N519AS
Service difficulty reports · 485
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N519AS' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N519AS' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2017030620082Floor Panel · corrodedFWD PIT FLOOR PANEL HAS MINOR CORROSION ALONG EDGE 120AF. GROUNDED - YES. PANEL 120AF SCRATCHES MORE THAN 3" OUT OF LIMITS IAW SRM 53-00-53. FABRICATED, ALODINED AND PRIMED PANEL 120AF IAW DWG 453A1610 AND SOPM 20-41-01.SDR ASAA2017030620070Floor Panel · corrodedFWD CARGO, FLOOR PANEL 120DF HAS MINOR CORROSION ALONG EDGE. ACFT GROUNDED. FABRICATED A NEW FLOOR PANEL AND APPLIED PROTECTIVE FINISHES IAW DWG 453A1610, REV T, AND GPM 05-00-85 4.A.2.SDR ASAA2017022820103Floorbeam · corrodedCOCKPIT FLOOR STRUCTURE UNDER PANEL 211AF, BARE METAL . DOT ATTACH . ACFT GROUNDED. REPAIRED MAIN CABIN FLOOR STRUCTURE AT BS 270 IAW EA 800-53EA-18556.SDR ASAA2017022520078Skin · crackedR/H HORIZ STAB LWR SKIN APPEARS CRACKED AT STAB STA 128.50 APPROX 17" AFT OF L/E. GROUNDED - YES. REMOVED LEADING EDGE AND TIP, PERFORMED SKIN REPAIR PER SRM 55-10-01-2R-11. REINSTALLED LEADING EDGE AND TIP PER AMM 27-41-21.SDR ASAA2017022320065Channel · corrodedAFT CARGO, RT SIDEPLATE CHANNEL BS 727E - 727F IS CORRODED IN TWO PLACES. ACFT GROUNDED. REMOVED CORROSION IAW SRM 51-10-02, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. REPAIRED THE CHANNEL IAW SRM 53-00-53-2R-6.SDR ASAA2017020519692Duct · wornNR 1 ENGINE INTERSECTION MANIFOLD DUCT ASSEMBLY ATTACH LINK WORN. ACFT GROUNDED. REMOVED AND REPLACED THEE INTERSECTION MANIFOLD DUCT ASSEMBLY ATTACH LINK IAW AMM 36-11-01-400-802.SDR ASAA2017013019599Actuator · faultedLEFT PACK LIGHT ON RECALL, RESETS WHEN MASTER CAUTION PRESSED. ACFT GROUNDED. LT PACK ZONE TEMPERATURE CONTROLLER BITE SHOWS LT RAM AIR ACTUATOR FAULT. REMOVED & REPLACED LEFT RAM AIR ACTUATOR IAW AMM 21-51-21, GROUND FUNCTIONAL CHECKED NORMAL IAW AMM 21-61SDR ASAA2017012619578Starter · contaminatedNR 2 ENGINE STARTER FOUND WITH UNACCEPTABLE AMOUNT OF MAGNETIC CONTAMINATION PER ASA TASK CARD N2480001. ACFT GROUNDED. REMOVED & REPLACED THE NR 2 STARTER UNIT IAW AMM 80-11-01. OPS AND LEAK CHECKED GOOD.SDR ASAA2016122619165Fmc · malfunctionedVTK ON CAPTAINS MAP DISPLAY AND LOSS OF FMC DATA ON BOTH CDUS UPON LANDING AND INTERMITTENTLY THEREAFTER. GROUNDED - YES. DEFERRED PER MEL 34-36J. CAPT SIDE FMC INOP. PLACED FMC SELECT SWITCH TO NORMAL, NO VTK FLAG. NO FAULTS LOGGED IN FMC'S. L FMC OPS NORMALSDR ASAA2016122419130Warning Light · false activationRIGHT PACK ILLUMINATED CLIMBING THRU 150009, RAN QRH AND LIGHT EXTINGUISHED. ACFT GROUNDED. PERFORMED OPS TEST IAW AMM 21-00-00. NO FAULTS NOTED AT THIS TIME. NO HISTORY FOR 30 DAYS.SDR ASAA2016121219019Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. FLIGHT DECK TRIM VALVE FAULT NR 2 ZONE TEMP CONTROLLER. RESET & BITE TESTED NORMAL IAW AMM 21-61-00.SDR ASAA2016120318912Hf Comm · malfunctionedNR 2 HF WILL NOT TRANSMIT OR CHANNELIZE. ACFT GROUNDED.SDR ASAA2016120218911Transceiver · failedNR 2 HF HAD NO SIDE TONE, NO TRANSMIT OR RECEIVE CAPABILITY. ACFT GROUNDED. VERIFIED NR 2 HF WILL NOT TRANSMIT. PERFORMED HF BITE. NO FAILURES INDICATED. REPLACED THE NR 2 HF IAW AMM 23-11-21.SDR ASAA2016111118632Fmc · malfunctionedFMC DISAGREE ON GROUND. ACFT GROUNDED. ACCOMPLISHED RESET PROCEDURE IAW QRH. FMCS RESTORED NORMAL.SDR ASAA2016110918639Starter · failedSTARTING ENG NR 2, NO ROTATION OF N2 OBSERVED ATTEMPTED TO START ENG NR 1 ALL INDICATIONS NORMAL. GROUNDED - YES. REMOVED AND REPLACED NR 2 ENGINE STARTER IN REFERENCE TO AMM 80-11-01-400-801. PERFORMED NR 2 ENGINE STARTER TEST PER AMM TASK 71-00-00-800-811 TESDR ASAA2016102618485Warning Message · false activationLEFT PACK LIGHT ILLUMINATED WHEN CHECKING MASTER CAUTION . LIGHT EXTINGUISHED WHEN PRESSING MASTER CAUTION RESET. AIR COND LIGHT ILLUMINATED ON MASTER CAUTION PANEL. ACFT GROUNDED. CONFIRMED LEFT PACK LIGHT ILLUMINATED ON RECALL. PERFORMED PACK TEMP CONTROLSDR ASAA2016102518477Light · detachedFA REPORTED THE EMERGENCY LIGHTING COMING UP FROM THE FLOOR AT ROW 12. ACFT GROUNDED. SECURED THE LIGHT.SDR ASAA2016101118275Seal · leakingF/A NOTIFIED US OF A VERY LOUD AIR NOISE COMING FROM THE L1 DOOR STARTING AT ABOUT 5,000' ALTITUDE. THE F/O INSPECTED THE DOOR VISUALLY AT 25,000 FT AND SAW DAYLIGHT COMING FROM / NEAR THE UPPER HINGE ON THE FORWARD PART OF THE DOOR SEAL AREA. THE PRESSURIZATISDR ASAA2016100818239Control Unit · failedR2 WINDOW OVERHEAT LIGHT ILLUMINATED. ACFT GROUNDED. REPLACED THE R2 WINDOW HEAT CONTROL UNIT IAW AMM 30-41-11/401. THE NEW WHCU OPS CHECKED GOOD.SDR ASAA2016091518050Warning System · intermittentON FINAL APPROACH, WE GOT THE, FMC DISAGREE, ANNUNCIATION. ACFT GROUNDED. PERFORMED FAULT ISOLATION IAW FIM 34-61, TASK 835. DETERMINED TO BE INTERMITTENT FAULT. OK FOR SERVICE.SDR ASAA2016091117984Warning Light · false activationLIGHT ILLUMINATED ON OVERHEAD PANEL. ACFT GROUNDED. PERFORMED ELEC LIGHT BITE, IAW FIM 24-31 TASK 801. SHOWS STATIC INVERTER INOPERATIVE FAULT. PERFORMED FIM 24-34 TASK 801 & FAULT CLEARED. ALL GROUND FUNCTIONAL TESTS PASSED.SDR ASAA2016083017860Warning Light · false activationRIGHT PACK LIGHT ILLUMINATED DURING MASTER CAUTION RECALL. ACFT GROUNDED. CONFIRMED RIGHT PACK LIGHT ILLUMINATES WITH MASTER RECALL. PERFORMED PACK/ZONE TEMP CONTROL BITE TEST IAW AMM 21-61-00, FOUND NR 2 CONTROLLER WITH "TCV THIS PACK" FAULT LIGHT FROM PREVSDR ASAA2016080217592Valve · malfunctionedON CLIMB OUT, DUCT PRESSURE SPLIT R22, L45 ONCE LEVELED OUT EVENTUALLY COME TOGETHER STEADY AT 40 EACH. ACFT GROUNDED. PERFORMED TASK CARD NG-36WC-00001 BLEED AIR SYS HEALTH CHECK. PERFORMED STEPS 01-05 TO INCLUDE STEP 5. DURING TASK CARD DISCOVERED ENGISDR ASAA2016071517400Module · failedCOLD START TRIED AT FL 380. APU FAULT LIGHT ILLUMINATED. QRH FOLLOWED, APU SHUTDOWN NORMAL. ACFT GROUNDED. IAW TSR908082, REMOVED AND REPLACED APU LUBE MODULE, IAW AMM 49-91-11. OPS CHECKED GOOD, NO LEAKS NOTED.SDR ASAA2016071317367Apu · failedFAULT LIGHT ILLUMINATED DURING APU START ATTEMPT FL 360. ACFT GROUNDED. PERFORMED APU BITE, FOUND FAULT CODE 49-41010. PERFORMED FIM 49-40 TASK 801, NO ACCELERATION SHUTDOWN. UNABLE TO DUPLICATE FAULT ON GROUND. REMOVED AND REPLACED FUEL FLOW DIVIDER ANDSDR ASAA2016071117345Warning System · false activationAPU FAULT LIGHT ILLUMINATED DURING START ATTEMPT FL 380. ACFT GROUNDED. NOTED APU MAINT. MESSAGE 49-41010. NORMAL APU GROUND START ACCOMPLISHED. NO NEW FAULTS.SDR ASAA2016070917299Warning Message · false activationON RECALL, CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED. EXTINGUISHED & RESET ON MASTER CAUTION RESET PUSH. ACFT GROUNDED. PERFORMED PACK TEMP CONTROL BITE ON BOTH CONTROLLERS, NR 2 CONTROLLER FAULTED "FLIGHT DECK TRIM VALVE". CLEARED FAULT IAW FIM 21-62 TASK SDR ASAA2016070417262Connector · failedDURING 1ST CSS START ATTEMPT, A FAULT LIGHT ILLUMINATED AT FL370. QRH ACCOMPLISHED, TURNED APU OFF, FAULT LIGHT EXTINGUISHED. SUCCESSFUL SECOND START ATTEMPT. ACFT GROUNDED. APU BITE MAINTENANCE HISTORY SHOWS MAINT MSG 49-94226, LOW OIL PRESSURE SWITCH SHSDR ASAA2016061817057Actuator · failedLEFT RAM DOOR, FULL OPEN LIGHT ILLUMINATED THROUGH CLIMB AND AT CRUISE. ACFT GROUNDED. R & R LT RAM AIR DOOR ACTUATOR IAW AMM 21-51-21. OPS CHECK NORMAL.SDR ASAA2016061517068Hmu · failedSHORT TERM FAULT FOUND, NR 2 ENGINE 73-20342. FMV POS SIGNAL IS OUT OF RANGE. ACFT GROUNDED. ACCOMPLISHED HMU REMOVAL AND INSTALLATION, REF T/C N8473001. OPS CHECK GOOD. NO FAULTS ON LEG 0 ON EEC BITE CHECK.SDR ASAA2016052616883Radar · malfunctionedWEATHER RADAR RT CIRCUIT BREAKER OPEN ON P6-1 D PANEL. ACFT GROUNDED. INSPECTED AND RESET WXR RT C/B AMM 20-60-01, OPS CHECK WEATHER RADAR AMM 34-43-00. ALL GROUND VERIFICATION TESTS PASS.SDR ASAA2016051516752Line · leakingENGINE 1 HYD PUMP, A SYS, LOW PSI LIGHT CAME ON IN FLIGHT. ACFT GROUNDED. AIR TURNBACK - FOUND NR 1 ENGINE HYDRAULIC PUMP PRESSURE LINE LEAKING AT THE FIREWALL DISCONNECT. R & R NR 1 ENGINE PRESSURE HOSE ASSY AS DEPICTED IN IPC 29-11-51-01A ITEM NR 40. R & RSDR ASAA2016050216597Transceiver · failedNR 2 HF RADIO WILL NOT TUNE AND APPEARS TO NOT RECEIVE. MULTIPLE HF FREQ'S TRIED. AF SENS SET AT 100 PERCENT. ACFT GROUNDED. REPLACED NR 2 HF TRANSCEIVER IAW AMM 23-11-21-000-801. GROUND VERIFICATION CHECK GOOD IAW AMM 23-11-21-400-801.SDR ASAA2016041716434Idg · failedON PREFLIGHT, NR 1 IDG DRIVE LIGHT NOT ILLUMINATED WITH NR 1 ENGINE NOT RUNNING. ACFT GROUNDED. REPLACED THE NR 1 IDG IAW AMM 24-11-11.SDR ASAA2016041416424Antenna · failedCAPTAIN LOST F/D AND A/P DISENGAGED AT G/S CAPTURE. ACFT GROUNDED. COMPLIED WITH ALL SPECIAL MAINT PROCEDURES, NO DEFECTS NOTED FROM MAINTENANCE PROCEDURES. DFCS FAULT REVIEW SHOWED NUMEROUS RAD ALT 1 FAULTS. REMOVED & REPLACED, AND TESTED NR 1 RAD ALT RXSDR ASAA2016032816115Controller · failedAUTO PRESSURE CONTROLLER FAILED. ACFT GROUNDED. CYCLED CABIN PRESSURIZATION CONTROLLERS 1 & 2, SYSTEM RESET OPS CHECK SATISFACTORY.SDR ASAA2016021615489Nozzle · looseNR 1 ENGINE EXHAUST FLANGE UPPER INBD FWD FENCE FOUND LOOSE HI-LOCK. ACFT GROUNDED. REMOVED LOOSE HI-LOCK AND INSTALLED NEW HI-LOCK FASTENER AT DISCREPANT LOCATION REF SRM 51-40-02.SDR ASAA2016020815339Warning Light · false activationON RECALL LT PACK LIGHT ILLUMINATED. ACFT GROUNDED. NR 1 TEMP CONTROLLER SHOWS RAM AIR ACT FAULT ON BITE TEST ONLY. LAST FLT & VERIFY TESTS PASS. RESET FAULT. FAULT DID NOT RETURN. BITE TEST NR 1 CONTROLLER GOOD. REF AMM 21-62, TASK 837. ACFT GROUND VESDR ASAA2016020215270Compensator · failedFUEL INDICATION DISCREPANCY ON CLIMB WITH FUEL IN CENTER TANK AND ALL FUEL PUMPS ON NOTED RT FUEL QTY DECREASING. DECREASED TO 8120 AND THEN STABILIZED RT FULL NORMAL 8670 AT CRUISE RT TANK DECREASED TO APPROX 8490 AFTER TEN MIN RT TANK DECREASED TO APPROXIMASDR ASAA2015122614444Warning Light · illuminatedCONTROLLER CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED.SDR ASAA2015111513782Control Valve · failedAFTER ENGINE START AND DURING AND AFTER START CHECKLIST MASTER CAUTION RESET, CONT CAB "ZONE TEMP" LIGHT ILLUMINATED. THE "ZONE TEMP" LIGHT EXTINGUISHED UPON MASTER CAUTION RESET. ACFT GROUNDED. HAD "TRIM VALVE FLT DECK" FAULT. R & R V143, TRIM VALVE FOR CONSDR ASAA2015111113729Actuator · faultedLEFT PACK LIGHT ON RECALL. PACK OPERATES NORMALLY. ACFT GROUNDED. NR 1 PACK/ZONE CONTROLLER LOGGED RAM AIR ACT FAULT. REPLACED NR 1 RAM AIR ACTUATOR, REF AMM 21-51-21.SDR ASAA2015110913709Control Valve · failedLEFT PACK LIGHT ON MASTER CAUTION RECALL. ACFT GROUNDED. ZONE TEMP CONTROLLER BITE SHOWED AFT ZONE TEMP CONTROL VALVE HARD FAULT. R & R AND TESTED AFT ZONE TEMP CONTROL VALVE, V145 IAW MM 21-62-01, TEST PASSED.SDR ASAA2015110813687Warning Light · false activationLEFT PACK LIGHT ILLUMINATED UPON RECALL. ACFT GROUNDED. ACCOMPLISHED BITE CHECK ON BOTH TEMP CONTROLLERS REF MM 21-61-00, NO FAULTS FOUND. GROUND VERIFICATION CHECKS NORMAL.SDR ASAA2015092513205Warning Message · false activationFMC DATALINK FULL MESSAGE DISPLAYED ON CDU. GROUNDED - YES. CAPACITY OF TEMPORARY DATA BASE EXCEEDED. DELETE UNNECESSARY TEMPORARY WPTS, NAVAIDS OR AIRPORTS FROM DATA BASE IF THIS ALERT APPEARS REF SDS 34-61-00-044. FLIGHT COMPLETE, TEMP DATA BASE CLEARED.SDR ASAA2015082512907Warning Message · false activationFMC DISAGREE PRIOR TO DEPARTURE. ACFT GROUNDED. QRH PROCEDURE ACCOMPLISHED, NORMAL OPS RESTORED.SDR ASAA2015082512902Warning Light · false activationZONE TEMP CONTROLLER CABIN LIGHT ILLUMINATES ON RECALL, EXTINGUISHES ON RESET. ACFT GROUNDED. NR 2 PACK/ZONE TEMP CONTROLLER LOGGED FLIGHT DECK TRIM VALVE FAULT. RESET FAULT. ACCOMPLISHED NR 2 PACK/ZONE TEMP CONTROLLER BITE CHECK REF MM 21-61-20. TEST PASSEDSDR ASAA2015081512894Warning Light · illuminatedCSS INCOMPLETE APU FAULT LIGHT ILLUMINATED ON 1ST & 2ND ATTEMPTS. 1ST 380 TAT-26, SAT-52 ASA + 5. 2ND 380 TAT -23, SAT -49 ISA +7. ACFT GROUNDED. ON DEFERRAL.SDR ASAA2015081412895Oil System · lowAPU FAILED TO START AT FL 380 WITH FAULT LIGHT. ACFT GROUNDED. FOUND MAINTENANCE LIGHT ON, DETERMINED FAULT WAS LOW OIL QUANTITY. SERVICED APU OIL TO PROPER LEVEL REF AMM CH 12-13-31.SDR ASAA2015081212855Controller · malfunctionedAUTO FAIL AMBER LIGHT ON. ACFT GROUNDED. NR 2 CONTROLLER LOGGED FAULT CODE 101 OVERHEAD PANEL . CYCLED POWER TO ACFT, AUTO FAIL LIGHT EXTINGUISHED. NR 2 AUTO PRESSURE CONTROLLER GROUND VERIFICATION TEST PASSED, REF MM 21-31-00. NO EXISTING FAULTS. NO HIS