N459UP
Service difficulty reports · 266
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N459UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N459UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2018012625907Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO DECK FLOOR PANEL 232XGF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018012625906Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO DECK FLOOR PANEL 232XFF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018012625904Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO DECK FLOOR PANEL 231XEF DELAMINATED. FABRICATED A NEW FLOOR PANLE IAW SREO B757-5320-9692-K.SDR IPXA2018012625903Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO DECK FLOOR PANEL 222XCF DELAMINATED. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018012625902Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO DECK FLOOR PANEL 222XBF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018012625901Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO DECK FLOOR PANEL 222XAF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018012625900Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO DECK FLOOR PANEL 221XAF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018012625899Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO DECK FLOOR PANEL 221XBF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018012625898Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO DECK FLOOR PANEL 221XCF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017062918745Power Supply · inoperativeEMERGENCY EXIT EXTERNAL EGRESS LIGHT INOPERATIVE. R & R THE POWER SUPPLY M731. SYS CHECKED OK, IAW AMM 33-51-07.SDR IPXA2017050816884Lamp · inoperativeEXTERIOR EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED THE LAMPS IAW AMM 33-51-06-962-001-003.SDR IPXA2016101209293Battery Pack · inoperativeBATTERY PACK WILL NOT STAY ON LONGER THAN ONE MINUTE. R & R THE BATTERY PACK IAW AMM 33-51-07-902-001.SDR IPXA2016101109264Battery Pack · damagedINSPECTION TYPE: MT, EMERGENCY BATTERY PACK WILL NOT STAY ON LONGER THAN ONE MINUTE. R & R THE BATTERY PACK IAW AMM 33-51-07-902-001.SDR IPXA2016021299276Tray · crackedINSPECTION TYPE :C10, EMPENNAGE INTERNAL. APU FIRE BOTTLE SUPPORT TRAY CRACKED AROUND MOUNT FASTENER HOLES. REPLACED APU FIRE BOTTLE SUPPORT TRAY IAW SRM 51-40-02.SDR IPXA2016021099205Support Bracket · crackedINSPECTION TYPE:C10, RT AFT WING TO BODY FAIRING LOWER SUPPORT BRACKET CRACKED. REPLACED PART IAW DWG 149N7665.SDR IPXA2016021099202Support Bracket · crackedINSPECTION TYPE: C10, RT AFT WING TO BODY FAIRING UPPER SURFACE CRACKED. R & R PART IAW BAC DWG 149N7665.SDR IPXA2014031082191Web · puncturedINSPECTION TYPE:C, BELOW VERTICAL STABILIZER L/E PANEL 321CL FOUND PUNCTURED HOLE ON L/E FALSE SPAR WEB. REMOVED SHIELD AT VERTICAL STABILIZER BELOW L/E PANEL 321CL TO GAIN ACCESS IAW SRM 51-40-02. REQUIRE TO REPLACE 2EA RIVNUTS. REMOVED L/E PANEL 321BL FOR FSDR IPXA2014022682039Floor Panel · delaminatedS1C9 INSPECTION, MAIN CARGO DECK FLOOR PANEL 241XAF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO 5320-9692.SDR IPXA2014022682038Floor Panel · delaminatedS1C9 INSPECTION, MAIN CARGO DECK FLOOR PANEL 242XAF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO 5320-9692 FROM A402H-48-144.SDR IPXA2014012081505Window · bindingCAPTAIN'S L2 WINDOW WAS DIFFICULT TO OPEN AND WILL NOT CLOSE. R & R L2 WINDOW IAW AMM 56-11-02-401. VERIFIED OPS CHECK OF WINDOW HEAT AND LEAK CHECKED GOOD. WINDOW HEAT SCREWS TORQUED TO AMM VALUES.SDR IPXA2013122301095Lamp · inoperativeLAMPS BURNED OUT ON VOR NR 2 AUTO-MANUAL SWITCH. REPLACED LAMPS IN FLT. PUSHED SWITCH IN, AND A PUFF OF SMOKE. PULLED SWITCH OUT. PULLED CIRCUIT BREAKER AND LANDED NORMALLY. R & R RIGHT VOR CONTROL PANEL IAW AMM 34-51-02-002-022. OPS CHECKED NORMAL.SDR IPXA3579535Panel · puncturedRT INBD MAIN FLAP COVE PANEL LWR SURFACE 3 DAMAGE AREAS 81" OTBD OF INBD EDGE 3.1" FWD OF AFT EDGE. REPAIRED IAW EO B757-5750-51606-A.SDR IPXA12571778Frame · dentedINSPECTION TYPE:C, FWD CARGO BAY STA 680, S24-25R VERTICAL FLANGE OF FRAME IS DENTED. REPAIRED FRAME IAW SRM 53-00-07-2R, REPAIR 5, DETAIL 3 WITH .063" X 7075-T6 MATERIAL.SDR IPXA12571776Cargo Track · corrodedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT BS 1177-1184, LBL 60 SEAT TRACK INBD FLANGE HAS CORROSION IN 2 LOCATIONS. REPAIRED IAW EA 120124 AND B757-5310-45885-A.SDR IPXA2571717Cargo Track · corrodedINSPECTION TYPE:C, MAIN CARGO TRACK SPLICE BS 879, BL0 HAS CORROSION. FABRICATED NEW CARGO TRACK IAW DWG 143N5405 AND EA 120190.SDR IPXA12571759Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 251XDF IS DAMAGED AT FWD EDGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2571680Frame · dentedINSPECTION TYPE:C-CK, FWD PIT STA 760 STR 24L VERTICAL FLANGE OF FRAME IS DENTED. REPAIRED FRAME IAW SRM 53-00-07-2R, REPAIR 5, DETAIL 2 WITH .063" X 7075-T6 MATERIAL.SDR IPXA2571656Frame · dentedINSPECTION TYPE:C-CK, AFT PIT STA 1340 BETWEEN 25-26R VERTICAL FLANGE OF FRAME IS DENTED. REPAIRED IAW SRM 53-00-07-2R-5, DETAIL 3.SDR IPXA2571655Frame · dentedINSPECTION TYPE:C-CK, AFT PIT STA 1540 BETWEEN 25-26R VERTICAL FLANGE OF FRAME IS DENTED. REPAIRED IAW SRM 53-00-07-2R-5, DETAIL 3.SDR IPXA2571612Frame · dentedINSPECTION TYPE:C-CK, FWD PIT STA 680, BETWEEN 24L-25L VERTICAL FRAME, IS DENTED. REPAIRED IAW SRM 53-00-07-2R-5, DETAIL 3.SDR IPXA2571611Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 231XHK HAS EDGE DAMAGE AND PULLED INSERTS. FABRICATED MAIN CARGO COMPARTMENT FLOOR PANEL 231XHF IAW EO B757-5320- 9692-H.SDR IPXA2571610Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 231XPF HAS EDGE DAMAGE. FABRICATED MAIN CARGO FLOOR PANEL 231XPF IAW EO B757-5320-9692-H.SDR IPXA2571609Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 251XKF HAS EDGE DAMAGE. FABRICATED MAIN CARGO FLOOR PANEL 251XKF IAW EO B757-5320-9692-H.SDR IPXA12571578Seat Track · corrodedINSPECTION TYPE:C-CK, STA 1180+5, RBL 60, SEAT TRACK HAS CORROSION ON INNER FLANGE. REPAIRED IAW EA 120120 AND EO B757-5310-45881-A.SDR IPXA12571577Seat Track · corrodedINSPECTION TYPE:C-CK, STA 1200, RBL 60, SEAT TRACK HAS CORROSION ON INNER FLANGE. REPAIRED IAW EA NR 120119.SDR IPXA12571576Sill · corrodedINSPECTION TYPE:C-CK, MAIN CARGO DOOR SILL WEB STA 560, LBL 60, WL 208 HAS CORROSION AT SCREW HOLE. REPAIRED IAW EA 120113 AND EO B757-5310-45870-A.SDR IPXA12571753Frame · crackedINSPECTION TYPE:C-CK, MAIN CARGO BS 520 FRAME IS BENT AND CRACKED JUST BELOW STRINER 16R. INSTALLED FRAME REPAIR IAW EA 120160 IR AND EO B757-5310-45965-A.SDR IPXA12571555Floor Panel · damagedINSPECTION TYPE:C-CK, FLOOR PANEL 212XAF HAS PUNCTURES AND EDGE DAMAGE. FABRICATED NEW FLOOR PANEL 212XAF IAW EO B757-5320-9692-H.SDR IPXA12571415Frame · dentedINSPECTION TYPE:C-CK FWD PIT STA 800 STR 24L VERTICAL FRAME IS DENTED. REMOVED DAMAGE FROM FWD PIT STA 800, STR 24L VERTICAL FRAME, FABRICATED AND INSTALLED REPAIR DOUBLER IAW SRM 53-00-972R, DETAIL 1.SDR IPXA12571541Floor Panel · damagedINSPECTION TYPE:C-CK FLOOR PANEL NR 221XCF HAS DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12571747Shear Tie · corrodedINSPECTION TYPE:C-CK, AFT CARGO PIT BS 1300 S27R, RBL 21 HAS CORROSION ON NUTPLATE CHANNEL AND SHEAR TIE. FABRICATED AND REPLACED SHEAR TIE AND NUTPLATE STRIP IAW DWG 146N1096 AND SRM 51-40-02.SDR IPXA2571698Dome Nut · corrodedINSPECTION TYPE: C, BAD DOME NUT AT PANEL 197NL AT BS 1300 S27R, RBL 21 AFT CARGO AREA. FABRICATED NEW NUTPLATE STRIP FOR PANEL 197NL AT STA 1300 S-27R, RBL 2 1 IAW GMM 09-10 AND DWG 140N2009.SDR IPXA12571366Floorboard · wornINSPECTION TYPE:C-CK, MAIN CARGO FLOORBOARD 232XGF IS WORN FROM BALL MAT. FABRICATED MAIN CARGO FLOORBOARD 232XGF IAW EO B757-5320-9692-H.SDR IPXA12571365Floorboard · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOORBOARD 221XBF HAS DAMAGE. FABRICATED MAIN CARGO FLOORBOARD 221XBF IAW EO B757-5320-9692-H.SDR IPXA12571361Floorboard · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOORBOARD 232XHF IS WORN FROM BALLMAT. FABRICATED MAIN CARGO FLOORBOARD 232XHF IAW EO B757-5320-9692-H.SDR IPXA12571349Floor Panel · wornINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 232XEF IS WORN FROM BALL MAT. FABRICATED MAIN CARGO FLOOR PANEL 232XEF IAW EO B757-5320-9692-H.SDR IPXA12571338Floorboard · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO FLOORBOARD 232XDF IS DELAMINATED. FABRICATED MAIN CARGO FLOORBOARD 232XDF IAW EO B757-5320-9692-H.SDR IPXA2571329Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 221XAF HAS EDGE DAMAGE. FABRICATED MAIN CARGO FLOOR PANEL 221XAF IAW EO B757-5320-9692-H.SDR IPXA2571328Floorboard · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOORBOARD 231XGF IS WORN FROM BALL MAT. FABRICATED MAIN CARGO FLOORBOARD 231XGF IAW EO B757-5320-9692-H.SDR IPXA2571327Floor Panel · wornINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 231XDF IS WORN FROM BALL MAT. FABRICATED MAIN CARGO FLOOR PANEL 231XDF IAW EO B757-5320-9692-H.