N619AE
Service difficulty reports · 165
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N619AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N619AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20221114001Cradle · brokenFWD F/A'S EMERGENCY FLASHLIGHT HOLDER BROKEN-C/A-RAR F/A'S FLASHLIGHT BRACKET CLAMP FINGER IAW AMM 33-50-16. OPC GOOD.SDR SIMA20221025001Lamp · inoperativeAFT CEILING LINING EMERGENCY LIGHT INOP-C/A-RAR AFT CEILING EMERGENCY LIGHT LAMP IAW EMB 145 AMM 33-50-08-000-801-A AND 33-50-08-400-801-A. OPC GOOD. END.SDR SIMA20221021003Lamp · inoperativeSERVICE DOOR EMERGENCY LIGHTS OUT-C/A-RAR EMERGENCY LIGHT LAMP AS IN EMB145 AMM 33-50-09. OPS CK GOODSDR SIMA20220821002Lamp · inoperativeROW 12 CEILING EMERGENCY LIGHT INOP-C/A-RAR ROW 12 CEILING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-08-000-801-A AND 33-50-08-400-801-A. OPC GOOD. END.SDR SIMA20220821001Lamp · inoperativeSERVICE DOOR EMERGENCY LIGHT INOP-C/A-RAR SERVICE DOOR EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-09-000-801-A AND33-50-09-400-801-A. NO FIX. FOUND WIRES DISCONNECTED FROM SPLICE AND SPLICE DAMAGED. RAR SPLICE IAW SWPM 20-21-00 . OPC GOOD. END.SDR SIMA20220714001Efis · inoperativeDESCENDING THROUGH 8,000 FT AURAL WARNING CAUTION CAME, IT WAS THE LANDING GEAR TOO LOW TERRAIN, PULL UP. THE RA WAS SHOWING 30 FT. THE FAILURE LASTED FOR ABOUT 5 SECONDS. DID A RA TEST, THE CAT 2 AMBER ANNUNCIATOR DID NOT SHOW EITHER-C/A-MOVED RA ANTENNAS TO SDR SIMA20220625002Radio Altimeter · intermittentDURING DESCENT THOUGH 6000 RADAR ALTIMETER INDICATED 25' AND RECIVED AUDIBLE "TOO LOW TERAIN AND PULL UP" REF AML PG. 4874576 ITEM 1 "TRANSFERRED TO NRWC 619-ABI-05021"MEL 34-8 AUTH# 060293DM-A -C/A-PERFORMED ERS-EM-34DF-088 PTA, 2.5 MILLIOHMS REQUIREMENT FROMSDR SIMA20220218002None · noneRH OVERWNIG EMERGENCY LIGHT INOP-C/A-RAR RH OVERWING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.SDR SIMA20211016001None · noneOVERWING EMERGENCY EXIT FORWARD CEILING LOCATOR LIGHT INOP-C/A-RAR NO. 6 EMERGENCY LIGHT AC/DC INVERTER IAW EMB 145 AMM 33-50-11. OPC GOOD.SDR SIMA20210719002Light · inoperativeDURING PS-2 CHECK FOUND RH CENTER FAIRING EXTERIOR EMERGENCY LIGHT INOP-C/A-RAR RH CENTER FAIRING EXTERIOR EMERGENCY LIGHT IAW EMB 145 AMM 33-50-10. OPS CHECK GOOD.SDR SIMA20210714002Light · brokenEMERGENCY FLOOR LIGHT AT ROW 8/9 WIRE BROKEN OFF-C/A-REPLACED EMERGENCY FLOOR LIGHT STRIP AT ROW 8/9 IAW EMB 145MM 33-50-12.SDR SIMA20210709003Clamp · brokenFA EMERGENCY FLASHLIGHT MOUNT HAS A BROKEN CLAMP-C/A-RAR FWD FA EMERGENCY FLASHLIGHT IAW EMB145 AMM 33-50-16. OPC GOOD.SDR SIMA20210104001Flashlight Assy · brokenFA EMERGENCY FLASHLIGHT CLIP AND FLASHLIGHT BROKEN. MEL 25-53, AUTH 010001-C, LGPG 4714201, ITEM 1. C/A: REMOVED AND REPLACED F/A EMERGENCY FLASHLIGHT ASSEMBLY, IAW EMB 145 CMM 25-60-14. OPERATIONS CHECKED GOOD. MEL NR 25-53 RESTORED.SDR SIMA20201204003Latch · brokenF/A EMERGENCY FLASHLIGHT HOLDER FWD CABIN HAS LATCH BROKE. C/A: R & R FWD EMERGENCY FLASHLIGHT, IAW EMB 145 AMM 33-50-16. OPERATIONS CHECK GOOD.SDR SIMA202009076004Connector · looseAPROX 15,000 MSL - RECEIVED ARUAL TO LOW TERRAIN WARNING BRIEFLY APPROXIMATELY 4,000 MSL. RECEIVED AURAL TOO LOW TERRAIN AND LANDING GEAR WARNING BRIEFLY. TRANSFERRED TO NRWC 619-ABI-03950 J. WILLIAMS 507866. C/A FOUND LT AND RT RA ANTENNA CONNECTIONS VERY SDR SIMA2020083129006Drag Angle · crackedCRACK ON RH FWD VERTICAL TO FUSELAGE DRAG ANGLE NEAR AFT END IN RADIUS.-C/A-REMOVED AND REPLACED RH FWD VERTICAL TO FUSELAGE DRAG ANGLE IAW EMB 145 SRM 51-40-02.SDR SIMA2020083129005Skin · deformedSKIN DEFORMATION LOCATED AT FRAME 23 STRINGERS 16R ? 17R.-C/A-SKIN DEFORMATION LOCATED AT FRAME 23 STRINGERS 16R ? 17R. FOUND STRINGER 17R AT FR 23 TO BE BENT. PERFORMED STRINGER REPAIR IAW EMB 145 SRM 53-00-03-RE.SDR SIMA20200824005Rib · crackedLEFT WING RIB 21 INSIDE PANEL 551CB IS CRACKED. REPAIRED THE LT WING RIB 21 IAW SRM 57-20-07RE ITEM 4.SDR SIMA20200824002Nut Plate · corrodedCARGO DOOR UPPER NUT PLATE HOLES HAVE CORROSION 5 EA. REMOVED AND REPLACED CARGO DOOR UPPER NUT PLATE PROFILE IAW SRM 51-40-02.SDR SIMA20200824001Web · chafedCARGO DOOR LOWER FWD WEBBING CHAFED AT FASTENER. REPAIRED CARGO DOOR LOWER FWD WEBBING IAW SRM 52-30-01RE AND ETN-EM-52-043.SDR SIMA202008242003Nut Plate · corrodedCARGO DOOR LOWER NUT PLATE HOLES HAVE CORROSION 7 EA.-C/A-REMOVED AND REPLACED CARGO DOOR LOWER NUT PLATE PROFILE IAW EMB 145 SRM 51-40-02.SDR SIMA202008210001Yoke · crackedRH ENGINE FWD LOWER YOKE CRACKED. REMOVED AND REPLACED RH ENGINE FWD LOWER YOKE IAW ERS-EM-54MR-698.SDR SIMA202008109002Wire · damagedEMERGENCY LIGHT STRIP 8 HAS WIRE INSULATION PULLED OUT OF HOUSING ON BOTH WIRES. REMOVED AND REPLACED THE EMERGENCY LIGHT IAW AMM 33-50-12.SDR SIMA2020082104002Skin · damagedLEFT ELEVATOR TRAIL EDGE UPPER SKIN HAS HOLE. PERFORMED A REPAIR ON THE LT ELEVATOR TRAIL EDGE IAW ERS-EM-55MR-854.SDR SIMA20200729004Battery Pack · inoperativeNR 4 EMERGENCY BATTERY INOP. C/A COMPLETE: R & R NR 4 EMERGENCY BATTERY AND BATTERY POWER SUPPLY, IAW EMB 145 AMM 33-50-04 ETN-EM-20-040 BONDING TEST GOOD. EMERGENCY LIGHTING SYSTEM, OPS CHECK GOOD MILLIOHM METER NR 6488.SDR SIMA20200729003Light · crackedLT EMERGENCY LIGHT STRIP PANELS AT POSITIONS 2, 3, 5, AND 8 ARE CRACKED/BROKEN. C/A COMPLETE: REMOVED AND REPLACED LT EMERGENCY LIGHT STRIP COVER PANELS AT POSITIONS 2,3,5, AND 8, IAW EMB-145 AMM 33-50-12. SEE BOW 346487 FOR INSTALL ONTO AIRCRAFT.SDR SIMA20200729002Battery Pack · not reportedA3265 OPS A. REMOVE AND REPLACE EMERGENCY LIGHTING BATTERY ASSY/BATTERY CHARGER EMB WC 33-700-19 CRJ WC 33-002 ETN-EM-25-385 PN 2013-1A SN 10484 POS 3. C/A COMPLETE: REMOVED AND REPLACED EMERGENCY LIGHTING BATTERY ASSY/ BATTERY CHARGER PN 2013-1A SN 104848 PSDR SIMA202006291004Outflow Valve · failedCABIN ALT REACHED 9600FT @ AT FL190 AFTER DESCENDING TO 10000FT CABIN SLOWLY REPRESSURIZED TO 400 FT (DELTA)P 4.4 NORMAL FOR THAT ALTITUDE-C/A-FOUND PNEUMATIC OUTFLOW VALVE STICKING, REPLACED AND REMOVED P.O.V. IAW AMM 21-31-04. PERFORMED FUNCTIONAL CHECK IAW SDR SIMA202006198002Support · damagedSUPPLEMENTAL MAIN PAX ENTRY DOOR VERY HARD TO OPEN.-C/A-WHILE T/S HARD TO OPEN AND INSPECTION SUPPORT ASSY BOLTS IAW ETN-EM-52-052 FOUND DAMAGE TO THE BEARING SUPPORT AND LOCKING SHAFT MIGRATING. REF ITEM #3 THIS LOG PAGE FOR DISCREPANCIES. REMOVED AND REPLACESDR SIMA202006176001Lock · lack of lubeFA REPORTS ENTRY DOOR IS EXTREMELY HARD TO UNLOCK + WILL UNLOCK HALFWAY THEN GOT STUCK. ONCE UNLOCKED IT IS HARD TO PUSH OPEN.-C/A-LUBRICATED PAX DOOR ROLLERS IAW AMM 53-21-03. NO DEFECTS NOTED.SDR SIMA202002110001Drive Unit · damagedFLAP FAIL UPON ACCD ALT ON TAKEOFF-C/A-T/S FLAP FAIL MSG IAW FIM 27-51-00-810-801-A REMOVED AND REPLACED FPDU IAW EMB 145 AMM 27-53-04 NO FIX REMOVED AND REPLACED FECU IAW EMB 145 AMM 27-53-02 OPS CHECK GOOD IAW EMB 145 AMM 27-53-00-700-802-A NO FURTHER DEFSDR SIMA2020020411008Charger · failedGALLEY EMERGENCY LIGHTS NOT PASSING FUNCTIONAL CHECK-C/A-REMOVED AND REOLACED NUMBER 2 EMERGENCY BATTERY POWER SUPPLY ASSY IAW EMB AMM 33-50-04. EMERGENCY LIGHTING BATTERY P/N 2013-1ASMI S/N 67906SDR SIMA202002061108Wing · damagedWX-DMG / A/C LANDED SLID OFF RWY INTO TERRAIN. NO INJ TO CREW/PAX. ALL PAX TRANSPORTED TO TERMINAL BY BUS. EMERGENCY DECLARED.-C/A-PENDING CORRECTIVE ACTIONS. REINSTALLED RH WING SPEED BRAKE ACTUATOR IAW STEPS 3A THRU/INCLUDING 3J(6) OF AMM 27-62-02-400-801A.SDR SIMA2019100198011Lamp · inoperativeROW 17 AISLE EMERGENCY LIGHT INOPERATIVE. R & R ROW 17 AISLE EMERGENCY LIGHT LAMP IAW AMM 33-50-08. OPS CHECKED GOOD. NO FURTHER DEFECTS NOTED.SDR SIMA20190711003Warning System · false activationBLD 2 LEAK WARNING MSG. C/A-PERFORMED INSPECTION AND LEAK CHECK OF BLEED 2 AIR SYSTEM AS PER AMM 36-11-09. WITH ENGINE RUNNING FOR 25 MINS. NO LEAKS OR FAULTS NOTED.SDR SIMA20190320006Light · inoperativeMAIN-DOOR EMERGENCY LIGHT INOP. C/A-REMOVED AND REPLACED MAIN-DOOR EMERGENCY LIGHT LAMP IAW AMM 33-50-06-000-801-A AND AMM 33-50-06-400-801-A. OPS CHECK GOOD. NO MORE DEFECTS NOTED AT THIS TIME. END.SDR SIMA20190205003Light · inoperativeFWD CEILING EMERGENCY LIGHT INOP. R&R EMERGENCY LIGHT IAW AMM 33-50-08. OPC GOOD.SDR SIMA20180930005Hinge Fitting · wornRIGHT AILERON OUTBOARD HINGE FITTING HAS A MIGRATING BUSHING. REMOVED AND REPLACED RT AILERON OB HINGE FITTING/BUSHING ASSY IAW EO EM-27MR-112.SDR SIMA20180926001Structure · unknownEM-52MR-236 PTB COCKPIT UNDERFLOOR ACCESS HATCH FRAME REPAIR-C/A-C/W EO# EM-52MR-236 PART BSDR RAIA2018080620001Bracket · looseLDG AIR/GND FAILED, INSPECTED AND FOUND A LOOSE BRACKET HOLDING THE WOW SWITCH ON THE LT AFT LANDING GEAR, PERFORMED AN OPS CHECK OF ALL 5 WOW SWITCHES INDIVIDUALY. PERFORMED AIR GROUND SYSTEM SIMULATION TEST THREE TIMES, OPS CHECKED GOOD, NO MESSAGE ON EISDR RAIA201803310002Warning Message · illuminatedNR 2 PACK OVERLOAD. R & R THE SLEEVE, OPS CHECKED GOOD.SDR RAIA2018042610001Shear Tie · corrodedFRAME 65 SHEAR TIE CORRODED ON THE LOWER END BY CARGO DOOR SILL. REPAIRED THE SHEAR TIE.SDR RAIA201801310002Clamp · looseBLEED 2 LEAK ON CLIMB OUT FOUND HIGH STAGE VLV CLAMP LOOSE AND TIGHTENED. FOUND BLEED VALVE NR 2 CLAMP LOOSE AND TIGHTENED. RAN THE LEAK CHECK AT 90%. NO LEAKS NOTED AT THIS
TIME.SDR RAIA201801300002Sensor · looseNR 2 BLEED LEAK IN FLT, WHILE CLIMBING THROUGH 13,000 FEET. QRH PERFORMED, NO CHANGE. SECURED A LOOSE TEMP SENSOR ON THE DUCT FORWARD OF THE NR 2 PRE COOLER. OPS CHECKED GOOD.SDR RAIA201801280001O-Ring · leakingNR 2 BLEED LEAK WARNING IN FLIGHT. FOUND A BROKEN O-RING AT DUCT JOINT 14. R & R O-RING. OPS CHECKED GOOD.SDR RAIA201801220001Smoke Detector · false activationEICAS WARNING BAGG SMOKE DURING PUSH. BAGGAGE FIRE EXT BUTTON PRESSED. REMOVED AND REPLACED FWD CARGO BAY SMOKE DETECTOR. OPS CHECK GOOD.SDR RAIA201801050002Skin · gougedSKIN REPAIR DOUBLER AT FRAME 75, STRINGER 2R GOUGED. REPAIRED THE SKIN DOUBLER.SDR RAIA201712260003Frame · crackedFRAME 73 CRACKED JUST BELOW THE RT AFT FLOOR SILL. R & R THE FRAME LOWER SECTION.SDR RAIA201712060002Frame · crackedFRAME 66 CRACKED AT STRINGER 16R. REPAIRED THE FRAME.SDR RAIA201712260001Shear Tie · corrodedFRAME 65 SHEAR TIE CORRODED IN THE CARGO DOOR CUTOUT, LOWER CORNER. REPAIRED THE SHEAR TIE.
Back to N619AE