N634NK
Service difficulty reports · 71
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N634NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N634NK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2018092802871Unknown · odorINTERMITTENT SHUTTERING NOISE AND VIBRATION FROM CENTER CONSOLE WHILE AT CRUISE. FOLLOWED BY STRONG BURNT RUBBER SMELL. SMELL WENT AWAY AFTER A FEW MINUTES.-PERFORMED TSM 05-50-00-810-831-A. FOUND TO BE TYPE 9 ODOR. EXAMINED ALL RELATED EQUIPMENT WITH NO FAULTSDR GTIA2018070502733Unknown · odorAT THE GATE FLIGHT ATTENDANTS REPORTED CABIN ODOR / FUME EVENT ON FINAL APPROACH. PERFORMED TROUBLE SHOOTING OF CABIN ODOR / FUME EVENT IAW TSM 05-50-00-810-831-A. COULD NOT DUPLICATE. AC OK FOR CONTINUED SERVICE.SDR GTIA2018061002693Bottle · low pressureDURING A WEEKLY CHECK, FOUND THE L1 DOOR ASSIST BOTTLE BELOW LIMITS. SERVICED THE L1 DOOR ASSIST BOTTLE IAW 52-10-00.SDR GTIA2018061192690Unknown · odorFLIGHT ATTENDANTS AND PASSENGERS COMPLAINED OF A FOUL ODOR THROUGHOUT ENTIRE CABIN. ODOR SIMILAR TO DIRTY CAT LITTER. RAN BOTH ENGINES AND APU TO ISOLATE BLEED SORCES, FOUND NO DIRTY CAT LITTER ODOR COMING FROM EITHER THE ENGINES OR APU IAW AMM 71-00-00 AND SDR GTIA2018052202662Bottle · low pressureL1 DOOR ASSIST BOTTLE REQUIRE SERVICE. SERVICED L1 DOOR ASSIST BOTTLE AMM 52-10-00.SDR GTIA201804192591Unknown · odorCLASS 2 MAINTENANCE MESSAGE ON STATUS PAGE, E/A REPORTED A BURNING ODOR IN THE FORWARD GALLEY. RESET THE SYSTEM IAW AMM 23-73-00. FAULT CLEARED , NO DEFECTS NOTED OR ODOR OF BURNING NOTED.SDR GTIA2018041202576Bottle · low pressureL1 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICE THE L1 PASSANGER DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2018012402362Seal · leakingNR 2 PACK PRODUCED AN ODOR. IAW TSM 05-50-00 FOUND DEOILER SEALS LEAKING. R & R THE DEOILER SEAL IAW AMM 76-60-31. PERFORMED DECONTAMINATION OF ENVIROMENTAL SYSTEM IAW AMM 21-00-00. R & R RECIRCULATION FILTER IAW AMM 21-21-41.SDR GTIA2018012402361Seal · leakingODOR DETECTED, ISOLATED THE NR 1 PACK IAW TSM 05-50-00. FOUND DEOILER SEALS LEAKING. R & R THE DEOILER SEALS IAW AMM 72-60-31. PERFORMED DECONTAMINATION OF ENVIROMENTAL IAW AMM 21-00-00. R & R RECIRCULATION FILTER IAW AMM 21-21-41.SDR GTIA2018012402360Unknown · odorFA REPORTED AN ODOR DURING CLIMBOUT AND DESCENT, IN THE FWD GALLEY. NO ODOR REPORTED FROM COCKPIT. PERFORMED AN OPERATIONAL TEST OF THE APU AND THE NR 1 & 2 A/C PACKS IAW AMM 49-00-00-710-010, AND 12-33-21-618-001. NO ODOR NOTED. PERFORMED A RUN OF THE NR 1SDR GTIA2017100402190Bottle · low pressureL1 DOOR ASSIST BOTTLE LOW. BOTTLE SERVICED IAW AMM 52-10-00.SDR GTIA2017092802184Bottle · low pressureL1 DOOR ASSIST BOTTLE REQUIRE SERVICE. SERVICED L1 DOOR ASSIST BOTTLE AMM 52-10-00.SDR GTIA2016121601710Oxygen Mask · unwanted deployAFTER TAKE OFF, ROW 30 D,E,F OXYGEN MASKS DEPLOYED. REPACKED THE OXYGEN MASKS IAW AMM 35-21-43. PERFORMED MANUAL OXYGEN MASK DROP TEST IAW AMM 35-23-00. TESTED GOOD.SDR GTIA2016121501707Oxygen Mask · unwanted deployROW 1 SEAT D & F OXYGEN MASK DEPLOYED AT GATE. PERFORMED MANUAL OXYGEN MASK DROP TEST IAW AMM 35-23-43 TEST GOOD.SDR GTIA2016121501706Oxygen Mask · unwanted deployROW 9 ABC OXYGEN MASKS DROPPED. PERFORMED MANUAL OXYGEN MASK DROP TEST IAW AMM 35-23-43 TEST GOOD.SDR GTIA2016121501705Oxygen Mask · unwanted deployOXYGEN MASKS ON ROW 5ABC DEPLOYED ON LANDING. PERFORMED MANUAL OXYGEN MASK DROP TEST IAW AMM 35-23-43 TEST GOOD.SDR GTIA2016121501704Oxygen Mask · unwanted deployROW 27ABC OXYGEN MASK DROPPED DURING BOARDING ( PASSENGER OXYGEN STORAGE PASSENGER OXYGEN MODULES ). PERFORM OPS CHECK OF MANUAL MASK RELEASE IAW AMM 35-23-00.OPS CHECK GOOD.THIS CLEARS DMI # 2212370-1.MOC NOTIFIED.PLACARD REMOVEDSDR GTIA2016061901486Oxygen Mask · brokenCAPTAINS OXYGEN MASK INFLATION RED GRIP IS CRACKED. R & R CAPTAIN`S OXYGEN MASK IAW AMM 35-12-41. NO LEAKS NOTED.SDR GTIA2015082801629Unknown · odorSTRONG SMOKE ODOR REPORTED BY AFT F/A THEN FWD. OCCURRED AFTER THRUST REDUCTION ODOR DISIPATED AFTER LEVEL OFF AND DESCENT UNDER WEIGHT LANDING. PERFORMED TROUBLESHOOTING AND FAULT CONFIRMATION IAW TSM'S 05-50-00-810-831-A AND 71-00-00-810-801-A. NO CABIN OSDR GTIA2015072501606Bottle · low pressureL1 DOOR ASSIST BOTTLE HAS LOW PRESSURE. SERVICED L1 DOOR ASSIST BOTTLE IAW AMM 52-10-00-210-004.SDR GTIA2015053101570Bottle · low pressureL1 DOOR ASSIST BOTTLE REQUIRES SERVICING. L1 DOOR ASSIST BOTTLE SERVICED IAW AMM 52-10-00.
Back to N634NK