N644UA
Service difficulty reports · 376
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N644UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N644UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2015100594570Frame · corrodedCORROSION IN AFT CARGO COMPARTMENT ON FRAME 1197.66 T CAP LOWER SURFACE RBL 38 AT NUTPLATE. R & R T CAP AT BS 1197.66, LBL 46 TO RBL 46 IAW SRM 51-40-02 & DWG 146T1226.SDR CALA2015092594397Shear Tie · corrodedMAJOR REPAIR, AFT PIT STATION 1220, SHEER TIE CORRODED AT BL 0. SHEAR TIE WAS REPLACED IAW SRM 51-40-05, SRM 51-30-01 & DWG 140T2102.SDR CALA2015092294390Shear Tie · corrodedCORROSION BS 1540, RBL 6 AFT CARGO FLOOR BILGE SHEAR TIE. R & R SHEAR TIE IN AFT CARGO BS 1540, RBL 6 IAW SRM 51-40-02 & DWG 146T122 2 & 140T2102.SDR CALA2015092294389Shear Tie · corrodedCORROSION BS 1540, LBL 6 AFT CARGO FLOOR ON WEB & SHEAR TIE. CORROSION ON SHEAR TIE R & R IAW SRM 51-40-02 & DWG 146T1222 & 140T2102. NO CORROSION NOTED ON WEB.SDR CALA2015072894164Oxygen Mask · no testDURING OXYGEN MASK MANUAL DROP TEST MASK BOX DOORS AT 7HC, 8AB & 34KJ DID NOT OPEN IAW AMM 35-21-00 STEP 2E. SEATS 7HC, 8AB ADJUSTED. SEAT 34KJ CURRENTLY DF398. DROP TEST GOOD ON 7HC & 8AB.SDR CALA2015072894163Oxygen Gen · missingDURING OXYGEN MASK MANUAL DROP TEST THE AFT LEFT FLIGHT ATTENDANT MASKS DROPPED & IT WAS NOTED THAT THE OXYGEN GENERATOR WAS MISSING. REPLACED OXYGEN MODULE LEFT AFT POSITION IAW AMM 35-21-10. TEST OF PASSENGER OXYGEN MASKS AMM 35-21-00. OPERATIONAL CHECKEDSDR CALA2015072894160Lanyard · missingDURING OXYGEN MASK MANUAL DROP TEST, THE AFT RIGHT FLIGHT ATTENDANT MASKS DROPPED & IT WAS NOTED THAT THE ACTIVATION LANYARD WAS MISSING & THAT THE MASK LANYARD RINGS WERE NOT ATTACHED TO THE OXYGEN GENERATOR FIRING PIN. IAW AMM 35-21-00 STEP 2E. INSTALLED ASDR CALA2015072494157Power Supply · inoperativeSEAT MOUNTED EMER EXIT LIGHTS INOPERATIVE FROM SEAT ROWS 19 RT - 22 RT. REPLACED POWER SUPPLY M1209 IAW MM 33-51-07. OPERATIONS CHECKED NORMAL.SDR CALA2015072494156Battery · dischargedEMERGENCY EXIT LIGHT, EXIT SIGNS INOPERATIVE AT 2 EA LT OVERWING EXIT DOORS. REPLACED BATTERY M1559 IAW MM 33-51-07. OPERATIONS CHECKED NORMAL.SDR CALA2015072494155Battery · dischargedEMERGENCY EXIT FLOOR, EMER EXIT INOPERATIVE. JUST FWD OF MID SEAT ROW 19. REPLACED BATTERY M1559 IAW MM 33-51-07. OPERATIONS CHECKED NORMAL.SDR CALA2015072494154Battery · dischargedEMERGENCY EXIT FLOOR EMER EXIT INOPERATIVE AT MID LT LAVATORY. REPLACED BATTERY M1559 IAW MM 33-51-07. OPERATIONS CHECKED NORMAL.SDR CALA2015032693484Connector · unsecureMID LAVATORY 111 LT SIDE EMER EXIT LIGHT STRIP IS INOPERATIVE. SECURED CONNECTION. OPERATIONS CHECKED NORMAL.SDR CALA2014112492742Connector · unsecureEMERGENCY EXIT LIGHT INOPERATIVE AT AFT GALLEY FLOOR. SECURED CONNECTION. OPERATIONS CHECKED NORMAL.SDR CALA2014090392048Fastener · corrodedDURING LIGHTNING STRIKE INSPECTION IAW SMC 179 FOUND CORRODED HARDWARE LOCATED BELOW THE PILOT'S FWD NR 1 WINDSHIELD CLEANED LIGHT CORROSION & PAINTED IAW GPM 5-0-4-024.SDR CALA2014043090939Iru · malfunctionedIRS 3 ON POS IAW 2 - 4 SHOWED AN INCREASING ACTUAL MILEAGE THROUGHOUT THE FLIGHT. DIS OF IRUS WAS GROSSLY DIFFERING IN BEARING. UP TO 140 DEGREES DIFFERENCE RT INERTIAL IAW UNIT FAILS REMOVAL CHECK IAW FIG 107B, REPLACED RT IRU IAW AMM34- 21-401. ALSO PERFOSDR CALA2014042190885Light · inoperativeEXTERIOR EMERGENCY LIGHT AT DOOR 1LT IS INOPERATIVE. RELAMPED EXT DOOR 1LT EMERGENCY LIGHT, OPERATIONS CHECK OK IAW MM 33-51-00.SDR CALA2014042190884Latch · out of sequenceWHILE PERFORMING TASK CARD 682205001 AFT CARGO DOOR OPERATIONS CHECK, CARGO DOOR LOST POWER, BITE CHECKED PSEU F LAGGING SENSOR S209. FOUND LATCH ACT OUT OF SEQUENCE. ONLY RETRACTS HALFWAY, WILL NOT RETRACT ELEC OR MANUALLY TO LIFT DOOR SO IT CAN BE CLOSED.SDR CALA2014031990641Valve · faultyFUEL BURNS FROM RT TANK WITH RT CTR PUMP ON. WITH CROSS FEED VLV OPEN & LT CTR PUMP FEEDING RT ENG, NO MORE FUEL BURNS FROM RT TANK. APPEARS RT CTR PUMP DOES NOT OVERRIDE RT MAIN TANK PUMPS TO FEED THE RT ENG. PROBLEM FOUND TO BE THE RT WING OTBD FILL VLV, SDR CALA2014030790554Fuel · leaking1 FUEL LEAK FROM VICINITY OF LT ENG 2.5 BLEED VLV.SDR CALA2014022590471Valve · out of adjustFWD EQUIPMENT VLV EICAS & OVERHEAD EQUIPMENT COOLING VLV CYCLING ON & OFF, COMPLIED WITH MEL 2158U. CLOSED OVERBOARD VLV & DEACTIVATED IAW MEL 2158S. PERFORMED ADJUSTMENT TEST ON FWD EQUIPMENT VLV IAW AMM 21 58 00 CONFG 3, NO FAULTS NOTED ALL CHECKED GOOD.SDR CALA2014021790398Valve · malfunctionedFWD EQPT VLV EICAS & OVERHEAD EQPT COOLING VLV CYCLING ON & OFF. COMPLIED WITH MEL 2158U, CLOSED OVERBOARD VLV & DEACTIVATED IAW MEL 2158S.SDR CALA2014021190357Light · inoperativeRT WING NAV LIGHT BULB INOPERATIVE. PLACED RT GREEN NAV LIGHT ON MEL 3343B.SDR CALA2014012790242Skin · damagedFOUND CREASE ON FRAME 228 LAP SEAM STATION 222.4 TO 230.5 AT LAP SPLICE STRINGER 21L. THE DENT IS LOCATED IN THE RVSM CRITICAL AREA. REPAIRED IAW ECRA 5310-05971 REO 617052 REV B.SDR CALA2014012290208Battery Pack · dischargedLT SIDE FIRST & BUSINESS CLASS SEAT MOUNTED EMERGENCY LIGHTS INOPERATIVE. R & R EMERGENCY LIGHT BATTERY PACK LOCATED AT STATION 988, WL 203 & LBL 92 IAW B767 AMM 33-51-07 & OPERATIONS CHECKED GOOD ON NON-ROUTINE 23120.SDR CALA2014012090193Skin · dentedEVALUATED FUSE SKIN BETWEEN BS 320 - 478 LT BETWEEN STRINGER 21L TO 23L. FOUND TWO DENTS AT BS 471 & STRINGER 23L OUT OF LIMITS IAW SRM 53-00-01. DENT CROSSES STRINGER 23L, NO OTHER DEFECTS NOTED. CUT OUT DAMAGED AREA OF SKIN AT BS 471 & STRINGER 23L. FABRSDR CALA2014012090192Skin · dentedRT FUSELAGE SKIN DENTED AT STATION 654+66, STRINGER 29R. EVALUATED DENT & FOUND TO BE WITHIN LIMITS OF SRM 53-00-01. DENT WIDTH 2.65, DEPTH.054 & A OVER Y RATIO 49. DENT IS SMOOTH & CRACK FREE, OK TO ARCHIVE. ^18JAN GSO RPR RE-EVALUATED DENT AT S CHECK & FOSDR CALA2013112593252Valve · openFWD EQUIPMENT VLV IN THE OPEN POSITION.SDR CALA2013110892745Window · damagedLOUD SQUEAL COMING FROM CAPTAINS SIDE WINDOW. INTERIM REPAIR ACP IAW MM.SDR CALA2013101792148Actuator · leakingNR 2 ENG VSV ACTUATOR LEAKING FUEL FROM SIDE COVER. REMOVED & INSTALLED NR 2 ENG VSV ACTUATOR IAW AMM.SDR CALA2013100891842Valve · blownAPU SURGE VALVE HAS DUCT THAT IS BLOWN.. REPLACED SURGE VALVE & DUCT. APU OPERATION NORMAL.SDR CALA2013100891841Pressure Switch · faultyAPU AUTO SHUTDOWN ECU SHOWS "GEN FILTER" IN 2 OF THE LAST 4 SHUTDOWNS. IAW FIM49-11-00 CONF 2 PG 146 ITM2 SWITCH NEEDS TO BE CHECKED FOR RESISTANCE. PCN 481-1503 ORDERED. IAW AMM 49-27-15, AMM 49-27-03, AMM 49-27-04, CHECKED CHIP DETECTOR FOUND OK. REPLACSDR CALA2013093091561Switch · faultyUNABLE TO RESET RT UTILITY SWITCH. R & R RT UTILITY BUS SWITCH, OPERATIONS CHECKED NORMAL.SDR CALA2013092591444Circuit Card · not seatedFWD EQUIP VALVE EICAS AFTER ENGINE START. ACCOMPLISHED FIM TASK 21- 58-00 FIG 105 STEPS 1 THRU 3. RESEATED EQUIP IND CARD M867 & CHECKED ALL VALVE OPENINGS. RESEATED PLUG ON V91. MESSAGE & VALVE LIGHT CLEARED & NOW IN AUTO & STBY VALVE LIGHT REMAINS EXTINGUSDR CALA2013091091170Rivet · missingNR 2 ENG LT CORE COWL HAS 3 MISSING RIVETS BETWEEN 8 & 9 O'CLOCK POSITION.SDR CALA2013090991142Valve · out of positionFWD EQUIPMENT VALVE MESSAGE ON EICAS. EQUIPMENT COOLING IN AUTO POSITION ACP'D P61 EQUIPMENT COOLING GROUND TEST. SMOKE & OVERHEAT MESSAGES SHOWN IAW TEST & SMOKE LIGHT OVERHEAD. VALVE LIGHT EXTINGUISHED ONCE VALVES REPOSITIONED. VALVE LIGHT REMAINED OUT ASDR CALA2013090591027Computer · malfunctionedRT EICAS STATUS MESSAGE AFTER LANDING. REPLACED EICAS COMPUTER IAW AMM & TESTED SATISFACTORY.SDR CALA2013082390698Seal · missingREPORT OF PIECE OF RUBBER COMING OFF WING DURING LANDING. FOUND ON RT AILERON INBD SIDE, UPPER SEAL MISSING REPLACED SEAL WITH PN 10.60754-221 IAW AMM 27-10-00.SDR CALA2013082190623Warning Message · illuminatedFORWARD CARGO DETECTOR 1 STATUS MESSAGE WILL NOT CLEAR.SDR CALA2013082090607Amplifier · faultySATCOM VOICE. ACCOMPLISHED MM23-25-00 FAULT ISOLATION. 'HGA HPA INACTIVE' DISPLAYED ON CDU. VERIFIED POWER AT HPA. M1782, HGA HPA HAS 'POWER SUPPLY FAULT' LIGHT ILLUMINATED. REPLACED HPA PER MM. TESTED SYSTEM PER MM, OPS CHECKED NORMAL.SDR CALA2013081990550Computer · failedEICAS DISAGREE STATUS MESSAGE WILL NOT CLEAR ON LOWER DISPLAY. FOUND RT EICAS COMPUTER FAILING. ITEM TRANSFERRED IAW 3141H. REPLACED EICAS COMPUTER AND LOADED OPC & OPS SW REF MM, GROUND TEST NORMAL.SDR CALA2013081390425Warning Message · illuminated"AILERON LOCK" ILLUMINATED AT LOW SPEED. EICAS MESSAGE AILERON LOCKOUT DISPLAYED. OTBD AILERONS DID NOT INDICATE NORMAL-LOCKED OUT-BOTH. CARRIED OUT TEST IAW MM 27-11-44 & FIM 27-11-00 ALL OPS & INDICATIONS NOW OK.SDR CALA2013072990042Fastener · missingWALKAROUND MULTIPLE FASTENERS LOOSE, MISSING UNDERWING PANELS BOTH SIDES, OTBD EA MLG STRUT. INSTALLED NEW FASTENERS ON UNDERWING PANELS.SDR UALA2013071805047Seal · leakingLEFT ENGINE SHOWS SIGNS OF OIL LEAKAGE. FOUND NR 1 ENG STARTER QUAD COUPLING SEAL LEAKING. REPLACED SEAL AND REFITTED QUAD COUPLING IAW AM. LEAK TEST ACTIONED IAW AMM 71-00-00, TEST 5 OK. NO LEAKS OBSERVED.SDR UALA2013071805046Altimeter · malfunctionedCAPTAIN'S ALTIMETER FROZEN. PERFORMED FUNCTIONAL TEST OF THE LEFT ADC TEST PASSED ALSO PERFORMED TEST 30 IAW AMM, TEST PASSED, NO FAULT NOTED AT THIS TIME.SDR UALA2013071504920Door · unsecureRAM AIR TURBINE UNLOCKED. FOUND RAT DOOR EXTENDED 1 .5". CYCLED RAT. ALL INDICATIONS NORMAL.SDR UALA2013071204894Transceiver · faultyNR 2 VHF HAS LOUD, STATIC HUM. REPLACED NR 2 VHF TRANSCEIVER.SDR UALA2013070904784Oil System · leakingOIL DRIPPING FROM LT ENGINE. BOTTOM HALF OF TAILPIPE COVERED IN OILY SHEEN. CLEANED OIL FROM AREA AND BREATHER OUTLET HOLE. OPENED CORE COWL AND NO ACTIVE LEAK NOTED. COMPLIED WITH OIL CONSUMPTION CHECK REF AMM. NO EXCESS OIL CONSUMPTION NOTED ON PLN OIL SDR UALA2013062704501Fan · failedSTATUS MESSAGE AFT EQUIPMENT EXHAUST FAN NR 1 DISPLAYED ON STATUS PAGE. PERFORMED TROUBLESHOOTING IAW FIM 21-26-00. FOUND CIRCUIT BREAKER FOR EQUIPMENT COOLING FAN NR 1 TRIPPED, UNABLE TO RESET. REPLACED RECIRCULATION FAN, OPS CHECKS GOOD.SDR UALA2013062504408Lamp · inoperativeEMERGENCY AISLE LIGHT AT ROW 38KJ INOPERATIVE. REPLACED LAMP IAW AMM. OPS CHECKED NORMAL.SDR UALA2013062504407Lamp · inoperativeEMERGENCY AISLE LIGHT AT ROW 35AB IS INOPERATIVE. REPLACED LAMP, OPS CHECKED NORMAL.