N498UA
Service difficulty reports · 85
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N498UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N498UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013050203071Psu · unsecurePSU PANEL ABOVE SEATS 31DEF FALLING DOWN - NEEDS SECURED. RE-SECURED PANEL, OK FOR SERVICE.SDR UALA2013041502599Receptacle · damagedFASTENER AT FWD EDGE 197BB PANEL LOOSE. REPLACED RECEPTICLE.SDR UALA2013040402252Rivet · missingF/O O2 MASK IS MISSING 1 PLASTIC RIVET INLINE WITH TOP OF NOSE BRIDGE SUPPORT STRUCTURE. COMPLIED WITH MEL 35-11R SECOND OFFICERS O2 MASK WAS SWAPPED WITH FIRST OFFICERS. RPL- :REMOVED AND REPLACED O2 MASK REFERENCE AMM, OPS CHECKED GOOD.SDR UALA2013040102103Knob · intermittentALTITUDE SELECT KNOB ON MCP IS INTERMITTENT, UNABLE TO CHANGE ALTITUDE AT TIMES. REPLACED FCU PER AMM. SYSTEM OPS TESTS NORMAL PER AMM- 22-96-00.SDR UALA2013022801209Latch · brokenOVERHEAD EMERGENCY ROPE STOW COMPARTMENT DOOR LATCH BROKEN AT LOCATION 20ABC. REPLACED LATCH.SDR UALA2013012400414Contactor · faultyDC ESS BUSS SHED DISPLAYED ON UPPER ECAM SCREEN. REPLACED ESSENTIAL DC BUSS CONTACTOR OPERATED NORMAL FIM 3PE REF AMM.SDR UALA2013012400407Battery Pack · faultedPER NR 2 SERVICE CHECK, FOUND FLIGHT ATTENDANT PANEL CIDS FAULT, EPSU BATTERY. REPLACED BATTERY PACK.SDR UALA2012090705054Computer · faultyELAC 1 PITCH FAULT DISPLAYED ON UPPER ECAM SCREEN. FLT CONTROL ELAC 1 FAULT. REMOVED AND REPLACED ELAC NR 1, CHECKS NORMAL PER AMM. FLT CONTROL ELAC 1 FAULT. CHECKS NORMAL PER AMM.SDR UALA2012030501376Eec · faultyENG 2 FADEC B FAULT, RTFL. WITH FADEC2 GRD POWER SWITCH ON, NO RESPONSE WHEN FADEC 2A AND 2B LINE SELECT KEYS PRESSED ON MCDU FOR CFDS TEST. EIU-2 GROUND SCAN SHOWED NO FAILURE. EEC PCN 482-9585, EIU PCN 482-9526. REPLACED NR 2 ENG EEC PER MM. OPS CHECK GSDR UALA2012010300053Container · brokenPAX O2 MASKS DEPLOYED 37DEF BY PAX WHO THOUGHT IT WAS UNDEPLOYED TV SCREEN. TAPED UP. INSPECT LATCH AND VERIFY OXYGEN GENERATOR HAS NOT BEEN FIRED. OXYGEN PANEL WILL NOT RE-ENGAGE TO LOCK, TAPED SECURE IN CLOSED POSITION. PLACARD SEATS 37 D, E, AND F 'INOPSDR UALA2011121406855Computer · malfunctionedCAPTAIN'S WINDSHIELD HEAT IS INOPERATIVE WITH ECAM MESSAGE. REPLACED WINDOW HEAT COMPUTER PER AMM. OPS CHECKEDD GOOD. MESSAGE CLEARED.SDR UALA2011111706290Cable · brokenFOUND WIRES BROKEN ON CAPT SLIDING WINDOW AT LOWER END OF CONDUIT TUBE. OPEN AND TAGGED CB'S 13X,14X,ON 122VU. REMOVED CABLE ASSY PCN-565-2286. WILL NOT BE ABLE TO CHECK OUT NEW CABLE DUE TO TR2 BEING REMOVED (MR24501 REF SMC3).SDR UALA2011102505794Anti-Ice System · faultedLEFT WINDOW ANTI-ICE DISPLAYED ON UPPER ECAM SCREEN. REPLACED WINDSHIELD.SDR UALA2011092705229Smoke Detector · faultyUNABLE TO TEST SYSTEM UNTIL RESET OF BOTH CHANNELS OF THE SDCU. THEN TESTED OK. AFTER THIS RESET FAULT RETURNED WITHIN 5 MINS. REPLACED SMOKE DETECTOR 1WH IN FWD LDCC, TESTED GOOD.SDR UALA2011092705230Smoke Detector · faultyECAM SMOKE LAV+CRG DEFAULT. REPEAT WRITE-UP. REPLACED FWD LDCC 1WH, TESTS GOOD. LOG 2...CFDS SHOWS SAME FAULT AS PREV. UNABLE TO TEST SYSTEM UNTIL RESET OF BOTH CHANNELS OF THE SDCU. THEN TEST OK. AFTER THIS RESET FAULT RETURNED WITHIN 5 MINS. REF MM TRBSDR UALA2011082204440Structure · damagedNR 1 ENGINE COMPRESSOR SECTION HAS A 1X1 HOLE AT 6 O'CLOCK POS IN HONEYCOMB UNDER BLADES. MX DETERMINED THE DEPTH OF OF THE HOLE TO BE ONE-QUATRER OF AN INCH DEEP, IT IS NOT THRU THE GLASS REINFORCED COMPOSITE LAYER. REF AMM 72-32-85. OK. TO CONTINUE IN SERVICSDR UALA2011062403121Oil System · leakingFLIGHT ATTENDANTS AND PAX REPORTING MUSTY ODOR IN ACFT. ACCOMPLISHED MT72-016 FOR APU OIL LEAK REPAIR. ACCOMPLISHED MM71-00-00-810 -801 ON NR 2 ENG NO OIL CONTAMINATION FOUND IN HP NR 3 BEARING AREA. ACCOMPLISHED PACK BURN OUT WITH ENGINES AND APU.SDR UALA2011032401408Servo · vibrationAIRFRAME VIBRATION FELT IN AFT GALLEY. WENT AWAY W- RUDDER APPLICATION. REPORT FORM COMPLETED. SAMC TEXT: REFERENCE TSM FOR RUDDER TRAILING EDGE PLAY CHECKS. REPLACED ALL THREE RUDDER SERVO CONTROL ROD ENDS. PLAY BEFORE REPLACEMENT: Y=15MM, B=17MM, G=19MMSDR UALA2011032401409Computer · faultyAT SHUTDOWN ECAM F-CTL SIDESTICK PRIORITY. REPLACED NR 1 ELAC PER MM. ACCOMPLISHED ELAC TEST, REF MM AND AFS TEST, REF MM AND LAND CAT III TEST, REF MM. ALL TESTS PASS.SDR UALA2011032101311Extinguisher · dischargedAFT CABIN HALON FIRE EXTINGUISHER EMPTY. AFT CABIN HALON FIRE EXTINGUISHER EMPTY. REPLACED EXTINGUISHER.SDR UALA2011030201018Ball Lock · faultySLIDE MR25621-050 RECEIVED IN PACKED CONDITION. UPON CHECKING THE BALL LOCKS ON THE ENCLOSURE ASSY, FOUND ONE BALL LOCK (P/N 60878-5) INOPERATIVE. FOUND FOAM IN SUPPLY LINE IN FITTING AT BALL LOCK (SUSPECT MARINE TEX FOAM FROM ORIGINAL MFG). FOUND CHECK VALSDR UALA2010123004767Window · delaminatedFLT CREW REPORTS F/O SLIDING WINDOW HAS DELAMINATION-BUBBLES THAT RESTRICT VIEW FROM CAPT AND F/O SEATS. REPLACED NR2 SLIDING WINDOW. ACP WINDOW HEAT CONTROLLER 1 AND 2 TEST. ALL TESTED PASS.SDR UALA2010101403817Valve · leakingCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. PSI-1480, 100 PSI LOSS IN 4 HRS. CHECKED CREW O2 FOR LEAKS AND FOUND CAPT BOX TEST RESET VALVE LEAKING. REPLACED CAPT O2 BOX. OP CHECKED AND LEAK CHECKED GOOD.SDR UALA2010070602365Gcu · failedNR 2 ENG GEN FAILURE, RTFL. CHECKED CDFS, FOUND LOW OIL PRESSURE. CHECKING OIL LEAKAGE. SVCD ONE QT OF OIL. RAN APU TEST OK. APU HOURS METER READ 02530. TROUBLESHOOTING GEN 2 INOP. PFR FAULTING GCU-2 1XU2. REPLACED GCU 2, TESTS OK IAW CFDS AND RAN ENGINE. GSDR UALA2010051901686Strip · peelingCAPT'S SLIDING GLASS WINDOW NOISY. IT SEEMS AS RUBBER STRIPPING FROM OUTSIDE IS PEELED BACK AND CREATE HIGH NOISE LEVEL. NOT FLUSH. ACFT HISTORY HAS BEEN SIGNED OFF 3 TIMES PRIOR AS CLEANED OR CKD OK. SAMC TEXT: CREW UPDATED WITH: IT IS BECOMING SO NOISY ASSDR UALA2010020800474Liner · delaminatedNR 1 ENG ATTRITION LINER DELAMINATED BEYOND LIMITS. ENG V10450 REPLACED WITH SERVICEABLE ENG V10712 ON JOB CARDS.SDR UALA2009111803592Battery · dischargedDURING EMERGENCY LIGHT OPERATIONAL TEST, GOT EPSU BATTERY EMER R MESSAGE ON CIDS. REPLACED BATTERY OF POWER SUPPLY 12WL RT EMERGENCY LIGHT, OPS TEST NORMAL.SDR 2008UALA05491O-Ring · leakingDOOR 2R SLIDE PRESSURE BOTTLE LOOKS LOW. O-RING LEAKING FROM CENTER BALL SHAFT. REMOVED & REPLACED O-RING.SDR 2008UALA05492Battery · faultyESPU UNIT EMERGENCY LEFT MSG ON CIDS PANEL. REPLACED ESPU BATTERY 11WL. EMERGENCY LIGHT TEST NORMAL.SDR 2008UALA01370Oxygen System · low pressureCREW O2 APPEARS TO HAVE A LEAK. SERVICED CREW O2 TO 2000 PSI, FOUND AT 1475, NO LEAKS WERE PRESENT AT TIME OF SERVICE.SDR 2008UALA00071Battery · dischargedEMERGENCY EXIT LIGHTS ABOVE DOORS FLASH ON-OFF. DISCO EFFECT ON ALL POWER TRANSFERS. WEAK BATTERY. FOUND AFT LEFT EMERGENCY EXIT BATTERY INOP. REPLACED BATTERY, CHECKS NORMAL AT THE GATE.SDR 2007UALA01852Window · damagedCREW REPORTS WINDOW VISIBILITY IS IMPAIRED AND HAS GOTTEN WORSE. WINDOW IS EXTREMELY HOT TO THE TOUCH.SDR 2007UALA00691O-Ring · failedRTFL DUE TO GREEN HYDRAULIC SYSTEM FAILURE. GEAR WAS MANUALLY EXTENDED. REPLACED NR 1 ENGINE HYDRAULIC PUMP, AND NR 1 ENGINE HYDRAULIC PUMP CASE DRAIN FILTER PRECAUTIONARY. LEAK WAS DETERMINED TO BE CAUSED BY A CHECK VALVE PACKING IN THE NR 1 ENGINE PYLON. SDR 2006UALA02406Engine · power lossDIVERTED FLIGHT DUE TO ENGINE POWER CONTROL PROBLEM. ACCOMPLISHED ENGINE RUN. ALL OPS NORMAL 6 SEC UP AND 4 SEC DOWN, BOTH ENGINE ACCELERATION AND DECELERATION EVEN WHEN BOTH THROTTLES MOVE TOGETHER.SDR 2004UALA00896Lamp · inoperativeRED EMERGENCY ESCAPE PATH LIGHT ON BULKHEAD FORWARD OF SEAT ROW 1ABC INOPERATIVE. REPLACED LAMPS.