLOOR PANEL BS 330-440 RBL 45 TO RBL 60 PUNCTURED. R & R FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10560596Floor Panel · puncturedINSPECTION TYPE:C2, WHILE WORKING NRC 862022 FOUND FLOOR PANEL BS 333-440 BL-0 TO RBL 25 PUNCTURED. R & R FLOOR PANEL IAW EO NR B757-5320-9692-G.SDR IPXA10560561Floor Panel · puncturedINSPECTION TYPE:C2 FLOOR PANEL BS 440-480 RBL 25 TO RBL 45 WL 208 IS PUNCTURED. REPLACED IAW EO B757-5320-9692G.SDR IPXA10560560Floor Panel · puncturedINSPECTION TYPE:C2 FLOOR PANEL BS 440-480 BL 0 TO RBL 25 WL 208 IS PUNCTURED. REPLACED IAW EO B757-5320-9692-G.SDR IPXA10560388Attach Fitting · brokenINSPECTION TYPE:C2, WHILE REMOVING THE 9-G BARRIER CTR SECTION, FOUND CLIP BROKEN AT BS 335, STR 1 CL. R & R CLIP IAW SRM 51-40-02-0G.SDR IPXA0560651Floor Support · corrodedINSPECTION TYPE:C2, MAIN CARGO STA 340 TO STA 418 LBL 24.75 TO LBL 45.5 SHEAR WEB IS CORRODED NUMEROUS PLACES. REPLACED CORRODED SHEAR WEB IAW SRM 53-00-51-1A SRM 53-00-51-1A.SDR IPXA10560455Tension Tie · misinstalledINSPECTION TYPE:C2 9-G BULKHEAD CTR SECTION TENSION STRAP UPPER ATTACHMENT HOLES ARE DOUBLE DRILLED BETWEEN STRINGER 2L AND 3L. REPAIR IAW ER10-2901.SDR IPXA10560454Tension Tie · misinstalledINSPECTION TYPE:C2, 9-G BULKHEAD CTR SECTION TENSION STRAP UPPER ATTACHMENT HOLES ARE DOUBLE DRILLED BETWEEN STRINGER 1 AND 2L. REPAIR IAW ER10-2901.SDR IPXA10560453Tension Tie · mismanufacturedINSPECTION TYPE:C2, 9-G BULKHEAD CTR SECTION TENSION STRAP UPPER ATTACHMENT HOLES ARE DOUBLE DRILLED BETWEEN STRINGER 1 AND 2R. REPAIR IAW ER NR 10-2901.SDR IPXA10560306Skin · damagedINSPECTION TYPE:C2, FOUND DRILL START IN SKIN AT STR 11, LT BS 1210. DRILLED OUT DAMAGE AT INSTALLED RIVET IN SKIN AT STR 11, LT BS 1210 IAW ER 10-2965.SDR IPXA10560452Tension Tie · mismanufacturedINSPECTION TYPE:C2, 9G BULKHEAD CTR SECTION FOUND TO HAVE 4EA TENSION STRAPS DOUBLE DRILLED, STR 3L-3R. REPAIR IAW ER 10-2901.SDR IPXA10560142Floorboard · damagedINSPECTION TYPE:C2, FLOORBOARD DAMAGED STA 1100 - 1200, RBL 45 - 60 FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10560138Floor Panel · corrodedINSPECTION TYPE:C2, FWD CARGO FLOOR PANEL CORRODED BS 505 TO 545. FABRICATED NEW PANEL IAW SRM 53-00-53-1A.SDR IPXA10560004Floor Panel · damagedINSPECTION TYPE:C2, MAIN CABIN FLOOR PANEL BS 620 TO 720 BL 0 TO LBL 25 IS BROKEN AT INSERT 30 FABRICATED NEW FLOOR PANEL IAW B757-5320-9692-G AND B757-5100-33281-B.SDR IPXA10560090Wedge · chafedINSPECTION TYPE:C2, NR 3 SLAT T/E WEDGE LOWER SURFACE IS CHAFED AT 34 INCHES FROM INBD ABOVE INBD MAIN TRACK. (FOUND OUT OF LIMITS ON CARD 862188) REPAIRED NR 3 SLAT T/E WEDGE IAW SRM 51-70-10-2R-4 REPAIR 4 AND SRM 51-70-10-2R REPAIR GENERAL.SDR IPXA10560208Wedge · damagedINSPECTION TYPE:C2, ATS RESPONSIBILITY - WHILE LOCATED NEW T/E WEDGE FOR RT WING INBD MAIN FLAP ON ACFT. DROPPED T/E WEDGE CAUSING DAMAGE ON OTBD CORNER OF WEDGE. REPAIRED IAW 757-200PS, SRM 51-70-10-2R.SDR IPXA10560444Frame · damagedINSPECTION TYPE:C2, FRAME AT BS 1000, BETWEEN S-15R AND S-16R HAS AN IMPROPERLY INSTALLED FASTENER AND THE ADJACENT FASTENER BELOW HAS A FIGURE EIGHT HOLE. REPAIRED IAW ER 10-2881.