N491UA
Service difficulty reports · 100
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N491UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N491UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014060591218Lens · missingEMERGENCY EXIT SIGN LENS COVER MISSING AT DOOR 2RT LOWER AFT CORNER. REPLACED LENS COVER AT DOOR 2RT, OPERATIONS CHECKED GOOD.SDR CALA2014011590154Battery · faultyDURING EMERGENCY LIGHT CHECK ON 2 SERVICE, ESPU BATTERY EMERGENCY LT IS FAULTING. REPLACED EPSU EMERGENCY POWER SUPPLY UNIT BATTERY AT LT MID, OPERATIONS CHECKED OK.SDR CALA2014011590153Light · inoperativeSEAT 28C EMERGENCY EXIT LIGHT IS INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT IAW MM 33-51-19, OPERATIONS OK.SDR CALA2013121693706Tachometer · faultyAUTO BRAKE FAULT DISPLAYED ON UPPER ECAM SCREEN. BRAKE FAULT ON ROLL OUT. LT TRUCK BRAKE TEMPS DIFFER BY MORE THAN 300, 55 - 405 DEGREES. R & R NR 1 MLG TACHOMETER 19GG IAW AMM 32-42-57-400-001-B. PERFORMED FUNCTIONAL TEST IAW AMM 32-42-00-720-003-A, CHECKSDR CALA2013121693705Rail · lack of lubeCAPTAIN`S RUDDER PEDAL RETURN MECHANISM IS INOPERATIVE. RUDDER PEDALS ARE USEABLE ADJUSTABLE & ALLOW UNRESTRICTED MOVEMENT, THEY JUST WON'T RETURN FROM ADJUSTMENT. LUBED RAIL 27 41 43 CHECKED OK.SDR CALA2013120993536Contactor · faultyPILOT REPORTED BCL 2 DISPLAYED ON UPPER ECAM. REPLACED NR 2 LINE CONTACTOR IAW AMM, OPERATIONS CHECKED NORMAL, MESSAGE CLEARED.SDR CALA2013111893003Sliding Window · delaminated2 INCH DIAMETER DELAMINATION BUBBLE CAPTAIN'S SLIDING WINDOW BETWEEN PANES. DELAMINATION LOCATED FWD EDGE OF WINDOW, HALF WAY FROM THE TOP, 2" INCH DIAMETER STARTING FROM THE EDGE. CARRIED FWD IAW AMM 56-12-11, WITHIN LIMITS IAW AMM.SDR CALA2013110192571Transceiver · faultyWXR INOPERATIVE - NAV. RADAR INTERMITTENTLY DISPLAYS GREEN ARC AT RANDOM RANGES. RESET SAFTER CYCLING PWR SWITCH. REPLACED WXR TRANSCEIVER, HAD XMTR DRVR CAL FAULTS LOGGED IN TRANSCEIVER. IAW AMM 34-41- 33 OPERATIONS CHECKED GOOD.SDR CALA2013110592646Ignition Lead · defectiveAPU WILL NOT START, HANGS AT 18% N1. REPLACED IGNITION UNIT IAW MM-49-41-38, NO HELP. REPLACED FUEL CONTROL UNIT FOR TROUBLESHOOTING IAW MM, NO HELP. REPLACED IGNITER PLUGS & LOWER IGNITION LEAD IAW MMS. OPERATIONS CHECKED GOOD.SDR CALA2013092691467Seat Belt · mismanufacturedSECOND OBSERVER`S LT LAP BELT ADJUSTMENT IS BACKWARD BY MANUFACTURER. SEAT IS INOPERATIVE. UNSERVICEABLESDR UALA2013071805042Valve · inoperativeCARGO HEAT, HOT AIR MIX VALVE WILL NOT OPEN. EVEN WHEN SELECTED TO FULL HOT. MAX SUPPLY TEMP 70F.SDR UALA2013062004283Line · brokenONE PYLON HYD RESERVOIR PRESSURIZATION LINE BROKEN. REPLACED LINE.SDR UALA2013061804227Shield · damagedCAPTAIN'S OXYGEN FACE SHIELD IS DAMAGED. REPLACED CAPTAIN'S OXYGEN FACE SHIELD IAW AMM.SDR UALA2013022001035Filter · missingCABIN CREW REPORTS SMOKE DETECTOR IN FWD AFT LAV TAMPERED WITH. FOUND SMOKE DETECTOR FILTER IN FWD AFT LAV REMOVED. RE-INSTALLED FILTER AND ACCOMPLISHED OPS CHECK PER AMM, TESTS OKAY.SDR UALA2013012200393Valve · leakingDURING WALKAROUND FOUND HYDRAULIC FLUID LEAKING FROM PARKING BRAKE VALVE. REPLACED PARKING BRAKE VALVE.SDR UALA2013010900151Switch · stuckCAPTAINS TRIGGER STICKS ON SIDESTICK. REMOVED AND REPLACED CAPTAINS TRIGGER MICROPHONE SWITCH IAW AMM, OP'S CHECKED GOOD.SDR UALA2012100105562Unknown · odorCIGARETTE SMOKE SMELL OFF AND ON IN AFT GALLEY. CHECKED ALL APPLIANCES IN AFT GALLEY AND BOTH LAVS FOR ELEC SYSTEM DISCREPANCIES. CHECKED APU INLET-EXH. CHECKED PACK INLETS AND ENGINES INLET-EXH. CHECKED AFT CARGO COMPT, NO MECH OR ELEC DISCREPANCIES OR EVSDR UALA2012071803901Liner · damagedNR 1 ENGINE MISSING 1.5 INCH BY 1.5 INCH SECTION IN THE FAN CASE ATTRITION LINER AT 1 O'CLOCK POSITION. REPAIRED PER MT 72-017 REF PTT 6822015 AND PTT 6822019.SDR UALA2012070603644Diaphragm · failedR-1 DOOR BOTTLE READS 'O' PSI. REMOVED AND REPLACED R-1 DOOR ASSIST BOTTLE DIAPHRAGM, SERVICES R-1 DOOR ASSIST BOTTLE.SDR UALA2012052702952Controller · malfunctionedCOCKPIT TEMP IS NOT CONTROLLABLE. REPLACED PACK TEMP CONTROLLER, OPS CHECKED OKAY.SDR UALA2012051602778Selector Valve · failedPER ACFT POST FLT REPORT LGCIU2 05GA2 - LANDING GEAR DOORS SELECTOR VALVE 41GA IS FAILING. REPLACED MLG DOOR 41GA SELECTOR VALVE PER MM.SDR UALA2012043002536Servo · failedNW STEER FAULT DISPLAYED ON UPPER ECAM SCREEN. UPON GEAR EXTENSION INFLIGHT. FOUND FAILURE MESSAGE FOR LT LG DOOR CLOSED PROXIMITY SENSOR 29GA, INSTALLED NEW REF MM32-31-73. TESTED, NO HITS. REPLACED NOSE WHEEL STEERING SERVO CONTROL IAW AMM 32-51-51. OPS SDR UALA2012031201578Battery · failedACP 3 SVC CABIN EMERGENCY CHECK, FAILED. FAULTED EPSU BATTERY FWD L. REPLACED BATTERY.SDR UALA2012020300670Engine · damagedBIRDSTRIKE, RTFL. ON CLIMB OUT AIRCRAFT EXPERIENCED A BIRD STRIKE, FOLLOWED BY ENGINE NR 2 VIBRATION. REFER TO MT72-021 FOR INSPECTION REQUIREMENTS. ENGINE REPLACEMENT REQUIRED DUE FOD INGESTION. REPLACED ENG PER MT71-017.SDR UALA2011122107006Actuator · malfunctionedC-B C14 ON OH PANEL OPENED IN CRUISE. HYD FIRE VALVE Y ENG 2. REPLACED THE RIGHT ENGINE PUMP FIRE VALVE ACTUATOR IAW AMM. ACCOMPLISHED FUNCTIONAL CHECK OF THE HYDRAULIC FIRE SHUT-OFF VALVE IAW AMM, ALL CHECKS GOOD.SDR UALA2011110906097Actuator · unsecureCREW REPORT: 27C SEATBACK IS ROCKER. SAMC TEXT: CONTACT SAMC: FOUND RECLINE ACTUATOR DANGLING. RE-SECURED PER MAINT MNL. RE-SECURED PER MM. SEAT IS TOTALLY USABLE.SDR UALA2011060802823Control Panel · faultyBURNING SMELL EMANATING FROM THROTTLE QUADRANT AND LEFT SIDE RADIOHEAD. SAMC TEXT: CHECK 105VU AND 106VU PANELS FOR EVIDENCE OF SMOKE ODOR BEFORE CLEARING THIS ITEM. ALSO, PERFORM GENERAL VISUAL INSPECTION OF 95VU RACK AREA FOR ANY SOURCE OF SMOKE SMELL. CASDR UALA2011060202696Computer · malfunctionedELAC 2 PITCH FAULT DISPLAYED ON UPPER ECAM SCREEN. - F-CTL. REPLACED ELAC2 PASS ALL TESTS AND CAT 3 LAND PASS PER MM.SDR UALA2011051302389Power Supply · failedEMERGENCY LIGHT TEST FAILS. FAULTS EPSU COM EMERGENCY L. REPLACED POWER SUPPLY 11WL,TEST CK GOOD.SDR UALA2010081302968Drain Mast · brokenNR 1 ENG HAD CONTACT WITH BELT LOADER. NEED TO OPEN FAN COWLS AND INSPECT FOR DAMAGE UNDER COWLING. LCL FBO OPENED FAN COWLS IAW AMM AND CHECKED FOR DAMAGE. FOUND DRAIN MAST BROKEN AND LOWER EDGE OF LT FAN COWL DAMAGED. FAN COWLS ARE SECURED CLOSED.SDR UALA2010032300993Power Supply · inoperativeEMERGENCY LIGHT TEST FAILED. REPLACED BATTERY EPSU OVER LT WING 11WL, GROUND TEST OK.SDR UALA2009092903065Switch · malfunctionedEMERGENCY OXYGEN MASKS AT SEATS 16DEF FAILED TO DEPLOY. REPLACED SOLENOID ACTUATOR DOOR SWITCH AT 16DEF.SDR UALA2009092803044Anti-Ice Valve · failedCABIN PRESS FAILURE, FLT DIVERTED. REPLACED NR 1 ENG THERMOSTAT FAN AIR VALVE CONTROL. RT WING ANTI-ICE VALVE REPLACED. NR 2 ENG BLEED NO FAULTS. PERFORMED ENG BLEED SYS TEST, PARAMETERS NORMAL NO FAULTS, PERFORMED NR 1 & NR 2 ENG POWER ASSURANCE CHECKS. SDR UALA2009090802804Wire · pinchedTHE 13WL EPSU FAILED CHECK. REPLACED EPSU, NO HELP. NEED TO TROUBLESHOOT AND CORRECT. ALSO NEED TO OP CHECK. FOUND EMERGENCY LIGHT WIRE PINCHED UNDER SEAT ASSY 24ABC. REPAIRED WIRE, OPS CHECKS GOOD.SDR UALA2009052601483Connector · unsecure3 SVC FAILED CABIN EMERGENCY LIGHT TEST. EPSU-BATTERY AFT L, FOUND CONNECTOR ON AFT DOOR 2L EPSU ITEM LIST NR 5 13WL BACKED OFF ABOUT HALF WAY. SECURED CONNECTOR. CFDS EMERGENCY LIGHT TESTS OK.SDR UALA2009041301047Unknown · odorON TOUCHDOWN F/A IN AFT JUMP SEAT DETECTED SMOKE. ODOR WENT AWAY UPON TURNING OFF ALL CHILLERS. RAN CHILLERS, COFFEEMAKERS AND OVENS IN AFT GALLEY FOR 20 MINUTES, NO SMELL NOTED. ALSO CHECKED WATER HEATERS IN AFT LAVS, NO ODOR NOTED. NO FURTHER MAINT ACTIOSDR UALA2009022300607Light · inoperativeEMERGENCY EXIT LIGHT AT 6C INOPERATIVE. RELAMPED EMERGENCY LIGHT, OPS GOOD.SDR 2008UALA05477Smoke Detector · faultySMOKE LAVATORY DETECTOR FAULT AT FL350. FOUND DEFECTIVE SMOKE DETECTOR. REPLACED SMOKE DETECTOR. TESTS OKAY ON CFDS TEST & CIDS.SDR 2008UALA00367Computer · faultyON DEPARTURE FIRST OFFICERS PITCH TRIM DID NOT WORK. AIRCRAFT PITCHED UP UNTIL OVERRIDDEN WITH NOSE DOWN JOYSTICK COMMAND. CAPT PITCH TRIM WORKS NORMAL WHEN COUPLED WITH EITHER AUTOPILOT. ELAC2 FAULT. REPLACED ELAC2, OPS CHECKED GOOD.SDR 2008UALA00253Sill · corrodedR2 DOOR SILL PLATE HAS CORROSION AT FASTENER HOLE LOCATION FWD END AT FR66 AND AT AFT END AT FR 69 ON OUTER RADIUS. PERFORMED MAJOR REPAIR AT LCQ.SDR 2007UALA03539Engine · oil consumptionNR 1 ENGINE HIGH OIL CONSUMPTION EXCEEDS LIMIT. FOUND NR 5 BEARING SEAL LEAK. REPLACED NR 1 ENGINE.SDR 2007UALA03472Rod End · out of adjustLIGHT AIRFRAME VIBRATION IN CLIMB. VIBRATION STOPPED AT FL250. FOUND ELEVATOR SERVO CONTROL ROD ENDS OUT OF ADJUSTMENT. ADJUSTED INBD AND OTBD ELEV SERVO CONTROL ROD ENDS. NO REPEATS SINCE ORIGINAL.SDR 2007UALA02580Power Supply · faultyEMERGENCY LIGHT SYSTEM FAILS TEST, FAULTS PWR SUPPLY ABOVE DOOR 1L. [07-27-07] REPLACED BATTERY AND UNIT NOW CHECKS GOOD.SDR 2007UALA02388Battery · dischargedFOUND EMERGENCY LIGHTING BATTERIES LOW ON CHARGE AT FWD LEFT AND MID LEFT. REPLACED BATTERY & PERFORMED SUCCESSFUL CIDS TEST.SDR 2007UALA00296Battery · failedAFT EMERGENCY LIGHT BATTERY FAILED 3SVC TEST. REPLACED AFT EMERGENCY LIGHT BATTERY. OPS CHECKED GOODSDR 2006UALA01331Slide · faultyCABIN EMERGENCY LTS FAILED TEST IND EPSU EXT LOAD AFT L. TROUBLE SHOT SYSTEM. 2L SLIDE REPLACED PER MM 25-23-45.SDR 2006UALA01129A/C Pack · malfunctionedLOST BOTH PACKS, FLIGHT DIVERTED. FOUND AIR LEAK AT RT WING LEADING EDGE, AT THE DUCT CONNECTION BETWEEN TRACK 2 AND 3. THERE WAS EVIDENCE OF BURN MARKS AT JOINT. REPLACED 4 SEALS FROM PNEUMATIC DUCTING LEADING TO AFT OF NR 1 PYLON HEAT EXCHANGER. REPLACED SDR 2006UALA00086Light · no testEMERGENCY LIGHTS FAIL 3 SERVICE TEST.SDR 2006UALA00056Skin · damagedFOUND DAMAGE APPROX 4 FEET AFT OF AFT CARGO DOOR AT STA 29896-FR63 BETWEEN STRINGERS 39R AND 41R. MAJOR REPAIR. REPAIRED STR 39R BETWEEN FR 62 & 63 PER SRM 53-00-13 FIG201. INSTALLED SKIN DOUBLER REPAIR PER SRM 53- 00-11 FIG 209 & 211.SDR 2005UALA01447Bulkhead · ground damageBULKHEAD DAMAGE AT STATION 350 APPROXIMATELY 14 INCHES RIGHT OF FR 1. DAMAGE CAUSED BY IMPACT WITH GROUND EQUIPMENT. HORIZONTAL STIFFENER REPLACE, BULKHEAD WEB DOUBLER INSTALLED, FRAME REPAIR, AND VERTICAL STIFFENER DOUBLER INSTALLED.
Back to N491UA