N498CA
Service difficulty reports · 149
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N498CA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N498CA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA2019030545604Structure · dentedDENT FOUND AT APPROX. FS 700 ABOVE STGR 15L. (C-CHECK) RO: 03/02/2019 REPAIRED DENTS AT APPROX FS700 IAW REO.SDR SWIA2019030545605Doubler · corrodedCORROSION ON DOUBLER AT RT FS 349 ABOVE SERVICE DOOR LOWER SILL. (C-CHECK) RO: 03/02/2019 REPAIRED THE DOUBLER AT RT FS 349 ABOVE SERVICE DOOR LOWER SILL IAW REO.SDR SWIA2019030545603Floorbeam · corrodedCORROSION ON IN BOARD LBL9 FLOORBEAM FLANGE FS570.00 €“ FS609.00. (C-CHECK) RO: 03/02/2019 REMOVED AND INSTALLED NEW FLOORBEAM CAP AT LBL 9 BETWEEN F.S 570 AND F.S 615 IAW REO.SDR SWIA2019030545602Frame · corrodedCORROSION ON FLANGE OF FRAME, FS605.00, STGR21L €“ STGR23L. (C-CHECK) RO: 03/02/2019 BLENDED/REMOVED CORROSION FROM FS605 FRAME LOWER FLANGES LOCATED BETWEEN STGR-21L & STGR-23L IAW REO. PRESSURE CHECK GOOD.SDR SWIA2019030545601Structure · dentedTWO DENTS APROX LBL 8 OUTBD STR 26 APROX FS 273. (C-CHECK) RO: 03/02/2019 PERFORMED DENT REPAIR AT APPROX. FS 273 STR 26 LBL 8 IAW REO. PRESSURE CHECK GOOD.SDR SWIA2019030545600Structure · dentedTWO DENTS APROX RBL6 BETWEEN STR 26 AND 27 BETWEEN FS 250 AND 265. (C-CHECK) RO: 03/02/2019 REPAIRED THE TWO DENTS APROX RBL6 BETWEEN STR 26 AND 27 BETWEEN FS 250 AND FS 265 REF REO. PRESSURE CHECKS GOOD.SDR SWIA2019030545599Skin · dentedTHREE DENTS APPROX RBL 6 BETWEEN STRG 26 AND 27 APPROX FS 276. (C-CHECK) RO: 03/02/2019 DRESSED DISCREPANT SKIN TO ORIGINAL CONTOUR IN 3 SPOTS AND REPAIRED AREA IAW REO. PRESSURE CHECK GOOD.SDR SWIA2019030545598Vane · chafedRT INBOARD FLP VANE LEADING EDGE HAS CHAFING AT THE INBOARD, CENTER, AND OUTBOARD SECTIONS OF FLAP VANE. (C-CHECK) RO: 03/02/2019 REMOVED DAMAGED O/B AND I/B RT FLAP VANE LEADING EDGE CAP AND REPLACED WITH NEW CAP IAW SRM.SDR SWIA2019030545597Stop Fitting · chafedAVIONICS BAY DOOR LT & RT STOP FITTINGS ON FUSELAGE CHAFED. (C-CHECK) RO: 03/02/2019 REMOVED AND INSTALLED NEW FWD, LT AND RT AVIONICS DOOR STOP FITTINGS AND ALL HARDWARE IAW SRM. OPERATIONAL CHECK OF THE AVIONICS DOOR GOOD IAW AMM.SDR SWIA2018121745376Selector Valve · failedGEAR DISAGREE ON ARRIVAL. BOTH MAIN LANDING GEAR WOULD NOT COME DOWN. PULLED THE MANUAL RELEASE HANDLE AND GEAR CAME DOWN VIA THE QRH. (FLT#7392) CLOSED REMOVED AND REPLACED THE MAIN LANDING GEAR SELECTOR VALVE IAW AMM.PERFORMED MULTIPLE SUCCESSFUL GEAR SWINGSSDR SWIA201743018Frame · corrodedAVIONICS BAY BELOW FLOORBOARD AT BS 319 FRAME HAS CORROSION AT STRINGER 27. COMPLIED WITH REO, ALL STEPS COMPLETED OF PERMANENT REPAIR.SDR SWIA201743017Skin · corrodedRIGHT FUSELAGE SKIN HAS CORRODED AND GOUGED BETWEEN STRINGERS 22 AND 24R, BS 559 +96. COMPLIED WITH REO ALL STEPS COMPLETED OF PERMANENT REPAIR.SDR SWIA201743016Skin · corrodedFUSELAGE SKIN HAS CORROSION AT BS 559 TO 559 +112 STRINGER 26L TO 26R. COMPLIED WITH REO, ALL STEPS COMPLETED OF PERMANENT REPAIR.SDR SWIA201743015Vane · chafedLEFT INBOARD FLAP VANE CENTER SECTION HAS A DEEP CHAFE AREA. REMOVED AND REPLACED THE FLAP VANE, IAW SRM.SDR SWIA201641901Engine · flamed outNR 2 ENGINE FLAMED OUT AFTER TAKEOFF. ATTEMPTED TO RELIGHT ENGINE, UNSUCCESSFUL. CREW DECLARED AN EMERGENCY AND DIVERTED. CABIN WAS BRACED AND THE ACFT LANDED SAFELY. TAXIED TO THE GATE UNDER ITS OWN POWER. R & R RT ENGINE ASSY. OPS CHECKS AND LEAK CHECKS SDR SWIA201641791Sensor · malfunctionedNOSE DOOR OPEN, NOSE GEAR DISAGREE MESSAGES RETURNED TO THE FIELD. ADJUSTED NOSE LANDING GEAR CENTERING SENSOR. OPS CHECKED GOOD.SDR SWIA2015021040707Skin · crackedLEFT SIDE SKIN AT A FWD EQUIPT COMPARTMENT AFT LATCH LOCATION HAS SUSPECT CRACK. CREMOVED AND INSTALLED NEW TRU SKIN REF SRM AND STS EA COMPLIED WITH ST 51-900-1003.SDR SWIA2015021040712Shroud · chafedRIGHT UPPER AILERON SHROUD HAS CHAFE WEAR AT APPROXIMATE LOCATION JUST OTBD OF WS 321.32. R & R RT AILERON SHROUD IAW SRM.SDR SWIA2015021040711Bulkhead · crackedEMERGENCY BRAKE PASS THRU AT FS 202 CRACKED. REPAIRED FS 202 BULKHEAD WHERE EMERGENCY BRAKE, PARKING BRAKE CABLE, PASSES THROUGH THE BULKHEAD REF REO. COMPLIED WITH ST AND ALL STEPS OF REO. PRESSURE LEAK CHECK GOOD.SDR SWIA2015021040710Floor Panel · crackedPRESSURE FLOOR AT FRAME STA 461 BL0-LBL9 CRACKED. REPAIRED PRESSURE FLOOR AT FS 461 BL 0 - LBL 9 IAW REO. REPAIRED BY CUTTING OUT CRACKS AND INSTALLING REPAIR DOUBLERS. COMPLIED WITH ST 51-900-1003. PRESSURE LEAK CHECK OF REPAIR IS GOOD REF AMM.SDR SWIA201540709Floor Panel · crackedPRESSURE FLOOR AT FRAME STA 461, BL0, RBL 9 CRACKED. REPAIRED PRESSURE FLOOR AT FS 461, BL 0 - RBL 9 IAW REO. REPAIRED BY CUTTING OUT CRACKS AND INSTALLING REPAIR DOUBLERS. COMPLIED WITH ST 51-900-1003. PRESSURE LEAK CHECK OF REPAIR IS GOOD REF AMM.SDR SWIA2015021040708Floorbeam · crackedFS 484, RBL 36 UPPER ANGLE HAS CRACK AT RIVET LOCATION. C-CHECK, RO 2/8/15, PERFORMED CUTOUT OF INTERCOSTAL AT FS 484, RBL 36 AND INSTALLED -2 REPAIR ANGLE AT FS 484.0, RBL 36 IAW REO. PRESSURE LEAK CHECK GOOD REF AMM.SDR SWIA201439161Proximity Sensor · failedWOW INPUT DURING GEAR RETRACTION. R & R WOW PROXIMITY SENSOR RT INBD MLG AND UPPER SECTION HARNESS IAW AMM,SDR SWIA201437524Lamp · burned outEXTERNAL EMERGENCY LIGHT IS BURNED OUT. REPLACED THE LAMP.SDR SWIA201437350Proximity Sensor · failedSERVICE DOOR CAUTION MESSAGE DURING APPROACH AND SMOKE IN THE COCKPIT FROM THE FLOOR UP. REPLACED SERVICED DOOR OUTER HANDLE PROXIMITY SENSOR.SDR SWIA201335372Inverter · failedLT OVERWING EMERGENCY EXIT LOWER LIGHT DOES NOT ILLUMINATE. FLT 6209 REPLACED EMERGENCY LIGHT INVERTER FOR LT SIDEWALL EMERGENCY LIGHT. OPERATIONS CHECKED GOOD.SDR SWIA201335342Splice · brokenFLOOR LEVEL EMERGENCY EXIT AT MAIN CABIN DOOR DOES NOT ILLUMINATE. FLT 3486 REPLACED DEFECTIVE SPLICE IAW AMM. OPERATIONS CHECKED GOOD.SDR SWIA201334715Light · inoperativeNR 1 EMERGENCY OVERHEAD LIGHT IS BURNED OUT. FLT#5505 RELAMPED.SDR SWIA201334611Light · inoperativeRT OVERWING EXTERIOR EMERGENCY EXIT LIGHT IS BURNED OUT. FLT#5517 RELAMPED.SDR SWIA201334610Light · inoperativeNR 2 EMERGENCY OVERHEAD LIGHT IS BURNED OUT. FLT#5327 RELAMPED.SDR SWIA201334609Light · inoperativeLT FWD OVERWING EXTERIOR EMERGENCY LIGHT IS BURNED OUT. SERVICE RELAMPED.SDR SWIA201334608Connector · looseEXIT ROW 8, LT SIDE, EMERGENCY LIGHT FLOOR LEVEL DOES NOT ILLUMINATE. FLT#5361 SECURED LOOSE CONNECTOR.SDR SWIA201333375Floorbeam · corrodedCARGO FLOORBEAM TOP CAP AT LBL 27 AND FS 621 HAS CORROSION. (C-CHECK) REPLACED WITH NEW CARGO FLOORBEAM AT LBL 27 FOR FS 569 TO FS 621 IAW REO.SDR SWIA201333374Door · chafedLEFT MAIN LANDING GEAR DOOR HAS CHAFE ON FORWARD CORNER NEAR WHEEL BRUSH. (C-CHECK) REPAIRED LEFT MAIN LANDING GEAR DOOR CHAFE IAW REO.SDR SWIA201333373Plate · corrodedCARGO LANDING PLATE HAS CORROSION ON LOWER SIDE UNDER NUT PLATES. (C-CHECK) REPLACED CARGO LANDING PLATE IAW REO AND SRM.SDR SWIA201333372Angle · crackedFS 280.0 FLOORBEAM UPPER ANGLE HAS A CRACK AT RBL 10.0. (C-CHECK) REPAIRED CRACK AT FS 280.0 RBL 10.0 UPPER ANGLE IAW REO.SDR SWIA201333371Fitting · crackedFLOORBEAM CLIP AT FS 280.0 RBL 11.0 IS CRACKED. (C-CHECK) REPLACED CLIP AT FS 280.0 RBL 11.0 WITH NEW P/N 601R-53-11-171-5 AND SHIM-6 IAW REO AND SRM.SDR SWIA201333370Bulkhead · crackedFS 621 AFT PRESSURE BULKHEAD FORWARD SIDE CRACK INDICATION NOTED ON WEB AT AFT CARGO TRACK (UPPER). (C-CHECK) REPAIRED FS 621 AFT PRESSURE BULKHEAD FORWARD SIDE FOR CRACK NOTED ON WEB AT AFT CARGO TRACK (UPPER) IAW REO.SDR SWIA201333254Wire · looseA/C LEFT EMERGENCY EXIT OVERWING DOOR LOWER EXIT SIGN DOES NOT ILLUMINATE. (FLT 2959) RE-SECURED LOOSE WIRE IAW AMM.SDR SWIA201333122Light · inoperativeREAR OVERHEAD EMERGENCY LIGHT BURNED OUT. (FLT 2977) RELAMPED EMERGENCY LIGHT.SDR SWIA201332885Light · inoperativeNR 1 EMERGENCY OVERHEAD LIGHT BURNED OUT. (FLT 2953) RELAMPED EMERGENCY LIGHT.SDR SWIA201332751Fuse · blownLEFT OVERWING EMERGENCY EXIT LOWER SIDEWALL EXIT LIGHT DOES NOT ILLUMINATE. (FLT 2916) REPLACED FUSE ON NR 3 EMERGENCY BATTERY CHARGER.SDR SWIA201231316Light · inoperativeEMERGENCY LIGHT IN CENTER AISLE AT ROW 10 IS OUT. (FLT 2950) RELAMPED EMERGENCY LIGHT.SDR SWIA201231201Light · inoperativeNR 1 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 2879) RELAMPED EMERGENCY LIGHT.SDR SWIA201230942Light · inoperativeNR 2 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 7986) RELAMPED EMERGENCY LIGHT.SDR SWIA201230876Windshield · crackedRIGHT WINDSHIELD ARCING AT ALTITUDE AND SHATTERED AFTER LANDING. (FLT 2980) REPLACED RIGHT WINDSHIELD IN REFERENCE TO AMM. PN OFF NP139321-14 SN OFF 03022H4853.SDR SWIA201230550Light · inoperativeNR 2 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 2967) RELAMPED EMERGENCY LIGHT.SDR SWIA201230293Lamp · burned outFLT 2973, NR 3 OVERHEAD EMERGENCY LIGHT IS OUT. RELAMPED EMERGENCY LIGHT.SDR SWIA201229945Light · inoperativeNR 1 AND NR 3 OVERHEAD EMERGENCY LIGHTS ARE OUT. (FLT 2921) RELAMPED EMERGENCY LIGHTS.SDR SWIA201202149652Lamp · burned outFLT 5544, NR 3 OVERHEAD EMERGENCY LIGHT IS OUT. RELAMPED EMERGENCY LIGHT.
Back to N498CA