What was found
EXCESSIVE RESISTANCE ON YOLK WHEN PULLED AFT, LAST 1/3. TRANSFERRED TO NRWC 618-DFW-02203. IAW TO NRWC 618-DFW-02205 FOUND AILERON SUPPORT BROKEN & SUPPORT SEMI GROMMET DAMAGED AT STATION 5418.0 & 5833.0 IAW NRWC 618-DFW-02206. PERFORMED ELEVATOR CONTROL CABLE TENSION CHECK. SYS OPERATIONS CHECKED GOOD.