What was found
ELEVATOR FEEL STATUS MESSAGE DURING CLIMBOUT. FOUND NR 1 AUX PROBE CONTAMINATED WITH ORGANIC FOD. BLEW OUT PITOT PROBE AND LEAK CHECK LINE GOOD. PERFORMED ELEVATOR FEEL COMPUTER STATIC SYSTEM TEST IAW MM 34-11-00-735-176.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ELEVATOR FEEL STATUS MESSAGE DURING CLIMBOUT. FOUND NR 1 AUX PROBE CONTAMINATED WITH ORGANIC FOD. BLEW OUT PITOT PROBE AND LEAK CHECK LINE GOOD. PERFORMED ELEVATOR FEEL COMPUTER STATIC SYSTEM TEST IAW MM 34-11-00-735-176.