N467UP
Service difficulty reports · 156
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N467UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N467UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2019040140625Floor Panel · delaminatedINSPECTION TYPE:SEG3MCD FLOOR PANEL 222XAF IS DELAMINATEDFABRICATED PNL 221XAF FROM 5024N400001SS-G, BATCH # 3441868 PER SREO B757-5320-9692-KSDR IPXA2019040140623Floor Panel · delaminatedINSPECTION TYPE:SEG3MCD FLOOR PANEL 221XCF IS DELAMINATEDFABRICATED PNL 221XF FROM 5024N400001SS-G, BATCH # 3441868 PER SREO B757-5320-9692-KSDR IPXA2019040140622Floor Panel · delaminatedINSPECTION TYPE:SEG3MCD FLOOR PANEL 221XBF IS DELAMINATEDFABRICATED PNL 221XBF FROM 5024N400001SS-G, BATCH # 3341868 PER SREO B757-5320-9692-KSDR IPXA2019040140621Floor Panel · delaminatedINSPECTION TYPE:SEG3MCD FLOOR PANEL 221XAF IS DELAMINATEDFABRICATED PNL 221XAF FROM 5024N400001SS-G, BATCH # 3441868 PER SREO B757-5320-9692-KSDR IPXA2019011737957Flap · lockedINSPECTION TYPE:N/A TE FLAP DISAGREE ON APPROACH. THE CREW DECLARED AN EMERGENCY AND LANDED UNEVENTFULLY. PERFORMED FIM 27-51-00-815-808 PER TECH SUPPORT AES DAA LAP HANDLE WAS AT 17DEGREES. PER BLOCK ONE THIS CONDITION WILL LOCK OUT FLAPS/SLATS. RESET SYSTEM SDR IPXA2018110935827Life Vest · missingPILOT`S LIFE VEST MISSING. REPLACED THE LIFE VEST IAW AMM 25-60-00.SDR IPXA2017121824624Container · damagedBOTH EMERGENCY ESCAPE HARNESS POUCHES ARE FALLING APPART. INSTALLED BOTH HARNESS POUCHES IAW DRAWING 232N4030-3 REV -B.SDR IPXA2017040315782Floor Panel · delaminatedINSPECTION TYPE: SEG2, MAIN DECK FLOOR PANEL 231XJF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO 757-5320-9692-J.SDR IPXA2017040315781Floor Panel · delaminatedINSPECTION TYPE: SEG2, MAIN DECK FLOOR PANEL 231XFF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO 757-5320-9692-J.SDR IPXA2017040115724Skin · dentedINSPECTION TYPE: SEG2, LEFT OTBD AFT FLAP LOWER SKIN DENTED. REPAIRED THE SKIN IAW SRM 51-70-04-06, PARA 4.E, 4.F, AND 4.G.SDR IPXA2015041688148Floor Panel · damagedINSPECTION TYPE:C, MECHANIC REQUEST MAIN DECK FLOOR PANEL 242XAF, PN144N5361-40 HAS EDGE DAMAGE.1. FABRICATED THE FLOOR PANEL IAW SREO.SDR IPXA2015041688149Floor Panel · misrepairedINSPECTION TYPE:C, MAINTENANCE REQUEST MAIN DECK FLOOR PANEL 241XCF, PN 144N5361-36 UPPER SURFACE HAS AN IMPROPER REPAIR. FABRICATED THE FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015030586669Window · crackedDURING CRUISE AT FL 340, F/O FORWARD WINDOW CRACKED NO AIR LEAK NOTED. R & R F/O'S FWD WINDOW IAW MM 56-11-01-424. OPS CHECK GOOD FOR TERMINAL INSTALLATION, SEE LOG BOOK PAGE 785757, ITEM 1 EFF REF: 56-11-01-05-15R.SDR IPXA2014122285100Transmission · inoperativeDURING APPROACH, SLECTED FLAPS 30, A T/E DISAGREE EICAS MESSAGE ILLUMINATED, DECLARED AN EMERGENCY AND RAN THE T/E DISAGREE ALT CHECKLIST. POSITIONED FLAP 30 WITH ALTERNATE FLAP SELECTOR. HAD MOMENTARY FLAP LOAD RELIEF MESSAGE. R & R OF LEFT INBD, OTBD FLASDR IPXA2014120885015Transmission · failedEMERGENCY DECLARED. T/E FLAP DISAGREE BETWEEN 15 AND 20. FOUND LT INBD FLAP TRANSMISSION INDICATOR POPPED 1881270. REMOVED LT INBD FLAP TRANSMISSION, IAW AMM 27-51-06. GVI ACCOMPLISHED, NO FINDINGS . NSTALLED LT INBD FLAP TRANSMISSION UP TO STEP F, AMM 27-SDR IPXA2014120885013Transmission · failedT/E FLAP DISAGREE BETWEEN 15 AND 20 DEGREES. EMERGENCY DECLARED. FOUND LT & RT INBD FLAP TRANSMISSIONS LOW AND OVERLOAD INDICATORS TRIPPED. RESET TRIPPED INDICATORS. OUND LT INBD FLAP TRANSMISSION INDICATOR TRIPPED. R & R LT INBD FLAP TRANSMISSION AMM 27-SDR IPXA2014101584604Pitot Tube · contaminatedELEVATOR FEEL STATUS MESSAGE DURING CLIMBOUT. FOUND NR 1 AUX PROBE CONTAMINATED WITH ORGANIC FOD. BLEW OUT PITOT PROBE AND LEAK CHECK LINE GOOD. PERFORMED ELEVATOR FEEL COMPUTER STATIC SYSTEM TEST IAW MM 34-11-00-735-176.SDR IPXA13578131Floor Panel · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 211XAF HAS DAMAGE BOTTOM SURFACE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3578106Floor Panel · puncturedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 251XNF HAS PUNCTURES. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3578105Floor Panel · puncturedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 252XPF DAMAGED BOTTOM SURFACE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3578100Floor Panel · puncturedINSPECTION TYPE:C-8, MAIN CARGO FLOOR PANEL 252XQF HAS A PUNCTURED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692.SDR IPXA3578063Stiffener · corrodedINSPECTION TYPE:C-8, APU COMPARTMENT FWD BULKHEAD HAS A CORRODED STIFFENER JUST BELOW LIGHT SWITCH. REMOVED, FABRICATED AND INSTALLED NEW STIFFENER.SDR IPXA3578058Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 242XCF, HAS A HOLE PUNCTURE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578057Floorboard · damagedINSPECTION TYPE:C-8, MAIN CARGO FLOORBOARD DELAMINATED, 241XHF FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578056Floor Panel · damagedINSPECTION TYPE:C-8, MAIN CARGO FLOOR PANEL 232XWF, HAS A TORN & DELAMINATED CORNER. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3578055Floor Panel · damagedINSPECTION TYPE:C-8, MAIN CARGO FLOOR PANEL 232XXF, HAS A TORN CORNER AT INSERT LOCATION. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3578029Floor Panel · damagedINSPECTION TYPE:C-8 MAIN CARGO FLOOR PANEL 252XKF DELAMINATED, FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3578028Floor Panel · damagedINSPECTION TYPE:C-8, MAIN CARGO FLOOR PANEL 242XKF, HAS EDGE DELAMINATION FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3578059Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 232XYF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578054Floor Panel · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 231XEF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3578092Web · corrodedINSPECTION TYPE:C-8, FUSELAGE UPPER LOBE INTERIOR HAS CORROSION ON FLOOR WEB AT BS 324.8 LBL 28-48. REPAIRED IAW SRM 53-10-51-2R-2.SDR IPXA13577972Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 222XAF HAS DAMAGE ON BOTTOM SURFACE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577962Floorboard · damagedINSPECTION TYPE:C-8 MAIN CABIN FLOORBOARD 231XWF HAS DAMAGE ON FWD EDGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577961Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 221XCF HAS DAMAGE ON BOTTOM SURFACE FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577960Floor Panel · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 222XBF HAS DAMAGE ON BOTTOM SIDE FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577959Floorboard · damagedINSPECTION TYPE:C-8 MAIN CABIN FLOORBOARD 222 XAF HAS DAMAGE ON BOTTOM SURFACE FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577958Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 222XCF HAD DAMAGE ON BOTTOM SURFACE FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577974Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 242XHF EDGE BROKEN. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577944Floorboard · brokenINSPECTION TYPE:C-8, MAIN CABIN, FLOORBOARD 251XCF IS BROKEN. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577943Floorboard · dentedINSPECTION TYPE:C-8 MAIN CABIN, FLOORBOARD 251XGF IS DENTED ON FWD SIDE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577942Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 242XMF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577938Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 242XFF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577932Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 242XLF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577931Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 241XJF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577930Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 242XJF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577929Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 242XEF HAS EDGE DAMAGE. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3577904Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 231XJF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3577903Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 241XAF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3577902Floorboard · brokenINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 241XBF HAS BROKEN CORNER. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3577901Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 241XEF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757 5320 9692H.
Back to N467UP