N605NK
Service difficulty reports · 83
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N605NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N605NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2019022530380Fault Message · activatedENG 2 EPR MODE FAULT DURING FLIGHT ( CLIMBING THROUGH FL250) ( EPR CONTROL MODES - IAE ENGINES ONLY )-REF LOG ITEMS 246455201 AND LOG ITEM 2464554-2 FOR CORRECTION ACTION. THIS CLEARS DMI #245560001, PLACARD REMOVED.SDR GTIA2019022193170Engine · stalledENGINE 2 ECAM STALL WITH HIGH EGT --SDR GTIA2019022193169A/C Pack · odorOILY SMELL PACK #2 WITH PACL 1 OFF. SWAPPED PACKS, PACK 2 OFF PACK 1 ON . NO SMELL --SDR GTIA2018080202779A/C Pack · odorSTRONG "WET SOCKS SMELL" ODOR AT APPROXIMATELY 10,000FT ON DESCENT IN CABIN, REF TSM 05-50-00-810-825-A RAN ENG 1&2. NO ODOR COMFIRMED. REF AMM 71-00-00. ENG'S INSPECTED FOR VISIBLE SIGNS OF LEAKAGE. NO DEFECTS NOTED. ISOLATED PACK 1&2. PACK 2 APPEARS TO HAVE SDR GTIA2018041902587Unknown · odorFA REPORTED FUMES IN REAR CABIN. FUMES WERE NOTICED JUST PRIOR TO LANDING. A SNIFF CHECK IN THE REAR CABIN BOTH PACKS TURNED OFF AND CHECKED ENGINES, NO LEAKS NOTED IAW TSM 05-50-00-810-831-A, ACFT OK FOR SERVICE.SDR GTIA2018040102555Megaphone · inoperativeFA REPORTED THE MEGAPHONE NOT WORKING. R & R THE MEGAPHONE IAW AMMM 25-65-51.SDR GTIA2018012702367Environ Sys · contaminatedOIL ODOR NOTED IN THE FWD CABIN AREA AT TOP OF DESCENT. PERFORMED DECONTAMINATION OF THE ECS IAW AMM 21-00-00-615-002 AND 21-00-00-615-004. NO ODOR NOTED AFTER DECONTAMINTATION.SDR GTIA2018011802349Megaphone · inoperativeLEAD FLIGHT ATTENDANT REPORTED THE FWD MEGAPHONE APPEARS DEAD. REPLACED MEGAPHONE IAW DWG NK320-232-EQ. OPS CHECKED NORMAL.SDR GTIA2017111202240Megaphone · inoperativeMEGAPHONE INOPERATIVE. R & R THE MEGAPHONE.SDR GTIA2017101902206Door Seal · defectiveR1 DOOR MAKES SQUEALING/HISSING NOISE. REMOVED AND REPLACED DOOR SEAL IAW AMM 52-11-18. LEAKS CHECK GOOD, NO LEAKS NOTED AT THIS TIME.SDR GTIA2017081102149A/C Pack · odorCABIN ODOR REPORTED DURING DECENT BY LEAD FA. PERFORMED DECONTAMINATION OF ECS IAW AMM 21-00-00-615-002 & AMM 21-00-00-615-004. NO CABIN ODOR DETECTED. ACFT OK FOR SERVICE.SDR GTIA2017080302135Pressure Switch · leakingODOR OF DIRTY SOCKS IN FLIGHT DECK DURING DESCENT. UPON INSPECTION FOUND OIL LEAKING FROM APU OIL PRESSURE SWITCH. PERFORMED DECONTAMINATION PROCEDURE OF THE ENVIRONMENTAL CONTROL SYSTEM IAW AMM 21-00-00-615-002-A . NO EVIDENCE OF ANY FURTHER CONTAMINATION ORSDR GTIA2017011601743Unknown · odorDIRTY MUSTY SMELL REPORTED IN AFT GALLEY WHEN LEVELING OFF IN CRUISE. LASTED 40 SECOUNDS. PERFORMED IDENTIFCATION CHECK & CAUSE OF CABIN ODORS/SMELLS IAW TSM 05-50-00-810-831 NO ABNORMAL SMELLS OR CAUSE DETECTED OR NOTED DURING CHECK ALL CHECKS GOOD AT THIS TSDR GTIA2016122601718Oxygen Box · inoperativePRESS TO TEST OXYGEN MASK INOPERATIVE. R & R CAPTAIN`S OXYGEN BOX ASSY IAW AMM 32-12-41-000-001-A\400-001-A, OPS & LEAK CHECKED GOOD.SDR GTIA2016092401604Oxygen Mask · unwanted deployAFT RT LAVATORY OXYGEN MASK FELL OUT. PERFORMED MANUAL MASK DROP IAW AMM 35-23-00. OPS CHECKED GOODSDR GTIA2016090301583Apu · leakingMUSTY DIRTY SOCK ODOR, PACK 1 & APU ALREADY OFF. TURNED OFF NR 1 ENGINE BLEED, ODOR EVENTUALLY STOPPED. TROUBLESHOOTING CARRIED OUT IAW TSM 05-50-00-810-831-A. FOUND APU AND PACK 1 AT FAULT. APU R & R IAW AMM 49-11-11. PERFORMED OPS CHECK, LEAK CHECKS ALLSDR GTIA2015082301626Skin · damagedFOUND ON WALK AROUND DAMAGE TO AFT FUSELAGE AREA FRAME 60-61, STRINGER 19L-20L. THE DENT DIMENSION ARE D=2MM AND A=40MM. REPAIRED IAW EO 5300-1508.SDR GTIA2015022501518Oxygen Mask · unsecureFWD LAV O2 MASKS DROPPED. FOUND AFTER BOARDING COMPLETE. RESECURED FWD LAV O2 MASKS AND PERFORMED DROP TEST IAW AMM 35-23-00. OPS CHECK GOOD AT THIS TIME.SDR GTIA2014070701374Flashlight · inoperativeFWD F/A FLASHLIGHT INOPERATIVE. R & R FWD OTBD EMERGENCY FLASHLIGHT IAW CMM 25-60-13.SDR GTIA2014041501258Battery Pack · inoperativeEMERGENCY FWD CABIN FLASHLIGHTS INOPERATIVE. R & R FLASHLIGHT BATTERIES IAW AMM 25-65-55, OPS CHECKED OK.SDR GTIA2014032001225Bottle · low pressureR2 DOOR ASSIST BOTTLE REQUIRES SERVICING. R-2 DOOR ASSIST BOTTLE SERVICED IAW AMM 52-10-00-614-001.SDR GTIA2014031701219Oxygen Mask · damagedFO OXYGEN MASK MISSING PLASTIC RIVET ON SIDE. R & R F/O OXYGEN MASK IAW AMM 35-12-41. OPS AND LEAK CHECKED OK.SDR GTIA201402221187Transmitter · failedOIL QUANTITY DEGRADED LT ENGINE FROM 20QTS TO 12 QTS THEN DECREASED TO 7 QUARTS, DIVERTED. PERFORMED OIL VISUAL INSPECTION OF OIL TANK FOUND FULL IAW AMM 12-13-79-011-A. CREW PERFORMED ENGINE RUN UP IAW AMM 71-00-00-710-043-A. CHECK FOR LEAKS FOUND OK NO SDR GTIA201401221130Oxygen Mask · brokenCAPTAIN'S OXYGEN MASK INFLATE HOSE BROKEN. REPLACED OXYGEN MASK IAW AMM, TESTED OK.SDR GTIA201312011058Landing Gear · malfunctionedLANDING GEAR DID NOT EXTEND WITH NORMAL EXTENTION. SUCCESSFULLY EXTENDED WITH GRAVITY FEED, IAW TSM 32-31-00-810-808-A. R & R HYDRAULIC CONTROL RELAY (62GA) IAW ESPM 20-46-50. R & R LANDING GEAR SYSTEM ISOLATION VALVE-SAFETY IAW AMM 32-31-34-000-001 AND AMSDR GTIA201311011017Handle · brokenL1 DOOR ASSIST HANDLE BROKEN. R & R L1 DOOR UPPER ASSIST HANDLE IAW AMM.SDR GTIA20130618358Battery · inoperativeEMERGENCY FLASHLIGHT BEHIND F/O SEAT INOPERATIVE. R & R BATTERY IAW AMM.SDR GTIA20130525633Flashlight · inoperativePUSH TO TEST LIGHT INOPERATIVE ON FLASHLIGHT. INSTALLED NEW FLASHLIGHT AT FWD F/A SEAT IAW CMM. OPS CHECKED GOOD.SDR GTIA20130518617Flashlight · unsecureF/A R2 FLASHLIGHT INOPERATIVE. RESEATED FLASHLIGHT INTO HOLSTER AND OPS CHECKED GOOD IAW CMM. OK FOR SERVICE.SDR GTIA20130401622Container · tornFWD GALLEY SPARE O2 MASK BAG IS TORN. PERFORMED GVI OF FWD GALLEY POB MASK CONTAINERS FOUND NO VISIBLE DAMAGE IAW MM.SDR GTIA20130302569Battery Pack · inoperativeEPSU TEST SHOWS NS SW (190RT)/ EPSU(11WL) EMERGENCY LT FAULT. R & R BATTERY OF EMERGENCY POWER SUPPLY UNIT. OPS CHECKED OK. NO OTHER DEFECTS NOTED.SDR GTIA20121221546Flashlight · no testR2 FLASHLIGHT WILL NOT TEST. R & R R2 FLASHLIGHT ASSY IAW MM. OPS CHECKED GOOD.SDR GTIA20120823476Reservoir · lowLEFT AFT WINDOW EXIT SHOWED CHECK SLIDE PRESSURE. R & R LEFT AFT RESERVOIR IAW AMM 25-62-46-000-001-A/400-001-A.