duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N462UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N462UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2019011938034Floor Panel · damagedINSPECTION TYPE:SEG3 MAIN CABIN FLOOR PANEL 222XBF REQUIRES FAB (DAMAGED). FABBED PANEL 222XBF FROM 5024N400001SS-G BATCH#3350658 PER SREO B757-5320-9692-K.SDR IPXA2019011838007Floor Panel · damagedINSPECTION TYPE:SEG4 MAIN CABIN FLOOR PANEL 251XKF REQUIRES FAB. FABBED PANEL 251XKF FROM 5024N400001SS-G BATCH# 3350658 PER SREO B757-5320-9692-K.SDR IPXA2019020658716Floor Panel · damagedINSPECTION TYPE:CP11MAIN CABIN FLOOR PANEL 231XCF REQUIRES FABFABBED PANEL 231XCF FROM 50024N400001SS-G, BATCH # 3350658 AND STEP CUT PER SREO B757-5320-9692-KSDR IPXA2019020658703Floor Panel · damagedINSPECTION TYPE:C1MAIN CABIN FLOOR PANEL 231XFF REQUIRES FABFABBED PANEL 231XFF FROM 5024N40001SS-G, BATCH # 3350658 AND STEP CUT PER SREO B757-5320-9692-KSDR IPXA2019020658702Floor Panel · damagedINSPECTION TYPE:C1MAIN CABIN FLOOR PANEL 231XJF REQUIRES FABFABBED PANEL 231XJF FROM 5502N4000014SS-G, BATCH # 3350658 AND STEP CUT PER SREO B757-5320-9692-LSDR IPXA2018070631418Mount · brokenF/O'S EVAS MOUNT HAS BROKEN FROM A/C. REINSTALLED MOUNT FOR FO'S EVAS REF EO B757-2560-45127-H.SDR IPXA2017121224473Engine · failedINSPECTION TYPE:N/ALEFT ENGINE FAILURE ENROUTE FL200 PERFORMED ENGINE FAILURE/SHUTDOWN CHECK LIST ENGINE WAS WITHIN PARAMETERS FOR INFLIGHT START. STARTED NORMALLY AND OPERATED NORMALLY FOR REMAINDER OF FLIGHT.PER FIM 710-05-00-815-806 T/S PER AMM 73-11-10 CHESDR IPXA2017082320885O-Ring · leakingEMERGENCY DECLARED, THE LEFT HYDRAULIC RESEVOIR QTY LOW. FOUND A HYD LEAK ON FLAP STALL DEPRESSURIZATION MODULE ASSY CONNECTOR. R & R THE O-RING IAW AMM 20-10-19-404-001. SERVICED THE LT HYD SYS IAW AMM 12-12-01-301. LEAK CHECKED GOOD. NO LEAKS NOTED IAW AMSDR IPXA2017041015979Transceiver · inoperativeTRANSMISSION ON BOTH HF SYSTEMS, FOR ALL STATIONS. R & R LT HF TRANSCEIVER IAW MM 23-11-03. OPS NMLSDR IPXA2017031415123Smoke Goggles · crackedSMOKE GOGGLES CRACKED. REPLACED THE SMOKE GOGGLES IAW AMM TASK 25-64-00-202-021.SDR IPXA2017011912964Skin · corrodedINSPECTION TYPE: C10, LOWER FORWARD VHF ANTENNA HAS AREAS OF CORROSION ON AIRCRAFT SKIN. REMOVED CORROSION IAW SRM 53-00-01, FOUND TO BE WITHIN LIMITS IAW SRM 53-00-01. ALODINED REWORKED AREA IAW AMM 51-21-04.SDR IPXA2017020613744Skin · dentedINSPECTION TYPE: SEG2, RT HORIZONTAL STAB UPPER SKIN SURFACE LEADING EDGE PLANK FROM AUX SPAR TO FRONT SPAR FROM FUSELAGE TO STAB TIP HAS NUMEROUS DENTS. REPAIRED IAW SRM 51-70-10, REPAIR 2, FIG 201, 51-70-10.SDR IPXA2017011912963Support · corrodedINSPECTION TYPE: C10, WING TO BODY SUPPORT AT BS 840 HAS CORROSION. REMOVED CORROSION IAW SRM 53-00-71, FOUND TO BE WITHIN LIMITS IAW SRM 53-00-71. ALODINE, PRIMED AND TOP COATED REWORKED AREA.SDR IPXA2017011912962Support · corrodedINSPECTION TYPE: C10, RIGHT FWD WING TO BODY PANEL SUPPORT STRUCTURE IS CORRODED IN SEVERAL PLACES OVER UPPER AND LOWER SIDE AT BS 800, RBL 4 TO 23. REMOVED CORROSION IAW SRM 53-00-71. FOUND TO BE WITHIN LIMITS IAW SRM 53-00-01. ALODINED, PRIMED, AND TOP SDR IPXA2017011912961Attach Angle · corrodedINSPECTION TYPE: C10, RIGHT FWD WING TO BODY PANEL SUPPORT STRUCTURE ATTACH ANGLE IS CORRODED AT BS 700, RBL 15. REMOVED CORROSION IAW SRM 53-00-71, FOUND TO BE WITHIN LIMITS IAW SRM 53-00-71, ALODINED, PRIMED, AND TOP COATED REWORK AREA.SDR IPXA2015030786756Bulkhead Web · noneINSPECTION TYPE:C, D507181 NOSE WHEEL WELL BULKHEAD WEB REPAIR STA 395. REMOVED DOUBLER REPAIR ON D507181 NOSE WHEEL WELL BULKHEAD STA .395 IAW SRM 51-40-02-0G. NDT FOR CRACKS. HFEC IAW NTM 51-00-19, NO NOTED DEFECTS T12117. NDT ROTO PROBE OPEN HOLES. ROSDR IPXA2015021786006Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XBF DELAMINATED. REMOVED FLOOR PANEL 231XBF MCD IAW AMM 53-01-01-024-022. 2. FABRIATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2015021986108Floor Panel · crackedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 242XDF CRACKED AT EDGE. FABBED PANEL 242XDF PN 144N5361-11 FROM A402H-48X144, BAT 2664589 IAW SREO 5320-9692-H.SDR IPXA2015021986106Floor Panel · puncturedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 242XCF DENTED AND PUNCTURED. 53-37 FABBED PANEL 242XCF, PN 144N5361-54 FROM A402H-48X144, BAT 2664589 IAW SREO B757-5320-9692-H.SDR IPXA2015030286605Bulkhead · crackedINSPECTION TYPE:CD 507179: FUSELAGE BULKHEAD PRESSURE PAN REPAIR AT STA 395. REMOVED E AND E COOLING SUPPLY DUCT IAW 21-20-01. REMOVED P3I PANEL TO FOM IAW AMM 24-51-02-024-001. REMOVED 1 EA BRACKET TO FOM IAW SRM 51-40-02. REMOVED BULKHEAD PRESSURE PAN IASDR IPXA2015010585204Flap System · warning messageT/E FLAP DISAGREE WHEN FLAPS SELECTED TO 25 FROM 20 POSITION. EMERGENCY DECLARED. NR 1 FSEU FAULT HISTORY SHOWS FLAP FAIL WITH 217. COMPLIED WITH FIM 27.51.00.815.810 FIG 107 TO BLOCK 27. NO FAULTS. R & R NR 1 FSEU AS A PRECAUTION AMM 27.51.01. OPS NORMSDR IPXA2014041482643Skin · damagedLEFT FUSELAGE SKIN DAMAGED AT BS 600-620 BETWEEN S21-25L. INSTALLED SKIN REPAIR AT BS 594-625 S20-26L.SDR IPXA2014041482642Skin · damagedLEFT EXTERIOR FUSELAGE SKIN DAMAGED AT BS 700, BETWEEN S20-23L. INSTALLED SKIN REPAIR AT BS 690-710.SDR IPXA2014041482640Stringer · damagedFWD CARGO STRINGER 23L DAMAGED BS 600. INSTALLED STRINGER REPAIR.SDR IPXA2014041482639Stringer · damagedFWD CARGO STRINGER 24L DAMAGED AT BS 600. INSTALLED STRINGER REPAIR.SDR IPXA2014041482638Stringer · damagedFWD CARGO STRINGER 21L DAMAGED BS 680 - 720. R & R STRINGER SECTION BS 660 - 730, SPLICE REPAIR.SDR IPXA2014041482636Stringer · damagedFWD CARGO STRINGER 21L DAMAGED BS 600 - 620. R & R STRINGER FROM BS 570 - 660 AND SPLICE REPAIR.SDR IPXA2014041482635Stringer · damagedFWD CARGO STRINGER 22L DAMAGED BS 680 - 700. R & R STRINGER FROM BS 660 - 730 AND SPLICE REPAIR.SDR IPXA2014041482634Stringer · damagedFWD CARGO STRINGER 22L DAMAGED AT BS 600 -620. R & R STRINGER SECTION FROM BS 570 - 660 AND SPLICE REPAIR.SDR IPXA2014012981674Altimeter · inoperativeFIRST OFFICER`S ALTIMETER HAS OFF FLAG IN VIEW IN FLIGHT WITH AIR DATA IN NORMAL AND ALTERNATE PULLED AND RESET C/B NO HELP IAW FIM. R & R ALTIMETER IAW AMM 34-10-02, ITEM 90.SDR IPXA3577421Floorboard · damagedINSPECTION TYPE:S4C8, FLOORBOARD 231XCF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577365Floor Panel · damagedINSPECTION TYPE:S4C8, CABIN FLOOR PANEL 242XLF HAS EDGE DAMAGE, FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577364Floor Panel · puncturedINSPECTION TYPE:S4C8, CABIN FLOOR PANEL 252XHF HAS PUNCTURES. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577363Floor Panel · damagedINSPECTION TYPE:S4C8, LAVATORY AREA FLOOR PANEL 212XAF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577362Floor Panel · damagedINSPECTION TYPE:S4C8, COURIER AREA FLOOR PANEL 211XAF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3577448Floor Panel · damagedINSPECTION TYPE:S4C8, CABIN FLOOR PANEL 231XMF HAS UNDER SURFACE WITH DAMAGE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3577420Floorboard · damagedINSPECTION TYPE:S4C8, FLOORBOARD 251XQF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3577419Floorboard · damagedINSPECTION TYPE:S4C8 SOT 47-062, FLOORBOARD 251XRF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3577418Floorboard · damagedINSPECTION TYPE:S4C8, FLOORBOARD 252XUF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3577417Floor Panel · damagedINSPECTION TYPE:S4C8, UPPER CARGO FLOORBOARD 251XMF HAS TORN OUT INSERTS DOT 13/042. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577390Floor Panel · damagedINSPECTION TYPE:S4C8, MAIN DECK FLOOR PANEL 232XPF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577389Floor Panel · damagedINSPECTION TYPE:S4C8, MAIN DECK FLOOR PANEL 232XVF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA13577387Floor Panel · damagedINSPECTION TYPE:S4C8, MAIN DECK FLOOR PANEL 231XSF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA13577386Floorboard · damagedINSPECTION TYPE:S4C8, FLOORBOARD 252XSF IS DAMAGED FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13577385Floorboard · damagedINSPECTION TYPE:S4C8, FLOORBOARD 252XRF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13577384Floorboard · damagedINSPECTION TYPE:S4C8, FLOORBOARD 252XTF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13577383Floorboard · damagedINSPECTION TYPE:S4C8, FLOORBOARD 252XPF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13577382Floorboard · damagedINSPECTION TYPE:S4C8, FLOORBOARD 252XQF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13577381Floor Panel · damagedINSPECTION TYPE:S4C8, MAIN DECK FLOOR PANEL 231XUF HAS EDGE DAMAGE 53-62. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA13577380Floor Panel · damagedINSPECTION TYPE:S4C8, MAIN DECK FLOOR PANEL HAS 231XHF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.