N618AE
Service difficulty reports · 178
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N618AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N618AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA201811165003Light · inoperativeNO ORANGE EMERGENCY LIGHT SECTION BESIDE WINDOW EXIT ROWS PER FA-C/A-REMOVED AND REPLACED EMER. EXIT ROW FLOOR FLIGHTING STRIP AND OPC GOOD IAW EMB145 AMM 33-50-12 AND 33-50-00.SDR RAIA201807150001Indication Sys · intermittentTANK 1 FUEL INDICATION READING ERRONEOUS FUEL LOAD INTERMITTENT. FUEL INDICATION DEFERRED ON DMI 2840001. WILL SEND MORE INFORMATION WHEN AVAIABLESDR RAIA2018041901Bulb · inoperativeRIGHT AFT OVERWING EMERGENCY LIGHT NR 6 IS INOPERATIVE. R & R THE BULB. OPS CHECKED GOOD.SDR RAIA201712060001Skin · crackedCARGO DOOR SKIN CRACKED AT UPPER AFT CORNER OF DOOR HANDLE CUTOUT. INSTALLED A FILLER AND DOUBLER.SDR RAIA201712050001Skin · damagedREAR FUSELAGE EXTERNAL SKIN DENTED AND SCRATCH BETWEEN FRAMES 72 - 73, STRINGERS 10R-13R. FABRICATED AND INSTALLED A STRAP AND REPAIR PARTS.SDR RAIA201608150001Pump · leakingNR 2 HYDRAULIC SYS FLUID LOW. SERVICED THE NR 2 HYDRAULIC SYS AND R & R THE NR 2 ENGINE HYD PUMP. OPS LEAK CHECKED GOOD.SDR RAIA201602290003Coupling · wornBLEED 2 LEAK EICAS MESSAGE IN FLIGHT. FOUND NR 2 ENGINE BLEED VALVE OUTLET COUPLING BAD, R & R BLEED COUPLING. OPS CHECK GOOD. INSPECTED BLEED DUCTS NO LEAKS NOTED.SDR RAIA201602020004Pressure Switch · inoperativeBLEED 2 CLOSED EICAS MSG. R & R NR 1 HIGH STAGE PRESSURE SWITCH. OPS CHECK GOOD.SDR SIMA20150901001Floor Support · crackedGALLEY FLOOR SUPPORT FWD DIGITAL CRACKED. REPAIRED FWD DIGITAL CRACK IAW ERS-EM-53MR-1584.SDR SIMA20150831004Skin · crackedRIGHT REAR FUSELAGE I SKIN CRACKS AT FRAME 75, BETWEEN STRINGERS 2R & 3R. PERFORMED PERMANENT REPAIR OF RT REAR FUSELAGE I SKIN AT FRAME 75, BETWEEN STRINGERS 2R & 3R IAW ERS-EM-53MR-1588.SDR SIMA20150831003Skin · crackedLEFT REAR FUSELAGE I SKIN CRACKS AT FRAME 75, BETWEEN STRINGERS 1L & 3L. PERFORMED PERMANENT REPAIR OF LT REAR FUSELAGE I SKIN AT FRAME 75 BETWEEN STRINGERS 1L & 3L IAW ERS-EM-53MR-1587.SDR SIMA20150829001Stringer · gougedSTRINGER 18L AT FRAME 71 GOUGED. PERFORMED PERMANENT REPAIR OF STRINGER 18L AT FRAME 71 IAW SRM 53-00-03-RE.SDR SIMA20150827005Wire · brokenEMERGENCY LIGHT STRIP HARNESS, BROKEN WIRE UNDER FLOOR PANEL 231GF. REPAIRED LIGHT STRIP FLOOR PROXIMITY LIGHT WIRES UNDER PANEL 231GF IAW SWPM 20-21-00. FOUND DURING OPEN UP.SDR SIMA20150827004Wire · brokenFOUND NR 2 FLOOR PROXIMITY LIGHT AT 241DF WIRES BROKEN. REPAIRED NR 2 FLOOR PROXIMITY LIGHT WIRES IAW SWPM 20-21-00. FOUND DURING OPEN UP.SDR SIMA20150826002Frame · corrodedFRAME 65 CORRODED AROUND LOWER STRIKER PLATE. REPAIRED FRAME 65 BETWEEN STRINGERS 16L & 17L IAW ERS-EM-53MR-1577.SDR SIMA20150826003Door Frame · crackedCARGO DOOR FWD PROFILE LOWER NUTPLATE HOLE CORRODED & CRACKED. REPAIRED IAW ERS-EM-52MR-414.SDR SIMA20150821001Yoke · crackedLEFT ENG FWD, LOWER YOKE CRACKED BEHIND ENG MOUNT. R & R LT ENG LOWER FWD YOKE IAW EO EM-54MR-386.SDR SIMA20150809009Skin · crackedLEFT UPPER FUSELAGE SKIN CRACKED JUST AFT OF FRAME 75 & ABOVE STRINGER 2L, CRACK IS APPROX. 3/8" LONG. REPAIRED LT UPPER FUSELAGE SKIN JUST AFT OF FRAME 75 & ABOVE STRINGER 2L IAW ERS-EM-53MR-1587.SDR SIMA20150809010Profile · corrodedCARGO DOOR FWD PROFILE LOWER NUTPLATE HOLE CORRODED. REPAIRED CORRODED NUTPLATE HOLE ON CARGO DOOR FWD PROFILE LOWER IAW ERS-EM-52MR-414.SDR SIMA20150809007Door Frame · crackedCARGO DOOR FWD FRAME IS CRACKED UNDERNEATH LOWER GUIDE. REPAIRED CARGO DOOR FWD FRAME CRACKED UNDERNEATH LOWER GUIDE IAW ERS-EM-52MR-414. SEE NRTC TURNOVERS FOR DETAILS.SDR SIMA20150809008Wire · brokenEMERGENCY LIGHT STRIP WIRES AT 251 DF ARE BROKEN. INSTALLED CONNECTOR ON BROKEN EMER LIGHT STRIP WIRES AT 251 DF IAW SWPM 20-00-03 & 20-21-00. TOOL SN6277, SEE NRTC BOW 199115 FOR THE OPERATIONAL TEST OF THE EMER LIGHT STRIP AT 251 DF.SDR SIMA20150521002Inverter · inoperativeRIGHT EMER EXIT, AFT EXIT MARKER LIGHT FAILED TO ILLUMINATE. R & R NR 5 EMER LIGHT INVERTER. OPERATIONS CHECKED GOOD IAW AMM 33-50-11.SDR SIMA20150519002Flashlight · inoperativeCAPTAINS SIDE FLASHLIGHT INOPERATIVE. R & R FLASHLIGHT IAW AMM 33-50-16. OPERATIONS CHECKED GOOD.SDR SIMA20150508001Flashlight · brokenREAR CABIN FLASHLIGHT CLIP BROKEN. R & R REAR CABIN FLASHLIGHT ASSEMBLY IAW AMM 33-50-16. OPERATIONS CHECKED GOOD, NO DEFECTS NOTED.SDR SIMA20150407003Light · inoperativeCENTER AISLE OVERHEAD EMER LIGHT AT ROW 7 INOPERATIVE. R & R CTR AISLE OVERHEAD EMER LAMP AT ROW 7 IAW TASK 33-50-08-000-801-A & TASK 33-50-08-400-801-A. OPERATIONS CHECKED GOOD.SDR SIMA20150316002Pin · malfunctionedDURING CLIMB, CREW HEARD A SQUEAL & NOTED THE PIN ON THE DV WINDOW MOVE FROM FLUSH TO THE PROTRUDING POSITION. RETURNED WITHOUT INCIDENT. OPS TESTED THE DV WINDOW IAW AMM 56-11-01. TESTED SATISFACTORILY.SDR SIMA20150131001Warning System · false activationNUMBER 1 BLEED LEAK ILLUMINATED ON CLIMB OUT ON EICAS & NR 1 ENG BLEED SWITCH. SECURED NR 1 ENG BLEED SWITCH & ANNUNCIATION EXTINGUISHED, HAPPENED DURING CLIMB OUT JUST AFTER ANTI-ICE SYS TURNED OFF. INSPECTED DUCTS & JOINTS IN THE NR 1 BLEED SYS IAW ETN-EM-SDR SIMA20150113004Unknown · odorSTRONG ELEC BURNING SMELL IN COCKPIT. PERFORMED GVI OF COCKPIT & ELEC PANELS & FWD E BAY, NO DEFECTS NOTED. NO EVIDENCE OF ELEC FAULTS.SDR SIMA20141208002Uplock · failedAFTER TAKEOFF WITH GEAR UP, FELT A THUMPING UNDER THE ACFT. DECLARED AN EMERGENCY & RETURNED TO DEPARTURE. THE THUMPING CONTINUED UNTIL GEAR WAS DOWN. REPLACED RT MLG UPLOCK BOX IAW MM 32-33-10. OPS & LEAK CHECKED GOOD.SDR SIMA20141203005Power Supply · inoperativeBOTH AFT OVERWING EMER LIGHTS INOPERATIVE. R & R NR 4 EMER LIGHT POWER SUPPLY & BATTERY IAW WC 33-700-19. OPERATIONAL CHECK GOOD. EMER LIGHTING BATTERY PN 2013-1A SN 67262.SDR SIMA20141129008Battery · dischargedEXTERIOR OVERWING EMER LIGHTS INOPERATIVE. R & R OVERWING EMER LIGHT BATTERY & CHARGER ASSEMBLY NR 4 IAW AMM 33-05-04. OPERATIONS CHECKED GOOD. BATTERY CHARGER ASSEMBLY PN 11-0049 & SN 15847.SDR SIMA20141101002Flashlight · odorSTRONG ELEC SMELL IN COCKPIT AFTER LANDING & TOWARDS FRONT OF CABIN. FOUND CAPTAIN`S FLASHLIGHT TO HAVE BURNT SMELL. R & R FLASHLIGHT & FLASHLIGHT HOLDER IAW AMM 33-50-16.SDR SIMA20141027005Support · brokenEXCESSIVE RESISTANCE ON YOLK WHEN PULLED AFT, LAST 1/3. TRANSFERRED TO NRWC 618-DFW-02203. IAW TO NRWC 618-DFW-02205 FOUND AILERON SUPPORT BROKEN & SUPPORT SEMI GROMMET DAMAGED AT STATION 5418.0 & 5833.0 IAW NRWC 618-DFW-02206. PERFORMED ELEVATOR CONTROL CASDR SIMA20140825004Structure · leakingFLUID LEAKING & STREAMING OVER RT FLAPS INFLIGHT. TRANSFER TO NRWC 618-SGF-02120, ITEM 1. FOUND LEAK ON RT WING SEAM BETWEEN ACCESS PANEL 641AB-631DB. RESEALED SEAMS AS REQUIRED. LEAK CHECKED GOOD IAW AMM 28-11-01.SDR SIMA20140721002Duct · leakingCLIMBING THROUGH 6000 FT, NR 1 BLEED LEAK EICAS MESSAGE PRESENTED. COMPLETED EPC & AOM 1 PROCEDURES. MESSAGE TOOK ABOUT 2 1/2 MINUTES TO CLEAR, BUT CLEARED. DIVERTED & RETURNED. REMOVED AND REPLACED LT PACK VALVE AND Y-DUCT IAW AMM 21-51-01 AND FLEX DUCSDR SIMA20140720004Heater · unknownNR 1 WINDSHIELD HEAT FAILED IN FLIGHT. REMAINED AFTER AOM VOL 1 PROCEDURE COMPLETED. PERFORMED OPS CHECK OF WINDSHIELD HEATING SYS IAW AMM 30-42-00. OPS CHECKED GOOD.SDR SIMA20140720002O-Ring · damagedBLD 1 LEAK INDICATION ON EICAS DURING EN ROUTE CLIMB THRU 10000 MSC RAN A011 CHECK LIST BLD LEAK INDICATION EXTINGUISHED AFTER APPROX 3 MINUTES. R & R ORING IAW ETN EM 36-048 ON BLD DUCT LOCATION 28, 17, 15, 9 & 7 IAW AMM 36-11-09. GND RAN OPERATIONS CHECK NSDR SIMA20140611001Roller · lack of lubeFLIGHT ATTENDANT REPORTS MAIN CABIN DOOR DIFFICULT TO OPEN & CLOSE. LUBRICATED MAIN DOOR FRAME ROLLER & CHECKED OK IAW MM 53-21-02.SDR SIMA20140519005Light · missingEMERGENCY FLOOR PROXIMITY LIGHTING STRIP AT ROWS 17 & 18 DISCOVERED TO BE NOT ON ACFT. LOCATION UNKNOWN. DISCOVERED LOCATION OF ROW 17 & 18 EMERGENCY FLOOR PROXIMITY LIGHTING STRIP. INSTALLED EMERGENCY LIGHTING STRIP IAW AMM 33-50-12. OPERATIONAL CHECK GOODSDR SIMA20140515004Charger · inoperativeEMERGENCY LIGHT STRIP & RT & LT OVERWING LIGHTS INOPERATIVE. R & R NR 4 BATTERY CHARGER & THE BATTERY IAW AMM 33-50-04. OPERATIONS CHECKED GOOD AT THIS TIME.SDR SIMA20140319008Proximity Switch · failedUPON LG RETRACTION DEPARTING DFW HAD LG AIR & GND FAIL MSG ON EICAS. R & R LT MLG WOW 1 & WOW 2 PROX SWITCHES & RT MLG WOW 1 PROX SWITCH IAW AMM 32-63-01. FUNCTION CHECK GOOD IAW AMM 32-63-05.SDR SIMA20140306005Proximity Sensor · failedLG AIR, GND FAIL MESSAGE ON EICAS AFTER GEAR RETRACTION. R & R RT MLG WOW NR 1 SWITCH & LT MLG WOW NR 1 SWITCH IAW AMM 32-63-01. ADJUSTED THE TARGET ON LT MLG WOW NR 2 SWITCH IAW AMM 32-63-05. OPERATIONS CHECKED GOOD IAW AMM 32-63-00.SDR SIMA20140228011Pressure Switch · defectiveRUDDER SYS 2 INOPERATIVE, CAUTION AFTER LIFTOFF. R & R RT PRESS SWITCH PO 378, OPERATIONS CHECKED GOOD IAW MM 27-23-00. NO DEFECTS NOTED AT THIS TIME.SDR SIMA20140113004Flashlight · inoperativeCAPTAIN`S FLASHLIGHT INOPERATIVE. AFT FLIGHT ATTENDANT`S FLASHLIGHT USED IN ITS PLACE. CREW PLACARDED IAW MEL 2553 AUTH 010724-C MOC 686519.SDR SIMA20131031004Frame · chafedFRAME 15 CHAFED AT STRINGER 2R. REPAIRED FRAME IAW EO-EM-53MR-2225.SDR SIMA20131028005Strap · chafedCHAFED REINFORCEMENT STRAP OF FR 54 BETWEEN STR 9R AND 11R. PERFORMED CUTOUT OF DAMAGES AND FABRICATED FILERS, STRAP AND PREP IAW EO EM-53MR-2226.SDR SIMA20131028006Spar · crackedCRACK ON LT SPAR 3 AROUND HARNESS CUT OUT HOLE. PERFORMED REPAIR IAW EO EM-57MR-727.SDR SIMA20131010006Wire · brokenEMERGENCY LIGHT AT ROW 9 HAS A BROKEN WIRE. INSTALLED SERVICEABLE SPLICE AND PIN ON EMERGENCY LIGHT STRIP WIRE AT ROW 9 IAW SWPM 20-21-00 AND 20-50-01.SDR SIMA20130927002Flashlight · missingAFT FLASHLIGHT MISSING. INSTALLED FLASHLIGHT IAW AMM 33-50-16. OPS GOOD.SDR SIMA20130903024Rmu · inoperativeCREW REPORTED AFTER TAKEOFF, RMU 1 DISPLAYED ALL DASHES EXCEPT COMM 1 WINDOW. RMU 2 DISPLAYED ALL DASHES. 115 VAC BUSS OFF ILLUMINATED FOR APPROX 30 SECONDS AND THEN EXTINGUISHED. DECLARED AN EMERGENCY AND RETURNED TO DEPARTURE. LANDED WITHOUT INCIDENT.