What was found
LANDING GEAR DID NOT EXTEND WITH NORMAL EXTENTION. SUCCESSFULLY EXTENDED WITH GRAVITY FEED, IAW TSM 32-31-00-810-808-A. R & R HYDRAULIC CONTROL RELAY (62GA) IAW ESPM 20-46-50. R & R LANDING GEAR SYSTEM ISOLATION VALVE-SAFETY IAW AMM 32-31-34-000-001 AND AMM 32-31-17-400-001. R & R LANDING GEAR NORMAL CONTROL LEVER IAW AMM 32-31-11, PB 401 CONF 00. ACCOMPLISHED FUNCTIONAL TEST OF THE NORMAL EXTENSION AND RETRACTION OF THE LANDING GEAR IAW AMM 32-31-00-720-002-A. FUNCTIONAL TEST PASSED. NO FURTHER DEFECTS NOTED. LANDING GEAR EXTENSION AND RETRACTION OPS CK GOOD.