N655UA
Service difficulty reports · 383
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N655UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N655UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA02959Light · looseEMERGENCY LIGHT STRIP IN BUSINESS GALLEY LOOSE. FOUND LIGHT ASSEMBLY LOOSE. SECURED LIGHT ASSEMBLY, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02869Light · damagedEMERGENCY LIGHTS IN FLOOR LOOSE RIGHT SIDE ACROSS FROM BUSINESS GALLEY. FOUND DAMAGED LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY. AC OK FOR SERVICE.SDR 2008UALA02868Light · malfunctionedEMERGENCY FLOOR LIGHTING INOP WHEN ACTUATED FROM CABIN. CARRIED OUT TROUBLESHOOTING PER MM AND ACTIONED OPS TEST OF EMERGENCY ESCAPE PATH LIGHTING EEL SYSTEM PER MM 33-51-00 PAGE 503-504, SATIS. AC RELEASED FOR SERVICE.SDR 2008UALA02274Aspirator · damagedSLIDE HAS A DAMAGED ASPIRATOR. BARREL IS BENT FROM EXTERNAL PRESSURE OR CONTACT. NO VISIBLE DAMAGE TO SLIDE MATERIAL. REPLACED ASPIRATOR.SDR 2008UALA02208Battery · faultyMAIN BATTERY CHARGER STATUS MSG. SUSPECT FAULTY BATTERY. REPLACED MAIN BATTERY OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA01866Module · brokenLAV 124 OXYGEN MASK COMPARTMENT DOOR BROKEN OFF AND MASK FELL DOWN. REPLACED PASSENGER OXYGEN MODULE. AC OK FOR SERVICESDR 2008UALA01784Idg · failedL GENERATOR DRIVE LIGHT ILLUMINATED. LOST LEFT GENERATOR. NR 1 ENGINE IDG DISCONNECTED DUE TO FAULTS. REPLACED IDG AND GEN CONTROL UNIT (PRECAUTIONARY). GENERATING SYSTEM OP CHKD OK FOR SERVICE.
SDR 2008UALA01750Light · unsecureEMERGENCY LIGHT STRIP COMING UP AT RT SIDE OF BUS GALLEY AT ROWS 10E-F.
SDR 2008UALA01722Idg · disconnectedEICAS MSG L GEN DRIVE DISPLAYED. GEN DRIVE LIGHT ILLUM. GEN DRIVE DISCONNECTED.SDR 2008UALA01561Light · brokenEEL STRIP BROKEN BY MID GALLEY. REPLACED SPLICES, CRIMPER AND PLASTIC COVER. CHECKED EMERGENCY LIGHT OK.SDR 2008UALA01367Wire · exposedEMERGENCY LIGHT STRIP ON FLOOR ROW 14B IS PULLED UP W-WIRES SHOWING. REPAIRED LIGHT BAR OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA00590Valve · leakingASPIRATOR LEAKING. FAULTY VALVE. REPLACED SLIDE AND ASPIRATOR. ACFT OK FOR SERVICE.SDR 2008UALA00523Wire · arcedTHE 9B READING LIGHT WIRES EXPOSED AND ARCING. REPLACED READING LIGHT OPS CHECK NORMAL. AC OK FOR SERVICE.SDR 2008UALA00480Actuator · intermittentRUDDER TRIM INTERMITTENTLY INOP. SUSPECT FAULTY TRIM ACTUATOR. REPLACED RUDDER TRIM ACTUATOR. OP CHECKS NORMAL. ACFT OK FOR SERVICE.SDR 2007UALA05040Indicator · malfunctionedCREW REPORT RUDDER TRIM INDICATOR IS HESITANT WHEN TRIM SELECTED PRIOR TO DEPARTURE.SDR 2007UALA04663Power Supply · intermittentEEL LIGHTS FLICKER ON AND OFF AT LEFT SIDE OF FIRST CLASS. SUSPECT BAD PWR PACK. PREVIOUS HISTORY. REPLACED BATTERY POWER SUPPLY PACK. TEST FLOOR EEL LIGHTS. OP CHKS GOOD.
SDR 2007UALA04449Starter · making metalNR 2 ENG STARTER MAG CHIP DETECTOR SHOWS LARGE FLAKES OF METAL. ALSO THE NR 1 ENG STARTER DRAINED AN INSUFFICIENT AMOUNT OF OIL. ALSO BLACK AND BURNED AND HAS AN ODOR. NR 1 STARTER FOUND WITH LOW OIL AND OIL LOOKS BLACK AND BURNED REPLACED STARTER. AFTER SESDR 2007UALA04339Connector · out of adjustEMERGENCY EEL LIGHT TURN ON AND OFF AT SEATS 1AB. ADJUSTED PLUG AT POWER SUPPLY NEXT TO THE SEAT 1AB. CHECKED OK.
SDR 2007UALA03467Bulkhead · gougedNR 1 PYLON, GOUGED BULKHEAD FITTING AT NAC STA 237.39. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED AREA. CUT OUT PREVIOUSLY TRIMMED FLANGE FROM BULKHEAD (P/N 311T3281). FABRICATED A REPAIR ANGLE & A REPLACEMENT BRACKET (272T0082-28) & A REPLACEMENT CLIP (31SDR 2007UALA03451Skin · damagedLEADING EDGE OF LEFT OUTBOARD ELEVATOR UPPER SURFACE IS CHIPPED ABOVE HINGE AT 240.SDR 2007UALA03450Skin · corrodedEXTERNAL FUSELAGE, STA 1554 BETWEEN STR 24L AND STR 25L, FWD LAV VENT, SKIN AROUND EXHAUST BULGED AND CORRODED. REPAIRED PER REO G12120 REV A AND EVA-70582. STARTING AT 37,500FC MUST ACP A DETAILED VISUAL INSP EXT AND INTERNAL AND A LFEC EXT SKIN AND MUST CSDR 2007UALA03335Fastener · improper partREPAIR AT BS 294-303 AT STR 27L FOUND WITH BLIND FASTENERS. REMOVED BLIND FASTENERS AND REPLACED WITH SOLID FASTENERS.SDR 2007UALA03334Stiffener · crackedFLOORBEAM STA 246 VERTICAL STIFFENER CRACKED AT RBL 26 FWD SIDE. MAJOR REPAIR ACCOMPLISHED: REMOVED CRACKED STIFFENER. INSTALLED NEW STIFFENER.SDR 2007UALA03333Stiffener · crackedFLOORBEAM STA 246 VERTICAL STIFFENER CRACKED AT RBL 12 FWD SIDE. MAJOR REPAIR ACCOMPLISHED: REMOVED CRACKED STIFFENER. LOCATED, DRILLED & INSTALLED NEW STIFFENER.SDR 2007UALA03332Floorbeam · crackedFLOORBEAM STA 246 T-CAP ANGLE CRACKED AT LBL 12, AFT SIDE. MAJOR REPAIR ACCOMPLISHED: REMOVED CRACKED SECTION OF CAP ANGLE. FABRICATED & INSTALLED ANGLE REPAIR.SDR 2007UALA03331Attach Bracket · crackedFLOORBEAM INTERCOSTAL ATTACH BRACKET CRACKED AT STA 303, BL 0. MAJOR REPAIR ACCOMPLISHED: REMOVED CRACKED ANGLE. FABRICATED & INSTALLED NEW ANGLE.SDR 2007UALA03330Skin · dentedEXTERNAL FUSELAGE STA 1197+110 BETWEEN STR 39R AND 38L SKIN DENTED INSIDE OUT. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGE. HFEC INSPECTION TO VERIFY DAMAGE REMOVAL. NO CRACKS FOUND. FABRICATED & INSTALLED FILLER AND DOUBLER.SDR 2007UALA02985Cylinder · inadequateRIGHT OVERWING SLIDE INFLATION CYLINDER IS INADEQUATE. REPLACED SLIDE INFLATION CYLINDER TO ACCOMPLISH COA 616942. ALSO FOUND COLLAPSED INFLATION HOSE DUE TO HYD FLUID CONTAMINATION. CHECKED OK FOR SERVICE.SDR 2007UALA01686Flashlight · inoperativeEMERGENCY FLASHLIGHT INOPERATIVE. LOCATION FLIGHT ATTENDANT SEAT 260 MID CABIN. [07-10-07] REPLACED EMERGENCY FLASHLIGHT ASSY. AIRCRAFT OK FOR SERVICE.SDR 2006UALA02026Warning Light · illuminatedRETURNED TO JFK UNDER DUE TO LEADING EDGE FLAP INDICATION. ALL CHECKS FOUND NORMAL.SDR 2006UALA02009Engine · leakingDIVERTED TO BOS DUE TO LOST OF OIL IN THE NR 2 ENGINE. FOUND STARTER TO GEARBOX MOUNTING FLANGE CRACKED AND LEAKING. STARTER HAD BEEN REPLACED PRIOR TO FLIGHT. REPLACED NR 2 ENGINE GEARBOX HOUSING ASSEMBLY.SDR 2006UALA01870Wire · damagedEICAS MESSAGE NORM ANTISKID & ALTN ANTI-SKID DISPLAYED. TAKEOFF FOLLOWED BY STATUS MESSAGE :ANTISKID CNTRL SHOWS XDUCR 7 FAULT, REPLACED TRANSDUCER 7. PROBLEM CONTINUED. FOUND WIRE TO PIN 1 IN TRANSDUCER CONNECTOR, D2024, BROKEN IN BACKSHELL CLAMP. REPLACED SDR 2006UALA01325Display · malfunctionedRETURNED TO IAD DUE TO MULTIPLE NAVIGATIONAL DISPLAY PROBLEMS. CAPT & F/O ADI'S WERE LOSING COLOR & BLANKING. DURING IN-FLIGHT TROUBLESHOOT CREW ALSO NOTED CONFIG LIGHT AND GEAR NOT DOWN MESSAGE. AS A RESULT, 4 LRU'S WERE REMOVED:CAPT. ADI, CENTER SG, LANDISDR 2006UALA00917Unknown · unknownDIVERTED TO YYZ WITH ELECTRICAL PROBLEMS. RT GEN TRIPPED OFF ON TAKEOFF DRIVE LIGHT & EICAS ILLUM, DISCONNECTED IDG. OIL WAS FOULD LOW, SERVICED WITH 4 QUARTS OF OIL, NO EXTERNAL LEAKS EVIDENT. RAN ENGINE WITH IDG ON LINE FOR 20 MINS ALL OPS NORMAL. RE-INSDR 2006UALA00711Slide · departedLEFT WING SLIDE APPEARS TO HAVE DEPARTED THE AIRCRAFT ON CLIMBOUT.SDR 2006UALA00698Skin · crackedAFT LT FUSELAGE SKIN DENTED & CRACKED AT STA 1197 + 84 AND STRINGER S-19L.SDR 2006UALA00571Generator · unknownRETURNED TO IAD DUE TO NR 2 GENERATOR PROBLEM. AFTER EVENT, INITIAL IDG SERVICE AND ENGINE RUN PRODUCED NO FAULTS OR LEAKAGE, AND MONITORING AC REVEALED NO DUPLICATE EVENTS. INDICATION OF LOW OIL PRESSURE FROM INTERNAL CHARGE PRESSURE SWITCH CLOSURE MOST LIKESDR 2005UALA01126Windshield · crackedCAPTAINS WINDSHIELD CRACKED. FLIGHT DIVERTED TO LHR.SDR 2004UALA00925Hinge Fitting · crackedLT WING IB FLAP OB HINGE FITTING CRACKED AFT VANE. SUPPLEMENTAL DATA UPDATE REPAIRED FITTING WITH ANGLE AND FILLER REPAIR.SDR 2004UALA00924Floorbeam · crackedFLOORBEAM STA 246 STIFFENER AT APPROX RBL 20 IS CRACKED. CRACK CAUSED BY CYCLIC DEFLECTION FATIGUE. FABRICATED & INSTALLED NEW STIFFENER.SDR 2004UALA00921Floorbeam · crackedFLOORBEAM STA 246 STIFFENER AT RBL 15 IS CRACKED. CRACKS CAUSED BY CYCLIC DEFLECTION FATIGUE. FABRICATED AND INSTALLED NEW BRACKET.SDR 2003UALA00407Skin · puncturedFOUND 3/8 INCH HOLE IN BULK CARGO PIT DOOR 25 INCHES FROM TOP OF DOOR AND 1-3/4 INCHES FROM AFT SIDE OF DOOR. DOUBLER INSTALLED.SDR 2003UALA00402Skin · puncturedTEMPORARY DOUBLER OVER THE 3 INCH X 4 INCH HOLE IN ACFT FUSELAGE, 1 FOOT AFT OF AFT MAIN CARGO AREA LOADING LIGHT, ON RIGHT SIDE OF ACFT. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPLACED.SDR 2002UALA01865Heater · failedCAPTAIN'S PITOT TUBE, RUDDER RATIO AND AILERON LIGHT CAME ON. CAPTAIN'S AIRSPEED INDICATOR NON OP, ALTIMETER VARIED PLUS 100, MINUS 200 FT AT FL330 WITH AUTOPILOT ENGAGED. ON DESCENT SYSTEMS RETURNED TO NORMAL. FLIGHT DIVERTED TO LAS. SUPPLEMENTAL DATA UPDASDR 2002UALA01295Pump · faultyINDICATION OF A LEFT CENTER BOOST PUMP FAILURE WITH POSSIBLE FUEL IMBALANCE. THE LEFT CENTER FUEL TANK OVERRIDE PUMP WAS REPLACED AND OPS CHECKED OK. SYSTEM OPERATION NORMAL THROUGH 8/25/2002. SHOP TEST OF THE REMOVED PUMP WAS PERFORMED WITH NO DEFECTS NOTESDR 2002UALA00630Panel · missingON ARRIVAL FOUND DORSAL FIN PANEL MISSING. THE DORSAL FIN PANEL WAS REPLACED. THE FUSELAGE SKIN IN THE AREA OF THE DORSAL FIN WAS VISUALLY AND HFEC INSPECTED TO ENSURE THAT NO DAMAGE TO THE FUSELAGE SKIN OCCURRED.SDR 2002UALA00246Skin · gougedFUSELAGE LOWER SKIN GOUGED OUT OF LIMITS AT LEFT HAND STAB CUTOUT AT STATION 1740, STRINGER 19R. MAJOR REPAIR ACCOMPLISHED. REPAIRED SKIN.SDR 2002UALA00245Skin · gougedFUSELAGE SKIN GOUGED OUT OF LIMITS AT LEFT HAND LOWER FORWARD STAB CUTOUT AT STATION 1735, STRINGER 19R. MAJOR REPAIR ACCOMPLISHED. REPAIRED SKIN.SDR 2002UALA00244Skin · crackedFUSELAGE LOWER SKIN CRACKED AT RIGHT HAND LOWER FORWARD STAB CUTOUT STATION 1740, STRINGER 19R. MAJOR REPAIR ACCOMPLISHED. REPAIRED SKIN.SDR 2002UALA00243Skin · crackedFUSELAGE SKIN CRACKED AT RIGHT HAND LOWER STAB CUTOUT STATION 1735 AT STRINGER 19R. MAJOR REPAIR ACCOMPLISHED. SKIN CRACKED.