N642UA
Service difficulty reports · 354
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N642UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N642UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010081803021Oxygen Mask · unwanted deploySEAT 37AB O2 MASK DEPLOYED AFTER TAKEOFF. FLT ATTENDENT RESTOWED THEM. MAINTENANCE TO INSPECT SEAT 37A+B O2 MASKS AND CONFIRM GENERATOR NOT FIRED AND FOR PROPER RESTOWING OF MASK AND HOSE ASSEMBLY. INSPECTED O2 GENERATOR, GOOD. RESTOWED O2 MASKS AND LATCHED CLSDR UALA2010062502260Battery Pack · faultyEMERGENCY EXIT LIGHT ON AT DOOR 2L. REPLACED EMERGENCY BATTERY PACK FOR DOOR 2L.SDR UALA2010062102186Apu · failedFIRST APU START ATTEMPT APU AUTO SHUTDOWN AT NEAR FULL RPM. LARGE CLOUD ON START THAT SMELLS LIKE OIL. APU LIT-UP AND THEN AUTO SHUTDOWN AFTER 1 TO 2 MINUTES. OPENED APU COMPT AND DID NOT FIND ANY LEAKING COMPONENTS AT THIS TIME. BIT APU ECU FOUND "LOW OIL PSDR UALA2010061002031Adapter · brokenWHILE REPLACING RT ENG SPAR VALVE ACT, THE BOLT FLANGE ON THE MOUNTING ADAPTOR PLATE BROKE OFF. REPLACED THE ADAPTOR PLATE.SDR UALA2010060902006Battery Pack · faultyEMERGENCY LIGHTS FLASHING ON & OFF. REPLACED BATTERY PACK POWER SUPPLIES M1556 AND M1561 AND TESTED PER MM. GROUND CHECKS NORMAL.SDR UALA2010051701660Connector · looseEMERGENCY FLOOR LIGHTS FLICKERED ON OFF SEVERAL TIMES THROUGHOUT FLT IN BUSINESS CLASS. RESECURED LOOSE FLOOR LIGHT CONNECTOR ON RT SIDE OF BUSINESS CLASS CARRIED OUT TEST, ALL SATISFACTORILY.SDR UALA2010051401637Fseu · faultyREPEAT ALT FLAP CHECK FAIL. REPLACED 3 PINS ON ALT FLAP EXTEND MOTOR M547 CONNECTOR, REPLACED FSEU & ALT FLAP EXTEND RELAY, OPS TESTED GOOD.SDR UALA2010051301630Probe · failedLEFT EEC MODE EICAS AFTER TAKEOFF-RESET OK. T/S IAW MM, REPLACED NR 1 ENGINE PT2 PROBE IAW MM. ACP PT2 PROBE OPS AND LEAK CHECK IAW TEST NR 7 & NR 14 IAW MM. TEST GOOD.SDR UALA2010051301629Switch · faultySTAB TRIM EICAS IMMEDIATELY AFTER TAKEOFF. FOUND HYD PRESSURE SWITCH 528 BAD. REPLACED 528 PRESSURE SWITCH IAW 767MM, OPS CHK GOOD IAW 767MM. OPS CHK GOOD IAW 767MM. REPEAT GRIPE-STAB TRIM EICAS MESSAGE DISPLAYED & STAB TRIM LIGHT ILLUMINATED. TROUBLESHOT MSDR UALA2010051201612Switch · faultyRAT UNLOCKED DURING APU BUS PRIORITY CHECK. REPLACED AIRSPEED SWITCH S614 IAW 767 MM AND WDW, PERFORMED RAT DROP IAW 767 MM. OPS TEST GOOD. TROUBLESHOOTING HISTORY, FIRST REPLACED K235 RELAY PER FIM AND WDM, NO HELP. REMOVED CONNECTOR D10434P AND FOUND PINSDR UALA2010051101595Web · crackedNR 1 PYLON INTERNAL MID TORQUE BOX UPPER WEB IS CRACKED AT LEFT DRAIN HOLE. MAJOR REPAIR ACCOMPLISHED. STOP DRILLED 2 EACH CRACKS AND FABRICATED A REPAIR DOUBLER AND FILLERS AND INSTALLED PER SRM.SDR UALA2010051101594Motor · faultyALT FLAP SYS FAILED INBOARD CHECK. IND STOPPED HALFWAY BETWEEN 0 AND 1, LEADING EDGE AND TRAILING EDGE DISAGREE. REMOVED AND REPLACED INBOARD SLAT ELECTRIC MOTOR AND TRAILING EDGE FLAP ALTERNATE ELECTRIC MOTOR PER MM. ALT SLAT OPS CHECK GOOD PER MM AND TRAISDR UALA2010050601524Feeder Cable · chafedNR 1 ENGINE PYLON GENERATOR FEED CABLES CHAFING ELECTRICAL WIRE BUNDLE LT SIDE MID PYLON AREA. REROUTED GENERATOR CABLES AND WRAPPED WITH HIGH TEMP TEFLON TAPE LACING CORD. NO DAMAGE TO CABLES NOTED. ALL ACCOMPLISHED IAW BSWPM 20-10-13 ON NON ROUTINE 20299 BSDR UALA2010050601523Feeder Cable · chafedNR 2 ENGINE GENERATOR FEEDER CABLE CHAFING EACH OTHER AT TERMINAL STRIP AT 6:30 POSTITION. REROUTED GENERATOR CABLES AND SECURED WITH HIGH TEMP LACING CORD AND NO DAMAGE TO THE CABLE NOTED. ALL WORK ACP'D IAW GN-MM ON NON ROUTINE 20378.SDR UALA2010030500767Relay · malfunctionedCENTER AIR DEMAND HYD PUMP INOP IN AUTO & ON POSITIONS. FOUND LOW APU BLEED AIR SUPPLY - DF APU BLEED AS PER MEL 3611G. ENGINE NR 1 IDLE RUN ACP AT IAD AND FOUND ADP OP CHECKS NORMAL WITH ENGINE AIR. FOUND LOW APU BLEED AIR SUPPLY - DF APU BLEED AS PER MEL 3SDR UALA2010030500762Pump · inoperativeCENTER AIR DEMAND HYD PUMP INOP IN AUTO & ON POSITIONS.SDR UALA2010012800360Wire Harness · burnedFWD CARGO LOADING SYS INOP. WHILE ID PARTS, RESET SYS CB & SEVERAL BREAKERS POPPED. OPENED FLOOR PANEL TO INSP FOUND BURNED INSULATION & WIRE BUNDLE. STARTED REPAIR TO WIRE BUNDLE. WIRES REPLACED, TEMPORARILY MARKED NR S50 TO NR 59 & PULLED TIED TOGETHER ASDR UALA2010011500196Line · leakingNR 2 ENG FUEL OIL COOLER LINE LEAKING. FOUND A COMBINATION FLEX HARD LINE LEAKING FROM FUEL OIL COOLER, PART AOG'D J3857, LINE IN HAND. LEAK APPEARED TO BE ON THE FLEX PART OF THE LINE APPROX 6 INCHES FROM THE FUEL PUMP CONNECTION. R & R FUEL PUMP INLET TUBSDR UALA2010010400012Pump · crackedFOUND MOUNTING FLANGE OF JETTISON PUMP CRACKED. REPLACED RT OTBD JETTISON PUMP. OPS CHECKS NORMAL.SDR UALA2009122804018Controller · faultyAPU AUTO SHUTDOWN. FOUND APU CONTROL UNIT NOT TESTING. REPLACED APU CONTROL UNIT. REPLACED APU STARTER AND APU CRANK RELAY. LATER APU AUTO SHUTDOWN. APU FAULTS DC PWR LOSS.THE NEWLY FITTED CONTROLLER HAD THIS FAULT ON TWO OTHER AIRCRAFT. REPLACED CONTROLLER. SDR UALA2009122804004Oven · contaminatedON DESCENT BURNING ODOR NEAR BIZ GALLEY. UTILITY BUSES TURNED OFF. ALL PAX CALL LTS ON. WARMING OVEN R11 HAS MOLTEN PLASTIC STUCK TO BOTTOM CAUSING ODOR WHEN HEATED. CLEANED OVEN. INSPECTED E&E, ALL CB'S IN ACFT, NONE POPPED-GALLEY EQPT, CHILLERS, COFFEEMASDR UALA2009112003622Skin · damagedSTATIC DISCHARGE ON CLIMBOUT. SILENT SURGE DETECTED. FOUND 3 LIGHTNING STRIKES JUST AFT OF STA 180.5 JUST ABOVE 27L. DRILLED DAMAGE AND INSTALLED SOLID FASTENER.SDR UALA2009100503110Fan Blade · damagedRT ENGINE FAN BLADE NR 2 HAS LEADING EDGE IMPACT DAMAGE CAUSING DEFLECTION OF LEADING EDGE. REPLACED NR 2 BLADE AND NR 21 BLADE AND ACP ENG GROUND RUN. NO ABNORMAL VIBRATION; ALL INDICATIONS GOOD.SDR UALA2009090302773Transceiver · faultyHF TRANSMISSION AND RECEPTION ARE INOP, WEAK, GARBLED INTERMITTENT, ETC. AT ALL CREW STATIONS. (1 = L HF, 2 = R HF). LEFT HF WILL NOT TUNE. REPLACED LT HF COMM TRANSCEIVER FOR TROUBLESHOOTING. REMOVED AND REPLACED LT HF COMM TRANSCEIVER. DID NOT FIX PROBLESDR UALA2009080602371Slide · damagedLEFT WING SLIDE EICAS AND EMERGENCY DOORS LIGHT FLASHED ON AND OFF INTERMITTENTLY AFTER PUSHBACK. FOUND SLIDE DAMAGED, CAUSING FOREIGN DEBRIS AND LOOSE SLIDE COMPONENTS. REPLACED LEFT OVERWING SLIDE.SDR UALA2009072002131Module · inoperativeSTAB TRIM LIGHT ILLUM ON OVERHEAD PANEL AND EICAS. RESET BOTH SAMS. PERFORMED STAB TRIM TEST PER MEL PROCEDURES AND LEFT PRIMARY TRIM CHANNEL FAILED. NO FAULT BALLS ON THE SAMS. STAB TRIM WORKS WITH FLAPS 5. PROBLEM APPEARS TO BE IN LEFT TRIM LIMIT CIRCUISDR UALA2009070101891Module · faultyEICAS MSG STAB TRIM DISPLAYED & STAB TRIM LIGHT ILLUMINATED. STABILIZER TRIM RATE NORMAL. FOUND LT STAB TRIM AIL LOCKOUT MOD FAULT. REPLACED LT SAM. COMPLETED MCDP GRND TEST 65 STAB TRIM AND AIL LOCKOUT TEST, ALL TEST PASS. NO FAULT INDICATIONS.SDR UALA2009052601515Monitor · faultyNR 1 ENG EICAS VIB READS HIGH. HIGHEST READING 47 (X.X, RANGE 0.0 TO 5.0, ABNORMAL ON 767-322 IF ABOVE 4.0). EXCESSIVE VIBRATION NOT FELT IN AIRFRAME. CREW COMMENTS: L ENG VIB 4.7 IN CLIMB FOR SEVERAL SECONDS. NO VIB FELT. REPLACED AVM CONDITIONER AND OPSDR UALA2009040901027Connector · defectiveEMERGENCY LIGHTS FROM ROW 27JK-34JK INOP. FOUND CONNECTOR CHECK BAD FOR SEAT 32JK. PIN PUSHED BACK AND WILL NOT LOCK. DISCONNECTED CONNECTOR CK AT SEAT 32JK. ONE LIGHT AT SEAT 32JK WILL BE INOP. ALL OTHER SYSTEM OPS OK.SDR UALA2009040901026Battery · dischargedLT EXTERIOR EMERGENCY LIGHT, (2ND FROM TRAILING EDGE OF WING) IS INOP. REPLACED BATTERY ASSY, OPS CHECKED OKAY.SDR UALA2009040901023Light · inoperativeLT EXTERIOR EMERGENCY LIGHT AFT OF TRAILING EDGE WING INOP. RELAMPED EMERGENCY LIGHT, CHECKED OKAY.SDR UALA2009040901022Light · inoperativeEXTERIOR EMERGENCY LIGHT AT DOOR 2L INOP. REPLACED LAMP, CHECKED OKAY.SDR UALA2009022500644Stowage Box · defectiveCAPT O2 MASK MIC INOP. REPLACED STOWAGE BOX.SDR UALA2009021300474Power Supply · faultyEMERGENCY FLOOR LIGHTS AT RIGHT OVERWING EXIT FLICKER ON AND OFF. ARMED EMERGENCY LIGHTS AND RT EEL EXIT LIGHTS CAME ON. REPLACED EEL EMERGENCY POWER SUPPLY M1554, OPS OK.SDR UALA2009012700296Connector · looseEEL LIGHTING BY LAV 124 COMES ON AND OFF UNCOMMANDED. FOUND SUSPECTED LOOSE CONNECTOR FWD OF LAV 124 AISLE. RESECURED CONNECTOR. CYCLED EMERGENCY LIGHTS AND UNABLE TO REPRODUCE FAULT. CONSIDERED OK FOR FURTHER SERVICE.SDR UALA2009012000224Actuator · failedAILERON LOCKOUT LIGHT IS ON. REPLACED RT OUTBOARD AILERON LOCKOUT ACTUATOR.SDR UALA2008122206953Battery · faultyBATTERY DISCHARGE LIGHT ILLUMINATED. REPLACED SHIP'S BATTERY.SDR 2008UALA06477Battery · dischargedAFT EMERGENCY LIGHTS AT R-4 AND L-4, EXIT SIGNS INOP. REMOVED AND REPLACED BATTERY AND BATTERY CHARGER. OPS CHECK GOOD.SDR 2008UALA06476Angle · damagedNR 1 PYLON MIDSPAR FITTING CLOSE-OUT ANGLE, 2 EACH INBOARD FASTENER HOLES ARE ELONGATED IN PREVIOUS REPAIR AREA. MAJOR REPAIR ACCOMPLISHED. REMOVED EXISTING REPAIR ANGLES AND FABRICATED A NEW REPAIR DOUBLER AND TRIPLER ANGLE. BOTH HOLES MEASURE .531 INCH ANSDR 2008UALA06460Socket · dirtyEXTERIOR EMERGENCY LIGHT AT L-2 DOOR IS INOP. CLEANED LIGHT SOCKET AND OPS CHECKED GOOD.SDR 2008UALA06459Housing · brokenLT OVER WING SLIDE CABLE DISCONNECT HOUSING BROKEN. REMOVED AND REPLACED DISCONNECT HOUSING.SDR 2008UALA06379Skin · damagedDOOR 1R OUTER SKIN LOWER EDGE DAMAGE. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR AT LOWER EDGE.SDR UALA2008111306226Slide · no testDURING LT OVERWING SLIDE DEPLOYMENT TEST, AFT HATCH STEP FAILED TO DROP DOWN, CABLE KINKED, STEP WILL NOT DROP FREELY. REPLACED AFT SUPPORT CABLE. OPS CHECKS GOOD. SLIDE FAULTY. AFTER CHECKING THE SLIDE SYS OUT, VERIFIED THE BOTTLE PRESSURE AND WHITE DISKSDR 2008UALA06226Slide · faultyLT OVERWING SLIDE IS FAULTY.SDR 2008UALA05967Switch · faultyL FWD FUEL PUMP INDICATES PUMP ON WITH SWITCH OFF AND APU OFF. LIGHT TESTS OK. RESET CONNECTOR ON PRESSURE SWITCH, NO HELP. REPLACED LEFT FWD BOOST PUMP PRESSURE SWITCH. OPS CHECK OK.
SDR 2008UALA04307Connector · damagedMED CABIN EEL LIGHT AT FRONT OF LAVS LEFT AND RIGHT INOP. FOUND DAMAGED CONNECTORS. REPAIRED LT & RT EMERGENCY LIGHT CABLE CONNECTORS. OP CHECKED OKAY.SDR 2008UALA04306Feeder Cable · inoperativeFIRST CLASS FWD EEL LIGHT INOP. REPAIRED EMERGENCY LIGHT CABLE. OP CHECKED OKAY.SDR 2008UALA04305Light · inoperativeDOOR 1L LOWER EXIT LIGHT INOP.SDR 2008UALA03926Fuse · inoperativeAIRCRAFT BATTERY IS INOP. AIRCRAFT WILL NOT POWER UP. INSTALLED NEW BATTERY. STILL DID NOT POWER UP. REPLACED INTERLOCK FUSES IN P34 PANEL. CHECKS GOOD.
SDR 2008UALA03846Bleed Valve · faultedAPU AUTO SHUTDOWN DURING TAXI OUT. APU AUTO SHUTDOWN DURING TAXI OUT. CONFIRMED APU SURGE BLEED CONTROL VALVE MALFUNCTIONING. REPLACED BLEED VALVE. OPS CHECK OKAY.
Back to N642UA