N641UA
Service difficulty reports · 311
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N641UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N641UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009111803601Actuator · malfunctionedAPU WON'T START. STATUS MSG, APU DOOR. REPLACED INLET DOOR ACTUATOR, OPS CHECKS NORMAL.SDR UALA2009091602938Pump · leakingLEFT CTR ADP LEAKING HYD FLUID. APPEARS TO BE A CAPPED FITTING ON INBOARD BOTTOM OF PUMP. REMOVED CENTER HYD SYS ADP. CONTINUING ADP INSTALLATION. INSTALLED ADP, OP CHECKS GOOD.SDR UALA2009091502911Apu · malfunctionedTOWER REPORTED THICK SMOKE COMING FROM APU. APU SUBSEQUENTLY AUTO SHUT DOWN. REMOVED APU. COMPLETED INSTALLATION OF NEW APU.SDR UALA2009060501610Oil Filter · faultyLEFT ENGINE HAS OIL FILTER BYPASS WARNING MSG HISTORY. REPLACED FILTER. CHECKED MAGNETIC CHIP DETECTORS.SDR UALA2009050501289Processing Unit · faultedSTATUS MSG FUEL QTY CHANNEL. REPLACED FUEL QTY PROCESSOR. ORIGINAL QTY PROCESSOR FAULTED CHANNEL 1 AND 2. AMR PROCESSOR FAULTS CHANNEL 1 ONLY. CHANNEL 2 OK AND QTY VERIFIED.SDR UALA2009041001043Panel · damagedRT WING LOWER WING FIXED TRAILING EDGE PANEL 651VB HAS A 1.5 INCH CRACK RUNNING FORE TO AFT. CRACK IS LOCATED 5.5 INCHES FROM INNER EDGE OF PANEL AND 0.75 INCHES OUTBOARD OF NEAREST FASTENER. REMOVED TRAILING EDGE RT WING PANEL. ROUTED PANEL TO SHOP 273. PSDR UALA2009031000694Skin · damagedFOUND LIGHTNING STRIKE EXIT DAMAGE ON RUDDER TRAILING EDGE. DAMAGE IS LOCATED APPROXIMATELY 8 FEET UP FROM LOWER EDGE. DAMAGE IS A SEMI CIRCULAR DELAMINATED ARE MEASURING 2 INCH BY 1.25 INCH, CONTAINED IN CENTER IS A .75 BY 1.25 INCH AREA OF EXPOSED AND DAMASDR UALA2009030300694Skin · damagedFOUND LIGHTNING STRIKE EXIT DAMAGE ON RUDDER TRAILING EDGE. DAMAGE IS LOCATED APPROXIMATELY 8 FEET UP FROM LOWER EDGE. DAMAGE IS A SEMI CIRCULAR DELAMINATED ARE MEASURING 2 INCH BY 1.25 INCH, CONTAINED IN CENTER IS A .75 BY 1.25 INCH AREA OF EXPOSED AND DAMASDR UALA2009012100227Smoke Detector · no testAC-3 LAV SMOKE DETECTOR DOES NOT TEST. REPLACED AC-3 LAV SMOKE DETECTOR. OPS CHECKS NORMAL.SDR UALA2009012100226Latch · gougedRT OVERWING SLIDE COMPARTMENT DOOR NR 2 LATCH GOUGED. REPLACED RT OVERWING SLIDE COMPARTMENT DOOR NR 2 LATCH.SDR UALA2009012100225Latch · damagedLEFT WING OVERWING SLIDE DOOR, NR 3 LATCH HAS GROOVE IN SLIDER. REPLACED LT OVERWING SLIDE DOOR NR 3 LATCH. OPS CHECKS GOOD.SDR UALA2009010500046Actuator · faultyDURING START OF RT ENG, 'R FUEL SPAR VAL' EICAS MSG AND SPAR VLV LIGHT ILLUMINATED. ENG SUBSEQUENTLY SPOOLED DOWN. REPLACED ENG FUEL SHUTOFF ACTUATOR AND ACP ENG OPS CHECK.SDR UALA2008122607009Wire · burnedFWD CARGO COMPARTMENT P35 POPPING CB`S AS FOLLOW: C171, C173, C167, C168 & C169. FOUND 24 WIRES BURNED OUT UNDER PNL PDU 7L. ALL WIRES ISOLATED AND AFFECTED PDU'S ELECT PLUGS REMOVED AND ISOLATED. FWD CARGO HDG SYS INOP. STARTED TO IDENTIFY WIRES WITH LABESDR UALA2008120106697Circuit Breaker · trippedBURNING ELECTRICAL SMELL IN FWD CABIN NEAR VIDEO CONTROL EQUIPMENT WITH BUFFER BOX CB`S J15 AND J16 REPORTED TRIPPED BY FLT CREW. RESET J15 & J16 CB'S ON BUFFER BOX OPS CK OK.SDR UALA2008111306132Circuit Card · faultyAFTER TAKEOFF AIR-GND DISAGREE STATUS MSG. RTFL. REPLACED ENTIRE PROXIMITY SWITCH ELEC UNIT WITH ALL CARDS AND NLG SWG OPS OK. REF SCHEMATIC:32-09-03 AND 32-09-02. REPLACED RELAYS K203, K293, K219 AND K209. AIR-GND RELAY TEST FAILS STEP I(3) AND I(7) FOR SDR 2008UALA06132Warning System · activatedAFTER T/O, AIR-GND DISAGREE STATUS MSG. RTFL.SDR 2008UALA04385Light · unsecureFWD GALLEY X-AISLE EEL LIGHT INOP. SECURED EEL STRIP TO PWR SUPPLY, OPS CHECKS GOOD.SDR 2008UALA04384Light · unsecureEEL LIGHTS LEFT SIDE FC ROWS 1AB & 2AB INOP. SECURED EMERGENCY LIGHTS TO POWER SUPPLY RIBBON. OPS CHECKS GOOD.SDR 2008UALA04383Light · inoperativeEEL LIGHT ADJACENT TO LAV AT DOOR 1L INOP. SPLICED EEL LIGHT STRIP TO CKT PWR. OPS CHECKS GOOD.SDR 2008UALA04382Connector · looseEMERGENCY LIGHT ADJACENT DOOR 1R INOP. SECURED LOOSE CONNECTOR. OPS CHECK OK.SDR 2008UALA03281Light · inoperativeRIGHT FWD CABIN EEL INOPERATIVE.SDR 2008UALA03149Aspirator · leakingLEAKING ASPIRATOR. THERE IS NO PHYSICAL DAMAGE TO THE ASPIRATOR. REPLACED ASPIRATOR.SDR 2008UALA02962Warning System · activatedDURING GEAR RETRACTION, HAD A C-HYD SYS PRESSURE AND AIR DEMAND PUMP EICAS ALONG WITH A C-HYD SYS.SDR 2008UALA02050Blade · crackedCRACK FOUND IN THE 5TH STAGE COMPRESSOR BLADE ROOT OF THE NR 1 ENGINE. REPLACED ENGINE.SDR 2008UALA01759Warning System · activatedAPU GEN OFF EICAS MSG WITH ASSOC SWITCH LIGHT ILLUMINATED.SDR 2008UALA01024Light · faultyEMERGENCY EXIT LIGHT AT FLIGHT DECK DOOR IS ON WITH STANDBY SWITCH IN OFF POSITION.SDR 2008UALA00097Blade · bentONE BLADE ON LEFT ENGINE BENT OVER 90 DEGREES. REPLACED BLADE NR 37 DUE TO BENT AND OPPOSITE BLADE NR 18 PER MM 72-31-02. THREE OTHER BLADES NR 35, 36, 38 ARE CF'D. ACCOMPLISHED RII INSPECTION OF NR 35 36 AND 38 BLADES PER MM 72-31-02, OK FOR FINAL .020\ INSDR 2007UALA05197Light · inoperativeFLOOR EEL STRIP AT SEATS 13 AND 14 AB INOP.SDR 2007UALA04337Blade · failedECM HAS DETECTED PARAMETERS SHIFT AT BOTH TAKEOFF AND CRUISE. ENGINE REPLACED. SHOP TEARDOWN REVEALED HEAVY HPC BLADE DAMAGE. THE DAMAGE WAS A RESULT OF FAILURE IN A 5TH STAGE DISK KNIFE EDGE. A 5-INCH SECTION OF THE FRONT KNIFE EDGE FRACTURED, CAUSING A 2-SDR 2007UALA04072Unknown · unknownCREW COMMENTS: FUEL OVERBURN BY 6000 PLUS POUNDS.
SDR 2007UALA03731Battery · inoperativeLEFT SIDE EEL IS INOP FROM SEAT 27 TO AFT GALLEY. REPLACED BATTERY & EEL CHECKS GOOD.SDR 2007UALA03537Warning System · activatedRTFL DUE TO L/E SLAT DISAGREE MESSAGE. EVENT RECURRED ON NEXT FLIGHT OUT.SDR 2007UALA03614Light · inoperativeLEFT SIDE EXTERIOR EMERGENCY LIGHTS (L388): (L389): (L313 ): (L395): AND (L642) INOP.SDR 2007UALA03485Handle · obstructedRIGHT AFT EMERGENCY ESCAPE HATCH AUTO ARM AND AUTO FIVE SWITCHES DID NOT MOVE TO THE (UP) POSITION, DURING TEST.SDR 2007UALA03484Mechanism · out of positionLEFT OVERWING SLIDE INFLATION CYLINDER PULL FORCE MECHANISM BALL IS IN THE WRONG POSITION, BALL IS IN FRONT OF THE RETAINER SPRING, NOT BEHIND IT AS REQUIRED.SDR 2007UALA03483Latch · out of toleranceLEFT OVERWING SLIDE DOOR LATCHES NR 1, 2, 3 & 4 FAIL EDGE MARGIN TEST.SDR 2007UALA02551Battery · faultyEMERGENCY FLASH LIGHT BETWEEN 1L & 1R FLIGHT ATTENDANT SEAT DOES NOT BLINK. [08-08-07] REPLACED BATTERY AND SEAL. AIRCRAFT OK FOR SERVICE.SDR 2007UALA00841Aspirator · leakingBOTH ASPIRATORS LEAKING BETWEEN JET PLATE ASSEMBLY AND SENSING TUBE. REPLACED BOTH ASPIRATORS. SUSPECT SIDE LOAD ON ASPIRATORS DURING PACKING CAUSED LEAKS.SDR 2007UALA00227Battery · inoperativeEMERGENCY OVERWING EXIT SIGNS INOP ALL POSITIONS. REPLACED BATTERY AND BASE; OPS CHECKED OK .SDR 2006UALA02008Warning Light · illuminatedTAT PROBE LIGHT ILLUMINATED JUST AFTER TAKEOFF. [5-1-07] REPLACED THE TOTAL AIR TEMPERATURE SENSOR. OP CHECKS OK. CAUSE SUSPECTED TO BE INTERNAL ELECTRICAL SHORT IN SENSOR CIRCUIT.SDR 2006UALA01599Fan · failedELECTRICAL BURNING ODOR IN FLIGHT DECK. FOUND FAILED FORWARD EQUIPMENT COOLING EXHAUST FAN. REPLACED EQUIPMENT COOLING EXHAUST FAN. FOUND FAN IMPELLER ROUGH TO ROTATE. ALSO, A SMALL RADIAL PLAY OF THE IMPELLER WAS ALSO NOTICED WHILE HOLDING THE FAIRING.SDR 2006UALA00468Attach Fitting · misdrilledRIGHT WING INBOARD AILERON, INBOARD SECTION LEADING EDGE ATTACH FITTING MISDRILLED. S/D* THE SUBJECT FITTING WAS MISDRILLED DURING INSTALLATION. REPAIRED PER TIMCO REO-G11452.SDR 2006UALA00471Fitting · crackedNR 2 PYLON MIDSPAR FITTING LOWER TANG AT INBOARD CLOSEOUT ANGLE HAS 2 EACH CRACKS COMING OUT OF THE INBOARD BOLT HOLE. 2 CRACKS EMANATING FROM INBD BOLT HOLE OF CLOSEOUT ANGLE INSTALLED OVER NR 2 PYLON MIDSPAR FITTING LOWER TANG WAS FOUND. THE CLOSEOUT ANGLE SDR 2006UALA00470Stiffener · gougedLT WING STIFFENER GOUGED BEYOND LIMITS AT WS 825 REAR SPAR. THE LEFT WING STIFFENER, P/N 112T1237-1, WAS FOUND GOUGED BEYOND LIMITS AT WS 825 REAR SPAR. NO DAMAGE WAS REPORTED ON THE ADJACENT STRUCTURES. THEREFORE, THE GOUGED WAS LIKELY CAUSED BY FOD. REPLSDR 2006UALA00469Angle · crackedCLOSEOUT ANGLE BELOW MID SPAR FITTINGS OF NR 2 PYLON HAS CRACKS FROM INBOARD AND OUTBOARD ENDS. INBD AND OUTBD ENDS ON CLOSEOUT ANGLE BELOW MID SPAR FITTINGS OF NR 2 PYLON WERE FOUND CRACKED. THE CLOSEOUT ANGLE WAS REPLACED USING 767-300 SRM 51-40-02.SDR 2006UALA00452Failsafe · corrodedCORROSION ON STA 1562 FAIL-SAFE, P/N 146T1223-30, BETWEEN STR 39L & 39R. REPAIRED BL 0 AREA CORROSION AT STA 1562 FAILSAFE CHORD WITH A REPAIR ANGLE AND FILLER PER TIMCO REO(EVA) G11428 AND UA EVA 60127. REPAIR IS FAA APPROVED AND PERMANENT.SDR 2006UALA00448Bulkhead · crackedBS 1809 BULKHEAD RT SIDE, FWD OUTER CHORD, INBD FLANGE HAS A CRACK COMING OUT OF THE FASTENER HOLE. DAMAGE FOUND AS A RESULT OF ROUTINE INSPECTION, MANDATED PER AD 2005-11-02. REPAIRED PER AD REQUIREMENTS.SDR 2006UALA00398Hinge Fitting · crackedLEFT INBD FLAP-CENTER HINGE FITTING CRACKED ON INBD AND OTBD FLANGES. THE SUBJECT HINGE FITTING WAS FOUND CRACKED ON THE INBOARD AND OUTBOARD FLANGE. REPAIRED PER 767-300 STRUCTURAL REPAIR MANUAL 57-53-02.SDR 2006UALA00397Seat Track · brokenMAIN SEAT TRACK OUTBD LT SIDE STA 786-808, LBL 88 INBD NODES BROKEN OFF FROM TRACK. DAMAGED SEAT TRACK REMOVED/REPLACED PER SRM.SDR 2006UALA00354Floorbeam · corrodedAFT PIT FLOORBEAM AT STA 1197+132 BETWEEN STR 33R TO 33L IS CORRODED AT 6 LOCATIONS. CORRODED FLOORBEAM REPAIRED PER SRM. DAMAGE FOUND BY ROUTINE INSPECTION.
Back to N641UA