N644UA
Service difficulty reports · 376
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N644UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N644UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010092203522Fairing · missingRT ENGINE OUTBOARD REVERSER HAS A PIECE OF MISSING FAIRING. FAIRING IS LOCATED AFT OF LOWER BLOCKER DOOR (5:30 O'CLOCK) AND MISSING PIECE IS 6.5 INCH LONG BY 2 INCH WIDE. REQUIRES PERMANENT REPAIR, PICTURES ON RVI WEB SITE. DEFERRED REVERSER INOP. APPLIED SPEESDR UALA2010080502837Brake · fireNR2 FWD BRAKE FAILED ON LANDING. AFTER SLIDE DEPLOYMENT AT DOOR 1R, REMOVED SLIDE ASSY AND CLOSED DOOR. REPLACED SLIDE-RAFT AT DOOR 1R. ALSO REPLACED BRAKE. OPS NORMAL.SDR UALA2010073002745Fuel Line · damagedNR 2 ENGINE FUEL LINE FROM FUEL-OIL COOLER 'FUEL OUT' LINE TO FUEL PUMP INSULATION DAMAGED. REMOVED FUEL LINE. COMPLETED INSTALLATION, LEAK CHECKED GOOD. REPLACED FUEL PUMP. OPS & LEAK CHECKED GOOD.SDR UALA2010072602649Lockout · malfunctionedL FMC FAILURE & STAB TRIM EICAS, RTFL. STAB TRIM LIGHT ON O/H AS WELL AS EICAS MESSAGE. REPLACED STAB TRIM - AILERON LOCKOUT MODULE. ACP MCDP TEST 65. TEST OK. ACCOMPLISHED STAB TRIM CONTROL OPS TEST IAW MM. ALL TESTS PASSED.SDR UALA2010071602552Selector Panel · malfunctionedLOWER EICAS TURNED PINK IN DESCENT. POSSIBLE PART "PANEL EICAS CONTROL". REPLACED EICAS DISPLAY SELECT PANEL, OPS CHECK ABOUT 3 HOURS, NO FAULTS & DISPLAY COLORS NORMAL.SDR UALA2010071202474Relay · defectiveY PWR AFTER TAKEOFF CYCLED UTIL BUSSES AND POWER RESTORED. REPLACED AIR-GND TIME DELAY RELAYS M1164 & M1163 WDM. ALSO SWAPPED ELEC SYS PNL ON P5 M10063 WITH ACFT 6457. ACP LOAD SHED CHECK GRND CHECKED NORMAL.SDR UALA2010070602398Module · faultyLEFT ENG DUCT LEAK LIGHT CAME ON, ON TAXI. REPLACED THE AIR SUPPLY BITE MODULE IAW MM. ACCOMPLISHED LEAK CHECK IAW MM.SDR UALA2010070602416Pin · bentLOSS OF GALLEY POWER. REPLACED THE RT ENGINE GENERATOR CIRCUIT BREAKER, NO HELP. REPLACED RELAY K101 & K103 AS A PRECAUTION. FOUND BENT PIN IN CONNECTOR D4034P PIN 25. STRAIGHTEN PIN-WIRE W018-069-22, CHECKS GOOD FROM M116 BUSS POWER CONTROL UNIT M116 CONNECSDR UALA2010062802302Window · leakingCAPT SLIDING WINDOW LEAK. HISSING LEAK ONLY BECAME EVIDENT AT 7.0 PSI DIFF PRESSURE. AREA OF HISSING COMING FROM AREA AROUND WINDOW LOCK LATCH HANDLE. CONFIRMED WITH AMT'S THAT PERFORMED INITIAL PRESSURE TEST A TYPO WAS MADE REGARDING PRESSURE READING DURINSDR UALA2010062802296Hose · disconnectedLT PACK BLEED LEAK LIGHT ON WITH LT PACK ON. LT ENG BLEED OFF. FOUND HOLE IN HOSE OFF ACM DUCT REPLACED.SDR UALA2010061602125Relay · failedNO GALLEY POWER IN FIRST AND COACH AFTER TAKEOFF. CYCLING RT UTILITY BUS RESTORES POWER. RPLCD RELAY K10109. REPLACED BPCU. ALSO REPLACED ELCU M225 AND M226, TESTS OKAY.SDR UALA2010060301934Receptacle · damagedRAMP PERSONNEL REPORTS GND POWER RECEPTACLE APPEARS DAMAGED. EXT POWER PINS WERE SEVERELY BENT AND TOUCHING THE ALIGNMENT SHROUD. STRAIGHTENED PINS AS BEST AS POSSIBLE. MAY NOT BE USEABLE AT NEXT STATION. RAMP SVC UNABLE TO CONNECT EXT PWR IN SFO DUE TO BENT SDR UALA2010060101864Seal · leakingNR 2 WINDOW ASSY AIR LEAKS (NOISY) POSITION 2 (2=2L ,5=2R). INTERIM REPAIR IAW MM. APPLIED TAPE TO WINDOW, NEED TO ACCOMPLISH PERMANENT REPAIR IAW AMM AT FIRST AVAILABLE MX OPPORTUNITY. OK IAW SAMC. REPLACED PRESSURE SEAL. OP CHK'D NORMAL.SDR UALA2010052501794Handle · out of rigCAPT WINDOW LEAK & SQUEAL IS LOUD & EXTREMELY DISTRACTING. NOISE COMING FROM STOWAGE HANDLE. RIGGED LOWER LINK ARM ASSY. ALSO FAYING SEALANT WAS APPLIED TO ENTIRE SEAL, PRESSURIZED ACFT AND NO LEAKS. CK'D ALL OTHER RIGS AND ALL FELL INTO LIMITS.SDR UALA2010052401742Bulb · faultyEXIT PATH LIGHT FLICKERING AT DOOR 1L. SECURED BULB, OPS CHK NORMAL.SDR UALA2010052601814Actuator · leakingRT NOSE WHEEL STEERING ACTUATOR LEAKING. REPLACED RT NOSE WHEEL STEERING ACTUATOR. OPS CHECKED AND LEAK CHECKED. OPS CHECKED GOOD AND NO LEAKAGE NOTICED.SDR UALA2010052401757Connector · dirtyEMERGENCY EXIT FLOOR STRIPS AND EXIT LIGHT AT DOOR 1L ON INTERMITTANTLY WITH SW IN ARM. CLEANED POWER SUPPLY CONNECTOR M1208, OPS CKS GOOD.SDR UALA2010052101714Charger · inoperativeSEVERAL EXT EMERGENCY EXIT LIGHTS INOP ON TEST. RELAMPED LIGHT ASSY AT FWD ENTRY DOOR & REPLACED BATTERY CHARGER AT POSITION M737. OPS CHECKED GOODSDR UALA2010050401505Generator · faultyAPU SHUTSDOWN. NO FAULT LIGHT. NO ABNORMAL INDICATIONS. IAW T-S REPLACED APU FLOW SENSITIVE MODULE, NO HELP. REPLACED GCU IAW AMM, NO HELP. REPLACED BPCU IAW AMM, NO HELP. RESTORED ORIGINAL UNIT. CKD GEN FEEDERS AND LUGS. ALL OK. RUN APU WITH 70 PERCENT OF LOSDR UALA2010022400691Indicator · faultyO-H FUEL PANEL-FUEL TEMP INOPERATIVE. REPLACED OVERHEAD FUEL QUANTITY PANEL. ACCOMPLISHED FUEL QUANTITY BITE CHECK.SDR UALA2010020100398Pressure Switch · unknownPUMP OFF AND LP LGT ON BUT NO EICAS MSG. TRIED S72 PRESSURE SWITCH NO HELP, TRIED OVERHEAD PANEL, NO HELP, REPLACED K190 CONTROL RELAY NO HELP. ISOLATED CIRCUIT BETWEEN S5 TO S72 & BOTH EICAS CMPTS, WIRES CHKS OK. REF FIM 28-22-00 FIG 111 BOX 2, 28VDC PRESENTSDR UALA2009122103948Light · damagedSEAT MOUNTED EMERGENCY LIGHT DISCONNECTED AND WIRES STOWED DUE TO INCOMPLETE REPAIR OF FOOT REST AT SEAT 8B. REPAIRED DISCONNECTED WIRES. LIGHT TESTS NORMAL.SDR UALA2009112503661Duct · rupturedON ARRIVAL FOUND WING ANTI ICE BLOW OUT PNL DISINTEGRATED AT THE LT WING STA 523AT. FURTHER T-S SHOWED COMPOSITE DUCT RUPTURED AT STA 523 AT JOINING METAL DUCT. REPLACED TAI DUCT. DISCONNECTED AND RECONNECTED SLAT CONTROL ROD AT BOTH ENDS OF SLAT NR 4. ACCSDR UALA2009112003627Anti-Ice Valve · malfunctionedEICAS MSG ENG ANTI-ICE DISPLAYED AND ENG ANTI-ICE VALVE LIGHT REMAINED ILLUM WITH SWITCH ON, POSITION 2. CREW COMMENTS: AFTER ENG START HAD TO CYCLE SWITCH SEVERAL TIMES AND BOOST POWER TO EXTINGUISH REPEAT. REPLACED NR 2 ENGINE ANTI-ICE VALVE, RAN ENGINE. SDR UALA2009102703345Sealant · damagedFUEL LEAK FROM L PACK BAY AT 20DPM. CENTER FUEL TANK UNDER PANEL 193PL LT WING TO BODY FAIRING STATION 955.10 REAR SPAR CENTER TANK FASTENERS LEAKING. FOUND LEAK AT AFT SPAR BELOW AND JUST FWD OF LOWER LEFT BATHTUB FITTING. FOUND INTERNAL LEAK, REMOVED DAMASDR UALA2009091802951Wire · sparksAFT GALLEY PIGTAIL P51 SPARKED WHEN REMOVED & C/B POPPED OUT. P51 PIGTAIL REPLACED. GALLEY CART OPS CHECK OKAY.SDR UALA2009090802798Potable Water · emptyNO WATER QUANTITY AND PRESSURE, RTFL. SHORTLY AFTER DEPARTURE, CREW NOTIFIED CHIDD AND SAM THAT THE POTABLE WATER SYSTEM APPEARED TO BE EMPTY. MAINT CONFIRMED NO WATER IN MID LAVS-GALLEYS AND AFT LAVS-GALLEYS. WATER QTY IND RESERVICED WATER AND BLED SYSTEM. SDR UALA2009083102737Control Panel · faultyNR 1 AUDIO SELECTOR PANEL LIGHTING FAULTY. CREW COMMENTS: LIGHTS ON ALL SELECTOR SWITCHES ON CAPTS VHF PANEL ARE INOP. 2ND OBSERVER FLIGHT & SERVICE INTERPHONE SWITCHES INOP. FLT INTERPHONE FROM FRONT TO COCKPIT DOES NOT WORK. REPLACED CAPT AUDIO SELECTORSDR UALA2009072002141Panel · damagedRIGHT SIDE WING LEADING EDGE SLAT NR 12 LINKAGE FAIRING PANEL NR 24 DAMAGED. SLATS OPERATE NORMALLY. PANEL REMOVED AND PLACED IN LOB BOX. REMOVED AND REPLACED SLAT NR 12 LINKAGE PANEL.SDR UALA2009072002138Computer · faultyRIGHT EICAS COMPUTER INOPERATIVE. REPLACED RT EICAS COMPUTER.SDR UALA2009042901251Valve · failedFUEL CONFIG MESSAGE. FLIGHT DIVERTED. REPLACED CHECK VALVE ASSEMBLY. NO UNWANTED FUEL TRANSFER NOTED.SDR UALA2009042801221Pump · faultyFUEL IMBALANCE. FLIGHT DIVERTED. FUEL CONFIG LIGHT ILLUMINATED DUE MORE THAN 2000 POUNDS DIFFERENCE BETWEEN RT AND LT MAIN TANKS WHILST FEEDING FROM THE CENTRE TANKS. CHKD STICK READINGS VERSES GAUGES-NO DISCREPANCY FOUND, PROCESSOR NO FAULTS OPS CHK PUMP INDSDR UALA2009041601106Indicator · fluctuatesFUEL QTY INDICATORS FLUCTUATING. RTFL. REPLACED FUEL QTY PROCESSOR. REPLACED COCKPIT FUEL QTY INDICATION PANEL. PERFORMED BITE. CHECKED OK.SDR UALA2009033100936Aspirator · leakingSLIDE ASPIRATOR BARREL LEAKING. CAUSE IS UNKNOWN. REPLACED ASPIRATOR.SDR UALA2009031000711Oxygen System · low pressureCREW OXYGEN PRESSURE BELOW 3SVC LIMITS (1.610 PSI). SERVICED CREW OXYGEN SYSTEM. OP CHECKS OKAY.SDR UALA2009030400711Oxygen System · low pressureCREW OXYGEN PRESSURE BELOW 3SVC LIMITS (1.610 PSI). SERVICED CREW OXYGEN SYSTEM. OP CHECKS OKAY.SDR UALA2009011500170Pump · faultyONE HOUR AFTER TAKEOFF, FUEL CONFIG LIGHT WITH RT TANK 4000 LBS LESS THAN LT. REPLACED RT FUEL OVERRIDE PUMP. OPS CHECK GOOD.SDR UALA2009031000076O-Ring · unserviceableLOW BOTTLE PRESSURE. LEAKING AROUND GAUGE ADAPTER. R & R O-RING.SDR UALA2009010600076O-Ring · damagedLOW BOTTLE PRESSURE. LEAKING AROUND GAUGE ADAPTER. R&R O-RING.SDR UALA2009010200024Hydraulic Line · leakingHYD LEAK FROM LT OTBD AILERON PCU HYD LINE. TUBE REPAIRED WITH FITTING. LEAK CHECK ACCOMPLISHED. LT HYD SYS SERVICED TO GREEN BAND.SDR UALA2008123007044Oven · contaminatedELECTRICAL ODOR IN CABIN. FLIGHT DIVERTED. DOOR AREA HEATER CB PULLED R12 ON OVERHEAD P11 PANEL TO SEE IF ODOR GOES AWAY. THERE IS NO SIGN OF ANY SMOKE. REPLACED RT AFT DOOR HEATER. WARMING OVEN DIRECTLY BELOW W51 HAD MELTED PLASTIC INSIDE CAUSING BURNED OSDR UALA2008122607013Oven · odorELECTRICAL ODOR REPORTED IN AFT GALLEY. NO ODOR WITH GALLEY POWER OFF. CHECKED IN CEILING ABOVE AFT GALLEY ALL OK. FOUND WARMING OVEN W51 HAD MELTED PLASTIC INSIDE AND STRONG BURNED ODOR. CLEANED OVEN. RAN FOR SEVERAL HOURS. CHECKED OK.SDR UALA2008122406990Slide · low pressureDOOR 1R PRESSURE GAUGE IS BELOW THE GREEN BAND. REPLACED SLIDE.SDR UALA2008121506889Switch · failedRIGHT ENG TAI PROBLEM. REPLACED RT ENG TAI PRESSURE SWITCH S525. RAN ENGINE AND OPS CHECK NORMAL. REACTIVATED SYSTEM.SDR UALA2008121006835Charger · faultyAPU AUTO SHUT DOWN. TAXI CREW TRIED STARTING IT SEVERAL TIMES WITH NO START, BIT OF APU CONTROLLER SHOWED NO ACCEL IN POSITION 1 AND OVERTEMP IN POSITION 4 THRU 5. REPLACE APU BATTERY CHARGER. APU SLOW TO GET TO SPEED AND DUCT PRESSURE 10 PSI.SDR UALA2008121006836Pressure Sensor · inoperativeLEFT AFT BOOST PUMP PRESSURE LIGHT INOP. REPLACED LEFT AFT BOOST PUMP PRESSURE SWITCH.SDR 2008UALA06294Shutoff Valve · malfunctionedRT BLEED FAULT. RTFL. REPLACING PRSOV. RIGHT ENGINE BLEED LIGHT ILLUMINATED WITH BLEED SWITCH ON. REPLACED PRSOV. ACCOMPLISHED IDLE RUN, BLEED PRESSURE NORMAL. BLEED SWITCH-NORMAL OPERATION.
SDR UALA2008111306194Relay · damagedRELAYS K417 AND K383 IN P-19 PANEL SHOW SIGNS OF OVERHEATING. REMOVED AND REPLACED RELAYS. PERFORMED A GOOD OPS CHECK OF THE NS-FSB SIGNS AND OPS CHECK OF L-1 DOOR.SDR 2008UALA06194Relay · damagedRELAYS K417 AND K383 IN P-19 PANEL SHOW SIGNS OF OVERHEATING. REMOVED AND REPLACED RELAYS. PERFORMED A GOOD OPS CHECK OF THE NS-FSB SIGNS AND OPS CHECK OF L-1 DOOR.SDR 2008UALA06193Wire Harness · corrodedAPU POWER CABLE (W236-006-1-0) HAS A CORRODED SPLICE CAUSING OVERHEAT AT BS 1783-1800 IN EMPENNAGE COMPARTMENT BELOW HORIZ STAB RIGHT SIDE. REMOVED AND REPLACED HARNESS ASSY. INSTALLED ASSOCIATED SPLICES FOR HARNESS. OPS CHECK OF APU GENERATOR GOOD.
Back to N644UA