N451UP
Service difficulty reports · 283
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N451UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N451UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2026061121630Strap · corrodedAFT CARGO COMP. CEILING STABILIZATION STRAP HAS CORROSION, APPROX BTW BS 1400 AND BS 1420, RBL 24.75.SDR IPXA2026061122255Strap · corrodedAFT CARGO COMP. CEILING STABILIZATION STRAP HAS CORROSION, APPROX BTW BS 1400 AND BS 1420, RBL 45.50 C/W SDRSDR IPXA2026040115702Floor Support · corrodedAFTER REMOVAL OF FLOOR TAPE FOUND AFT CARGO COMP FLOOR CENTER STRINGER STA 1475 RBL 2 EXFOLIATED INSTALLED 10 EA NUT PLATES ON NEW FLOOR SUPPORT STRINGER AND INSTALLED FLOOR SUPPORT STRINGER AT AFT CARGO STA 1443.6 TO 1495 RBL 2 IAW B757-200 SRM51-40-02-0G-SDR IPXA2026031834297Strap · corrodedAFT CARGO COMP. CEILING STABILIZATION STRAP HAS CORROSION, APPROX BTW BS 1400 AND BS 1420, RBL 45.50, ID STICKER NUM. (085-073). ATA 53-20 INSTALLED CEILING STABILIZATION STRAP, REPLACEMENT SECTION AND 2EA REPAIR SPLICES IN AFT CARGO COMPARTMENT BETWEEN STA SDR IPXA2026030934060Strap · corrodedAFT CARGO COMP. CEILING STABILIZATION STRAP HAS CORROSION, APPROX BTW BS 1400 AND BS 1420, RBL 24.75, ID STICKER NUM. (085-078). ATA 53-20 INSTALLED NEW STABILIZATION STRAP P/N STESAA7003349028-2 FOR AFT CARGO CEILING COMP BETWEEN STA 1360 AND STA 1440 IAW B7SDR IPXA2026040633932Frame · dentedMAJOR REPAIR. AFT CARGO BAY FRAME UPPER ANGLE DENTED, APPROX AT BS 1220, BTW STGR 26L AND STGR 27 L, REPAIR WAS ACCOMPLISHED IAW EO-96988-REQ1 AND VT-SAA EA 757-5360-01-B0699 REV IR PRIOR TO FURTHER FLIGHT.SDR IPXA2026040233747Frame · dentedMAJOR REPAIR, AFT CARGO COMP. FRAME UPPER CHORD HAS 3 EA DENT, APPROX AT BS 1360, BTW STGR 25R AND STGR 27 R, ID STICKER NUM. (085-068). ATA 53-10. REMOVED (3EA) SOLID RIVETS FROM DISCREPANT AREAS AT FS 1360 INBD OF STR 26R FOR ACCESS IAW B757-200PF SRM 51-40-SDR IPXA2026040133784Intercostal · dentedAFT CARGO COMP. INTERCOSTAL HAS A DEFORMATION APPROX BTW BS 1360 AND BS 1380, BTW STGR 24R AND STGR 25 R, ID STICKER NUM. (085-069). ATA 53-10 INSTALLED 1EA. SHIM AND NEW INTERCOSTAL IAW B757-200PF SRM 51-40-02-0G-0.SDR IPXA2026033134415Floorbeam · corrodedMAJOR REPAIR, MAIN DECK CARGO COMP. FLOOR BEAM LWR CHORD HAS CORROSION, APPROX AT BS 1400, BTW RBL 24.75 AND RBL 45.50, ID STICKER NUM. (085-074). ATA 53-10. REMOVED CORROSION AT MAIN CARGO COMP. FLOOR BEAM LWR CHORD APPROX. AT BS 1400, BTW RBL 24.75 AND RBLSDR IPXA2026033134469Floorbeam · corrodedMAJOR REPAIR, MAIN DECK CARGO COMP. FLOOR BEAM LWR CHORD HAS CORROSION, APPROX AT BS 1420, BTW RBL 24.75 AND RBL 45.50, ID STICKER NUM. (085-075). ATA 53-10. REMOVED 5EA ANGLES FROM AFT CARGO COMP. FRAME UPPER CHORD APPROX AT BS 1360, BTW STGR 25R AND STGR 27SDR IPXA2026032721947Floor Panel · corrodedEXFOLIATION FLOOR PANEL RT SIDE AFT CARGO BS 1600-1560, STR 27 AND 28R. REMOVED CORROSION FROM FLOOR PANEL RT SIDE AFT CARGO. MAT LOSS MORE THAN 50%. MAX ALLOWABLE IS 10%. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1 FIG 101. INSTALLED REPAIR DOUBLER IN SDR IPXA2026032803895Splice Angle · corrodedBS 1992 AT THE 6 O`CLOCK POSITION HAD CORROSION BETWEEN FRAME AND SPLICE ANGLE TO INCLUDE SURROUNDING EXTERNAL SURFACES. VERIFIED STEP 10 IAW GMM. INSTALLED REPLACED SPLICE, REINSTALLED DOUBLER AT STA. 1992, 6:0 O'CLOCK PER B757-200PF SRM 51-40-02-0G-0SDR IPXA2026032854460Skin · corrodedAPU, RIGHT DOOR 316 EXTERNAL SKIN EDGE HAS EVIDENCE OF CORROSION AT APPROX BS 1963.8, VERIFIED EO NO DEFERRALS REQUIRED EA 757-5240-01-B0698, REV P1, STEP 16. ACCOMPLISHED REPAIR PER EO-96910-REQ1 AND VT-SAA EA 757-5240-01-B0698, REV IRSDR IPXA2026032033198Bracket · corrodedR/H HORZ STAB OTBD HINGE REAR SPAR TO ELEVATOR FRONT SPAR BONDING STRAP ATTACH BRACKETS HAVE HEAVY CORROSION ALSO BONDING STRAPS CORRODED AND FRAYED. RL032 INSTALLED NEW BRACKET P/N 183N1341- 2SAAU AT R/H HORIZONTAL STAB. O/B HINGE REAR SPAR TO ELEVATOR IAW SDR IPXA2026032433764Bracket · corrodedLEFT HORZ STAB OTBD HINGE REAR SPAR TO ELEVATOR FRONT SPAR BONDING STRAP ATTACH BRACKETS HAVE HEAVY CORROSION LARGE SECTION OF BRACKET AND BONDING STRAPS MISSING. RL039. INSTALLED REPLACEMENT NEW BRACKET, 1EA WEB AND 1EA BONDING STRAP P/N BACJ40E20-20 BATCH 0SDR IPXA2026031433198Attach Bracket · corrodedRIGHT HORZ STAB OTBD HINGE REAR SPAR TO ELEVATOR FRONT SPAR BONDING STRAP ATTACH BRACKETS HAVE HEAVY CORROSION ALSO BONDING STRAPS CORRODED AND FRAYED. RL032 VERIFIED STEP 22SDR IPXA2026031433764Attach Bracket · corrodedL/H HORZ STAB OTBD HINGE REAR SPAR TO ELEVATOR FRONT SPAR BONDING STRAP ATTACH BRACKETS HAVE HEAVY CORROSION LARGE SECTION OF BRACKET AND BONDING STRAPS MISSING. RL039 VERIFIED STEP 20SDR IPXA2025052811205Sign · inoperativeFLIGHT DECK EMERGENCY EXIT SIGN INOP. REMOVED AND REPLACED THE EMERGENCY LIGHT BATTERY IAW B757 AMM 33-51-07. OPS CHECK GOOD.SDR IPXA2025051950196Latch · stiffCAPTAINS SIDE WINDOW LATCH SLIGHTLY STIFF TO OPEN,SEEMS TO NEED A LITTLE LUBRICATION ADJUSTED CAPT #2 SLIDING WINDOW INBD/OTBD LINK ARM ROD END REF AMM TASK 56-11-02-825-001. OPERATED SLIDING WINDOW, NO OBSTRUCTION NOTED. CAPT SLIDING WINDOW OPERATION CHECK GOSDR IPXA2024101482944Battery Pack · inoperativeEMERGENCY LIGHTS INOP REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK AND CHARGER ASSY IAW B757 AMM 33-51-07-902-001, 33-51-07-862-054 AND 33-51-07-612-048 OPS CHECK GOODSDR IPXA2024080808548Sign · inoperativeEMERGENCY EXIT SIGN LIGHTS INOP RELAMPED IAW MM 33-51-01. OPS CKS GOOD. THIS CLEARS 2820838. PLACARDS REMOVED.SDR IPXA2024080508548Light · inoperative*SDR FILED OPEN* EMERGENCY EXIT SIGN LIGHTS INOP DEFERRED PER MEL 33-51-1-1. NO DMP REQUIRED. PLACARD INSTALLED.SDR IPXA2024080129069Door · bindingCREW ENTRY DOOR HARD TO OPEN, DAMPNER SEAL GETTING STUCK IN DOOR JAMB. FOUND LOOSE HARDWARE AT BOTTOM OF DOOR LINER CAUSING DAMPER SEAL TO RUB BOTTOM DOOR FRAME. SECURED HARDWARE AND DAMPER SEAL IAW AMM 20-11-00 AND AMM 52-12-01. OPS CHECK GOOD.SDR IPXA2024080284845Seal · stickingMAIN ENTRANCE DOOR STICKING (HARD TO OPEN) UPON INSP FOUND MAIN ENTRY CREW DOOR LOWER SEAL GETTING STUCK UNDER LINER. SECURED LINER SCREWS IAW MM LINER INSTALLATION SYS OPS CK€™S NORMAL REF MM 52-12-01-401.SDR IPXA2024073084845Seal · bindingMAIN ENTRANCE DOOR STICKING (HARD TO OPEN) UPON INSP FOUND MAIN ENTRY CREW DOOR LOWER SEAL GETTING STUCK UNDER LINER. SECURED LINER SCREWS IAW MM LINER INSTALLATION SYS OPS CK€™S NORMAL REF MM 52-12-01-401. OPENSDR IPXA2024041736479Control Panel · malfunctionedEMERGENCY LIGHTS UNARMED LIGHT DOES NOT EXTINGUISH WHEN ARMED REMOVED AND REPLACED EMERGENCY LIGHT PANEL PER AMM 33-51-08 OPS CHECK GOOD.SDR IPXA2024040618602Floorbeam · corrodedMAIN DECK FLOOR - STA 1720 BETWEEN BL 0 AND RBL 45, 3 NUTPLATES STRAPS WITH CORROSION INSTALLED (3EA) ANGLES AND (3EA) NUTPLATES STRAP I.A.W. SRM 51-40-02-0G.SDR IPXA2024040618589Floorbeam · corrodedMAIN DECK FLOOR - STA 1720 BETWEEN BL 0 AND LBL 45, 4 NUTPLATES STRAPS WITH CORROSION INSTALLED (2EA) NEW ANGLES, (4EA) NUTPLATES STRAP AND (2EA) EXISTING ANGLES I.A.W. SRM 51-40-02-0G.SDR IPXA2024041599046Tee Fitting · corroded*** SUPPLEMENTAL SDR *** FAULT: THE CROSS-FLOOR SUPPORT TIE AT STA 1060 LBL ZERO HAS INITAIL SIGNS OF CORROSION. DOT 39-03 INSTALLED SUPPORT FLOOR P/N 144N5005-5 I.A.W. SRM 51-40-02 FASTENRES USED:MS20426AD3-12 BTCH: 0004238822, BACN10JZ3A2U BATCH:004200335.SDR IPXA2024041594591Tee Fitting · corroded*** SUPPLEMENTAL SDR *** FAULT: WTB STRUCTURE - T-CHORD STA 1220 LH HAS CORROSION APPLIED TOPCOAT NEW T-CHORD I.A.W AMM51-21-15 PAINT CUP. #: 02-012-176.SDR IPXA2024040999046Floorbeam · corrodedMAJOR REPAIR. THE CROSS-FLOOR SUPPORT TIE AT STA 1060 LBL ZERO HAS INITAIL SIGNS OF CORROSION. DOT 39-03 AUDIT COMPLETESDR IPXA2024032894591Tee Fitting · corrodedWTB STRUCTURE - T-CHORD STA 1220 LH HAS CORROSION VERIFIED EVALUATED T-CHORD AT STA 1200 LH, 100% MATERIAL LOST, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-71-1A-1 DETAIL V. AND REMOVED T-CHORD DAMAGED I.A.W. SRM 51-40-02-0G.SDR IPXA2024041084031Frame · dented*** SUPPLEMENTAL SDR *** FAULT: AFT CARGO PIT - FRAME RH SIDE STA 1220 HAS A DENT IN UPPER FLANGE AT STR23R INSTALLED REPAIR SPLICE AT FRAME 1220 RH IAW SRM 51-40-02-0G AND 53-00-07-2R-6.SDR IPXA2024032784031Frame · dentedAFT CARGO PIT - FRAME RH SIDE STA 1220 HAS A DENT IN UPPER FLANGE AT STR23R FRAME STA1220 RH THE DAMAGE FOUND TO BE OUT OF LIMITS I.A.W. SRM 53-00-07-1A-9.SDR IPXA2024041560472Tee Angle · corrodedWTB STRUCTURE - T-CHORD STA 1200 -1240 LH HAS CORROSION INSTALLED NEW T-CHORD I.A.W SRM 51-40-02-0G.SDR IPXA2024041060688Frame · dentedFWD CARGO PIT - FRAME STA 820 LH SIDE HAS A DENT IN UPPER FLANGE BETWEEN STR 24L AND 25L. DOT 101-5 INSP COMPLETE JOB COMPLETE.SDR IPXA2024040860472Tee Fitting · corrodedWTB STRUCTURE - T-CHORD STA 1200 -1240 LH HAS CORROSION VERIFIED CIC.SDR IPXA2024040260754Transition Panel · dentedFWD CARGO PIT - TRANSITION PANEL BETWEEN FS580 TO 600 LH SIDE HAS A DENT. DOT 101-6 VERIFIED: AFTER FURTHER EVALUATION, DENT FOUND TO BE WITHIN LIMITS I.A.W. B757 SRM 53-00-53-1A-1, FIGURE 101 , DETAIL VI. VERIFIED JOB COMPLETE. REVIEWED.SDR IPXA2024032660576Frame · dentedFWD CARGO PIT - FRAME STA 780 RH SIDE HAS A DENT IN UPPER FLANGE BETWEEN STR 23R AND 24R. DOT 101-3 APPROVED.SDR IPXA2024032660754Transition Panel · dentedFWD CARGO PIT - TRANSITION PANEL BETWEEN FS580 TO 600 LH SIDE HAS A DENT. DOT 101-6 VERIFIED: AFTER FURTHER EVALUATION, DENT FOUND TO BE WITHIN LIMITS I.A.W. B757 SRM 53-00-53-1A-1, FIGURE 101 , DETAIL VI. VERIFIED JOB COMPLETE. OPENSDR IPXA2024032660672Frame · dentedFAULT: FWD CARGO PIT - FRAME STA 820 RH SIDE HAS A DENT IN UPPER FLANGE BETWEEN STR 23R AND 24R. DOT 101-4 FRAME STA 820RH, DENT IN UPPER FLANGE IS NOT ALLOWED I.A.W. B757-200 S.R.M. 53-00-07-1A-1 FIG 101. OPENSDR IPXA2024032660588Frame · dentedFWD CARGO PIT - FRAME STA 720 RH SIDE HAS A DENT IN UPPER FLANGE BETWEEN STR 23R AND 24R. DOT 101-1 VERIFIED: TRIMMED OUT DAMAGED AREA I.A.W. B757-200 S.R.M. 51-10-02.<BR>DIMENSIONS CUT OUT L=1.800" W=.900". OPENSDR IPXA2024032660625Frame · dentedFWD CARGO PIT - FRAME STA 760 RH SIDE HAS A DENT IN UPPER FLANGE BETWEEN STR 22R AND 23R.DOT 101-2 REQUEST NDT. OPENSDR IPXA2024041540206Transition Panel · corrodedAFT CARGO PIT - RH SIDE TRANSITION PANEL FROM STA 1200 TO STA 1310 HAS CORROSION AROUND TIE DOWN FITTINGS (STA 1220,1240,1260,1280,1300) DOT 07308-009 INSTALLED DOUBLER AND SIDE PANEL I.A.W B757 SRM 51-40-02-0G.SDR IPXA2024041540194Transition Panel · corroded*** SUPPLEMENTAL SDR *** FAULT: AFT CARGO PIT - RH SIDE TRANSITION PANEL FROM STA 1310 TO STA 1380 HAS CORROSION AROUND TIE DOWN FITTINGS (STA 1320,1340,1360,1380) DOT 07308-007 INSTALLED NEW TRANSITION PANEL I.A.W B757 SRM 51-40-02-0G.SDR IPXA2024041540134Transition Panel · corrodedAFT CARGO PIT - RH SIDE TRANSITION PANEL FROM STA 1440 TO STA 1530 HAS CORROSION AROUND TIE DOWN FITTINGS ( STA 1460,1480,1500,1520) DOT 07308-002 INSTALLED TRANSITION PANEL I.A.W B757 SRM 51-40-02-0G.SDR IPXA2024041140134Transition Panel · corrodedAFT CARGO PIT - RH SIDE TRANSITION PANEL FROM STA 1440 TO STA 1530 HAS CORROSION AROUND TIE DOWN FITTINGS ( STA 1460,1480,1500,1520) DOT 07308-002 VERIFIED: INSTALLED TRANSITION PANEL I.A.W B757 SRM 51-40-02-0G.SDR IPXA2024041040212Frame · dented*MAJOR REPAIR* **SDR FILED OPEN** FAULT: AFT CARGO PIT - FRAME RH SIDE STA 1240 HAS A DENT IN UPPER FLANGE AT STR26R VERIFIED NDT FINDINGS FOR STEP #6 AND STEP #11, NO DEFECTS NOTED AT THIS TIME.SDR IPXA2024041040206Panel · corroded*MAJOR REPAIR* **SDR FILED OPEN** FAULT: AFT CARGO PIT - RH SIDE TRANSITION PANEL FROM STA 1200 TO STA 1310 HAS CORROSION AROUND TIE DOWN FITTINGS (STA 1220,1240,1260,1280,1300) DOT 07308-009 REVIEWED.SDR IPXA2024041040194Panel · corroded*MAJOR REPAIR* **SDR FILED OPEN** FAULT: AFT CARGO PIT - RH SIDE TRANSITION PANEL FROM STA 1310 TO STA 1380 HAS CORROSION AROUND TIE DOWN FITTINGS (STA 1320,1340,1360,1380) DOT 07308-007 REF STEP 16. INSPECTED AND VERIFED TRANSITION PANEL IS INSTALLED. INSP
Back to N451UP