N644UA
Service difficulty reports · 376
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N644UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N644UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013062504406Lamp · inoperativeEMERGENCY SLIDE LIGHT AT R2 DOOR INOPERATIVE. REPLACED LAMP IAW AMM, OPS CHECKED NORMAL.SDR UALA2013062504405Lamp · inoperativeEMERGENCY SLIDE LIGHT AT L1 DOOR INOPERATIVE. REPLACED LAMP IAW MM 33-51-06-902-082. OPS CHECKED NORMAL.SDR UALA2013062104343Oxygen Mask · unwanted deployCABIN OXYGEN MASK DEPLOYED AT 19K. REPACKED OXYGEN MASK IAW MM 35-21-00-501 & 35-21-10-532-116.SDR UALA2013061704192B-Nut · looseDURING WALKROUND CHECK, NOTICED HYD LEAK ON RT MAIN GEAR BOGIE TILT ACTUATOR. FOUND HYD CONNECTION B-NUT LOOSE. NUT TIGHTENED CORRECTLY. OPS TESTED GOOD. NO LEAKS. OK FOR SERVICE.SDR UALA2013061404133Starter · failedDURING LEFT ENGINE START, NO N2 ROTATION, HAD GOOD DUCT PRESSURE DROP AND START VALVE INDICATION, TRIED TWICE, NO HELP, RESET "D19" CIRCUIT BREAKER NO HELP, NO N2 ROTATION. REPLACED STARTER IAW MM. REPLACED STARTER VALVE MM. PERFORMED MOTORING OF ENGINE 1.SDR UALA2013060403870Line · leakingRIGHT ENGINE HYDRAULIC LEAK FROM AFT STRUT. ACCOMPLISHED PERMANENT REPAIR IAW DWG 272T3100 AND IAW MM 20-10-09. ACCOMPLISHED LEAK CHECK ALL NORMAL.SDR UALA2013052203558Audio Panel · faultyCAPTAIN'S AUDIO PANEL NOT ILLUMINATED. REPLACED CAPTAIN`S AUDIO CONTROL PANEL IAW MM, OPS OK.SDR UALA2013051303290Control Panel · faultyCAPTAIN'S RADIO LOUD SIDE TONE EVERY TIME KEYED. REPLACED CAPTAIN`S AUDIO CONTROL PANEL.SDR UALA2013050903244Light · inoperativeBUSINESS CLASS CROSS AISLE LIGHT INOP IN FULL OK IN DIM. RELAMPED OKAY.SDR UALA2013043003015Blade · nickedNR 1 ENGINE FIRST STAGE FAN BLADE NICKED ON LEADING EDGE APPROX 12 INCHES FROM OUTBOARD END WITH A DEPTH OF .010. ACCOMPLISHED FIRST BLEND ON BLADE IAW AMM 72-31-02. ACCOMPLISHED HFEC AS REQUIRED REF NDT MANUAL PART 6 72-31-401. NO CRACKS FOUND.SDR UALA2013032701971Computer · inoperativeF/O'S HEADING FLIGHT DIRECTOR INOPERATIVE. REPLACED RIGHT FCC, SYSTEM CHECKED OK PER MM 22-10-00, AIRCRAFT IS AUTOLAND CAPABLE.SDR UALA2013031401565Computer · failedRIGHT EICAS COMPUTER SOFTWARE LOADING FAILURE. REPLACED RIGHT EICAS COMPUTER AND TESTED FOUND NORMAL.SDR UALA2013031401550Valve · failedNR 2 ENGINE FAN AIR VALVE PNEUMATIC HEALTH CHECK FAILED AS PER FCD 3611-01233. NR 2 ENGINE FAN AIR VALVE REPLACED & BITE TEST CARRIED OUT AS PER AMM 36-11-16 & RESULT NORMAL.SDR UALA2013031401549Shutoff Valve · failedNR 2 ENGINE HPSOV PNEUMATIC HEALTH CHECK FAILED AS FCD 3611-01233. NR 2 ENGINE HPSOV PNEUMATIC HEALTH CHECK FAIL AS FCD 3611-01233 NR 2 ENGINE HPSOV REPLACED & INSTALLATION TEST CARRIED OUT AS PER AMM. RESULT NORMAL.SDR UALA2013022601167Warning Message · false activationFORWARD EQUIPMENT VALVE EICAS MESSAGE. PERFORMED FIM TASK 21 58 00 FIGURE 104. NO FAULTS FOUND, SYSTEM CHECKED GOOD. OK TO CONTINUE.SDR UALA2013011800321Strut · crackedINSPECTION FOUND ONE INCH CRACK AFTER STRESS RELIEF AND FPI, WELDED STRUT IAW 72-54-01 RU02 REPAIR C.SDR UALA2013010900141Connector · disconnectedEMERGENCY CEILING FLOOD LIGHT INOPERATIVE 13AB RECONNECTED CONNECTOR, OPERATIONAL TESTED GOOD.SDR UALA2013010900140Light · inoperativeEMERGENCY LIGHT INOPERATIVE AT MID LAV LEFT AISLE. REPLACED LIGHT. TESTED OK. ACCOMPLISHED IDT INSPECTION OF REPLACED FLOOR EMERGENCY LIGHT STRIP.SDR UALA2013010700083Valve · faultyFWD CABIN TEMP EICAS, UNABLE TO OPEN VALVE EVEN IN MANUAL. PULLED CIRCUIT BREAKERS H2 & H5. REPLACED THE AUXILARY FORWARD TRIM AIR MODULATING VALVE (V152) IAW AMM. ACCOMPLISHED OPS TEST IAW AMM, ALL CHECKED GOOD.SDR UALA2012122107359Motor · inoperativeHYDRAULIC MOTOR GENERATOR (HMG) INOPERATIVE AND DEACTIVATED. HYDRAULIC MOTOR GENERATOR (HMG) HAS BEEN DEFERRED IN COMPLIANCE WITH MEL CARD 29060. REACTIVATED SYSTEM PER MEL 2911G AND 2425A.SDR UALA2012121907294Sensor · faultyFLIGHT DECK TEMP CONTROL PROBLEMS. REPLACED FLT DECK ZONE TEMP SENSOR PER MM 21-61-08 & REPLACED FLT DECK ZONE DUCT SENSOR, BOTH SENSORS BITE TEST GOOD.SDR UALA2012120607068Controller · faultyNEED TO REPLACE ZONE TEMP CONTROLLER DUE TO FWD, MID, ZONE TEMP FAULT. VERY ERRATIC ON ECS PAGE. VERY ERRATIC ON ECS PAGE. REPLACED ZONE TEMP CONTROLLER. FWD AND MID CABIN TEMPS ROSE TO 76 AFTER 30 MIN AT 69. MOVED CTRL SLIGHTLY, NOW BACK TO 69. FWD AND SDR UALA2012120306904Modulating Valve · faultyCOCKPIT COLD. COCKPIT TRIM AIR VALVE IND SHOWS FULL HOT AND COLD AIR IS BLOWING INTO COCKPIT. REMOVED AND REPLACED FLT DECK TRIM AIR MODULATING VALVE, OPS CHECK GOOD.SDR UALA2012113006879Regulator Valve · faultyDIFFICULT TO CONTROL CABIN AND COCKPIT TEMPS, HAD TO SWITCH BETWEEN AUTO AND TRIM AIR OFF. REPLACED TRIM AIR REG VALVE. BECAUSE NO FAULTS WERE FOUND, REMOVED BOTH TRIM AIR CHECK VALVES, FOUND OK AND INSTALL PROPER, ALSO CHECKED SENSE LINE ON TRIM AIR REG VALSDR UALA2012113006878Controller · faultyFLT DECK TEMP CONTROL FULL WARM AND VALVE SHOWS FULL WARM BUT ONLY PUTS OUT COLD AIR. SAMC TEXT: PER VERBAL FROM FLT CREW. COLD TEMPS IN BOTH COCKPIT AND CABIN. STANDBY W-NO HELP. STANDBY ON DID HELP BRING TEMPS UP. ACP BITE CHECKS ON ZONE TEMP AND AUX TSDR UALA2012111306541Cover · missingDURING PRE DEPARTURE WALKAROUND FOUND UPPER RUDDER HINGE COVER MISSING. NEEDS 1 EA 173T2011-7 BOND, 2 EA FASTENER HL97DU6 REF IPC 55-40-55-0001 ITEMS 774, 777. WILL REQUIRE 2 SHIFT SLOT MUST REMOVE UPPER AND PARTLY LOWER PANEL ABOVE AND BELOW UPPER RUDDER HISDR UALA2012101505863Line · leakingLEFT HYD QTY EICAS INFLIGHT WITH RF 0.48. FOUND HYD LINE IN LEFT SAIL TAIL LEAKING. INSTALLED NEW LINE AND OPS CHECKED. NO LEAKS.SDR UALA2012090404935Blocker Door · damagedLEFT ENGINE BLOCKER DOOR FOUND DAMAGED AT THE 3 O'CLOCK POSITION. RADIAL CRACK APPROX 3 INCHES. BLOCKER DOOR AND DRAG LINK REMOVED IAW MM 78-31-15. INSTALLED BLOCKER DOOR AND DRAG LINK IAW AMM 78-31-14 AND AMM 78-31-15. OPS CHECKED OK.SDR UALA2012083004870Sensor · faultyAIRSPEED INDICATOR FLUX, RTFL. ACCOMPLISHED LEFT ADC BITE PROC PER FIM 34-12-00. THE FAULT DISPLAY INDICATES 1. PLEASE REPLACE LEFT ANGLE OF ATTACK SENSOR PER MM. RPL'D LT ANGLE OF ATTACK PER MM, OPS NORMAL. REPLACED LEFT ADC PER MM. ALL INDICATIONS NOW SDR UALA2012082004636Slide · low pressureDOOR 1R SLIDE PRESSURE LOW. REPLACED SLIDE. ACCOMPLISHED PER MM AND R II METHOD 1 PIN. REMOVED SLIDE WITHIN DATE AND GIRT BAR IS ALIGNED AND PRESSURE IS NORMALSDR UALA2012081704590Brake · failedNEED RIGHT TILLER TO TAXI, PULLS LEFT. TROUBLESHOT PER FIM 32-51-00. REPLACED NR 6 BRAKE PER AMM.SDR UALA2012080904316Bracket · crackedAT DEPARTURE TIME, CAPTAIN UNABLE TO SECURE SLIDING COCKPIT WINDOW. SUPPLEMENTAL DATA UPDATE, ADJUSTED NR 2 CAPTAIN WINDOW, CHECK NO LEAK. LOWER CARRIAGE BRACKET ITEM NR 365 P NR 141T4883-501, -9, OR -15 IS CRACKED AT CAPTAIN'S SLIDING WINDOW. SEE IPC 56-11SDR UALA2012081004351Window · stuckAT DEPARTURE, CAPTAIN UNABLE TO SECURE SLIDING COCKPIT WINDOW. ADJUSTED NR 2 CAPTAIN WINDOW, CHECKED, NO LEAKS.SDR UALA2012080804306Isolation Valve · faultyNR 2 ENGINE THRUST REVERSER FAULT. REPLACED NR 2 THRUST REVERSER MOTORIZED ISOLATION VALVE IAW.SDR UALA2012071603834Computer · failedAUTOTHROTTLE WILL NOT STAY ENGAGED IN VNAV OR FLCH. REMOVED AND REPLACED THRUST MANAGEMENT COMPUTER AS PER AMM, OPS CHECKED GOOD. PERFORMED TEST 30 AS PER AMM, ACFT RESTORED TO FULL CAPACITY CAT STATUS.SDR UALA2012043002558Line · damagedPOTABLE WATER SUPPLY LINE RUNNING FROM STA 1375 TO 1550 HAS A BURN MARK ASSOCIATED WITH RIBBON HEATER TAPE B110 AT BS 1420. REMOVED AND REPLACED DAMAGED WATER LINE IAW AMM 38-10-00 AND SRM 51-40-02. PERFORMED LEAK CHECK TEST IAW 38-10-00. CHECKED GOOD. HEASDR UALA2012043002557Skin · misrepairedEXTERNAL FUSELAGE SKIN AT BS 1430-1461 JUST BELOW CARGO DOOR WAS FOUND MISREPAIRED. REPAIRED SKIN IAW EA PT67-53-003 AND ECRA 5360- 01191. ACCOMPLISHED NDT OF AREA. NO CRACKS FOUND. ACCOMPLISHED INSURANCE CUT. FABRICATED AND INSTALLED EXTERNAL FILLER, DOUBSDR UALA2012043002556Skin · dentedDENT ON FUSELAGE AT BS 331 STRINGER S30L FOUND OUT OF SRM LIMITS. TRIMMED OUT DAMAGE IAW EA PT67-53-005 AND ECRA 5310-05483. ACCOMPLISHED NDT. NO CRACKS FOUND. ACCOMPLISHED INSURANCE CUT PER EA FABRICATED AND INSTALLED EXTERNAL DOUBLER AND FILLER REPAIR RESDR UALA2012043002555Light · inoperativeEMERGENCY EXIT AISLE LIGHT AT SEATS 37-38 RT SIDE IS INOP. REPLACED SEAT EMERGENCY EXIT LIGHT REF AMM 33-51-10. OPS CHECKED GOOD.SDR UALA2012043002554Floorbeam · corrodedFWD CABIN BS 287 AND RBL 20, FLOORBEAM TEE CORRODED. REMOVED DAMAGE AND FABRICATED AND INSTALLED TEE REPAIR REF SRM 53-00-051 FIG 201 REPAIR 1.SDR UALA2012043002553Floorbeam · corrodedFWD CABIN BS 287 FLOORBEAM UPPER TEE CORRODED. REMOVED DAMAGED TEE AT BS 287 RBL 37-70 IAW SRM 53-00-51 REPAIR 1. ACCOMPLISHED NDT FOR CRACKS. NONE FOUND. FABRICATED AND INSTALLED UPPER TEE REPAIR REF SRM 53-00-51 FIG 201 REPAIR 1.SDR UALA2012043002552Light · inoperativeEMERGENCY EXIT LIGHT AT SEAT 34AB INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSY FOR SEAT REF AMM 33-51-10. OPS CHECKED GOOD REF AMM33- 51-00.SDR UALA2012042702514Spar · crackedNR 1 PYLON FWD UPPER SPAR WEB OUTBOARD DRAIN HOLE CRACKED AT OUTBOARD DRAIN HOLE AT NAC STA 156. STOP DRILLED CRACK. ACCOMPLISHED NDT, NO CRACKS FOUND. FABRICATED AND INSTALLED DOUBLER REPAIR IAW SRM 54-53-01 REPAIR 10.SDR UALA2012042702513Floorbeam · corrodedFWD CABIN BS 287 FLOORBEAM UPPER TEE CORRODED. REMOVED DAMAGED TEE IAW SRM 53-00-51 NR 1. ACCOMPLISHED NDT, NO CRACKS FOUND. FABRICATED AND INSTALLED UPPER TEE IAW SRM 53-00-51 FIG 201 REPAIR NR 1. MAJOR REPAIR.SDR UALA2012042702512Light · inoperativeEMERGENCY EXIT LIGHT AT SEAT 34AB INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSY FOR SEAT. OPS CHECKED GOOD.SDR UALA2012042702511Terminal Block · damagedWINDOW EICAS MESSAGE DISPLAYED. INOPERATIVE LIGHT DID NOT EXTINGUISH WHEN SWITCH WAS RECYCLED TO OFF THEN ON. BITE CHECKED, CONTROLLER FAULTED. FOUND DAMAGED TERMINAL BLOCKS ON WIRE HARNESS, HARNESS BRITTLE, TROUBLESHOOTING FOUND RECESSED PINS 2 AND 3 ON COSDR UALA2012042602506Frame · corrodedAFT CARGO PIT, FRAME AT BS 1241 AND STR 34R, INNER CHORD CORRODED. REMOVED CORROSION & FOUND MATERIAL LOSS OUT OF SRM LIMITS. REMOVED EXISTING TEE. FABRICATED & INSTALLED NEW TEE. MAJOR REPAIR.SDR UALA2012042602502Stringer · misrepairedSTRINGER 38 LEFT MISREPAIRED AT BS 1453. FABRICATED AND INSTALLED STRINGER REPAIR, SRM 53-00-03 FIG 201 REPAIR 2 DETAIL 4. MAJOR REPAIRSDR UALA2012042602500Lamp · inoperativeEMERGENCY EXIT LIGHT ASSY L-288 AT R1 DOORWAY INOPERATIVE. REMOVED AND REPLACED LAMP. OPS CHECKED GOOD.SDR UALA2012042502495Frame · corrodedAFT CARGO PIT, FRAME INNER CHORD CORRODED AT BS 1197+88 AND S34L. REMOVED DAMAGE AND FOUND MATERIAL LOSS OUT OF SRM LIMITS. REMOVED DAMAGED UPPER TEE SECTION IN ENTIRETY. FABRICATED AND INSTALLED NEW UPPER TEE REF SRM51-40-02.