N649UA
Service difficulty reports · 272
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N649UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N649UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA06344Structure · damagedRT SIDE FUSELAGE DAMAGE FROM STA 1131 TO 1175 STRINGERS 18R TO 20R. MAJOR REPAIR ACCOMPLISHED. MANUFACTURED REPAIR DOUBLER TRIPLER AND FILLER REPAIR.
SDR UALA2008111306298Wire · exposedWIRES EXPOSED ON EMERGENCY FLOOR LIGHTS. REPLACED EEL LIGHT STRIP AND COVER.SDR 2008UALA06298Wire · exposedWIRES EXPOSED ON EMERGENCY FLOOR LIGHTS.
SDR 2008UALA03847Wire · frayedSECOND OBSERVER O2 MASK MIC WIRE IS FRAYED. *S/D* FOUND MIC WIRE FRAYED. REPLACED 2ND OBS O2 MASK PER MM 35-11-51. AC OK FOR SERVICE.SDR 2008UALA03400Duct · crackedLT PACK INOPERATIVE - REHEATER INLET DUCT CRACKED. *S/D* SUSPECT IMPROPER INSTALLATION. REPLACED LT PACK REHEATER DUCT PER MM 21-51-21. OP CHECKS NORMAL. AC OK FOR SERVICE.SDR 2008UALA02969Regulator Valve · faultyLEFT ENG BLEED AIR VALVE WILL NOT OPEN. DUCT PRESSURE ON LEFT SIDE IS ZERO. ADVANCED ENG POWER AND STILL NO HELP. FOUND PRESSURE REGULATING VALVE TO BE FAULTY. REPLACED PRV, RAN ENGINE OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02955Light · brokenREF SMC001 ON EEL STRIP BROKEN, NEW STRIP IS IN PLACE AND WILL REQUIRE SPLICING AND RE-ASSEMBLY OF EEL STRIP CABLE PROTECTIVE COVERS AND CARPET. FOUND LIGHT ASSEMBLY BROKEN. SPLICED IN SECTION OF EEL LIGHT ASSEMBLY, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02603Valve · malfunctionedFWD EQUIPMENT VALVE EICAS MSG ON LANDING. FOUND OVERBOARD VALVE AND COOLING CONTROL PANEL FAULTY. REPLACED FORWARD OVERBOARD VALVE, AND EQUIPMENT COOLING CONTROL PANEL. OP CHECKS NORMAL. AC OK FOR SERVICE.SDR 2008UALA02328Wire · brokenEMERGENGY LIGHT L313 AT DOOR IL HAS BROKEN WIRE. LIGHT ASSY LOCATED AT FWD UPPER CORNER OF DOOR FRAME VISIBLE FROM OUTSIDE WITH DOOR OPEN. FOUND BROKEN WIRE AT LIGHT ASSEMBLY. REPAIRED WIRE AND OP CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA01585Light · missingEMERGENCY LIGHT ON FLOOR 1E PLASTIC IS MISSING.SDR 2008UALA00955Check Valve · faultyNR 1 ENGINE HAS THE L BLEED OFF EICAS MSG AND L-BLEED OFF LIGHT ON WITH BLEED SELECTED. REPLACED ISOLATION BYPASS CHECK VALVE. FOUND DIRECT SHORT AT PRSOV CONNECTOR. FOUND D22 CONNECTOR ON PRSOV BAD. REPLACED SAME. OPS CHECKED GOOD. REPLACED PRSOV. LEAKSDR 2007UALA04969Aspirator · leakingLEAKING ASPIRATOR.
SDR 2007UALA04561Pump · unknownRTFL DUE TO CENTER HYDRAULIC PUMP PROBLEM. REPLACED HYDRAULIC AIR DRIVEN PUMP. ALSO REPLACED HYD LINES & PUMP MOUNTS. PERFORMED SYSTEM CHKS. OK FOR SERVICE.
SDR 2007UALA04311Unknown · odorELECTRICAL BURNING ODOR IN MID GALLEY AREA AND AIRCRAFT RETURNED TO BLOCKS. INSP GALLEY AREA AND OVERHEAD AREA FOR EVIDENCE OF BURNING NO OBVIOUS SIGHT OF SMOKE OR BURNING. FIRE BRIGADE PERFORMED HEAT DECTECTOR EQUIPMENT NO SIGN FOUND.NO HISTORY () INSP CHILLSDR 2007UALA04163Lamp · inoperativeDURING EQUIP COOLING TEST, SMOKE LIGHT DOES NOT COME ON AND NO FWD EQUIPMENT SMOKE ADVISORY MESSAGE. RELAMPED SMOKE DETECTOR. OPS CK OK PER JC EQUIP COOLING TEST.SDR 2007UALA03557Oxygen Mask · defectiveOXYGEN MASK DEFECTIVE AT 2.(1=CAPT,2=1ST OFF,3=1ST OBS). CREW COMMENTS: O2 MASK INFLATABLE BAND BURST.SDR 2007UALA03562Light · inoperativeEEL LIGHT INOP LOCATED AT FIRST CLASS ZONE LEFT AISLE.SDR 2007UALA03561Light · inoperativeEEL LIGHT INOP LOCATED AT FIRST CLASS ZONE RIGHT AISLE.SDR 2007UALA03560Bezel · missingBEZEL IS MISSING FROM EEL LIGHT AT ROW 18 BC.SDR 2007UALA03558Light · inoperativeEEL LIGHT INOP LOCATED MID ZONE LAVATORY LEFT & RIGHT AISLES.SDR 2007UALA02926Power Supply · faultyRIGHT SIDE BUSINESS CLASS EXIT STRIP LIGHTING ON AND OFF INTERMITTENTLY. PER FLT ATTENDANT, THE RT SIDE IN FIRST CLASS ONLY & AROUND DOOR 1R HAD THE PROBLEM. REPLACED POWER SUPPLY M1552. CHECKS GOOD.SDR 2007UALA02874Floorbeam · mismanufacturedCABIN FLOORBEAM AT BS 368 AND RBL 58 HAS 2 EACH MISDRILLED HOLES, ONE THROUGH UPPER CHORD AND WEB AND THE OTHER IN THE UPPER CHORD RADIUS. CUTOUT DAMAGE IN WEB AND OVERSIZED THE 2 MISDRILLED HOLES. FABRICATED 1 REPAIR ANGLE FOR THE FWD AND AFT SIDE OF THE FLSDR 2007UALA02821Wire · brokenEEL LEAD WIRE BROKEN. REMOVED AND REPLACED EEL LIGHT BARS PER MM 33-51-10 AND OPS CHECK GOOD PER MM 33-51-00 ON N-R 25692.SDR 2007UALA02820Lamp · inoperativeRIGHT SIDE EXTERNAL OVERWING EMERGENCY EXIT LIGHT IS INOPERATIVE. TROUBLESHOT AND FOUND BAD LAMP. REMOVED AND REPLACED LAMP. OPS CHECKS GOOD.SDR 2007UALA02745Stiffener · crackedCABIN FLOORBEAM STA 246 VERTICAL STIFFENER AT FWD FACE, RBL 11, CRACKED AT BEND RADIUS. [08-14-07] REMOVED AND REPLACED VERTICAL STIFFENER PER SRM 53-10-51, PARAGRAPH 3. AIRPLANE READY FOR SERVICE. SUSPECT FATIGUE EXACERBATED BY ASSEMBLY PRE-LOAD.SDR 2007UALA02720Floor Panel · gougedFWD CARGO PIT TORQUE FLOOR GOUGED FWD AND AFT OF PDU 8C, RBL 5, STA 560. [08-14-07] FOUND OUT OF LIMITS. FABRICATED NEW PANEL PER BAC DWR 451T2504. INSTALLED NEW PANEL PER SRM51-40-02. AIRPLANE RETURNED TO SERVICE READY.SDR 2007UALA02612Hose · damagedRIGHT OVERWING SLIDE CYLINDER LWR INFLATION HOSE IS KINKED AND COLLAPSED. [08-07-07] REPLACED HOSE IAW 20-10-10. SLIDE PROBLEM ROOT CAUSE: SLIDE & INFLATION HOSE ARE IN AN AREA CONTAINING MANY HYDRAULIC LINES & SERVICING ACCESS; SUSPECT HOSE DAMAGED BY SSDR 2007UALA02559Latch · wornRIGHTHAND OVERWING SLIDE COMPARTMENT DOOR NR 3 LATCH WORN. REMOVED & REPLACED LATCH AND KEEPER.SDR 2007UALA02504Floorbeam · corrodedFWD GALLEY FLOOR AREA, STA 246 AT RBL 72 AREA, BULKHEAD WALL, LOWER FLOOR CHORD CORRODED UNDER SHEAR WEBBING, FWD EDGE. REMOVED DAMAGED SECTION OF CHORD, RBL 49 TO RBL 72. FABRICATED & INSTALLED SPLICE & REPAIR ANGLES.SDR 2007UALA02503Latch · bindingLEFT OVERWING SLIDE DOOR NR 2 LATCH BINDING. [08-08-07] REPLACED AND ADJUSTED LATCH PER MM25-65-98. DOOR 2 LATCH MOVES FREELY. SLIDE & AIRCRAFT OK FOR SERVICE. SLIDE PROBLEM ROOT CAUSE: SLIDE LATCHES EXPERIENCE FRETTING CAUSED BY VIBRATION & EXCESSIVE CLESDR 2007UALA01216Generator · unknownCREW REPORTS LOSS OF LEFT GENERATOR. [SUP 05-04-07] REPLACED LEFT ENGINE INTEGRATED DRIVE GENERATOR. RAN UP ENG PER JRH 2-6-1, IDG OPERATED NORMALLY. OUTBOUND TRIP DID VERIFICATION TEST AND IDG OPERATED OK. SUSPECT INTERNAL WEAR LED TO FAULTY HERTZ OUTPUT SDR 2007UALA00834Slide · low pressureDOOR 1R SLIDE PRESSURE READS BELOW SERVICEABLE LIMIT. REPLACED R1 DOOR SLIDE PER MM 25-66-01. CAUSED BY SUSPECT SEAL LEAKAGE AT BOTTLE CONNECTION.SDR 2006UALA01994Circuit Card · failedEICAS MSG 'LDG GEAR MONITOR' DISPLAYED WITH LDG GEAR UP AND LOCKED. FOUND ALL EXCEPT 4 CIRCUIT CARDS DISLODGED IN PSEU. REMOVED AND REINSTALLED ALL CIRCUIT CARDS.SDR 2006UALA01688Skin · crackedNR 1 ENG PYLON INBOARD SIDE 2 INCH CRACK OUTER SKIN OUT OF INSPECTION PANEL CUTOUT.SDR 2006UALA01394Battery Pack · failedSQUIB TEST ON EMERGENCY ESCAPE SLIDES WILL NOT TEST. REPLACED RIGHT AND LEFT SQUIB BATTERY PACKS PER AMM 25-65-17. SQUIB TESTS GOOD.SDR 2006UALA00912Odor · detectedDIVERTED TO YBG DUE TO ELECTRICAL ODOR AND FUMES IN FLIGHT DECK. CHK'D FOR BURNED WIRING AND PROBLEMS WITHIN E&E COMPARTMENT. NO EICAS MESSAGE NOTED BY FLIGHT CREW. CLEANED DIRTY OVENS AT FWD GALLEY. CHECKED WIRING AND COMPONENTS IN AREA AND FOUND NO DISCRSDR 2006UALA00713Aspirator · malfunctionedBOTH ASPIRATORS STAYED OPEN DURING SLIDE DEPLOYMENT.SDR 2006UALA00708Trigger · brokenLEFT OVERWING SLIDE PACK TRIGGER BROKEN. REPLACED SLIDE. AIRCRAFT RELEASED TO SERVICE. ROOT CAUSE WAS SLIDE PACK TRIGGER BROKEN DURING INSTALLATION.SDR 2006UALA00637Hinge Fitting · crackedRIGHT INBOARD AFT FLAP, CENTER HINGE FITTING CRACKED ON OUTBOARD SIDE IN COVE AREA. *S/D* THE RIGHT INBOARD AFT FLAP, CENTER HINGE FITTING, WAS FOUND CRACKED ON THE OUTBOARD SIDE IN THE COVE AREA. REPAIRED FITTING PER 767 SRM 57-53-02.SDR 2006UALA01187Latch · wornNR 1 AND NR 2 LATCHES EDGE MARGIN BEYOND LIMITS. REMOVED AND REPLACED LATCHES.SDR 2005UALA01036Door · separatedDIVERTED TO YQX DUE TO AIRFRAME VIBRATION. RAM AIR INLET DOOR ASSY WAS FOUND WITH FORWARD INLET DOOR ASSY P/N 213T3010-1 MISSING. AFT HINGE ASSY P/N 213T3108-4 ATTACHING THE FORWARD AND AFT INLET DOOR ASSY WAS ALSO MISSING. FORWARD HINGE ASSY P/N 213T3109-4SDR 2004UALA00998Wire · burnedFOUND WIRES W298-021-08, W1046-913-08, W1046 -012-10, W1046-028-12. BURNED AT TB 5132 TERMINAL BLOCK INSIDE P37. REPLACED TERMINAL STRIP TB5132 IN P37 PANEL.SDR 2004UALA00911Hinge · crackedRIGHT WING INBOARD FLAP CENTER EXTERNAL HINGE IS CRACKED. MAJOR REPAIR ACCOMPLISHED. REPAIRED FLAP HINGE WITH REPAIR ANGLES AND FILLER.SDR 2004UALA00912Seat Track · crackedMAIN CABIN SEAT TRACK LBL 88 AT BS 747.5 TO 808 BROKEN, CRACKED AND CORRODED. DAMAGED SEAT TRACK REPLACED.SDR 2004UALA00914Hinge · crackedLEFT WING INBOARD FLAP CENTER EXTERNAL HINGE IS CRACKED. MAJOR REPAIR ACCOMPLISHED. REPAIRED HINGE WITH REPAIR ANGLES.SDR 2004UALA00913Spar · crackedNR 2 NACELLE UPPER SPAR WEB IS CRACKED SEVERAL PLACES AS SEEN THROUGH ACCESS 446BL. REPAIRED UPPER SPAR WEB WITH DOUBLER AND FILLER JUST FWD OF PYLON AFT BLKHD PER SRM 54-53-01, FIG 208. PER SB 767-54-0092 R1 PROBABLE CAUSE OF CRACKING IS FLEXING OF PYLON MISDR 2004UALA00701Control Panel · failedFLIGHT DIVERTED DUE TO WX RADAR FAILURE. CREW REPORTED WX RADAR INOP. DOES NOT PAINT AND GREEN ARC ON DISPLAY. ALSO, NO GROUND RETURNS. ( THE GREEN ARC IS A FLAT PLATE ANTENNA ANOMALY THAT DOES NOT AFFECT WX RADAR PERFORMANCE.) MAINTENANCE REPLACED THE WX RSDR 2004UALA00049Battery · inoperativeEMERGENCY EXIT PATH LIGHTS ROW 15-17 BLINK ON AND OFF. REPLACED M737 BATTERY ASSEMBLY.SDR 2003UALA00186Smoke Detector · malfunctionedSMOKE ALARM WENT OFF IN AFT LAV. NO SMOKE OBSERVED AND FLIGHT LANDED UNEVENTFULLY. SUPPLEMENTAL DATA UPDATE THE AFT CENTER LAV SMOKE DETECTOR WAS AT FAULT. THE UNIT WAS REPLACED WITH P/N PU90-461R3 (PCN 563-3542) . THE SYSTEM CHECKED FINE AFTERWARD.SDR 2002UALA01482Wire Harness · damagedEEL LIGHTING DAMAGED AT RIGHT HAND BUSINESS CLASS GALLEY. REPLACED TWO DAMAGED EEL LIGHTING STRIPS. REPAIRED DAMAGED POWER LEAD AND INSTALLED NEW LIGHTING COVER STRIP.
Back to N649UA