What was found
C CHECK - SERVICE DOOR MOUNTING ANGLE HAS CORROSION ON IT. REMOVED CORROSION FROM MOUNTING ANGLE ON SILL IAW SRM 51-21-06-001-001, FOUND BLEND TO BE OUT OF LIMITS IAW SRM 51-12-00-001-001 AND 53-21-23-101-002-A01. REMOVED MOUNTING ANGLE AND LOCATED FASTENER HOLES IN NEW ANGLE IAW SRM 51-42-06-001-001-A01. TREATED AND PRIMED HOLES IAW SRM 51-21-11-001-001-A01. INSTALLED NEW MOUNTING ANGLE IAW SRM 51-42-06-001-001-A01.