N492HA
Service difficulty reports · 40
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N492HA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N492HA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2026082466519Battery · unserviceableOVERWING EMERGENCY LIGHTS INOPERATIVE. GROUNDED - YES. REPLACED OVERWING EMERGENCY LIGHT BATTERY POWER SUPPLY PER AMM 33-51-06. OPS CHECK GOOD. AC OK TO CONTINUE SERVICE.SDR ASAA2026081666366Light · inoperativeFWD LT OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. GROUNDED - YES. OPS CHECK OK PER AMM 33-51-00.SDR ASAA2026063065628Compressor · stalledRETURN TO AIRPORT -LEFT ENGINE COMP STALL ON TAKEOFF DOUBLE BANG AT GEAR RETRACTION - RAN AT IDLE. GROUNDED - YES. PERFORME EEC BITE & FAULT REVIEW - NO FAULTS. PER FIM 72-00 TASK 801, AMM 72-00-00-200-80CALLED OUT. PERFORMED STEPS UP TO INCLUDING 2E. PERFORMSDR ASAA2026021763443Windshear Sys · false indicationINFO TO MX ABORT/ REJECTED TAKEOFF IN OGG DUE TO HEAD WINDSHEAR AURAL MESSAGE GROUND SPEED AUPPROX 80 KTS. IAS APPROX 100 KTS. GROUNDED - YES. PERFORM TEST WINDSHEAR PER 22-10 TASK 8-11 NO FAULT FOUND. OK FOR SVC.SDR HALA20241004047Lamp · inoperativeCOCKPIT EMERGENCY LIGHT INOP. RELAMPED CP EMERGENCY LIGHTS AND INSTALLED NEW BATTERY PACK AT B5-123, OPS TEST PER AMM 33-51-03 OK.SDR HALA20240528028Compressor · stalledLEFT ENG COMPRESSOR STALL. REMOVED ENG1 BOOSTER BLEED VALVE (BBV) PER AMM 75-32-01 5/26/24 24713. INSTALLED BOOSTER BLEED VALVE IN SERVCABLE CONDITION ON #1 ENG PER AMM 75-32-01 UP TO STEP F.2.(E). REMOVED #1 ENG SN 13438 PER HAL TASKCARD E1128-717-72-0003-REMSDR HALA20240524026Compressor · stalledENG L COMP STALL ON TAKE OFF @ 1600' (ATB). PERFORMED EEC 1 BITE - FC 801105 STARTER AIR VALVE OUT OF POSITION. REPLACED #1 ENGINE START VALVE PER AMM 80-11-03. OPS CHECK & LEAK CHECK NEED TO BE ACCOMPLISHED. BORESCOPE INSP PERFORMED NO FINDINGS AMM 72-33-00-2SDR HALA20240521025Compressor · stalledATB - ENG L. COMP STALL @ APPX 1500' ON CLIMBOUT. CONDITION IMPROVED ON POWER REDUCTION. NORMAL LANDING PERFORMED. COMPLETED INSPECTION OF THE ENGINE AFTER HIGH POWER SURGE AMM 72-00-200-801 UP TO STEP 2.E. (7) -N. DAMAGE FOUND NO DAMAGE NOTED. ENG 1 ON COMPRESDR HALA20240401017Blade · damaged#5 FAN BLADE #2 ENGINE MAJOR DAMAGE. REMOVED #2 ENG BLADE SET PER AMM72-38-15. 17601 3-29-24 PERFORMED INSPECTION OF #2 ENGINE FOR FOD PER AMM 72-00-00--200-809. INSTALLLED #2 ENGINE BLADE ASSEMBLY PER AMM 72-38-15.SDR HALA2022100600269None · noneBOTH OVERWING EMERGENCY LIGHTS INOP. REMOVED AND REPLACED OVERWING EMERGENCY LIGHTS BATTERY POWER SUPPLY PER AMM 33-51-06. OPS CHECK GOOD. OK FOR SVC.SDR HALA2022011800016Cable · inoperativeEMER EQ - LFT MAIN CABIN DOOR EMER SLIDE ARMING CABLE INOP // REMOVED AND REPLACED 1L DOOR EMERG SLIDE ARMING CABLE. SECURE OK TO CONTINUE.SDR HALA2021120800183Engine · inoperativeCREW REPORTED THAT INBND TO OGG THEY HAD ENG1 BRG OVHT MSG, PER FCOM PROCEDURES CREW SHUT DOWN AFFECTED ENG // MX TROUBLESHOOTING, FOUND METAL FINDINGS FROM OIL FILTER & FBC STRAINER. HAL PP ENGINEERING HAS DETERMINED THAT AN ENG CHANGE IS REQUIRED. MX CURRENTSDR HALA2021050300053Door · out of adjustEMER EQ - MAIN ENTRY DOOR WILL NOT CLOSE PROPERLY -REPEAT WRITE UP // ACCOMPLISHED AMM 52-11-01/501 ADJUSTMENT TEST DOOR ,PASSENGER FORWARD ENTRY TEST OPS CK OK NO FAULTS NOTED REINSTALLED SLIDE SHUTE PER AMM 25-61-01/401SDR HALA2021043000052Lock · obstructedEMER EQ - MAIN ENTRY DOOR WILL NOT CLOSE PROPERLY // FOUND SAFETY WIRE ON LOCK ADJUSTMENT ARM CAUSING JAM. REMOVED AND REPLACED SAFETY. OPS CHECK OK. OK FOR SERVICE. REF AMM 52-11-01SDR HALA2020120800216Engine · failedATB-RT ENGINE COMP STALL RT ENGINE OIL PRESS 0. REMOVED & REPLACED #2 ENG PER W/O 181624 REF TASK CARD E1128-717-72-003-INSTALL OPS/LEAK CHECK OK.SDR HALA2020100100190Lens · detachedMISSING EMERGENCY LIGHT COVER AT ROW 11 RT. COVER DOES NOT HOLD ONTO ASSEMBLY. REMOVED AND REPLACED THE OVERHEAD EMERGENCY LIGHT ASSEMBLY AT ROW 11 RTM, PER AMM 33-51-08-400-801.SDR HALA2020092903138Beam · cracked492 C CHECK. SMALL CRACKS ON THE MED NR 6 BEAM (P/N: 9955757-503) AT/NEAR THE BAYONET CRANK FITTING BOLT HOLE. REPAIRED MED NR 6 BEAM, PER E105-B10650-PERM 08/17/2020.SDR HALA2020092903137Structure · corroded492 C CHECK. SM S/C AROUND STA 974 AND LONG 30 (M). REMOVED CORROSION, PER B717SRM 51-10-04-OG-O. FOUND TO BE BEYOND LIMITS, PER SRM 53-00-090-1A 0 FIG 103 M66 SUBMITTED. PENDING INSTALLATION OF FASTENERS TREAT PRIME AND PAINT POST REPAIR. INSTALLED LOCK SDR HALA2020092903136Former · corroded492 C CHECK. CORROSION UNDERNEATH BONDING WIRE ON LEFT FILLET FORMER 4TH BACK FROM FWD (M). REMOVED CORROSION, PER SRM 51-10-04. FOUND TO BE OUT OF LIMITS. M66 SUBMITTED. CORROSION BLEND ON THE WING TO FUSELAGE FILLET FORMER AT Y=636 SURFACE CORROSIOSDR HALA2020092903135Flange · cracked492 C CHECK. CRACKED END FLANGE OF THE KEEL TO CANTED PANEL ATTACH FORMER AT Y=715. REMOVED FORMER FOR REPAIR. 08/18/2020 MECH 16912 M66 SUBMITTED 2. REPAIRED PER E105-492093-PERM UP TO STEP 6. 8-26-20 MECH 16148 INSP 7924 INSTALLATION PENDING. COMPLETEDSDR HALA2020092903134Frame · corroded492 C CHECK. CORROSION DISCOVERED ON THE STA 1098.868 FRAME TEE (PN 9971144-61) AT L-28L. THE CORROSION WAS MECHANICALLY REMOVED WITH MORE THAN 50% MATERIAL LOST IN THE VERTICAL FLANGE AND PITTING CORROSION 100% THROUGH THE AFT HORIZONTAL FLANGE. INSTALLED SDR HALA2020092903133Doubler · cracked492 C CHECK, DURING ROUTINE MAINTENANCE TASKS, HWI DISCOVERED A CRACK IN THE STA 1178 BULKHEAD DOUBLER (PN 9911839-265) AND SKIN PANEL (PN 5912141-77), JUST INBOARD OF L-3L. MINOR REPAIR. E105-492092-PERM C/W DATE 09/10/20, MECH 019536. PENDING INSTALLATIONSDR HALA202001300019Oxygen Mask · failedBTB - CAPTAIN OXYGEN MASK LEAKING AT HEADSTRAP AND UNABLE TO BROADCAST ON ON VHF1 OR VHF2,MULTIPLE RESET ATTEMPTS UNSUCESSFUL // REPLACED FAULTY O2 MASK. LOG PAGE # 810474.SDR HALA2019111400483Vane · dentedFOUND A DENT L-1/2 " W 1/4 " D 0.006 " WITH A CRACK 9/32 " LONG AT THE CENTER OF THE DENT DAMAGE LOCATED ON L/H AFT MOVEABLE VANE 15 1/2 " FROM INBOARD EDGE 12 3/16 " FROM TRAILING EDGE UNDER SIDE OF VANE. // PERFORMED COIN TAP TEST AROUND THE AFFECTED AREA NOSDR HALA2019103100463Pump · failedETOPS OPEN - BTB, HYDRAULIC FAIL //PER FIM REPLACE ENG HYD PUMP I.A.W. AMM 29-11-01-400-801. OPS AND LK CK GOOD. OK FOR SVC. REF LOG PAGE DEFECT 764801SDR FOTR2018110918001Doubler · dentedLH ELEVATOR HAS A DENT, 1" X 1" ON THE TOP, O/B SIDE, IN BETWEEN XE 225.834 AND XE 204.114, OR HINGE POINTS 5 AND 6SDR HALA208082000386Control Unit · false indicationAT ABOUT 1200 FT. EMERGENCY POWER CAME ON IN FLT, DURING SHORT FINAL, PERFORMED OPS TEST OF EPCU IAW AMM 24-21-02-700-801. OPS CHECKED OK, OK FOR SERVICE.SDR HALA2018032100118Engine · warning messageCREW REPORTED THE RT ENGINE LOW OIL PRESSURE WARNING AND ENGINE RT SYS FAIL ALERT MESSAGE. REMOVED AND REPLACED THE NR 2 ENGINE IAW M143-717. OPS AND LEAK CHECKED GOOD. OK FOR SERVICE.SDR HALA2017122600330Compressor Blade · missingATB/ RIGHT ENGINE COMP STALL ON EICAS AUDIBLE BANG HEARD BY CREW. BORESCOPE REQUIRED. REMOVED HIGH PRESSURE COMPRESSOR FAIRING AND 6 EA PLUGS. REMOVED HP TURBINE STAGE 2, LP TURBINE STAGE 1, LP TURBINE STAGE 2 PLUGS. REMOVED BREATHER OUTLET. BORESCOPED NR 2 ENSDR HALA2017122600318Blade · missingNR 2 ENGINE COMPRESSOR STALLED IN FLIGHT. REMOVED HIGH PRESSURE COMPRESSOR FAIRING AND SIX PLUGS. REMOVED HP TURBINE STAGE 2, LP TURBINE STAGE 1, LP TURBINE STAGE 2 PLUGS. REMOVED BREATHER OUTLET. BOROSCOPED THE NR 2 ENGINE HPC THROUGH ACCESS PORT D FOUND A SDR HALA201708210230Unknown · unknownVIOLENT BUFFETING AND ROLLING MOMENTS IN BOTH DIRECTIONS ON FLAP EXTENSION. NO INDICATIONS. RETRACTED, EXTENDED AGAIN SLOWLY. OPS NORMAL SECOND ATTEMPT.SDR HALA2017080400217Compressor · stalledRT ENGINE COMPRESSOR STALLED, FOLLOWED BY ENGINE VIBRATION HIGH. SHUT DOWN THE ENGINE. ENGINE CHANGE IN WORK.SDR HALA2016041700113Pitot Head · obstructedON TAKEOFF ROLL AT 80 KTS F/O'S AIRSPEED INDICATOR STARTED DROPPING OFF DUE TO A BEE IN F/O'S PITOT TUBE. CONFIRMED BEE STUCK TO F/O'S PITOT PROBE, CLEARED LINE IAW AMM 34-11-00-171-801, LEAK CHECK OK IAW AMM 34-11-00-790-801. NO BRAKE OVERHEAT NOTED DURING SDR HALA2015082700174Tire · separatedNR 3 MAIN TIRE CAP COMING OFF. TIRE SEPARATED ON TAKEOFF. R & R NR 3 MAIN WHEEL AND TIRE IAW TASK 32-41-01-400-802. SPIN CHECK OK. OPS CHECK OK, ACFT OK FOR SERVICE.SDR HALA2015040400058Switch · malfunctionedLAVATORY SMOKE TEST STAYS ON AFTER TEST. RESET TEST SWITCH FOR LAVATORY SMOKE. MESSAGE EXTINGUISHED. NO DEFECTS NOTED. OK FOR SERVICE.SDR HALA2014011600006Display · inoperativeNR 1 MCDU/FMC WENT BLANK AFTER TAKE OFF. REPLACED NR 1 MCDU. OPS CHECKED OK IAW MM 31-65-01.SDR HALA2013100400131Shutoff Valve · inoperativeDURING START ANTI-SKID FAIL, RETURNED TO GATE, BRAKE RETURN LINE SHUTOFF VALVES. FOUND RT BRAKE LINE, SHUTOFF VALVE INOPERATIVE.SDR HALA2012060100154Smoke Detector · false activationSTATIS MESSAGE FOR LAVATORY SMOKE ON. RESET SMOKE DETECTOR AFT LT, TEST SMOKE DETECTOR CHECKED GOOD.SDR HALA2012022400072Pump · failedLAVATORY SMOKE ALERT WITH ODOR. RETURN TO GATE, AFT RT LAVATORY LOCKED CLOSED. R & R CHEMICAL INJECTION PUMP AND ENVIROMENTAL CLEAN, OPS AND LEAK CHECKED OK IAW AMM 38-32-01.SDR HALA2012022300069Power Supply · malfunctionedAFT EMERGENCY EXIT SIGN ILLUMINATED. R & R AFT EXIT DOOR POWER SUPPLY. OPS CHECKED EMERGENCY LIGHTING, OK.
Back to N492HA