N614QX
Service difficulty reports · 465
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N614QX' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N614QX' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA2013022803081Megaphone · unknownF/A MEGAPHONE INOPERATIVE. PERFORMED OPS CHECK OF MEGAPHONE IAW AMM25-61-14. OPS CHECKED GOOD AT THIS TIME NO FURTHER DEFECTS NOTED AT THIS TIME.SDR ASOA2012071201889Battery Pack · dischargedON 1ST FLT CHECK, FOUND EMERGENCY LIGHTS INOPERATIVE. RECHARGED EMERGENCY LIGHT BATTERY PACK, PERFORMED OPS CHECK IAW AMM 35-51-01, OPS CHECKED GOOD,SDR ASOA2012062901845Battery Pack · dischargedEMERGENCY LIGHTS IN GALLEY LIFT IN ON POSITION CAUSING EMERGENCY LIGHTS TO NOT FUNCTION FOR FIRST FLIGHT. RECHARGED CABIN EMERGENCY BATTERY PACK, OPS CHECKED GOOD, NO DEFECT NOTED, IAW AMM 33-51-01.SDR ASOA201201249Seat Track · corrodedRIGHT SIDEWALL SEAT TRACK AT FS 863 TO FS 785.15 HAS CORROSION. REMOVED CORROSION IAW SRM 51-21-06-001-001-A01. FOUND TO BE OUT OF LIMITS IAW SRM 53-41-19-101-001-A01 AND 53-51-19-101-001-A01. R & R SIDE SEAT TRACK IAW AMM 53-00-49-400-801-A02.SDR ASOA201201247Floor Support · crackedDURING REMOVAL OF THE BS 280.00 CROSSBEAM REPLACEMENT, FOUND COCKPIT FLOOR SUPPORT LAND CRACKED. INSTALLED FLOOR SUPPORT ANGLE IAW SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01.SDR ASOA201201313Floorbeam · damagedON REMOVAL OF RT 280 FLOORBEAM, FOUND 1 HOLE ROUTED OUT AT FLOOR SILL AT 280. REPAIRED IAW REO 670-53-21-139.SDR ASOA201201245Attach Fitting · corrodedFOUR 90 DEGREE ATTACH ANGLE AT ENDS OF DOOR FRAMES AT BOTTOM OF DOOR CORRODED FWD FRAME, FS 320.1, AFT FS 388. INSTALLED ATTACH ANGLES IAW SRM 51-42-06-001-001-A01.SDR ASOA201201241Vertical Support · crackedVERTICAL ANGLE FS 280.00 AT BL 26.00 CRACKED. INSTALLED SERVICABLE ANGLE IAW AMM SRM 51-42-06-001-001-A01.SDR ASOA201201239Web · corrodedLEFT BS 280 WEB CORRODED. FOUND TO BE OUT OF LIMITS IAW 53-11-10-201-003-A01. REPAIRED IAW REO 670-53-11-594.SDR ASOA201201320Riser · crackedASD FWD RISER CRACKED LOWER CORNER. REMOVED RISER DRAG ANGLE SUPPORT ANGLES UPPER RAIL & BOX FITTING & NUT PLATES IAW SRM 51-42-06-001-001-A01. LOCATED NEW RISER ON FWD ASD DRILLED UP RISER FOR THE DRAG ANGLE SUPPORT ANGLES UPPER RAIL BOX FITTING & NUT PLATESDR ASOA201201217Seat Track · corrodedRIGHT SIDE WALL SEAT TRACK AT FS 469 TO 565 HAS CORROSION. REMOVED CORROSION IAW SRM 51-21-06-001-001. FOUND TO BE OUT OF LIMITS FOR SRM 53-31-490991-804. R & R DAMAGED SEAT TRACK IAW AMM 53-00-49-000-801.SDR ASOA201201215Seat Track · corrodedRIGHT SIDE WALL SEAT TRACK AT FS 677 TO 693 CORRODED. REMOVED CORROSION IAW SRM 51-12-00-001-001. FOUND TO BE WITHIN LIMITS IAW SRM 53-31-49-101-001-A01.SDR ASOA201201213Seat Track · corrodedRIGHT SIDE WALL SEAT TRACK AT FS 581 TO 661 CORRODED. REMOVED DAMAGE FROM SEAT TRACK IAW SRM 51-21-06-001-001. FOUND TO BE WITHIN LIMITS IAW SRM 53-31-49-101-001-A01.SDR ASOA201201211Seat Track · damagedLT SIDE WALL SEAT TRACK AT APROX FS 469 - 565 CHAFED AND CORRODED. FOUND TO BE WITHIN LIMITS IAW SRM 53-31-49-101-001-A01.SDR ASOA201201209Seat Track · damagedLEFT SIDE WALL SEAT TRACK AT FS 661 TO 752 CHAFED AND CORRODED. FOUND SEAT TRACK TO BE OUT OF LIMITS IAW SRM 53-41-49-101-001-A01. REMOVED DAMAGED SEAT TRACK IAW AMM 53-00-49-000-801. INSTALLED NEW SEAT TRACK IAW AMM 53-00-49-400-801.SDR ASOA201201207Angle · crackedASD LOWER STEP NUTPLATE ANGLE CRACKED AT WD SECTION. INSTALLED NEW ANGLE IAW SRM 51-42-13-001-001-A01, 52-42-15-001-001-A01SDR ASOA201201182Seat Track · corrodedRBL 9 SEAT TRACK CORRODED FROM FS 597 TO 677. REMOVED CORROSION AND FOUND WITHIN ALLOWABLE LIMITS IAW SRM 53-41-49.SDR ASOA201201180Seat Track · corrodedRBL 9.00 SEAT TRACK CORRODED AT FS 693. REMOVED CORROSION IAW SRM 51-21-06 AND FOUND TO BE WITHIN LIMITS IAW SRM 53-41-49, FIG 53-41-49-991-804.SDR ASOA201201178Seat Track · corrodedRBL 9.00 SEAT TRACK CORRODED FROM FS 847 TO 939. SEAT TRACK IS WITHIN ALLOWABLE LIMITS IAW SRM 53-41-49.SDR ASOA201201176Seat Track · corrodedLBL 9.00 SEAT TRACK CORRODED FROM FS 863 TO 969. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-51-49-101-001-A01. REMOVED CORRODED SEAT TRACK AND INSTALLED NEW SEAT TRACK IAW AMM 53-11-49-000-801(A01) AND 53-00-49-400-801(A02).SDR ASOA201201174Seat Track · corrodedLBL 9 SEAT TRACK CORRODED AT FS 693. REMOVED CORROSION FROM SEAT TRACK, FOUND TO BE WITHIN ALLOWABLE LIMITS IAW SRM 53-41-49.SDR ASOA201201172Seat Track · corrodedLBL 9 SEAT TRACK CORRODED FROM FS 597 TO 677. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-31-49-101-001-A01. R & R SEAT TRACK IAW AMM 53-00-49-000-801 AND 53-00-49-400-801.SDR ASOA201201170Seat Track · corrodedLBL 9 SEAT TRACK CORRODED FROM FS 485 TO 581. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-31-49-101-001-A01. REMOVED CORRODED SEAT TRACK AND INSTALLED NEW SEAT TRACK IAW AMM 53-00-49-000-801 (A02) AND 53-00-49-400-801.SDR ASOA201201168Seat Track · corrodedRBL 9 SEAT TRACK CORRODED FROM FS 485 TO 565. SEAT TRACK FOUND TO BE CORRODED BEYOND ALLOWABLE DAMAGE IAW SRM 53-41-49. R & R WITH SERVICEABLE SEAT TRACK IAW AMM 53-00-49-000-801 AND 53-00-49-400-801.SDR ASOA201201166Seat Track · corrodedLBL 9 SEAT TRACK CORRODED FROM FS 364 TO 565. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-21-49-101-001-A01. R & R CORRODED SEAT TRACK IAW AMM 53-00-49-000-801 AND 53-00-49-400-801.SDR ASOA201201164Seat Track · corrodedRBL 9 SEAT TRACK CORRODED FROM 349 TO 409. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-21-49-101-001. REMOVED CORRODED SEAT TRACK AND INSTALLED NEW SEAT TRACK IAW AMM 53-00-49-000-801(A02) AND 53-00-49-400-801(A02).SDR ASOA201201131Angle · corrodedANGLE AT S5-19R, FS 1015 HAS CORROSION. REMOVED CORRODED ANGLE IAW SRM 51-42-06-001-001-A01. INSTALLED NEW ANGLE SRM 51-42-06-001-001A-01.SDR ASOA201201129Floorbeam · corrodedFS 280 CROSSBEAM CORRODED. REPAIRED IAW REO 670-53-11-697.SDR ASOA201201127Floor Panel · crackedFWD EQUIPMENT BAY FLOOR CRACKED ON LT SIDE JUST OTBD OF BRAKE ACCUMALATOR GAUGES. COMPLIED WITH REO 670-53-11-509 AND REO 670-53-11-509 REV.SDR ASOA201201125Floor Panel · crackedFWD EQUIPMENT FLOOR CRACKED ON RT SIDE NEXT TO ADG PUMP. COMPLIED WITH REO 670-53-11-509 AND REO 670-53-11-509 REV.SDR ASOA201201123Floorbeam · crackedFS 280, RBL 9 FLOORBEAM CRACKED. REPAIRED.SDR ASOA201201121Floor Support · crackedFS 280, LBL 9 FLOORBEAM CRACKED. REPAIRED.SDR ASOA201201064Glowstrip · missingFLOOR LEVEL GLOW STRIP IS MISSING IN FRONT OF WARDROBE CLOSET. INSTALLED MISSING GLOW STRIP IAW AMM 33-51-00. ACFT OK FOR SERVICE.SDR ASOA201200246Unknown · odorELECTRICAL BURNING ODOR COMING FROM ROW 16D. SIDE PANEL WAS WARM TO THE TOUCH. INSPECTED ACFT WIRING ROW 16D IAW ESPM 20-12-00, NO FAULTS FOUND.SDR ASOA201102044Megaphone · inoperativeAFT MEGAPHONE INOPERATIVE. R & R AFT MEGAPHONE IAW AMM 25-65-14. OPS CHECKED GOOD.SDR ASOA201101861Lamp · burned outCABIN CEILING EMERGENCY LIGHT THIRD FROM FRONT INOP. RELAMPED CABIN NR3 CEILING EMERGENCY LIGHT IAW AMM 33-51-09. OPS CHECK GOOD.SDR ASOA201101481Selector Valve · inoperativeRECEIVE GEAR DISAGREE WARNING MSG AFTER SELECTING GEAR DOWN NO INDICATION OF GEAR CYCLE PERFORM GEAR DISAGREE QHR PROCEDURE AND EMERGENCY GEAR EXTENSION LANDED AFTER OBTAINING 3 GREEN. (EMERGENCY DECLARED AS A PRECAUTION). R & R LANDING GEAR SELECTOR VALVE IASDR ASOA201101405Lamp · burned outNR4 INTERIOR CEILING EMERGENCY LIGHT INOP. RELAMPED NR4 INTERIOR CEILING EMERGENCY LIGHT AS REQUIRED. OPS CHECKED GOOD IAW AMM 33-51-00. RELAMPED NR4 INTERIOR CEILING EMERGENCY LIGHT AS REQUIRED. OPS CK GOOD IAW AMM 33-51-00.SDR ASOA201101348Light · intermittentEMERGENCY LIGHTS CYCLE ON AND OFF WHEN IN THE ARM POS. R & R ALL 4 EMERGENCY BATTERY PACK IAW AMM 33-51-17. NO HELP.SDR ASOA201101311Megaphone · inoperativeMEGAPHONE INOP. R & R MEGAPHONE IAW AMM 25-61-14. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED AT THIS TIME. (CLOSED)SDR ASOA201100765Seat Track · corrodedFS 708 RT SIDEWALL SEAT TRACK HAS CORROSION BEYOND SRM LIMITS. REMOVED SEAT TRACK IAW TASK 53-00-49-000-801. INSTALLED NEW TRACK IAW TASK 53-00-49-400-801.SDR ASOA201100764Seat Track · corrodedFS 581 RT SIDEWALL SEAT TRACK HAS CORROSION BEYOND SRM LIMITS . REMOVED SEAT TRACK IAW AMM 53-00-49-400-800. INSTALLED NEW TRACK IAW AMM 53-00-49-400-801.SDR ASOA201100763Seat Track · corrodedFS 420 RT SIDEWALL SEAT TRACK HAS CORROSION BEYOND SRM LIMITS. REMOVED SEAT TRACK IAW AMM 53-00-49-000-801. INSTALLED NEW SEAT TRACK IAW AMM 53-00-49-400-801.SDR ASOA201100771Seat Track · corrodedREF NR 2534N00020, CUSTOMER REQUEST CORROSION ON RT SIDEWALL SEAT TRACK, FS 420 AND 490. DURING EVALUATION, DETERMINED THE CORROSION TO BE BEYOND ALLOWABLE LIMITS IAW SRM 53-21-49.SDR ASOA201100759Seat Track · corrodedCORROSION ON RT SIDEWALL SEAT TRACK, AT SEAT POSITIONS 7CD AND 11CD. DETERMINED THE CORROSION TO BE BEYOND ALLOWABLE LIMITS IAW SRM 53-31-49.SDR QXEA2011013100114Floor Panel · crackedDURING NDT INSPECTION, FOUND ONE CRACK INDICATION, APPROX .5" LONG ON THE PRESSURE FLOOR, LT SIDE, AT FS 810 BETWEEN LBL9 AND LBL18. MAPPED CRACK AND VERFIED. REPAIRED AREA IAW REO 670-53-41-125/3.SDR QXEA2011012400073Ballast · overheatedNOTICED ELECTRICAL ODOR IN ROW 6-7 OVERHEAD BIN AREA DURING CABIN WALK-THRU. INSPECTED, FOUND BALLAST IN OVERHEAD BIN FOR CEILING LIGHT AT ROW 6-7 ED OVERHEATED. REMOVED BALLAST IAW AMM TASK 33-23-00-000-801, INSTALLED NEW BALLAST FROM STOCK IAW AMM TASK 33-2SDR QXEA2010081200481Fan · failedDISPLAY COOL CAUTION AFTER T/O, RETURN TO FIELD. LANDING UNEVENTFUL. REPLACED NR 1 DISPLAY SUPPLY FAN AND CHECK VALVE IAW AMM TASKS 21-24-12-000-801 & 21-24-12-400-801, OPS CHECK GOOD. RETURNED TO SERVICE.SDR QXEA2010041500271Angle · corrodedC CHECK - PAX DOOR MIDCAP ANGLE HAS CORROSION ON IT. REMOVED PAX DOOR MIDCAP ANGLE IAW SRM 51-41-02-001-001-A01. RECEIVED NEW MIDCAP ANGLE AND LOCATED NEW HOLES IAW SRM 51-40-11-001-001-A01. INSTALLED NEW MIDCAP ANGLE IAW SRM 51-41-00-001-001-A01. APPLIEDSDR QXEA2010041500270Angle · corrodedC CHECK - SERVICE DOOR MOUNTING ANGLE HAS CORROSION ON IT. REMOVED CORROSION FROM MOUNTING ANGLE ON SILL IAW SRM 51-21-06-001-001, FOUND BLEND TO BE OUT OF LIMITS IAW SRM 51-12-00-001-001 AND 53-21-23-101-002-A01. REMOVED MOUNTING ANGLE AND LOCATED FASTENE
Back to N614QX