N475UP
Service difficulty reports · 113
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N475UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N475UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2015053089570Floorboard · delaminatedINSPECTION TYPE: C8, CABIN FLOORBOARD 231XMF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2015053089569Floorboard · delaminatedINSPECTION TYPE: C8, FLOORBOARD 231XRF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW EO B757-5320-9692H.SDR IPXA2015053089567Floorboard · delaminatedINSPECTION TYPE: C8, CABIN FLOORBOARD 231XPF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2015053089566Floorboard · delaminatedINSPECTION TYPE: C8, CABIN FLOORBOARD 231XLF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW B757-5320-9692-H.SDR IPXA2015053089565Floorboard · delaminatedINSPECTION TYPE: C8, FLOORBOARD 231XYF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2015053089572Floorboard · crackedINSPECTION TYPE: C8, CABIN FLOORBOARD 231XCF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2015060189610Floorboard · puncturedINSPECTION TYPE: C8, MAIN CABIN FLOORBOARD 252XUF PUNCTURED IN SEVERAL AREAS. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015052889501Floorboard · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD IS DELAMINATED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015052889500Floor Panel · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOOR PANEL 232XYF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015052889499Floor Panel · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOOR PANEL 232XMF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060689871Frame · dentedINSPECTION TYPE: C-8, FWD CARGO BAY BS 680, STR 23R FRAME DENTED. REPAIRED THE FRAME IAW SRM 53-00-07-2R-5, FIGURE 201, SHEET 4, DETAIL I.SDR IPXA2015060689870Frame · dentedINSPECTION TYPE:C-8, FWD CARGO BAY RT BS 740, STR 25R, FRAME DENTED. REPAIRED THE FRAME IAW SRM 53-00-07-2R-5 FIGURE 201, SHEET 8, DETAIL III.SDR IPXA2015060789911Frame · dentedINSPECTION TYPE:C8, FWD CARGO BAY LT SIDE BS 680 FRAME AT 25L DENTED. REPAIRED DENTED FRAME IN FWD CARGO COMPARTMENT BS 680, STR 25L IAW SRM 53-00-07-2R-5, FIG 501, DETAIL III.SDR IPXA2015060289708Skin · dentedINSPECTION TYPE: C-8, LT HORIZONTAL STABILIZER LOWER SKIN HAS DENT BETWEEN RIB 3 AND RIB 4, FRONT AND AUX SPAR. REPAIRED WITH METAL HOT BOND REPAIR IAW SRM 51-70-10, REPAIR 2 AND 51-70-10-2R GENERAL.SDR IPXA2015060889948Skin · gougedINSPECTION TYPE: C-8, LEFT WING NR 3 SLAT T/E WEDGE HAS A GOUGE ON LOWER SURFACE AFT END. ACCOMPLISHED METAL HOT BOND REPAIR IAW EO B757-5750-57717-A & REO-G18941, REV A.SDR IPXA2015060889947Skin · dentedINSPECTION TYPE:C-8, RT WING NR 7 SLAT UPPER EXT SURFACE DENTED. ACCOMPLISHED METAL HOT BOND REPAIR IAW EO B757-5750-57716-A & REO-G18942, REV A.SDR IPXA2015060889945Skin · dentedINSPECTION TYPE: C-8, 3 SLAT UPPER SURFACE HAS MULTIPLE DENTS. ACCOMPLISHED METAL HOT BONDED REPAIR IAW EO B757-5750-57717-A & REO-G18941, REV A.SDR IPXA2014111784856Floor Panel · damagedMCD FLOOR PANEL DAMAGED. FABRICATED A NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA13578618Floor Panel · puncturedINSPECTION TYPE:S3C7, FLOOR PANEL 211AXF PUNCTURED. FABRICATED NEW FLOOR PANEL IAW EO B757-9320 -9692H.SDR IPXA13578616Floor Panel · puncturedINSPECTION TYPE:S3C7, MAIN DECK FLOOR PANEL 252XUF HAS PUNCTURES. FABRICATED NEW FLOOR PANEL IAW EO B757-932 0-9692-H.SDR IPXA3577844Floor Panel · dentedPOS NR 6 MCD FLOOR PANEL RT CENTER DENTED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3577438Skin · dentedRT OTBD AFT FLAP LOWER SKIN DENTED. REPAIRED IAW EO B757-5750-50087-A.SDR IPXA2572238Sliding Window · bindingAFTER PRESSURIZED FLIGHT, CAPTAIN`S SLIDING WINDOW LOCK IS BINDING BADLY. CLEAN AND LUBE WINDOW AND TRACK. OPS CHECKED OK ON GROUND.SDR IPXA2572237Sliding Window · unknownCAPTAIN`S SLIDING WINDOW LATCH IS BINDING AFTER ACFT IS PRESSURIZED. PERFORMED ADJUSTMENT TEST OF OPENING MECHANISM ON CAPTAIN`S SLIDING WINDOW. ALL FUNCTIONS OF WINDOW CHECKED GOOD IAW AMM 56-11-02-5. NO BINDING AT THIS TIME.SDR IPXA12570957Skin · gougedFUSELAGE SKIN GOUGED AT BS 620 BETWEEN S13-14L. REPAIRED REF EO-B757-5330-45260-B.SDR IPXA11569347Wire · damagedDURING DESCENT LT HYD QTY EICAS MSG WAS DISPLAYED. QUANTITY GOT DOWN TO .25 AT SHUTDOWN QTY RETURNED TO 1.0. DEFERRED IAW MEL 29-33-2, DMP 29-33-2 C/W. ASSIGNED 462077. ETOPS-REF TASK H150926. REPLACED WIRING BETWEEN D40366P AND D02538 AND INSTALLED NEW CONNSDR IPXA20110913001AHydraulic System · warning lightDURING DESCENT LEFT HYDRAULIC FLUID QUANTITY EICAS MESSAGE WAS DISPLAYED. QUANTITY GOT DOWN TO .25, AT SHUTDOWN QTY RETURNED TO 1.0. DEFERRED IAW MEL 29-33-2, DMP 29-33-2 C/W. OPENSDR IPXA1568542Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 242XEF DAMAGED. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1568480Floorboard · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOORBOARD 241XDF HAS EDGE DAMAGE. FABRICATED REPLACEMENT FLOORBOARD 241XDF IAW B757-5320-9692-G.SDR IPXA11568415Floor Panel · damagedINSPECTION TYPE:C, CK MAIN CARGO COMPARTMENT FLOOR PANEL 242XFF DAMAGED. FABRICATED FLOOR PANEL IAW EO B757-5320-9632-G.SDR IPXA11568414Floor Panel · damagedINSPECTION TYPE:C, CK MAIN CARGO COMPARTMENT FLOOR PANEL 242XGF DAMAGED. FABRICATED FLOOR PANEL IAW EO B757-5320-9632-GSDR IPXA11568413Floor Panel · damagedINSPECTION TYPE:C, CK MAIN CARGO COMPARTMENT FLOOR PANEL 242XDF DAMAGED. FABRICATED FLOOR PANEL IAW EO B757-5320-9632-G.SDR IPXA11568410Floor Panel · damagedINSPECTION TYPE:C, CK MAIN CARGO COMPARTMENT FLOOR PANEL 241XEF DAMAGED. FABRICATED FLOOR PANEL IAW EO B757-5320-9632-G.SDR IPXA11568409Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 241XJF DAMAGED. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11568416Floor Panel · tornINSPECTION TYPE:C, CK MAIN CARGO COMPARTMENT FLOOR PANEL 242XJF IS TORN OUT AT INSERT. REPLACED FLOOR PANEL 242XJF IAW EO B757-5320-9692-G.SDR IPXA11568407Floor Panel · tornINSPECTION TYPE:C. CK MAIN CARGO COMPARTMENT FLOOR PANEL 242XCF IS TORN OUT AT INSERT. REPLACED FLOOR PANEL 242XCF IAW EO B757-5320-9692-G.SDR IPXA11568399Floor Panel · crushedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 242XFF IS CRUSHED AT CORNER. REPLACED FLOOR PANEL 242XFF IAW EO B757-5320-9692-G.SDR IPXA11568398Floor Panel · tornINSPECTION TYPE:C, CK MAIN CARGO COMPARTMENT FLOOR PANEL 242XMF IS TORN OUT AT INSERT. REPLACED FLOOR PANEL 242XMF IAW EO B757-5320-9692-G.SDR IPXA11568436Floor Panel · damagedINSPECTION TYPE:C, CK MAIN CARGO COMPARTMENT PANEL 241XMF HAS SEVERAL MISSING AND DAMAGED INSERTS. REPLACED FLOOR PANEL 241XMF IAW EO B757-5320-9692-G.SDR IPXA1568544Floor Support · dentedINSPECTION TYPE:C-CK AFT CARGO COMPARTMENT STA 1455 LBL 10 FLOOR SUPPORT HAS DAMAGE DENTED. FABRICATED AND INSTALLED REPAIR IAW SRM 51-70-11-0G.SDR IPXA1568543Frame · dentedINSPECTION TYPE:C-CK, AFT CARGO COMPARTMENT STA 1580 BETWEEN STRINGERS 25L AND 26L HAS DENTS. FABRICATED AND INSTALLED NEW FRAME FROM STRINGER 25L TO 25R IAW SRM 51 -40-02SDR IPXA1568524Frame · dentedINSPECTION TYPE:C-CK, AFT CARGO COMPARTMENT STA 1620, STRINGER 26R, FRAME HAS DENT. REMOVED DAMAGE FABRICATED REPAIR DOUBLER 7075-0 -071 HEAT TREATED TO T 6 DRILLED UP TREATED AND PRIMED AND INSTALLED IAW SRM 53-00-072R5, DETAIL 3.SDR IPXA1568479Frame · dentedINSPECTION TYPE:C-CK, AFT CARGO COMPARTMENT STA 1540 BETWEEN STRINGERS 25R AND 26R DENTED. REPAIRED FRAME IAW SRM 53-00-07-2R 5, REPAIR 5 DETAIL III, EO B757-5310-43711-A ISSUED FOR FASTENER SUBSTITUTION AT S25R & S26R CLIP LOCATIONS.SDR IPXA1566630Floor Panel · dentedMAIN CARGO DECK FLOOR PANEL POSITION 5 RT SIDE HAS 3 SMALL DENTS. ID FLOOR PANEL AS PN 143N5457-90 AT BS 780-820 RT SIDE IAW EO B757-5320-969 2 FABRICATED A REPLACEMENT FLOOR PANEL.SDR IPXA1566629Floor Panel · dentedMAIN CARGO DECK FLOOR PANEL POSITION 5 RT SIDE HAS 3 SMALL DENTS. FABRICATED A REPLACE FLOOR PANEL BY CUTTING OUT A NEW FLOOR PANEL FROM A402H. DRILLED AND CLEARED HOLES OF DEBRIS. INSTALLED INSERTS USING BMS 5-107 AND CURED FOR 2 HRS AT +140 F. MARKED USDR IPXA10563464Link · inoperativeCAPT SLIDING WINDOW DIFFICULT TO OPEN, UNABLE TO CLOSE. R & R ARM LINK TO L2 WINDOW. ADJUSTED ARM LINK AND UPPER CTR ROLLER. WINDOW OPENS AND CLOSES NORMALLY.SDR IPXA09557761Clutch · out of adjustCAPTS WINDOW RELEASE HANDLE BINDING. RELEASE HANDLE OPERATING NORMALLY WHEN WINDOW IS FULLY CLOSED. FOUND ADJUSTMENT CLUTCH LOOSE ALLOWING WINDOW TO FALL OPEN. ADJUSTED CLUTCH PER AMM 56-11-02.SDR IPXA09557427Acm · seizedINSPECTION TYPE:N/A FLT DECK FAILS TO MAINTAIN DESIRED TEMP IN AUTO. DURING CLIMB AT 8K LT EEC INOP LIGHT & LT LIMITER LIGHT WITH ASSOCIATED EICAS MESG. CAPTS SLIDING WINDOW W/N OPEN. EICAS MSG R PACK TEMP AND RT PACK INOP LIGHT DISPLAYED. AT 13K MSL SMELLSDR IPXA09556848Support Bracket · crackedINSPECTION TYPE:C1 APU FIRE BOTTLE BRACKET IS CRACKED AT THE I/B FWD BOLT HOLE. REMOVED AND REPLACED FIRE BOTTLE SUPPORT BRACKET IAW SRM 51-40-02-0G.SDR IPXA09556849Floor Panel · puncturedINSPECTION TYPE:C1 BULK CARGO NR 2 FLOOR PANEL PUNCTURED 2 PLACES. FABRICATED REPLACEMENT PANEL PER SRM 53-60-53-01.
Back to N475UP