N648UA
Service difficulty reports · 327
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N648UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N648UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010061402067Adc · malfunctionedADC FAILURE, RTFL. CREW REPORTS SHORTLY AFTER ROTATION AND GEAR RETRACTION, APPEARED TO HAVE A RT AIR DATA SYS FAIL. F/O'S AIRSPEED IND, AND ALTIMETER WOUND UP, GOT FALSE AIRSPEED WARNINGS, RUDDER RATIO, TCAS, AND NUMEROUS OTHER AIR DATA DEPENDENT SYS FAILURESDR UALA2010061402064Battery Pack · inoperativeLEFT EXIT EMERGENCY LIGHT JUST AFT OF THE FLAP INOP. FOUND LIGHT AFT OF THIS LIGHT ALSO INOP. RELAMPED BOTH BUT NO HELP. T-S REF WDM, RANG ALL 4 (5A) FUSES IN M738 RANG GOOD, M738 IS LOCATED AT SEAT 37ABC. BATTERY PACK M738 TO BE REPLACED IS BY STA 1349 (LSDR UALA2010061402090Skin · puncturedRT INBD T/E FLAP HAS PUNCTURE ON TOP SIDE. PUNCTURE WITHIN LIMITS IAW SRM. SEALED WITH SPEED TAPE, INSPECT EACH "A CHECK". DO A REPAIR NO LATER THAN THE NEXT "C CHK". SHOP 273 WILL NEED T/E AFT FLAP REMOVED FOR IN SHOP REPAIR. 5 SHIFT SLOT RQSTD FOR TE FLAP SDR UALA2010060902016Adc · faultyFO ALT, AIRSPEED AND VSI HAVE OFF FLAGS. OK WHEN AIR DATA ALTN SELECTED. ALSO TCAS FAIL ON HSI. AIR DATA COMPUTER REPLACED. REMOVED AIR DATA P/N. INSTALLED NEW AIR DATA. ALL TESTS PASS WITH SUCCESS.SDR UALA2010060101893Actuator · faultyRT AILERON LOCK OUT ACTUATOR. NEED TO REPLACE RT AILERON LOCK OUT ACTUATOR. IT DID HIT AGAIN. REPLACED RT AILERON LOCKOUT ACTUATOR. OPS CHECKED GOOD.SDR UALA2010052501799Actuator · faultyLT & RT AILERON LOCKOUT MSGS. DUE TO REPEAT WRITE UP OF AILERON LOCKOUT NEED TO REPLACE THE RT & LT AILERON LOCKOUT ACTUATORS. REPLACED THE RT & LT AILERON LOCKOUT ACTUATORS. FUNCTION TESTS OK.SDR UALA2010051101604Actuator · failedRT CENTER ELEVATOR PCA FAILS SINGLE HYD SOURCE OP CHECK. RT ELEV MOVES 4-5 SECONDS SLOWER NOSE UP THAN LT SIDE. REPLACED CENTER SYSTEM RT ELEVATOR PCA. OPS GOOD.SDR UALA2010031700894Window · crazedCAPTAIN'S FIXED SIDE-FORWARD WINDOW'S VISIBILITY IS AFFECTED BY DEFECTS. REPLACE FIRST AVAILABLE. CREW COMMENTS: WITH CERTAIN LIGHT ANGLES WINDOW VISIBILITY REDUCED. CAPTAINS FIX SIDE FORWARD WINDOW VISIBILITY IS AFFECTED BY DEFECTS REPLACE OR REPAIR FIRSTSDR UALA2010031700893Window · crazedTHE 1ST OFFICER'S FIXED SIDE-AFT WINDOW'S VISIBILITY IS AFFECTED BY DEFECTS, REPLACE FIRST AVAILABLE. CREW COMMENTS: WITH CERTAIN ANGLES OF LIGHT WINDOW VISIBILITY REDUCED. THE 1ST OFFICERS FIX SIDE AFT WINDOW VISIBILITY AFFECTED REPLACE OR REPAIR FIRST MAISDR UALA2010021700611Lap Joint · corrodedCABIN BLANKETS SATURATED WITH H2O ROW 24. FOUND AFTER PRESSURIZING. LOW AND HIGH GAIN ANT, ADF ANTENNA AND LAP JOINT. REMOVING INTERIOR TO AGAIN ACCESS TO LAP JOINT AREA AND WET INSULATION. INSPECTED AREA. FOUND NO OBVIOUS DEFECTS. REMOVED OLD SEALANT AND SDR UALA2010021500564Valve · stuckCHRONIC IMPOSSIBLE TO CONTROL CABIN TEMP IN AUTO OR MANUAL OR STANDBY MODES. ACFT VERY COLD. FOUND TRIM AIR PRESSURE REGULATING VALVE STUCK CLOSED. REPLACED VALVE AND ACCOMPLISHED CHECKS.SDR UALA2009123004061Amplifier · inoperativeSATCOM INOPERATIVE. AMPLIFIER FOUND FAULTY. REPLACED AMPLIFIER, OP'S CHECKED OK. CALLED SAMC ON SATCOM, ALL CHECKED NORMAL.SDR UALA2009122804006Warning Light · illuminatedFUEL CONFIGURATION LIGHT ON IN FLIGHT. ACCOMPLISHED SERVICE TIP. NO FUEL MOVEMENT NOTED FROM RT TO LT MAIN FUEL TANKS AT THIS TIME. UNABLE TO VERIFY FUEL MOVEMENT BETWEEN RT AND LT MAIN TANK.SDR UALA2009122203963Clamp · brokenNR 1 ENGINE FWD CLAMP ON IP VALVE HAS BROKEN LINKS. LINKS FOUND BROKEN. REPLACED CLAMP.SDR UALA2009122203958Battery Pack · inoperativeRT AISLE EMERGENCY LIGHTS INOP ROW 23 THRU 26. REPLACED BATTERY PACK AND PWR SUPPLY, OPS CHECKED OK.SDR UALA2009121403859Valve · faultyLT BLEED AIR DUCT PRESSURE FLUCTUATES WILDLY AT TAKEOFF & CLIMB. THRUST NORMAL AT CRUISE POWER. REMOVED AND REPLACED PRSOV. RPL HIGH PRESSURE CONTROLLER (P/N 773289-15 (S/N 133), RPL PRV CONTROLLER (P/N 792755-8 (S/N 166). NO HELP. ACP'D PNEUMATIC HEALTH CHKSDR UALA2009113003700Controller · faultyL HPSOV FLUCTUATES WITH THROTTLES AT IDLE IN DESCENT. DURING PNEUMATIC HEALTH CHECK FOUND HPSOV SLUGGISH AND CONTROLLER FAILING TO COMMAND VALVE CLOSURE. REPLACED VALVE AND CONTROLLER. ALL CHECKS NORMAL.SDR UALA2009092803035Battery · dischargedSEAT MOUNTED EMERGENCY EEL LIGHT INOP FROM SEAT ROW 19ABC TO 23ABC. EEL LIGHT COMES ON BUT MOMENTARILY. REPLACED BATTERY AT SEAT 22 ABC, M737, SECURED CONNECTORS M1559.SDR UALA2009092803034Charger · inoperativeEXTERIOR EMERGENCY LIGHT INOP AT DOOR 2L. RELAMP, NO HELP. NEED MORE TIME TO T-S. REPLACED BATTERY CHARGER M738, OP CHECKS NORMAL.SDR UALA2009092803033Charger · faultyEXTERIOR EMERGENCY LIGHT INOP AT FUSELAGE AFT OF LT TRAILING EDGE. RELAMP, NO HELP. NEED MORE TIME TO T-S. REPLACED BATTERY CHARGER M738, OP CHECKS NORMAL.SDR UALA2009092803032Light · inoperativeEXTERIOR EMERGENCY LIGHT INOP AT DOOR 1L. RELAMPED, OPS CHECKED OKAY.SDR UALA2009092803031Battery Pack · dischargedSEAT MOUNTED EMERGENCY EEL LIGHT INOP FROM SEAT ROW 19ABC TO 23ABC. EEL LIGHT COMES ON BUT MOMENTARILY. ORDERED BATTERY PACK. BATTERY LOCATION AT SEAT 22ABC. REPLACED BATTERY AT SEAT 22ABC, M737, SECURED CONNECTORS M1559.SDR UALA2009092102984Idg · failedEICAS MSG R GEN DRIVE DISPLAYED. GEN DRIVE LIGHT ILLUM. GEN DRIVE DISCONNECTED. ACP'D BPCU BITE AND CHECKED SCAVENGE FILTER (CLEAN FILTER AND DPI NOT POPPED). RESET AND RAN, NO HELP. REPLACED R ENG IDG AND ALL OPS GOOD. ENG RAN AND NO LEAKS APPARENT.SDR UALA2009092102973Starter · failedOBSERVED SPARKS AND OIL LEAKING FROM PNEUMATIC STARTER DURING WET MOTORING FOR FUEL LEAK CHECK. REPLACED PNEUMATIC STARTER, OPS CHECK OK.SDR UALA2009092102968Valve · leakingFUEL RUNNING LEAK ON THE FLOW DIVIDER AREA LEFT ENGINE. DURING CHECK FOUND LEAK COMING FROM THE FUEL DISTRIBUTION VALVE. REPLACED VALVE AND TRANSFER TUBE PACKINGS. WET MOTORED ENGINE, NO MORE LEAKS FOUND.SDR UALA2009083102733O-Ring · cutHYD QTY DECREASED. QTY STABLE WITH EDP DEPRESSURIZED & ACMP OFF. POS 2 (01=L,02=R). CREW COMMENTS: WITH R PUMPS ON R HYD QTY SYS DECREASED FAST R HYD QTY LT ON. FOUND THE EDP DIFFERENTIAL PRESS INDICATOR LEAKING. FOUND THE O-RINGS WORN/CUT. REPLACED O-RSDR UALA2009081802532Gcu · faultyRT GEN FIELD OFF LIGHT WON'T RESET. SWAPPED GOOD GEN CONT UNIT, RAN ENG GEN FIELD LIGHT CAME ON AFTER ENG SHUT DOWN. BITE CHK BPCU FAULT MSG. SHORTED PMG, GEN-FIELD, AND WIRING-GEN. FOUND GENERATOR CONTROL UNIT WAS TRIPPED INTERMITTENTLY.SDR UALA2009080502353Pump · inoperativeFUEL DRIPPING FROM NR 2 ENG AFTER SHUTDOWN, APPROX 70 DPM. INSPECTED NR 2 ENG FUEL LEAK. LEAK APPEARS TO BE COMING FROM VENT HOLE AT FWD LOWER RT SIDE OF FUEL PUMP. STEADY STREAM AFTER SHUT-DOWN. WILL NEED TO REPLACE FUEL PUMP. RECEIVED BOOST PUMP, NEED FSDR UALA2009080402346Battery Pack · dischargedLEFT AFT EXT EEL DOOR SLIDE LIGHT INOPERATIVE. REPLACED BATTERY PACK M738, TEST OKAY.SDR UALA2009060101575Fuel Tank · leakingWEEP HOLE INSIDE OF NR 2 ENGINE ON WING LEAKING FUEL AT 80 DROPS PER MINUTE. ACP TANK 2 AND RT WING TANK ENTRY FOUND FUEL SEEPING INTO DRY BAY FROM LOWER FWD O/B SECTION. RESEALED AND LEAK CHECKED WITH 19K FOB. ALL CHECKS OKAY.SDR UALA2009051901418Actuator · faultyAILERON LOCKOUT EICAS AND OVERHEAD LT ON. REPLACED RT OTBD AILERON LOCKOUT ACTUATOR.SDR UALA2009033100934Pump · faultyAFTER 3 HRS IN CRUISE RT FUEL QTY 2000LBS LWR THAN LT QTY. REPLACE CTR RT OVERRIDE PUMP REF RT FUEL TANK QUANTITY IMBALANCE. REPLACED CTR RT OVERRIDE PUMP. NEEDS LEAK AND OPS TEST. ACCOMPLISHED OVERRIDE JETTISON OP'S CHECK. LEAK CHECK GOOD.SDR UALA2009032300863Hydraulic Line · leakingNR 1 ENG, OIL DRIPPING FROM LARGE DRAIN TUBE BOTTOM OF REVERSER COWL. FOUND EVIDENCE OF ACTIVE HYD LEAK INSIDE NR 1 PYLON ACCESS PLATE RT OF PYLON. FOUND TORQUE OF HYD B-NUTS AT INSIDE OF DISCONNECT PANEL OK. APPEARS TO BE COMING FROM ABOVE AND AFT OF ACCESSDR UALA2009021800546Battery · faultyRIGHT EMERGENCY ESCAPE SQUIB WON'T TEST. REPLACED BATTERY FOR RT SYSTEM. OPS CHECKS NORMAL ON GROUND.SDR UALA2009011900213Anti-Ice Valve · faultyLEFT ENG ANTI-ICE VALVE DISAGREE LIGHT ILLUMINATED WITH SWITCH IN THE "ON" POSITION. REPLACED NR 1 ENGINE INLET THERMAL ANTI-VALVE.SDR UALA2009010500048Light · inoperativeRT MID CLOSET FLOOR EEL INOP. REPLACED RT MID CLOSET FLOOR EEL LIGHT BAR AND OPS CHECK GOOD.SDR UALA2009010500047Battery · dischargedEXTERIOR EMERGENCY LIGHTS INOP. REPLACED BULB. OPS CHECK GOOD AND ALLOWED BATTERIES TO CHARGE.SDR UALA2009010500039Angle · crackedCRACKS FOUND ON NR1 PYLON CLOSEOUT ANGLE, 2ND FASTENER FROM INBD EDGE AT 0:00 POS AND 0900 POS. MAJOR REPAIR ACCOMPLISHED: STOPPED DRILLED CRACKS AND INSTALLED FILLER AND STRAP DOUBLER REPAIR.SDR UALA2009010500037Skin · delaminatedLT INBD ELEVATOR UPPER SURFACE OB END DELAMINATED. REMOVED DELAMINATED PLIES AND INSTALLED REPAIR.SDR UALA2009010500026Skin · crackedCRACK ON UPPER FWD RADIUS ON PANEL CUTOUT NR 2 PYLON INBOARD SIDE, PANEL 446BL. MAJOR REPAIR ACCOMPLISHED, STOP DRILLED 2 EA CRACKS. INSTALLED REPAIR DOUBLERS.SDR UALA2008112406619Light · inoperativeEEL FLOOR PATH LIGHTING AT RT MID LAV ARE INOP. REPLACED EEL LIGHT, CHECKS GOOD.SDR UALA2008112106610Power Cable · damagedEMERGENCY FLOOR PATH LIGHTING LEFT AISLE FIRST LIGHT IN FIRST CLASS CABIN IS INOP. REPAIRED POWER FEED LINE. OPS CHECKS GOOD.SDR UALA2008112106611Connector · brokenCREW REPORTED FUEL CONFIGURATION EICAS ON DESCENT. FOUND ENTIRE CONNECTOR BROKEN AT THE DIFFERENTIAL PRESSURE SWITCH, D11000. REPLACED NR 1 ENG FUEL FLOW CONNECTOR. NR 1 ENGINE, 5 MINUTE IDLE RUN ACCOMPLISHED. NO LEAKS NOTED.SDR UALA2008111306270Fan Blade · dentedNUMEROUS FAN BLADES HAVE SMALL NICKS & DENTS ON BOTH NR 1 & NR 2 ENGINES. ALL DAMAGED FAN BLADES BLENDED ON BOTH NR 1 & NR 2 ENGINES.SDR 2008UALA06270Blade · damagedNUMEROUS FAN BLADES HAVE SMALL NICKS & DENTS ON BOTH NR 1 & NR 2 ENGINES.SDR 2008UALA06130Hydraulic Line · crackedHYDRAULIC PROBLEM. RTFL. FOUND HYDRAULIC LANDING GEAR UP TUBE ASSY CRACKED. ALSO 2 OTHER TUBES INTERFERING AND DAMAGING. REPLACED TUBES OKAY. LEAK CHECK CARRIED OUT NO FAULTS FOUND. SURROUNDING AREA CLEANED OKAY.SDR 2008UALA05802Starter · malfunctionedL ENG START VALVE WON'T OPEN. START VALVE MALFUNCTIONED. REPLACED STARTER AND STARTER VALVE. ALL CHK NORMAL.SDR 2008UALA04024Microphone · inoperativeCAPTAIN'S OXYGEN MASK MIC INOP. *S/D* SUSPECT PRE FLIGHT CHECKS. REPLACED NR 1 O2 BOX. AC OK FOR SERVICE.SDR 2008UALA03989Actuator · faultyRIGHT PACK INOP LIGHT ON. S/D* FOUND FAULTY ACTUATOR. REPLACED ACTUATOR PER MM 21-53-04, OP CHECKED GOOD. AC OK FOR SERVICE.
SDR 2008UALA03865Warning Message · illuminatedCREW REPORTS: RT ENG "OIL FILTER MSG AT ENGINE START, MSG CLEARED AFTER ENG START TOOK 15 SEC , OAT WAS 15C & OIL TEMP WAS BELOW 35C". DEFERRED. MAIN OIL FILTER TO BE REPLACED WITHIN 50 FLIGHT HOURS. MAIN OIL FILTER SUBSEQUENTLY REPLACED AT ORD. RAN ENGIN
Back to N648UA