N642UA
Service difficulty reports · 354
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N642UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N642UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA03758Light · inoperativeEXT EMERGENCY LIGHT JUST AFT OF LT WING INOP. *S/D* FOUND FAULTY LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03757Light · inoperativeFWD GALLEY XAISLE EEL LIGHT INOP. *S/D* FOUND FAULTY LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY, OP CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA03756Light · inoperativeEEL LIGHT IN FRONT OF RT MID LAV INOP. *S/D* FOUND FAULTY LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03755Lamp · inoperativeEXT EMERGENCY LIGHT AT DOOR 2L INOP. *S/D* FOUND BURNED OUT LAMP. REPLACED LAMP, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03632Valve · stuckFWD LAV TANK INDICATING FULL. HALF OF LAVS NOW NOT WORKING. ECONOMY LAVATORY BY DOOR 2L TOILET WILL NOT STOP FLUSHING, FOUND STUCK VALVE. USED A WET PILLOW PER SAM. FLUSHED BOTH TANKS THRU SEVERAL TIMES WITH HONEY-BEE AND PRESERVICE. RESET TOILET TANK LOGICSDR 2008UALA03341Idg · faultyAT TOC HAD LEFT ELEC BUSS POWER PROBLEM OF A TRANSITORY NATURE WHICH MOMENTARILY BLANKED CAPT'S EADI AND EHSI. *S/D* SUSPECT FAULTY BEARING IN IDG. REPLACED NR 1 IDG ASSEMBLY, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03096Engine · malfunctionedLEFT ENGINE STARTED UP WITHIN 95 SECONDS BUT STOPPED ACCELERATING AT 50 PERCENT FOR 10 SECONDS.
SDR 2008UALA03005Turbine Wheel · damagedNR 1 ENGINE SLOW TO IDLE. REPLACEMENT OF STARTER, IDG, FMU, AND 2.95 BV SOLENOID WERE NO HELP. ENGINE REPLACED. SHOP TEARDOWN REVEALED HEAVY HOT SECTION DISTRESS, ESPECIALLY IN THE HP TURBINE STAGE-1 AND STAGE-2 NOZZLE GUIDE VANES. THE STAGE-1 VANES WERE ON SDR 2008UALA02673Line · leakingLEFT HYDRAULIC QTY BELOW RF (.72). FOUND PRESSURE LINE AT RH WING OUTBOARD SPOILER LEAKING REPLACED LINE WITH FLEX LINE PER GNMM 1-0-13-003 OPS AND LEAK CK OK. AC OK FOR SERVICE.
SDR 2008UALA01487Sign · faultyEMERGENCY EXIT LIGHT IN COCKPIT IS ON WHEN SWITCH IS IN ARMED POSITION WHILE ON GROUND. REPLACED PORTABLE EMERGENCY EXIT SIGN ABOVE FLIGHT DECK DOOR PER MM 33-51-01. OPS CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA00901Light · inoperativeEEL LIGHT AT SEAT 35FG INOPERATIVE. REPLACED LAMP, OP CHECKS OK FOR SERVICE.SDR 2008UALA00900Light · inoperativeEXTERIOR EMERGENCY LIGHT JUST AFT OF LEFT WING INOP. REPLACED LAMP, OP CHECKS OK FOR SERVICE.SDR 2008UALA00564Skin · damagedFUSELAGE SKIN APPROX STA 280 BETWEEN STR 2L & 3L HAS BLEND MARKS. MAJOR REPAIR ACCOMPLISHED: MFG'D AND INSTALLED REPAIR DOUBLER WITH BLIND FASTENERS.SDR 2008UALA0041Aspirator · leakingDAMAGED ASPIRATOR, LEAKING.SDR 2008UALA0020Smoke Detector · inoperativeLAVATORY 101 SMOKE DETECTOR INOP.
SDR 2007UALA04980Generator · malfunctionedFLIGHT DIVERTED DUE TO LOSS OF THE RIGHT GENERATOR. EMERGENCY LANDING WAS DECLARED.
SDR 2007UALA04269Pump · failedFLIGHT DIVERTED DUE TO LOSS OF RIGHT MAIN FUEL PUMPS. PUMP CONNECTORS WHERE CROSSED. ALSO FOUND FOUND RIGHT AFT BOOST PUMP CKT BK R OUT C371 .REPLACED BREAKER,FOUND WIRE ARCHING ACCOUNT OF SCREW CROSS THREADED. PERFORMED OPS CHECK.SDR 2007UALA03235Valve · stickingA-C EXPERIENCING EQUIP COOLING FAULTS. V12 OVERBOARD EXHAUST VALVE FOUND TO BE STICKING IN THE PARTIALLY CLOSED POSITION. REPLACED V12 EXHAUST VALVE. DIDN'T SOLVE PROBLEM. :REMOVED & REPLACED EQUIPMENT COOLING OVERHEAT SWITCH. FOUND SUFFICIENT AIR SOURCE INSDR 2007UALA02531Fire Detector · faultyFWD CARGO DETECTOR NR 2 AND GROUND PROXIMITY SYS STATUS WILL NOT CLEAR. [08-08-07] RESTARTED SYSTEM. FWD CARGO "DET 2" MSG CLEARED. GROUND PROX SYSTEM MESSAGE STILL PRESENT. RESET GLIDESLOPE DISCRETE PER MM34-46-00 MESSAGE CLEARED. MESSAGE REPEATED 8 DSDR 2007UALA02265Sensor · out of adjustEMERGENCY DOORS LIGHT ILLUM WITH EICAS MSG POS 11 (05=L EMER DR , 06=R EMER DR, 11=L WING SLIDE, 12=R WING SLIDE). *S/D* FOUND SENSOR FOR DOOR CLOSED, S218 OUT OF ADJUSTMENT. SHIMMED AND ADJUSTED SENSOR PER MM 52-71-00. REACTIVATED DOOR PER MM 25-65-00. OSDR 2007UALA01873Fuel · leakingNOTICED DURING WALKAROUND INSPECTION RUNNING FUEL LEAK OUT OF UPPER PYLON AREA ON RIGHT ENGINE. [07-31-07] FOUND O-RING ON COUPLING "AS" REF IPC 28-22-07 PAGE17 SPLIT IN TWO PIECES. PACKING WAS WRO INSTALLED REF IPC.FOUND O-RING BETWEEN COUPLING NUT AND ONSDR 2006UALA01420Odor · detectedNOTIFIED BY TAXI CREW, WHEN AC WAS POWERED UP, ELECTRICAL BURNING SMELL STARTED, AC WAS VENTILATED WITH NO HELP. REPLACED SUPPLY COOLING FAN PER MM ALSO CLEANED FAN FILTER SCREEN. OPS CHECKED. BEARINGS FAILED IN FAN.SDR 2006UALA01353Skin · damagedFUSELAGE DAMAGED UNDER AFT CARGO DOOR. REMOVED DAMAGE. FABRICATED AND INSTALLED REPAIR DOUBLERS. REFERENCE UA EVA60460 AND SRM.SDR 2006UALA01222Aspirator · unserviceableDAMAGED ASPIRATOR AND HOLES IN THE OPPOSITE TUBE. ASPIRATOR CAUSED HOLES IN THE TUBE. ALSO, ASPIRATOR HAD A BAD SEAL WHICH MADE IT LEAK. PATCHED THE INFLATION CHAMBER AND REPLACED THE ASPIRATOR. ROOT CAUSE WAS ASPIRATOR PACKED IN SUCH A WAY AS TO ABRADE A HSDR 2006UALA00712Wire Harness · burnedFWD CARGO PIT LOADING SYSTEM IS POPPING SEVERAL C/B'S. FOUND WIRE HARNESS BURNED AT CLAMP BELOW FLOOR IN FWD PIT STA 650. FWD CARGO PIT LOADING SYS. IS INOP. FOUND WIRE HARNESS BURNT AT CLAMP BELOW FLOOR IN FWD PIT STA.650,JUST RH OF CENTERLINE. PERFORMED SDR 2006UALA00257Bushing · migratedNR 2 ENG PYLON INBOARD MIDSPAR FITTING OUTBOARD LUG BUSHING MIGRATED. NR 2 ENG PYLON INBD MIDSPAR FITTING OUTBD LUG BUSHING WAS FOUND MIGRATED. 4 EACH MIDSPAR BUSHINGS WERE FABRICATED PER SRM 54-53-90, REPAIR 3 & REPLACED PER GN-MM 01-0- 01-013.SDR 2006UALA00256Attach Angle · crackedFLOORBEAM TO WEB ATTACH ANGLE AT BS 246 APPROX LBL 48, COCKPIT ENTRY STEP IS CRACKED. CRACKED ANGLE REPLACED PER SRM. ANGLE FOUND DURING ROUTINE INSPECTION PROGRAM PER BOEING SERVICE BULLETIN 767-53-0093.SDR 2006UALA00255Stiffener · gougedL-1 DOOR CABLE HAS RUBBED A DEEP GOUGE IN FRAME STIFFENER AFT SIDE OF BS 303 FRAME AT STR 1R. GOUGED SUPPORT MEMBER REPLACED AND INSTALLED PER SRM.SDR 2006UALA00254Frame · corrodedAFT PIT FLOOR FRAME UPPER CHORD AT BS 1153, LBL 24 TO RBL 18 CORRODED ON TOP AND BOTTOM SURFACES. CORRODED FRAME ASSY PIECES REPLACED AND SPLICED PER SRM.SDR 2006UALA00200Seat Track · corrodedSEAT TRACK IN MAIN CABIN HAS AREAS OF GOUGES AND CORROSION STA 1197 + 142 TO 1213, 88 RBL. GOUGED SECTIONS OF SEAT TRACK REPLACED WITH NEW, PER SRM.SDR 2006UALA00199Seat Track · corrodedMAIN CABIN STA 1087, SEAT TRACK RBL 88 IS CORRODED. A 20 INCH SECTION OF CORRODED SEAT TRACK REPLACED WITH NEW, PER SRM.SDR 2006UALA00182Seat Track · gougedAFT CABIN SEAT TRACK GOUGED STA 1302 - 1325 LBL 11. SECTION OF AFT CABIN SEAT TRACK GOUGED BY UNKNOWN ORIGIN. REPAIRED PER SRM.SDR 2006UALA01186Latch · wornNR 3 LATCH EDGE MARGIN BEYOND LIMITS. REMOVED AND REPLACED NR 3 LATCH IAW B767 MM 25-65-98.SDR 2005UALA01138Flap System · malfunctionedLANDED ORD UNDER AMBER ALERT DUE TO TRAILING EDGE FLAP INDICATION PROBLEM.SDR 2005UALA01039Warning System · activatedABORTED TAKE OFF DUE TO FLAP CONFIGURATION MESSAGE.SDR 2004UALA00810Hinge · crackedRT INBD AFT FLAP EXTERNAL HINGE IS CRACKED AT THE MID FLAP AFT SPAR. REPAIRED FITTING WITH ANGLE REPAIR.SDR 2004UALA00809Floorbeam · corrodedCABIN FLOORBEAM UPPER SURFACE CORRODED, STA 808-813, RBL 57. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED FLOORBEAM SPLICE.SDR 2004UALA00767Pump · leakingLOST RIGHT HYDRAULIC SYSTEM EN ROUTE, CONTINUING TO DESTINATION. LOSS OF PRESSURE DUE TO FAILED NR 2 ENGINE DRIVEN PUMP. PUMP HAS INDICATION OF OVERHEAT CONDITION. NO ADDITIONAL DETAILS FROM OSV REPORTED.SDR 2004UALA00465Wire · damagedRIGHT SIDE AISLE NEXT TO MID GALLEY 1 EEL LIGHT STRIP SECTION OUT. *S/D* REPLACED CABLE AND SPLICED IN A NEW SECTION.SDR 2004UALA00152Light · inoperativeEXTERIOR EMERGENCY LIGHT INOP AT LT FUSELAGE AFT OF TRAILING EDGE. RELAMPED, CHECKED OK.SDR 2004UALA00047Wedge · dentedT/E WEDGE DENTED ON UPPER SURFACE OF NR 4 SLAT. MAJOR REPAIR. REPLACED WITH NEW T/E WEDGE.SDR 2003UALA00134Spar · crackedNR 2 PYLON UPPER SPAR WEB AT STA 180 IS CRACKED AT RADIUS OF CUTOUT. MAJOR REPAIR ACCOMPLISHED. REPAIRED UPPER SPAR WEB WITH DOUBLER AND ANGLE REPAIR.SDR 2003UALA00118Floorbeam · crackedL-ANGLE AND CHANNEL CRACKED BETWEEN STA 325 AND 347 AT RBL 42.69. L-ANGLE ATTACHES TO THE FORWARD END OF C-CHANNEL FLOORBOARD SUPPORT AT RBL 42.69 TO THE STA 325, FLOORBEAM. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW L-ANGLE AND NEW CHANNEL.SDR 2003UALA00107Spar · crackedNR 1 PYLON UPPER SPAR WEB CRACKED AT AFT CUTOUT, AFT OUTBOARD RADIUS. MAJOR REPAIR ACCOMPLISHED. REPAIRED WEB W/DOUBLER.SDR 2002UALA01403Drive Unit · failedWEATHER RADAR FAILED. THE ANTENNA DRIVE UNIT AND FLAT PLATE WERE REPLACED AND SYSTEM OPERATION RESTORED. SHOP TEST OF THE FLAT PLATE FOUND THE UNIT WITHIN SPECS. THE ANTENNA DRIVE UNIT FAILED SHOP TEST.SDR 2002UALA00451Battery · faultySMOKE SMELL AT DOOR 1L. FAULTY EMERGENCY EXIT LIGHT CHARGER AND BATTERY WERE REPLACED AT DOOR 1L.SDR 2000UALA00198O-Ring · leakingCENTER HYDRAULIC FLUID LOSS. AMBER ALERT. DIVERTED ORD. *S/D* FOUND FLUID LEAKING FROM CENTER PUMP FILTER MODULE DELTA PRESSURE SWITCH. REPLACED ''O'' RING.SDR 97UAL900755Airframe · vibrationCREW REPORTED VIBRATION AND RUMBLING AT RIGHT SIDE OF MID CABIN AREA. STARTED AROUND 320 KTS. RETURNED TO DUS. ETOPS. *S/D* SEQ NR 3272003: CREW FELT AND HEARD NOISE; SUGGESTED LOOSE EXTERIOR PANEL. A/C CK'D FOR OPEN OR LOOSE PNL, DOOR AND LNDG GR DRS, FOSDR 97UAL900727Tr Unit · intermittentWEATHER RADAR FAIL ON HSI. DUMPED FUEL, RETURNED TO FIELD, OVERWEIGHT LANDING. *S/D* FOUND WEATHER RADAR TRANSCEIVER FAILED. REPLACED WEATHER RADAR TRANSCEIVER.SDR 97UAL900475Bypass Valve · failedWHEN RETRACTING FLAPS, TE DISAGREE MSG APPEARED WHEN FLAP HANDLE WAS MOVED FROM 5 DEG TO 1 DEG. RETURNED TO JFK. *S/D* A FAULTY TRAILING EDGE FLAP POWER DRIVE UNIT BYPASS VALVE PREVENTED AFT FLAPS FROM RETRACTING TO THE COMMANDED POSITION. THE FLAP/SLAT EL