N480UA
Service difficulty reports · 117
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N480UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N480UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2016121900001Battery · faultedCIDS REPORTED LEFT AND RIGHT BATT PACK FAULTS. REMOVED AND REPLACED LEFT AND RIGHT EMERGENCY LIGHT BATTERY PACKS. OPS CHECK GOOD.SDR CALA2016032895235Control Handle · faultyGEAR NOT LOCKED ECAM MSG. GO AROUND, CYCLED, MSG REMAINED. MANUAL EXTENSION FOUND LG SELECTOR HANDLE AT FAULT, REPLACED SAME. OPERATIONS CHECKED GOOD.SDR CALA2016012295013Battery · faultedEMERGENCY POWER SUPPLY UNIT BATTERY EMER LIGHT FAULT DURING TEST. REMOVED & REINSTALLED BATTERY, FAULT CLEARED & BITE CHECKED GOOD.SDR CALA2015081894225Stringer · corrodedSTRINGER 42L IN AFT CARGO COMPARTMENT IS CORRODED FROM FRAME 57 & 60. REMOVED STRINGER 42L, SPLICES FROM FRAME 57 & 60. INSTALLED NEW STRINGER & SPLICES IAW SRM 53-00-13, TABLE 201.SDR CALA2014042590896Skin · corrodedFORWARD PIT FWD FRAME 34 BETWEEN STRINGERS 42R & 41R HAS CORROSION AROUND FASTENERS ON INNER SURFACE OF SKIN. REMOVED .011 OF .091 SKIN IAW SRM 53-21-11 FIG 114 SHEET 1 P149. REMOVED LESS THAN 25% & FOUND TO BE IN LIMIT.SDR CALA2014042590895Skin · corrodedFORWARD PIT FWD FRAME 34 BETWEEN STRINGERS 42L & 40L, CORROSION AROUND FASTENERS ON INNER SURFACE OF SKIN. REMOVED .012 OF.071 SKIN IAW SRM 53-21-11 FIG 114 SHEET 1 P149, REMOVED LESS THAN 25% & FOUND TO BE IN LIMIT.SDR CALA2014042590894Skin · corrodedFORWARD PIT FWD FRAME 34 BETWEEN STRINGER 43R & 42R HAS CORROSION AROUND FASTENERS ON INNER SURFACE OF SKIN. REMOVED .014 OF.071 SKIN IAW SRM 53-21-11 FIG 114 SHEET 1 P149. REMOVED LESS THAN 25% & FOUND TO BE IN LIMIT.SDR CALA2014032690696Autopilot Sys · malfunctionedDIVERT TO LAX DUE TO AUTO FLIGHT CONTROL ISSUE.SDR CALA2014032090651Idg · malfunctionedGEN 1 DID NOT COME ON AT START UNTIL GEN SWITCH CYCLED, WHEN GEN 1 CYCLED DURING GND CHECKS, IT DID NOT COME ON FIRST TIME & SHOWED VOLTS. R & R NR 1 ENG IDG. OPERATIONS CHECK & LEAK CHECKED GOOD AMM 24-21-00-72 0-042.SDR CALA2014031490605Web · corrodedAFT CARGO WEB BETWEEN FRAME 52 TO FRAME 56 & STRINGER 9R TO STRINGER 41R HAS CORROSION. R & R AFT CARGO WEB FRAME 52 TO FRAME 56 IAW SRM 57-42-11 P7 - 9.SDR CALA2014031490604Stringer · corrodedFWD CARGO PIT, FWD STRINGER 43R HAS CORROSION AT FRAME 34. R & R STRINGER 43 RT FROM FRAME 30 TO FRAME 35 IAW SRM 51-42-11 P 7 & 24.SDR CALA2014031090568Skin · corrodedFWD PIT FWD FRAME 34 BETWEEN STRINGERS 42R & 41R HAS CORROSION AROUND FASTENERS ON INNER SURFACE OF SKIN. REMOVED .011 OF .091 SKIN.SDR CALA2014031090567Skin · corrodedFWD PIT FWD FRAME 34 BETWEEN STRINGERS 42L & 40L, CORROSION AROUND FASTENERS ON INNER SURFACE OF SKIN. REMOVED .012 OF .071 SKIN.SDR CALA2014031090566Skin · corrodedFWD PIT HAS CORROSION AROUND FASTENERS ON INNER SURFACE OF SKIN. REMOVED .014 OF.071 SKIN.SDR CALA2014030790540Skin · corrodedRT OVERWING REFUEL HOLE LANDING HAS MINOR CORROSION ON COMPLETE LANDING, 8.32 TOTAL SQ INCHES. CORROSION WAS REMOVED IAW SRM 51-74-00 & FLAP PEENED PRECAUTIONARY IAW SR M51-29-11. WITHIN SRM 57-21-11 PAGE 244 PARA 5FD LIMIT OF .020, MAX MATERIAL LOSS WAS .01SDR CALA2014030790539Skin · corrodedLT OVERWING REFUEL HOLE LANDING HAS MINOR CORROSION ON COMPLETE LANDING, 8.32 TOTAL SQ INCHES. CORROSION WAS REMOVED IAW SRM 51-74-00 & FLAP PEENED, PRECAUTIONARY IAW SR M51-29-11. WITHIN SRM 57-21-11 P244 PARA 5FD LIMIT OF .020, MAX MATERIAL REMOVED AT FWD ESDR CALA2014030790538Skin · wornNR 1 PYLON LOWER SURFACE WORN AT RIB FROM CNA SEAL. AREA WAS BLENDED IAW SRM51-73-00 WITH MAX WEAR OF .007 & WITHIN SRM54-51-12 FIGURE 103 LIMIT. INSTALLED ANTI CHAFING PLATE REPAIR IAW SRM 54-51-12 FIGURE 202.SDR CALA2014030790536Frame · corrodedFWD CARGO PIT FWD FRAME 34 CORROSION AROUND FASTENERS ON STRINGER 42R. R & R STRINGER 42.SDR CALA2014022790494Stringer · corrodedSTRINGER 42L IN AFT CARGO COMPARTMENT IS CORRODED FROM FRAME 57 TO FRAME 60.SDR CALA2013122393865Fastener · missingSCREW MISSING ADJACENT TO BELLY ROT BCN PNL 192FB. MAINTENANCE REPORTED NO MISSING FASTENERS AT PANEL 192FB, HAS ONE MISSING FASTENER AT PANEL 192KB. PANEL 192KB MISSING ONE EACH FASTENER OK TO CONT IAW CF 725 IAW AMM 53-35-00-200-002-A. REPAIR INSTALLED NESDR CALA2013121693745Computer · faultySIDE STICK PRIORITY DISPLAYED ON UPPER ECAM SCREEN F CTL. REPLACED NR 1 ELAC, OPERATIONS TESTED OKAY.SDR CALA2013092791506Restraint · frayedFORWARD FLIGHT ATTENDANT JUMP SEAT SHOULDER HARNESS FRAYED. REPLACED RESTRAINT IAW MM.SDR UALA2013071604972Brake · fireRIGHT OTBD BRAKE CAUGHT FIRE ON ROLL IN TO GATE. NO INDICATIONS OF BRAKE OVERHEAT OR DRAGGING ALL INDICATIONS WERE REPORTED NORMAL. REMOVED WHEEL, FOUND BURNED RESIDUE ON NR 4 BRAKE DISCS AND ON TIRE HEAT SHIELD. REPLACED NR 4 BRAKE REF MM AND NR 4 TIRE REFSDR UALA2013062604468Door · missing1 COCKPIT CREW LIFE VEST MISSING. DOOR FOR LIFE VEST MISSING FROM SECOND OBSERVER SEAT. THIS IS THE SEAT BEHIND THE CAPTAIN'S SEAT. SEAT IS NOT TO BE USED. REPLACED VEST.SDR UALA2013051403350Power Supply · no testEMERGENCY LIGHTS WILL NOT TEST WITH MESSAGE EPSU COMM FWD LEFT DISPLAYED. REPLACED DOOR 1 LT EPSU AND BATTERY IAW AMM 33 51-38, OPS CHECKED EMERGENCY LIGHTS GOOD.SDR UALA2013041702623Slat · dentedBIRD STRIKE ON LEADING EDGE OF WING INBOARD OF NR 2 ENGINE LEAVING A DENT ON LEADING EDGE. DENT LOCATED NR 1 RT SLAT APPROXIMATELY CENTER OF 4TH BAY FROM OUTBD EDGE. DENT AND SURROUNDING DEFORMITY ON UPPER AREA DIMMS. ARE 6.25 IN.W X4.25 (CHORDWISE), DENT DSDR UALA2013032802004Pouch · brokenLIFE VEST POUCH UNDER SEAT 24F IS BROKEN. REPLACED LIFE VEST UNDER SEAT 24F. OK FOR SERVICE.SDR UALA2013031101452Controller · faultyANTI ICE RIGHT WINDSHIELD UPPER ECAM AGAIN. REPLACED RIGHT WINDOW HEAT CONTROLLER, GND CHECK OK AND FAULT WENT AWAY AND WINDOW STARTED TO HEAT UP.SDR UALA2013021800982Lens · brokenDOOR 1L ENTRY LIGHT LENS BROKEN.SDR UALA2013020400670Strut · dischargedNOSE STRUT IS FLAT. INSPECTED NOSE STRUT EXTENSION, FOUND AREA DRY, INSTALLED STRUT GAUGE TO FIND STRUT LOW, SERVICE STRUT PRESSURE TO PROPER LIMITS, IAW AMM.SDR UALA2012121407218Valve · faultedAFT CARGO HEAT FAULT DISPLAYED ON UPPER ECAM SCREEN. PERFORMED TSM IAW 21-43-0 0-810-811-A; HOT AIR PRESS REG VALVE FAULT. REPLACED TRIM AIR VALVE PER AMM. OPS CHECKED CARGO SMOKE DET PER AMM, ALL GOOD. NO ECAM WARNINGS OR FAILURES OBSERVED.SDR UALA2012092905531Controller · inoperativeF/O'S WINDSHIELD HEAT IS INOP. REPLACED F/O WINDOW HEAT CONTROLLER AS PER AMM.SDR UALA2012090605032Latch · defectiveO2 MASKS FELL FROM CEILING AROUND ROW 11. THE 10ABC OXYGEN PSU WILL NOT LATCH. SEATS 10ABC NOT TO BE OCCUPIED.SDR UALA2012082304713Panel · malfunctionedO2 PANEL DROPPED AT 1A-1B. PAX O2 MASK COMP RE-INSTALLED. MASKS RE-STOWED PER AMM. DEFERRED DROP CHECK PER MT 35-003 ON OR BEFORE 3 DAYS MAX TIME LIMIT AND NOT EXTENDABLE. ACCMP'D OPERATIONAL CHECK OF MANUAL MASK RELEASE, CHECKS GOOD.SDR UALA2012080804263Battery Pack · faultyEPSU BATTERY FWD L MSG DISPLAYED AFTER EMERGENCY LIGHT TEST PER 3SVC. REPLACED BATTERY PACK AND BATTERY. TESTED NORMAL.SDR UALA2012050402635Rod End · faultyAIRFRAME VIBRATION ON CLIMB-OUT AT FL300. 78MLT VIBRATION IN COCKPIT LT-MOD VIBRATION IN AFT GALLEY. CREW REPORTED VIBRATION IN AFT CABIN RATED AT MODERATE. BLUE AND YELLOW ROD ENDS REPLACED. SSDR UALA2012042002392Rod End · out of toleranceVIBRATION REPORTED. VIBRATION FELT IN REAR CABIN. REPLACED LT ELEVATOR, BLUE PCU ROD END. ADJUSTED PER MM. NO OTHER SETTINGS OUT OF TOLERANCE.SDR UALA2012022000975Power Supply · inoperativeEMERGENCY EXIT LIGHTS ON WITH SWITCH OFF. REPLACED POWER SUPPLY UNIT PER AMM, OPS GOOD.SDR UALA2012021000813Seal · damagedDEBRIEFED INBOUND FLIGHT, COMMENTED THAT COMING INTO SFO WHEN FLAPS WAS BEING LOWER, AIRFRAME STARTED TO RUMBLE AND FEELS LIKE A LATERAL VIBRATION. PER FLIGHT CREW, HAS HISTORY ON FLAPS ISSUE. CK TRAILING FLAP FAIRING AND FOUND TO BE NORMAL, ALSO CK NLG DOORSDR UALA2011123007163Pin · out of adjustO2 MASK FELL AT 37DEF. :UNABLE TO PROPERLY SECURE DOOR IN FULLY CLOSED POSITION. ADJUSTED LATCHING PIN.SDR UALA2011122807136Oxygen Mask · out of positionO2 MASK FELL AT 37DEF.SDR UALA2011112106404Buffer · defectiveCAPT RUDDER PEDALS FAIL TO MOVE FORWARD FROM MOST EXTENDED POSITION AS WELL AS MOST. REPLACED RUDDER PEDAL BUFFER, OPS CHECK GOOD.SDR UALA2011100505395Seal · leakingCREW O2 FAILED, FLIGHT DIVERTED CREW O2 PRESSURE IS DECREASING EN ROUTE. STARTED AT 900 PSI DOWN TO 750 PSI AND CONTINUED TO DECREASE. REPLACED 2ND OBSERVER'S MASK AND BOX ASSY WITH NEW COPPER FLAIR SEAL LEAK CHECKED OKAY.SDR UALA2011092905286Seal · faultyTHE 2ND OBS O2 MASK DOES NOT TEST PROPERLY. WHEN PRESSED TO TEST FLOW DOES NOT STOP. REPAIRED O2 MASK AND BOX ASSY WITH NEW COPPER FLAIR SEAL. OPS AND LEAK CHECKED GOOD.SDR UALA2011083104692Tape · missingVIBRATION-NOISE ENCOUNTERED IN FLIGHT. NEED TO COMPLETE VIBRATION REPORTING CHECKLIST AND DEBRIEF MAINTENANCE (SAMC) ON ARRIVAL TO DESTINATION STATION. CREW COMMENTS: VIBRATION WITH FULL FLAPS. NONE WITH FLAPS 3 ON FINAL. FOUND TAPE FROM CF271 ON OVER WINGSDR UALA2011040401627Bungee · defectiveF/O FOOT PEDAL ADJUSTMENT STICKY. NEEDS LUBE. RUDDER PEDAL MOVEMENT IS NOT EFFECTED BY RUDDER PEDAL ADJ. PEDALS DO NOT STICK OR BIND, PEDALS ARE WEAK TO RETURN WHEN RELEASE ADJ LEVER IS PULLED. CONFIRMED WITH OPBLM PARTS NEEDED ARE (644-0296) PART IS LOB INSDR UALA2011030301049Bushing · faultyUNUSUAL VIBRATION WITH FLAPS FULL ON 2 CONSECUTIVE FLIGHTS. ACCOMPLISHED FLT CONT INSPECTION PAYING PARTICULAR ATTENTION TO THE FLAP NR 1 SPHERICAL BEARING LINER MIGRATION. NO DEFECTS NOTED. NO HISTORY AND POST FLT REPORT IS CLEAN. OK TO CONTINUE IN SERVICSDR UALA2011020700644Unknown · odorON APPROACH, GOT HOT PLASTIC ODOR IN COCKPIT AND CABIN. EMERGENCY LIGHTS STARTED FLASHING . CAPT SHUTDOWN CABIN FANS AND GALLEY FANS, EMERGENCY LIGHTS STARTED TO FLASH ON & OFF. CHECKED DISTRIBUTION DUCTS IN MID & FWD E/E BAYS. NO ODOR DETECTED. OPS CHECK EMESDR UALA2011020400598Panel · damagedEMERGENCY LIGHT COVER AT 2L BROKEN OFF. REPLACED AFT ATTENDANT LIGHTING AND COMMAND PANEL AT 2L. ASSOCIATED PANEL FUNCTIONAL TESTED OK.SDR UALA2011011200166Oven · contaminatedCREW REPORTED ODOR OF SMOKE IN COCKPIT DURING DESCENT. TURNED OFF GALLEY POWER & ODOR WENT AWAY. CHECKED THE FWD GALLEY OVEN AND COFFEE WARMERS FOR OPERATION AND POSSIBLE BURNED FOOD OR DAMAGE. INSPECTED OVENS, FOUND TWO BADLY SCORCHED TAGS FROM MEALS, RAN C
Back to N480UA