N645GT

Service difficulty reports · 716

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N645GT' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR UIEA2019050104097Oil System · lowAPU FAULT EICAS MSG, APU DIDN'T START AFTER 3 ATTEMPTS.(<P>SERVICED THE APU WITH 1 QT. OPS CHECK GOOD IAW AMM 49-00-00.</P>)May 1, 2019 · N645GT · Boeing 767324 · APU Oil SystemSDR UIEA2019050104096Switch · intermittentFUEL DOOR SWITCH INTERMITTENT. NO CENTER PUMP INHIBIT.(<P>REMOVED AND REPLACED FUEL DOOR SWITCH PER WDM 20-30-12. OPS CHECK GOOD.</P>)Apr 29, 2019 · N645GT · Boeing 767324 · Aircraft Fuel Distribution SystemSDR UIEA2019042904069Pump · malfunctionedR AFT FUEL PUMP EICAS, RIGHT AFT FUEL BOOST PUMP CB POPPED. QRH COMPLETE. REPEAT WRITE-UP. (<P>TRANSFERRED FUEL PUMP TO MEL 28-22-01 MDDR 110840. PLACARD INSTALLED AND MAINT PROCEDURES C/W. AIRCRAFT RESTRICTED TO ETOPS 120.</P><P>LP 1079323-M2 FOUND B1 WIRE WApr 27, 2019 · N645GT · Boeing 767324 · Fuel Boost PumpSDR UIEA2019042603958Warning Message · false activationINTERMITTENT RIGHT PACK TEMPERATURE EICAS MESSAGE IN FLIGHT. (<P>PERFORMED FIM 21-51 FT 803 SYSTEM FAULTED TEMP CONTROL VALVE. PERFORMED TABLE B PROCEDURES, TEMP CONTROL VALVE OPS CHECK NORMAL. VERIFIED NO FAULTS NOTED. </P>)Apr 25, 2019 · N645GT · Boeing 767324 · Cabin Cooling SystemSDR UIEA2019042533932Wire Harness · failedRIGHT AFT FUEL PUMP FAILED. COMPLIED WITH QRH POCEDURES. REMOVED AFT FUEL PUMP RIGHT ACCESS PANEL AND DE PINNED D1540 PIN 2 TO INSPECT. RE-INSTALLED PINS AND CLOSED ACCESS PANELS. DMI 110638 REMAINS OPEN. REMOVED AND REPLACED WIRE HARNESS WO478 PER EO 67Apr 23, 2019 · N645GT · Boeing 767324 · Fuel System WiringSDR UIEA2019042633937Warning Light · false activationDURING TAXI, R PACK TEMP EICAS MESSAGE. RAN CHECKLIST. PACK CONTROL SELECTOR SET TO STBY, LT EXTINGUISHED.(<P>COLD NOT DUPLICATE. PERFORMED BITE CHECK IAW AMM 34-10-00.</P>)Apr 23, 2019 · N645GT · Boeing 767324 · Cabin Cooling SystemSDR UIEA2019042213919Pump · inoperativeRIGHT AFT FUEL PUMP INOP(<P>TRANSFERRED TO MEL 28-22-01 MDDR 110519 CAT 'C'. PLACARD INSTALLED. MX PROCEDURES C/W. AIRCRAFT RESTRICTED TO ETOPS 120. </P><P>LP 1047034 - M11: MEGGED WIRES W476-302B-16, 302R, 302Y, AND W580-168-14,169,170. RE-TORQUED K10702 & CApr 19, 2019 · N645GT · Boeing 767324 · Fuel Boost PumpSDR UIEA2019041983910Warning Message · false activationSTATUS MSG "WXR SYS". (<P>PERFORMED OPS CHECK OF WXR SYSTEM IAW B767 AMM 34-43-00. NO FAULTS FOUND AT THIS TIME. </P>)Apr 18, 2019 · N645GT · Boeing 767324 · Weather Radar SystemSDR UIEA2019041733863Relay · failedRIGHT AFT FUEL PUMP PRESSURE LIGHT ILLUMINATED. (<P>TRANSFERRED TO MDDR 110147 AS PER MEL 28-22-01 CAT "C". MAINTENANCE PROCEDURES C/W. AIRCRAFT RESTRICTED TO ER 120. </P><P>LP 1042361 - M4: R/R RIGHT FLT BOOST PUMP ASSY IN ACCORDANCE WITH AMM 28-22-03. (P/N: Apr 13, 2019 · N645GT · Boeing 767324 · Fuel Boost PumpSDR UIEA2019041503876Stowage Box · leakingPOSSIBLE O2 LEAK. REMOVED AND REPLACED 2ND OBSERVERS O2 MASK STORAGE BOX ASSYEMBLY IAW B767 AMM 35-11-51. OPS AND LEAK CHECK GOOD.<BR /></P>)Apr 12, 2019 · N645GT · Boeing 767324 · Crew Oxygen SystemSDR UIEA2019041103851Line · looseLEFT ENGINE LEAKING OIL AROUND IDG AREA.(<P>FOUND L/H ENG HYD RETURN LOOSE. RE-TORQUED HYD ENG RETURN LINE REF AMM 29-11-05. MOTORED ENG, NO LEAKS NOTED.<BR /></P>)Apr 9, 2019 · N645GT · Boeing 767324 · Hydraulic System, MainSDR UIEA2019040 3762Start Valve · malfunctionedDURING LEFT ENGINE START, VALVE LIGHT DID NOT EXTINGUISH WITH START SELECTOR ON GND.(<P>DEFERRED IAW MEL 80-00-02-01 MDDR 109620. </P><P>LP 1042487- M2: REMOVED AND REPLACED START VALVE IAW AMM 80-11-02. OPS CHECK OK. CLEARED MDDR 109620 AND PLACARD REMOVED.</Apr 2, 2019 · N645GT · Boeing 767324 · Engine Start Valves/ControlsSDR UIEA2019033103743Packing · leakingDURING PNEUMATIC LEAK CHECK USING COMPRESSED NITROGEN AT #2 ENGINE CHECK FAILED AT LOCATION "K".(<P>REMOVED AND REPLACED #2 ENGINE PRV DAMAGED "O" RING AT ELBOW FITTING COMPRESS INLET. IAW AMM 36-11-18 NO LEAKS NOTED. REF: EO1936A088 LOCATION K.</P>)Mar 31, 2019 · N645GT · Boeing 767324 · Pneumatic Distribution SystemSDR UIEA2019040103740Sleeve · damagedAPU SURGE BLEED DUCTHAS A HOLE.(<P>REMOVED AND REPLACED APU SURGE BLEED DUCT SLEEVE. REF: AMM 79-53-01.</P>)Mar 31, 2019 · N645GT · Boeing 767324 · APU Bleed Air SystemSDR UIEA2019040103741Fire Loop · malfunctionedEICAS MSG ENGINE 1 O/H LOOP 1 AFTER ENGINE CHANGE.(<P>REMOVED AND REPLACED #1 ENGINE OVHT. DETECTOR. PER AMM 26-11-02. ACCOMPLISHED FIRE/OVHT. SYSTEM TEST OK. PER AMM 26-11-00.</P>)Mar 31, 2019 · N645GT · Boeing 767324 · Smoke DetectionSDR UIEA2019040103742Engine · oil consumptionREPLACE #1 ENGINE DUE OIL CONSUMPTION.(<P>REMOVED AND REPLACED #1 ENGINE. ACCOMPLISHED ENGINE RUN UP. NO DEFECTS AND NO LEAKS EVERYTHING NORMAL.PER AMM 71-00-00.</P>)Mar 31, 2019 · N645GT · Boeing 767324 · Engine (Turbine/Turboprop)SDR UIEA2019032403652Smoke Detector · false activationLAVATORY SMOKE EICAS(<P>L4 LAV POSITION TRANSFERED TO MEL 26-26-03-01A MDDR 109171 CAT C DUE 03APR PLACARD INSTALLED MAINTENANCE PROCEDURES C/W DETECTOR ISOLATED L4 DETECTOR INOP ONLY </P>)Mar 24, 2019 · N645GT · Boeing 767324 · Smoke DetectionSDR UIEA2019031903591Linkage · lack of lubeRIGHT PACK TEMP EICAS MESSAGE, SHOWED ON FINAL APPROACH. (<P>FAULT RAM INLET ACTUATOR LUBED LINKAGE AND OPS CHECKED GOOD IAW AMM 21-51-14. </P>)Mar 19, 2019 · N645GT · Boeing 767324 · Cabin Cooling SystemSDR UIEA2019031903592Sensor · unsecureLAVATORY SMOKE EICAS MESSAGE SHOWED DURING DESCENT (<P>REMOVED AND RE SECURED SMOKE DETECTOR SENSOR - OPS CHECKED GOOD IAW AMM 26-13-00 </P>)Mar 19, 2019 · N645GT · Boeing 767324 · Smoke DetectionSDR UIEA2019031503564Pump · failed"R AFT FUEL PUMP" EICAS MESSAGE. (<P>TRANSFER TO MEL 28-22-01 CAT C MDDR 108759. </P><P>LOG PAGE 1042385: REMOVED AND REPLACED RT AFT FUEL PUMP IAW AMM 28-22-03. NO MSG SHOWN, LEAK AND OPS CHECK OK. MCC NOTIFIED, THIS CLEARS MDDR 108759.</P>)Mar 15, 2019 · N645GT · Boeing 767324 · Fuel Boost PumpSDR UIEA2019031503545Connector · dirtyR PACK TEMP EICAS MESSAGE DISPLAYED.(<P>PREVIOUS FAULT RAM INLET ACTUATOR, CLEANED CONNECTOR ON RT RAM INLET ACTUATOR PER AMM 21-51-14.</P>)Mar 14, 2019 · N645GT · Boeing 767324 · Air Conditioning System WiringSDR UIEA2019030603489Controller · malfunctionedR PACK TEMP EICAS MESSAGE IN FLIGHT.(<P>ACCOMPLISHED FIM 21-51 TREE 803 AND BIT RIGHT PACK TEMP INLET ACT, RESET OF RT PACK TEMP CONTROLLER , OK AND OPS CHECK OF RT PACK OK AS PER AMM 21-51-00. </P>)Mar 5, 2019 · N645GT · Boeing 767324 · Cabin Cooling SystemSDR UIEA2019030503468Warning System · false activationCENTER L FUEL PUMP CAUTION MESSAGE.(<P>PERFORMED CENTER L FUEL PUMP OPERATIONAL CHECK IAW AMM 28-22-00 OK FOR SERVICE.</P>)Mar 5, 2019 · N645GT · Boeing 767324 · Aircraft Fuel Distribution SystemSDR UIEA2019021803252Warning Message · false indicationSTATUS WXR SYS MSG(<P>PERFORMED FIM 34-43- FT 805 WXR BITE PROCEDURES, NO FAULTS NOTED.</P>)Feb 18, 2019 · N645GT · Boeing 767324 · Weather Radar SystemSDR UIEA2019021803242Radar · malfunctioned#1 WEATHER RADAR INOP (<P>OPS CHECKED WEATHER RADAR #1, GOOD IAW B767 AMM 34-43-00</P>)Feb 18, 2019 · N645GT · Boeing 767324 · Weather Radar SystemSDR UIEA2019021983248Fuel Filter · warning messageR ENG FUEL FILT EICAS MSSAGE ON ALL CLIMB SEGMENTS(<P><SPAN>R/R / R/H ENGINE FUEL FILTER IAW AMM 73-11-02. OPS NORMAL LEAK CHECK GOOD.</SPAN></P>)Feb 16, 2019 · N645GT · Boeing 767324 · Engine Fuel DistributionSDR UIEA2019020653124Control Valve · failedRH PACK TEMP IN FLIGHT, OPS NORMAL PER QRH IN SWITCH N POSITION (<P>FOUND TEMP CONTROL VALVE ON PACK CONTROLLER ( RH ) , REMOVED AND REPLACED RH PACK TEMP CONTROL VALVE I.A.W AMM 21-51-12 OPS TEST GOOD NO FAULTS OR EICAS MSG </P>)Feb 5, 2019 · N645GT · Boeing 767324 · Cabin Cooling SystemSDR UIEA2019020433090Start Valve · unknownENG #2 START VALVE STOCK CLOSED(<P>RECYCLED START VALVE OPS CHECK GOOD IAW AMM 80-00-00</P>)Feb 2, 2019 · N645GT · Boeing 767324 · Engine Start Valves/ControlsSDR UIEA2019012002984Unknown · malfunctionedEICAS MESSAGE LEFT PACK (<DIV>FOUND PACK FLOW AND SHUTOFF VALVE WOULD NOT OPEN. REMOVED AND RECONNECTED ALL ELECTRICAL CONNECTORS - VALVE OPS CHECK GOOD IAW AMM 21-51-01</DIV>)Jan 20, 2019 · N645GT · Boeing 767324 · Cabin Cooling SystemSDR UIEA2019012303005Valve · malfunctionedLT FAN AIR VALVE CLOSED AND OPEN SWITCH DISAGREE.(<P>REPLACED FAN AIR VALVE</P>)Jan 19, 2019 · N645GT · Boeing 767324 · Pneumatic Distribution SystemSDR UIEA2019012303006Shutoff Valve · malfunctionedLT HPSOV CLOSED AND OPEN SWITCHES DISAGREE.(<P>RPELACED HPSOV.</P>)Jan 19, 2019 · N645GT · Boeing 767324 · Pneumatic Distribution SystemSDR UIEA2019011902980Fire Warning · false activationUPON LANDING FIRE WARNING BELL ACTIVATED WITH NO EICAS MSG.(<P>RESET WARN ELEX A AND WARN ELEX B CB'S AND OPS CHECKED GOOD IAW AMM 26-11-01.</P>)Jan 19, 2019 · N645GT · Boeing 767324 · Fire DetectionSDR UIEA2019011300069Slide · deployedR2 MID CABIN DOOR SLIDE DEPLOYED(<P>TRANSFER TO MDDR 105857 IAW MEL 52-11-04-01A CAT A PLACARD INSTALLED. MAINTENANCE PROCEDURES C/W, SLIDE REMOVED. LP: 1009981-M1: REMOVED AND REPLACED THE R2 DOOR SLIDE IAW AMM 25-66-01. THIS CLEARS MDDR 105857</P>)Jan 13, 2019 · N645GT · Boeing 767324 · Escape SlideSDR UIEA2019010800044Shutoff Valve · faultyLT PACK INOP(<P>TRANSFERRED TO MEL 21-51-01-01, MDDR 105657.</P><P>LP-1009969-M2 RE-SEATED CONNECTOR ON LEFT PACK FLOW CONTROL AND SHUT OFF VALVE OPS CHECK LEFT PACK OPS CHECK GOOD IAW AMM 21-51-01. LP 1009970-M1 REOPENED MDDR 105657</P><P>REF LOG PAGE 10099Jan 8, 2019 · N645GT · Boeing 767324 · Cabin Cooling SystemSDR UIEA2019010700029Battery Pack · dischargedEMERGENCY LIGHT ON SEAT 20AC 32AC DOES,T STAY ON WHILE SWITCH IS ON LOW BATTERY VOLTAGE(<P>REMOVED AND REPLACED BATTERY PACK AND TESTED OK IAW AMM 33-51-07</P>).Jan 6, 2019 · N645GT · Boeing 767324 · Emergency LightingSDR UIEA2018122802950Overheat Sys · false activationDURING CLIMB, AT APPROXIMATELY 8000 FEET, LEFT BLEED OVERHEAT LIGHT WAS FOLLOWED BY LEFT ENGINE BLEED OFF EICAS MESSAGE. QRH WAS FOLLOWED AND MESSAGE CLEARED.(<P>OPS CHECK OK IAW AMM 36-22-00. NO DEFECTS NOTED.<BR /></P>)Dec 27, 2018 · N645GT · Boeing 767324 · Overheat DetectionSDR UIEA2018120602789Anti-Ice Valve · faultyRIGHT WING ANTI-ICE VALVE DOES NOT MOVE OR WORK CORRECTLY. LIGHT TEST OK. VERIFIED EICAS MESSAGE FOR RT WING DEICE VALVE IS WORKING MM 30-11-00. REMOVED AND REPLACED RIGHT WING ANTI ICE VALVE IAW AMM 30-11-02. THIS OPS CHECK NORMAL.Dec 6, 2018 · N645GT · Boeing 767324 · Airfoil Anti/De-ice SystemSDR UIEA2018111982647Connector · looseLAV SMOKE EICAS CHIME ON DURING DECENT (<P>FOUND L4 LAV SMOKE DETECTOR SENSOR CONNECTOR LOOSE ,SECURED CONNECTOR AND OPS CHECKED GOOD IAW B767AMM 26-13-01 </P>)Nov 18, 2018 · N645GT · Boeing 767324 · Fire Protection System WiringSDR UIEA2018111972641Pump · malfunctionedRIGHT FWD FUEL PUMP C/B POPPED. REMOVED AND REPLACED RIGHT FWD BOOST PUMP IAW B767 AMM 28-22-03 NORMAL OPERATION OBSERVED.Nov 16, 2018 · N645GT · Boeing 767324 · Fuel Boost PumpSDR UIEA2018110502522Ground Wire · looseRIGHT FWD FUEL BOOST PUMP WAS INOPERATIVE. FOUND CONNECTOR GROUND LOOSE. TIGHTENED, CHECKED GOOD IAW AMM 28-22-03.Nov 2, 2018 · N645GT · Boeing 767324 · Fuel System WiringSDR UIEA2018102502340Switch · dirtyNO RIGHT ENG SPAR VALVE INDICATION DURING START. ENG STARTING NORMALLY. CLEANED GATE VALVE SWITCH ON SPAR VALVE. OPS CHECK C/W.Oct 24, 2018 · N645GT · Boeing 767324 · Fuel Boost PumpSDR UIEA2018102002292Sign · disconnectedEMER LIGHT SIGN INOP AT R2 DOOR LOWER. RECONECT EMER LIGHT SIGN AT R2 DOOR LOWER, OPS CHECK C/W IAW MM 33-50-00.Oct 20, 2018 · N645GT · Boeing 767324 · Emergency LightingSDR UIEA2018101902291Anti-Ice Valve · malfunctionedLEFT WING ANTI ICE EICAS MESSAGE ON CLIMB. WING ANTI ICE WERE OFF. REMOVED AND REPLACED LEFT WING ANTI ICE VALVE V52 IAW AMM 30-11-02. OPS CHECK NORMAL, NO LEAK NOTED.Oct 15, 2018 · N645GT · Boeing 767324 · Airfoil Anti/De-ice SystemSDR UIEA2018101502261Generator · inoperativeAPU INOP. REMOVED AND REPLACED APU GENERATOR IAW AMM 24-21-01. OPS CHECK NORMAL AND NO OIL LEAK NOTED.Oct 12, 2018 · N645GT · Boeing 767324 · AC Generator-AlternatorSDR UIEA2018101002226Connector · dirtyRIGHT ENGINE SPAR VALVE SLOW TO CYCLE ON START. CLEANED SPAR VALVE CONNECTOR, OP'S CHECK NORMAL IAW AMM 28-22-01.Oct 9, 2018 · N645GT · Boeing 767324 · Fuel System WiringSDR UIEA2018101002227Connector · unsecureEMERGENCY LIGHT AT 6K INOP. SECURED CONNECTOR AT SEAT 6K EMERG. LIGHT OP'S CHECK GOOD IAW WDM 33-51-18.Oct 9, 2018 · N645GT · Boeing 767324 · Light System WiringSDR UIEA2018101002228Light · inoperativeRIGHT PACK DOES NOT TURNOFF VIA PACK CONTROL SWITCH. RE-LAMPED RIGHT PACK LIGHT OP'S CHECK NORMAL IAW AMM 33-13-00.Oct 9, 2018 · N645GT · Boeing 767324 · Flight Compartment LightingSDR UIEA2018101002230Control Valve · not reportedAS PER MCC REQUEST REMOVE AND REPLACE RIGHT PACK FLOW CONTROL VALVE. REMOVED AND REPLACED RIGHT PACK FLOW CONTROL VALVE. OP'S CHECK NORMAL, NO LEAKS IAW AMM & 21-51-01.Oct 9, 2018 · N645GT · Boeing 767324 · Cabin Cooling SystemSDR UIEA2018092802128Warning System · false activationSELECTED SYS 2 WX RADAR INFLIGHT WX FAIL MESSAGE ON HSI AND WXR SYS STATUS MESSAGE. PERFORMED WEATHER RADAR BITE CHECK IAW AMM 34-43-00 NO DEFECTS NOTED AT THIS TIME.Sep 24, 2018 · N645GT · Boeing 767324 · Weather Radar SystemSDR UIEA2018092102026Control Valve · malfunctionedRT PACK TEMP, COMPLETED QRH. REMOVED AND REPLACED ACM TEMP CONTROL VALVE. OPS CHECKED GOOD IAW AMM 21-51-01.Sep 20, 2018 · N645GT · Boeing 767324 · Cabin Cooling System
Back to N645GT