What was found
APU WILL NOT START, HANGS AT 18% N1. REPLACED IGNITION UNIT IAW MM-49-41-38, NO HELP. REPLACED FUEL CONTROL UNIT FOR TROUBLESHOOTING IAW MM, NO HELP. REPLACED IGNITER PLUGS & LOWER IGNITION LEAD IAW MMS. OPERATIONS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU WILL NOT START, HANGS AT 18% N1. REPLACED IGNITION UNIT IAW MM-49-41-38, NO HELP. REPLACED FUEL CONTROL UNIT FOR TROUBLESHOOTING IAW MM, NO HELP. REPLACED IGNITER PLUGS & LOWER IGNITION LEAD IAW MMS. OPERATIONS CHECKED GOOD.