N468UP
Service difficulty reports · 157
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N468UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N468UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2019072244713Floor Panel · delaminatedINSPECTION TYPE:SEG3 MCD FLOOR PANEL 231XGF IS DELAMINATED. FABRICATED NEW FLOOR PANEL FROM 5024N40000ISS-G BATCH #3489461 PER SREO B757-5320-9692-K.SDR IPXA2019072244712Floor Panel · delaminatedINSPECTION TYPE:SEG3 MCD FLOOR PANEL 231XEF IS DELAMINATED. FABRICATED NEW FLOOR PANEL FROM 5024N40000ISS-G BATCH #3489461 PER SREO B757-5320-9692-K.SDR IPXA2019072244711Floor Panel · delaminatedINSPECTION TYPE:SEG3 MCD FLOOR PANEL 231XDF IS DELAMINATED. FABRICATED NEW FLOOR PANEL FROM 5024N40000ISS-G BATCH #3489461 PER SREO B757-5320-9692K.SDR IPXA2019072244709Floor Panel · delaminatedINSPECTION TYPE:SEG3 MCD FLOOR PANEL 231XBF IS DELAMINATED. FABRICATED NEW FLOOR PANEL FROM 5024N40000ISS-G BATCH #3489461 PER SREO B757-5320-9692-K.SDR IPXA2019072244708Floor Panel · delaminatedINSPECTION TYPE:SEG3 MCD FLOOR PANEL 231XAF IS DELAMINATED. FABRICATED NEW FLOOR PANEL FROM 5024N40000ISS-G BATCH #3489461 PER SREO B757-5320-9692-K.SDR IPXA2019072244707Floor Panel · delaminatedINSPECTION TYPE:SEG3 MCD FLOOR PANEL 221XCF IS DELAMINATED. FABRICATED NEW FLOOR PANEL FROM 5024N40000ISS-G BATCH #3489461 PER SREO B757-5320-9692-K.SDR IPXA2019072244703Floor Panel · delaminatedINSPECTION TYPE:SEG3 MCD FLOOR PANEL 221XBF IS DELAMINATED. FABRICATED NEW FLOOR PANEL FROM 5024N40000ISS-G BATCH #3489461 PER SREO B757-5320-9692-K.SDR IPXA2019072244702Floor Panel · delaminatedINSPECTION TYPE:SEG3 MCD FLOOR PANEL 221XAF IS DELAMINATED. FABRICATED NEW FLOOR PANEL FROM 5024N40000ISS-G BATCH #3489461 PER SREO B757-5320-9692-K.SDR IPXA2018092874470Uplock Sensor · out of adjustAFTER TAKEOFF WITH GEAR HANDLE UP, A GEAR DISAGREE EICAS AND GEAR AMBER LIGHT ILLUMINATED. RAN QRH AT 12,000. ALL LIGHTS WENT OUT. DIVERTED. ACCOMPLISHED A BITE CHECK OF PSEU IAW MM 32-09-04-404-009, SHOWS FAULTS 239, 069. ADJUSTED THE RT GEAR UPLOCK SENSDR IPXA2018032427777Lamp · inoperativeEMERGENCY LIGHT BELOW & AFT OF THE L1 DOOR WAS INOPERATIVE DURING A CHECK. R & R THE LAMP IAW AMM 33-51-06-962-001-003. OPS CHECKED GOOD. OK FOR SERVICE.SDR IPXA2018021226466Panel · damagedPILOT SIDE EMERGENCY ESCAPE ROPE PANEL HAS A BROKEN ANGLE. R & R THE PANEL IAW AMM 25-61-00-424-005.SDR IPXA2017071319248Bushing · corrodedINSPECTION TYPE: SEG2, NR 2 PYLON TWO UPPER LINK BUSHINGS AT THE FWD END CORRODED. REMOVED AND REPLACED.SDR IPXA2017071819464Floor Panel · puncturedINSPECTION TYPE:SEG4, MAIN DECK FLOOR PANEL 242XFF IS PUNCTURED AT TWO SPOTS. FABRICATED NEW FLOOR PANEL 252XFF PER SREO B757-5320-9692-K COMPLETED SERVICE DIFFICULTY REPORT SDR FORM 52-19-051 PER GMM 03.16.01.01.SDR IPXA2017072419708Intercostal · corrodedINSPECTION TYPE: SEG4, LT WING TO BODY FAIRING STRUCTURE BS 900 LBL 31 INTERCOSTAL HAS CORROSION. REPAIRED DAMAGED IAW SRM 51-70-12.SDR IPXA2017071919497Floor Panel · puncturedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL IS PUNCTURED ON BOTTOM SIDE. FABBED PNL 231XFF FROM A402H-48X144 BAT 3119029 PER SREO B757-5320-9692-K.SDR IPXA2017071919496Floor Panel · puncturedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XJF IS PUNCTURED ON BOTTOM SIDE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017071919495Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XDF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017071919494Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XGF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017071819466Floor Panel · damagedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 242XDF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017071819465Floor Panel · puncturedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 242XHF IS PUNCTURED ON UPPER SURFACE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017071819463Floor Panel · delaminatedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 241XHF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017041216080Engine · vibrationATB - TOP OF CLIMB NOTICED RIGHT ENGINE VIBRATION METER WAS 2.5 (UNUSUALLY HIGH) SEVERAL MINUTES LATER PEAKED 2.7 AND TURNED AMBER. RAN QRH PROCEDURE NO HELP. AFTER THREE POWER REDUCTIONS AND CONTINUED AMBER VIB INDICATION CONTACTED FLIGHT CONTROL DUE TO HISTOSDR IPXA2016060904411Sensor · inoperativeAFTER ROTATION TAT CLIMBING TO 57C. R & R TAT PROBE IAW AMM 34-12-012. T/S IAW FIM 32-09-03,-815-804, BLS 7 AND 15 FOUND CODE 058 DURING FSEU BITE. R & R NOSE GEAR NOT COMPRESSED SENSOR S10068. ALT GROUND OPS TEST COMPLETED OK.SDR IPXA2016060604251Light · malfunctionedINSPECTION TYPE:ASE, EMERGENCY EXIT LIGHT AT FWD ENTRY DOOR STAYS ON WITH POWER OFF OPS CHECKED EMERGENCY LIGHT IAW MM 33-51-00-715-227. OPS TEST NORMAL.SDR IPXA2016010997571Rivnut · damagedF/O'S EVAS MOUNTING BRACKET DETACHED FROM STOWAGE COMPARTMENT. RIVNUTS PULLED THROUGH FLOOR OF COMPARTMENT. RE-INSTALLED F/O'S EVAS MOUNTING BRACKET IAW EO B757-2560-45127-H APPROXIMATELY E STEPS 7 & 8.SDR IPXA2015072291422Strap · corrodedINSPECTION TYPE:C, APU INLET STRAP,CORRODED.SDR IPXA2015072291421Angle · corrodedINSPECTION TYPE:C, APU INLET ANGLE CORRODED.SDR IPXA2015072291420Angle · corrodedINSPECTION TYPE:C, APU INLET ANGLE CORRODED.SDR IPXA2015072191373Stiffener · corrodedINSPECTION TYPE:C, UPON REMOVAL OF LT OTBD WING UPPER T/E PANEL, INBD THE SUPPORTING STIFFENER, PN:113N1183-1, FOUND EXFOILATED BETWEEN STA 705.27-735.23. R & R LT OTBD WING UPPER LT OTBD WING UPPER T/E PANEL, INBD SUPPORTING STIFFENER, PN:113N1183-1 AT WS 70SDR IPXA2015072191372Stiffener · corrodedINSPECTION TYPE:C, UPON REMOVAL OF LT OTBD WING, UPPER T/E PANEL OTBD. THE SUPPORTING STIFFENER ASSY, PN:113N1184-1, FOUND EXFOLIATED BETWEEN WS 735.23-775.45. FABRICATED NEW STIFFENER, PN:113N1184-3 ON VT MAE TRAV T15/1149433 IAW DWG 113N1640.SDR IPXA2015071491142Access Panel · corrodedINSPECTION TYPE:C, ACCESS PANEL 542BB AREA BETWEEN MILL STEP AND SEAL CORRODED. CLEANED THE ACCESS PANEL AND FOUND IT TO BE OUT OF LIMITS IAW SRM 57-20-01-2R-5, DETAIL I, FIG 201 SHEET 2 AND NOTE B, REPLACEDTHE ACCESS PANEL.SDR IPXA2015071491132Access Panel · corrodedINSPECTION TYPE: C, ACCESS PANEL 543CB, BETWEEN SEAL AND MILL STOP AREA CORRODED. ACCESS PANEL REPLACED DUE TO SRM 57-20-01-2R-5, DETAIL I, FIG 201.SDR IPXA2015072291415Strap · corrodedINSPECTION TYPE:C, APU INLET MIDDLE STRAP CORRODED. REPAIR OF THE MIDDLE STRAP COMPLETED IAW SRM 53-80-15-2R, R1 DETAIL REV 93.00, THE REPAIR IS CLASSIFIED AS A MAJOR REPAIR.SDR IPXA2015071491170Floor Panel · puncturedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XCF IS PUNCTURED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015071491157Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XAF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015071491156Floor Panel · brokenINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XKF IS BROKEN. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2015071491155Floor Panel · delaminatedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 241XGF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2015071491145Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XMF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2015071491143Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XJF HAS EDGE DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2015072191371Skin · corrodedINSPECTION TYPE: C, NR 2 PYLON LT SIDE SKIN, EXTERNAL BELOW PANEL 443GL HAS CORROSION. REMOVED CORROSION IAW SRM 51-10-02-0G, CHECKED LIMITS AND FOUND CORROSION TO BE OUT OF LIMITS IAW SRM 54-50-01-1A-1, DETAIL III. REPAIRED AREA IAW EA 757-5451-27-A2181 ANDSDR IPXA2015071491131Skin · damagedINSPECTION TYPE:C, FUSELAGE SKIN, BS207 BETWEEN S-14R AND S-15R LIGHTNING STRIKE. REPAIRED LIGHTNING STRIKE AT FUSELAGE SKIN BS207 BETWEEN S-14R AND S-15R IAW SRM 53-00-01-2R-6 SECTION I, PARAGRAPHS 1, 2, AND 3 INSTALLED REPAIR FASTENER.SDR IPXA2015050488635Smoke Goggles · damagedSMOKE GOGGLES CRACKED AT SUPER NUMERARY POSITION. R & R SUPER NUMERARY POSITION SMOKE GOGGLES AS REQUIRED.SDR IPXA2015011685315Warning Message · false activationAFTER DEPARTURE, GEAR LEVER IN UP POSITION RECEIVED GEAR DISAGREE EICAS WITH GEAR WARNING ACCOMPLISHED FIM 32-30-00-815, BLOCKS 1,11,22. NO GEAR DISAGREE CONDITION OCCURED AT GEAR SWING, SYS OPS CHECKED NORMAL.SDR IPXA2013122701148Sliding Window · out of adjustCAPTAIN SLIDING WINDOW BINDS BADLY AFTER PRESSURIZED. PERFORMED LEFT SIDE NR 2 SLIDING WINDOW ADJUSTMENT W/REF TO MM 56-11-02-825-001. OPS CHECK GOOD. ACFT OK FOR FLIGHT.SDR IPXA3579557Floor Support · corrodedINSPECTION TYPE:C-8, AFT CARGO FLOOR SUPPORT HAS CORROSION AT BS 1470, RBL 16. R & R FLOOR SUPPORT IAW DWG 146N5447 AND SRM 51-40-02.SDR IPXA3579519Floor Panel · brokenINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 242XMF BROKEN. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692, APPENDIX B.SDR IPXA3579539Seat Track · corrodedINSPECTION TYPE:C-8, MAIN CABIN SEAT TRACK AT BS 590, LBL 1 HAS CORROSION ON UPPER SURFACE. FABRICATED AND INSTALLED SEAT TRACK SPLICE IAW SRM.SDR IPXA3579556Strap · corrodedINSPECTION TYPE:C-8, VERTICAL STAB TOP CAP INTERNAL METAL STRAP HAS CORROSION. REPLACED METAL STRAP IAW BAC DWG 179N1011-4.SDR IPXA13579602Floorbeam · corrodedINSPECTION TYPE: C-8 MAIN CABIN FLOOR BS 1200, BL 0-LBL 24 HAS CORROSION OUT OF LIMITS. REPAIRED CABIN FLOORBEAM IAW EO B757-5310-51674-A.SDR IPXA13579600Floorbeam · corrodedINSPECTION TYPE:C-8, MAIN CABIN FLOORBEAM BS 1200, LBL 45-62 HAS CORROSION OUT OF LMITS. REPAIRED FLOORBEAM IAW EO B757-5310-51674-A.
Back to N468UP