N529JB
Service difficulty reports · 134
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N529JB' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N529JB' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YENA201705070331Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN FLOOR STRUCTURE FRAME 67+7, -Y1292. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 53-41-14.SDR YENA201705070330Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN FLOOR STRUCTURE FRAME 66+9, -Y1732. REMOVED & REPLACED THE FLOOR SUPPORT IAW SRM 53-41-14, FIG 001, & 53-00-14-283-002.SDR YENA201705070329Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN FLOOR STRUCTURE FRAME 67+7, -Y1732. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 53-41-14-283-002, AND 53-41-14, FIG 001.SDR YENA201705070328Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN FLOOR STRUCTURE FRAME 65 +18, -Y1732. REMOVED AND REPLACED FLOOR STRUCTURE IAW SRM 51-42-11, AND SRM 53-00-14.SDR YENA201705070327Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON RT FLOOR SUPPORT Y-765, FRAME 18. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 53-42-11-2E.SDR YENA201705070326Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN FLOOR STRUCTURE FRAME 65 +18 ON Y765; AFT CABIN FLOOR STRUCTURE REPLACED ON NR 44014 NR 20557.SDR YENA201705070325Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON -Y81 FLOOR SUPPORT HAS 2 SPOTS OF CORROSION AT FRAMES 16-17. REMOVED AND REPLACED THE FLOOR SUPPORT.SDR YENA201705070324Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON -Y81 FLOORBEAM AT FRAME 17. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 53-11-14 -283-003, AND 51-72-11.SDR YENA201705070323Structure · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT FLOOR STRUCTURE FRAME 66, -Y765. REMOVED AND REPLACED IAW SRM 53-41-14, AND 53-00-14-283-002.SDR YENA201705070322Structure · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN FLOOR STRUCTURE FRAME 67+8 AT -Y765. REMOVED AND REPLACED THE FLOOR STRUCTURE IAW SRM 53-72-11, AND 53-41-14, FIG 001.SDR YENA201705070321Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON THE FLOORBEAM Y254, FRAME 17. REMOVED AND REPLACED IAW SRM 51-72-11, AND 53-11-14-283-001.SDR YENA201612091090Fan · failedCREW REPORTED A BURNING ODOR IN THE COCKPIT.; ACCOMPLISHED ODOR INSPECTION IAW TSM 24-00-00-710-064-A. FOUND THE AVIONICS BLOWER FAN TO BE THE CAUSE OF THE ODOR. R & R THE FAN IAW 21-26-51. PERFORMED OPERATIONAL TEST IAW AMM 21-26-51-710-001. OPS CHECKS PASSSDR YENA20160323251Power Supply · failedFWD EPSU BATTERY FAULT. R & R FWD EPSU BATTERY IAW AMM 33-51-38. OPS CHECKED NORMAL.SDR YENA20150530167Power Supply · failedEMERGENCY EXIT LIGHT BETWEEN RT OVERWING EXIT WAS NOT ILLUMINATED. R & R 12 WL EPSU IAW AMM 33-51-38-PB 401. OPS TEST GOOD.SDR YENA20140912196Wire Harness · damagedDURING MAINTENANCE CHECK, FOUND 23C EMERGENCY LIGHT IN SEAT INOPERATIVE. REPAIRED SEAT HARNESS IAW STANDARD PRACTICES. OPS CHECK GOOD.SDR YENA20140907185Pressure Switch · faultedFLIGHT DIVERTED DUE TO BLUE HYDRAULIC PUMP HAD A LOSS OF PRESSURE. PERFORMED TSM TASK 29-12-00-810A AND FOUND BLUE ELECTRIC PUMP PRESSURE SWITCH FIN 2074GJ AT FAULT. R & R PRESSURE SWITCH IAW AMM 29-12-17. OPS CHECK AND LEAK CHECK OK. FAULT NO LONER IN VIESDR YENA20140410077Warning Message · false indicationCREW DECLARED AN EMERGENCY DUE TO HYD GREEN LOW AIR PRESSURE WARNING DESCENDING THROUGH FL222. COMPLIED W/ECAM. GREEN SYS DID NOT RECOVER. RESULTED IN EMERGENCY GEAR EXTENSION AND ACFT TOW FROM RUNWAY. GREEN SYS HYD PRESSURE NORMAL. GREEN SYS AIR PRESSURE LSDR YENA20140409072Pressure Switch · failedDECLARED AN EMERGENCY AND ACFT RETURNED TO DEPARTURE, FOR A HYD GREEN RESERVOIR LOW AIR PRESSURE ECAM DURING CRUISE. GREEN, ENG 1, PUMP FAULT LIGHT & PTU FAULT LIGHT ON. COMPLIED WITH ECAM OR QRH PROCEDURES. ON DESCENT TURNED ENG 1 PUMP ON TO RESTORE GREEN SYSSDR YENA20130625133Servo Control · failedCREW DECLARED AN EMERGENCY DUE TO WHEEL NWS FAULT IN FLT. RESET NOSE WHEEL STEERING SWITCH ON GROUND UNSUCCESSFUL. R & R NOSE WHEEL SERVO CONTROL IAW AMM 32-51-51. OPS AND LEAK CHECKED OK.SDR YENA20130429089Battery · failedFLT 521 BOS-PBI, WHILE ACCOMPLISHING T/C A320-33-51-00-710-003 BATTERY CAPACITY TEST, EMERGENCY LIGHT BATTERY FAILED THE TEST. REMOVED AND REPLACED ESPU BATTERIES AT 10WL & 11WL IAW 33-51-38-400-002-A. OPS TEST GOOD.SDR YENA20130429088Battery · failedFLT 521 BOS-PBI, WHILE ACCOMPLISHING T/C A320-33-51-00-710-003 BATTERY CAPACITY TEST, EMERGENCY LIGHT BATTERY FAILED THE TEST. REMOVED AND REPLACED ESPU BATTERIES AT 10WL & 11WL IAW 33-51-38-400-002-A. OPS TEST GOOD.SDR YENA20130113013Unknown · malfunctionedFLT 743 MCO-SJU, ON TAXI OUT WITH BOTH ENGINES RUNNING F/A REPORTED ALL EMERGENCY LIGHTS EXIT ILLUMINATED EXCEPT FLOOR PAX LIGHTING. PERFORMED RESET AND TEST OF EMERGENCY LIGHT SYSTEM IAW AMM 33-51-00-05. OPS CHECK NORMAL.SDR YENA20100627090O-Ring · damagedFLT 49 JFK-PBI, CREW DECLARED EMERGENCY LANDING DUE HYD Y ENG 2 PUMP LOW PRESS. THE A/C LOST IT'S YELLOW SYSTEM HYDRAULICS. TECHNICIAN FOUND SHUT OFF VALVE EXTRUDED O-RING AT UNION. REMOVED AND REPLACED O-RING. OPS CHECK NORMAL.SDR YENA200618Seat Track · corrodedON C4 CHECK, CORROSION ON SEAT TRACK LOCATED AT Y1292 BETWEEN FRAME 18 AND FRAME 20 (LEVEL 2 CORROSION). SEAT TRACK WAS REPLACED IAW SRM 51-72-11 AND FASTENERS WERE REMOVED AND INSTALLED IAW SRM 51-42-11 PG 6, BETWEEN FRAME 12 TO FRAME 24 Y1292.SDR YENA200622Seat Track · corrodedON C4 CHECK, CORROSION ON SEAT TRACK LOCATED AT Y765 AT FRAME 20 (LEVEL 2 CORROSION). SEAT TRACK FRAME 16 TO FRAME 24 REPLACED IAW SRM A320 AND PROTECTIVE TREATMENT APPLIED AND FASTENERS INSTALLED IAW SRM A 320 51-41-11.SDR YENA200621Floorbeam · corrodedON C4 CHECK, FLOORBEAM PASS CABIN CORROSION ON HARD POINT Y254 FRAME 68 TO 69 (LEVEL 2 CORROSION). REMOVED AND REPLACED FLOORBEAM PASSENGER CABIN FRAME 68 TO 69 IAW SRM 51-72-11 PAGE 1 TO 2.SDR YENA200620Seat Track · scratchedON C4 CHECK, PASSENGER CABIN SEAT TRACK (6 EA) SCRATCHES AND PROTECTIVE TREATMENT MISSING BETWEEN FRAME 41 TO FRAME 41. REMOVED AND REPLACED SEAT TRACK AT FRAME 41 TO FRAME 47 Y1292 IAW SRM 53-31-15 AND 51-72-11 PG 1-2.SDR YENA200619Floorbeam · corrodedON C4 CHECK, CORROSION ON FLOORBEAM LOCATED AT Y254 BETWEEN FRAME 20 TO FRAME 22 (LEVEL 2 CORROSION). REPLACED FLOORBEAM LOCATED AT Y254 BETWEEN FRAME 12 TO FRAME 24 IAW SRM 51-42-11 PG 1 TO 6. PROTECTIVE TREATMENT APPLIED IAW SRM 51-21-11.SDR YENA200617Dummy Rail · corrodedON C4 CHECK, CORROSION ON DUMMY RAIL Y503.2 BETWEEN FRAME 12 TO FRAME 16 (LEVEL 2 CORROSION). CORROSION REMOVED FROM DUMMY RAIL ON FRAME 12 TO 16 Y503.2 AND FOUND OUT OF LIMITS AND REPLACED WITH A NEW DUMMY RAIL, REF SRM 51-72-11 PG 1 THRU 2.SDR YENA200616Seat Track · scratchedON C4 CHECK, PASSENGER CABIN SEAT TRACK WITH (5 EACH) SCRATCHES AND PROTECTIVE TREATMENT MISSING BETWEEN FRAME 36 TO 41 Y765. SEAT TRACK WITH SCRATCHES OUT OF LIMITS LOCATED BETWEEN FRAME 36 TO FRAME 41 Y765 WAS REPLACED IAW SRM 53-31-15 FIG 3 AND 51-42-11 PGSDR YENA200615Seat Track · scratchedON C4 CHECK, PASSENGER CABIN SEAT TRACK WITH SCRATCH BETWEEN FRAME 35 TO 36 Y-1292. REPLACED SEAT TRACK LOCATED BETWEEN FRAME 35 TO 36 Y1292, REF SRM 51-72-11, PG 1 THRU 2.SDR YENA200614Floorbeam · corrodedON C4 CHECK, PASSENGER CABIN FLOORBEAM WITH CORROSION AT Y1292 AND BETWEEN FRAME 66 TO 67 LOWER HARD POINT (LEVEL 2 CORROSION). FLOORBEAM REPLACED AT Y1292 AND BETWEEN FRAME 64 TO 66+5 IAW SRM 51-72-11 PG 1 THRU 2.SDR YENA200503Electrical Box · faultyBURNING SMELL IN PROXIMITY OF ROWS 7 AND 8. ACCOMPLISHED INFO NOTICE 2004-T023TR SYSTEM OPS CHKD OK. REMOVED AND REPLACED SEB AT 7E AS STATED IN INFO NOTICE AS PRECAUTIONARY.SDR YENA200226Pitot Head · false indicationFLT 62, RSW TO JFK, F/O AIRSPEED INDICATED 0 ON TAKE OFF ROLL, ABORTED T.O AT 80-KTS. PLACED ADR NR 2 ON MEL REF 34-10-01. REMOVED AND REPLACED NR 2 PITOT PROBE AS PER M.M REF 34-11-15-000-001. OPS CHECK OK.
Back to N529JB